• Title/Summary/Keyword: Inlet Valve

Search Result 236, Processing Time 0.024 seconds

Temperature Variation of Exhaust Gas in Diesel Generator for Low Pressure SCR (저압 SCR을 위한 디젤발전기 배기가스 온도 변화)

  • Hong, Chul Hyun;Lee, Chang Min;Lee, Sang Duk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.2
    • /
    • pp.355-362
    • /
    • 2021
  • To facilitate low-pressure selective catalyst reduction (L.P SCR), a high exhaust-gas temperature of a four-stroke diesel engine for a ship's generator is required. This study aimed at reducing the exhaust-gas temperature by adjusting the valve open-close timing and fuel injection timing to satisfy the operating conditions of L.P SCR and prevent accidents associated with the generator engine due to high temperature. To lower exhaust-gas temperature, the angle of the camshaft was adjusted and the shim of the fuel injection pump was added. As a result, the maximum explosion pressure increased and the average of the turbocharger outlet temperature dropped. Considering the heat loss from the turbocharger outlet to the SCR inlet, the operation condition for L.P SCR was satisfied with 290 ℃. The study demonstrates that safe operation of a diesel generator can be achieved by lowering the exhaust-gas temperature.

The Clinical Application and Results of Palliative Damus-Kaye-Stansel Procedure (고식적 Damus-Kaye-Stansel 술식의 임상적 적용 및 결과)

  • Lim, Hong-Gook;Kim, Soo-Jin;Kim, Woong-Han;Hwang, Seong-Wook;Lee, Cheul;Shinn, Sung-Ho;Yie, Kil-Soo;Lee, Jae-Woong;Lee, Chang-Ha
    • Journal of Chest Surgery
    • /
    • v.41 no.1
    • /
    • pp.1-11
    • /
    • 2008
  • Background: The Damus-Kaye-Stansel (DKS) procedure is a proximal MPA-ascending aorta anastomosis used to relieve systemic ventricular outflow tract obstructions (SVOTO) and pulmonary hypertension. The purpose of this study was to review the indications and outcomes of the DKS procedure, including the DKS pathway and semilunar valve function. Material and Method: A retrospective review of 28 patients who underwent a DKS procedure between May 1994 and April 2006 was performed. The median age at operation was 5.3 months ($13\;days{\sim}38.1\;months$) and body weight was 5.0 kg ($2.9{\sim}13.5\;kg$). Preoperative pressure gradients were $25.3{\pm}15.7\;mmHg$ ($10{\sim}60\;mmHg$). Eighteen patients underwent a preliminary pulmonary artery banding as an initial palliation. Preoperative main diagnoses were double outlet right ventricle in 9 patients, double inlet left ventricle with ventriculoarterial discordance in 6,. another functional univentricular heart in 5, Criss-cross heart in 4, complete atrioventricular septal defect in 3, and hypoplastic left heart variant in 1. DKS techniques included end-to-side anastomosis with patch augmentation in 14 patients, classical end-to-side anastomosis in 6, Lamberti method (double-barrel) in 3, and others in 5. The bidirectional cavopulmonary shunt and Fontan procedure were concomitantly performed in 6 and 2 patients, respectively. Result: There were 4 hospital deaths (14.3%), and 3 late deaths (12.5%) with a follow-up duration of $62.7{\pm}38.9$ months ($3.3{\sim}128.1$ months). Kaplan-Meier estimated actuarial survival was $71.9%{\pm}9.3%$ at 10 years. Multivariate analysis showed right ventricle type single ventricle (hazard ratio=13.960, p=0.004) and the DKS procedure as initial operation (hazard ratio=6.767, p=0.042) as significant mortality risk factors. Four patients underwent staged biventricular repair and 13 received Fontan completion. No SVOTO was detected after the procedure by either cardiac catheterization or echocardiography except in one patient. There was no semiulnar valve regurgitation (>Gr II) or semilunar valve-related reoperation, but one patient (3.6%) who underwent classical end-to-side anastomosis needed reoperation for pulmonary artery stenosis caused by compression of the enlarged DKS pathway. The freedom from reoperation for the DKS pathway and semilunar valve was 87.5% at 10 years after operation. Conclusion: The DKS procedure can improve the management of SVOTO, and facilitate the selected patients who are high risk for biventricular repair just after birth to undergo successful staged biventricular repair. Preliminary pulmonary artery banding is a safe and effective procedure that improves the likelihood of successful DKS by decreasing pulmonary vascular resistance. The long-term outcome of the DKS procedure for semilunar valve function, DKS pathway, and relief of SVOTO is satisfactory.

