• 제목/요약/키워드: Inlet Part

검색결과 275건 처리시간 0.023초

Efficiency of a hybrid solid digestion-denitrification column in suspended solid and nitrate removal from recirculating aquaculture system

  • Pungrasmi, Wiboonluk;Chaisri, Ratchadaporn;Malaphol, Ekachai;Powtongsook, Sorawit
    • Environmental Engineering Research
    • /
    • 제20권2호
    • /
    • pp.175-180
    • /
    • 2015
  • This research focused on the solid and nitrate removal efficiency in a solid digestion-denitrification column. The 20 L up-flow column consisted of 18 L acrylic column with 2 L down-comer inlet tube located in the middle. In the first part, the wastewater with high suspended solids from the Tilapia fish tank was applied into the sedimentation unit at 5 variable flow rates i.e., 11.25, 25.71, 60, 105.88 and 360 L/h. The results indicated that the flow rate of 11.25 L/h (0.57 m/h) gave the highest solid removal efficiency of $72.72%{\pm}8.24%$. However, the total suspended solids removal was highest at 360 L/h (18.13 m/h). In the second part, methanol was added as an external organic carbon source for denitrification process in a hybrid column containing settled solids. The COD:N ratios of 0.5:1, 1:1, 2:1, 3:1, 4:1, 5:1 and 6:1 were investigated and compared with control without methanol addition. This experiment was operated at the HRT of 1 h with 450 L wastewater from recirculating aquaculture pond containing 100 mg-N/L sodium nitrate. The results indicated that the COD:N ratio of 3:1 gave the highest nitrate removal efficiency of $33.32%{\pm}21.18%$ with the denitrification rate of 5,102.88 mg-N/day.

주름높이의 변화를 고려한 판형열교환기의 완전발달유동 및 열전달 수치해석 (Numerical Simulation of the Fully Developed Flow and Heat Transfer of a Plate Heat Exchanger Taking into Account Variation in the Corrugation Height)

  • 모정하
    • 대한기계학회논문집B
    • /
    • 제36권1호
    • /
    • pp.1-8
    • /
    • 2012
  • 본 연구에서는 주름높이가 고려된 판형열교환기의 완전발달유동 및 열전달특성을 수치적으로 해석하였다. 여러 개의 단위셀(5개 또는 7개)을 연결한 다중셀에 입구부와 출구부가 부착된 모델을 기본으로 P/H비 변화($2.0{\leq}P/H{\leq}4.0$)에 따른 모델에 대하여 수치해석을 수행하였다. 작동유체는 물이며, 수치조건은 쉐브론각 $20^{\circ}$, $300{\leq}Re{\leq}1,500$이다. 그리고 마찰인자는 $f=CRe^m$의 형태로, Colburn 계수는 $j=CRe^m$의 형태로 상관관계식을 제시하였다. 수치해석 결과 완전발달유동은 세 번째 셀부터 시작되었으며, 누셀트수는 P/H비가 작을수록 큰 값을 나타냈다.

복합열산화(Hybrid Thermal Oxidation) 시스템을 이용한 MEK(Methyl ethyl ketone)와 Toluene 제거 평가 (Evaluation of Hybrid Thermal Oxidation(HTO) System for Removal of MEK(Methyl ethyl ketone) and Toluene)

  • 장두훈;배우근;김문일;김경태
    • 한국지반환경공학회 논문집
    • /
    • 제11권6호
    • /
    • pp.31-37
    • /
    • 2010
  • 본 연구에서는 multi-bed 플레이트로 폐열재생 부분과 촉매반응 부분으로 구성되어 있는 복합열산화 시스템(Hybrid Thermal Oxidation System)을 이용하여 저온에서 주입 밸브 교체 시간간격과 유입유량을 변화시켜 VOCs(MEK와 Toluene) 제거를 평가하고자 하였다. $350^{\circ}C$의 연소온도 조건에서 VOCs는 완전히 전환되었으며 당량비에 따른 전환율 또한 100%에 근접하였고, HTO 시스템의 연소실은 좌우측의 온도가 균형을 이루며 열효율이 매우 높아 폐열회수 및 재생이 효율적이었다. 주입 밸브 교체 시간간격과 유입 유량 변화에 따른 HTO시스템에서의 VOCs 제거 효율은, MEK와 