A Study on the Effects of Various Disk Shape of Hydrant on the Pressure Drop (옥외소화전의 디스크 형상을 고려한 압력손실에 관한 연구)

  • You, Woo Jun;Shim, Myoung Gyu;Sung, Kun Hyuk;Yu, Jae Bum;Youm, Moon Cheon;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.1-7
    • /
    • 2013
  • In this study, the effects of various disk shapes of hydrant on the pressure drop are experimentally and numerically analyzed. The test methods for measuring pressure drop of hydrant are comply with standard of Underwriters Laboratory (UL). The hydrant as used in this study has one inlet, diameter 150 mm, and three outlet, 114.3 mm diameter for one outlet and 63.5 mm diameter for the others. The pressure of the hydrant are measured in the range 760 L/min~2,270 L/min for 63.5 mm outlet and 3,030 L/min~6,060 L/min for 114.3 mm outlet. Also, the numerical results of pressure drop are compared with the experiments to verify the accuracy and to analyze the of various valve shape of hydrant on the pressure drop. The engineering parameters, flow coefficients, are reduced from 181.57 to 136.35 ($L/min/kPa^{0.5}$) with inclined angle of disk from $0^{\circ}$ to $45^{\circ}$. These results are able to practical use for design hydrant to minimize pressure drop.

Effect of aeration on the physicochemical characteristics of livestock feces compost during composting period (퇴비화과정 중 공기공급 여부가 가축분뇨 퇴비의 물리화학적 특성에 미치는 영향)

  • Jeong, Kwang-Hwa;Kang, Ho;Kim, Tai-ll;Park, Chi-Ho;Yang, Chang-Buem
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.11 no.4
    • /
    • pp.57-65
    • /
    • 2003
  • Livestock farming is one of several industries that have faced criticism because of its impact on the water quality, soil contamination and air pollution. The livestock feces can cause some environmental problems. The best way to treat the feces is to recycle the manure as an organic fertilizer after fermentation or composting. This study was carried out to investigate the characteristics of composting of manure in several composting conditions. The variations of physicochemical characteristics of each compost piles containing different level of air volume were analyzed throughout the composting period. In this study, pigs manure compost piles mixed with saw dust were composted in 110L of laboratory scale plastic vessels and $1.5m^3$ of small cubic wooden composting vessels for 60days. The compost piles were ventilated continuously with air pump throughout the composting duration. The air volume ventilated into the piles was regulated by chock valve attached to the inlet pipe. The ventilation level was adjusted by 20, 50, 100, 150 and $200L/m^3/mim$, respectively. The highest temperature of the compost increased to $72^{\circ}C$ during composting period. After 20days from beginning of fermentation, concentrations of $H_2S$, $CH_3SH$, DMS and DMDS generated from compost piles were 29, 16, 6 and 5ppb in blow in state compost pile, conversely, in blow out state compost pile, the parameters were 32, 24, 15 and 14ppb, respectively.

  • PDF

Numerical Analysis of Flow Characteristies inside innes part of Fluid Control Valve System (유동해석을 통한 유체제어벨브 시스템의 내부 유동 특성 분석)

  • Son, Chang-Woo;Seo, Tae-Il;Kim, Kwang-Hee;Lee, Sun-Ryong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.160-166
    • /
    • 2018
  • The worldwide semi-conductor market has been growing for a long time. Manufacturing lines of semi-conductors need to handle several types of toxic gases. In particular, they need to be controlled accurately in real time. This type of toxic gas control system consists of many different kinds of parts, e.g., fittings, valves, tubes, filters, and regulators. These parts obviously need to be manufactured precisely and be corrosion resistant because they have to control high pressure gases for long periods without any leakage. For this, surface machining and hardening technologies of the metal block and metal gasket need to be studied. This type of study depends on various factors, such as geometric shapes, part materials, surface hardening method, and gas pressures. This paper presents strong concerns on a series of simulation processes regarding the differences between the inlet and outlet pressures considering several different fluid velocity, tube diameters, and V-angles. Indeed, this study will very helpful to determine the important design factors as well as precisely manufacture these parts. The EP (Electrolytic Polishing) process was used to obtain cleaner surfaces, and hardness tests were carried out after the EP process.

Mid-term results of IntracardiacLateral Tunnel Fontan Procedure in the Treatment of Patients with a Functional Single Ventricle (기능적 단심실 환자에 대한 심장내 외측통로 폰탄술식의 중기 수술성적)

  • 이정렬;김용진;노준량
    • Journal of Chest Surgery
    • /
    • v.31 no.5
    • /
    • pp.472-480
    • /
    • 1998
  • We reviewed the surgical results of intracardiac lateral tunnel Fontan procedure for the repair of functional single ventricles. Between 1990 and 1996, 104 patients underwent total cavopulmonary anastomosis. Patients' age and body weight averaged 35.9(range 10 to 173) months and 12.8(range 6.5 to 37.8) kg. Preoperative diagnoses included 18 tricuspid atresias and 53 double inlet ventricles with univentricular atrioventricular connection and 33 other complex lesions. Previous palliative operations were performed in 50 of these patients, including 37 systemic to pulmonary artery shunts, 13 pulmonary artery bandings, 15 surgical atrial septectomies, 2 arterial switch procedures, 2 resections of subaortic conus, 2 repairs of total anomalous pulmonary venous connection and 1 Damus-Stansel-Kaye procedure. In 19 patients bidirectional cavopulmonary shunt operation was performed before the Fontan procedure and in 1 patient a Kawashima procedure was required. Preoperative hemodynamics revealed a mean pulmonary artery pressure of 14.6(range 5 to 28) mmHg, a mean pulmonary vascular resistance of 2.2(range 0.4 to 6.9) wood-unit, a mean pulmonary to systemic flow ratio of 0.9(range 0.3 to 3.0), a mean ventricular end-diastolic pressure of 9.0 (range 3.0 to 21.0) mmHg, and a mean arterial oxygen saturation of 76.0(range 45.6 to 88.0)%. The operative procedure consisted of a longitudinal right atriotomy 2cm lateral to the terminal crest up to the right atrial auricle, followed by the creation of a lateral tunnel connecting the orifices of either the superior caval vein or the right atrial auricle to the inferior caval vein, using a Gore-Tex vascular graft with or without a fenestration. Concomitant procedures at the time of Fontan procedure included 22 pulmonary artery angioplasties, 21 atrial septectomies, 4 atrioventricular valve replacements or repairs, 4 corrections of anomalous pulmonary venous connection, and 3 permanent pacemaker implantations. In 31, a fenestration was created, and in 1 an adjustable communication was made in the lateral tunnel pathway. One lateral tunnel conversion was performed in a patient with recurrent intractable tachyarrhythmia 4 years after the initial atriopulmonary connection. Post-extubation hemodynamic data revealed a mean pulmonary artery pressure of 12.7(range 8 to 21) mmHg, a mean ventricular end-diastolic pressure of 7.6(range 4 to 12) mmHg, and a mean room-air arterial oxygen saturation of 89.9(range 68 to 100) %. The follow-up duration was, on average, 27(range 1 to 85) months. Post-Fontan complications included 11 prolonged pleural effusions, 8 arrhythmias, 9 chylothoraces, 5 of damage to the central nervous system, 5 infectious complications, and 4 of acute renal failure. Seven early(6.7%) and 5 late(4.8%) deaths occured. These results proved that the lateral tunnel Fontan procedure provided excellent hemodynamic improvements with acceptable mortality and morbidity for hearts with various types of functional single ventricle.

  • PDF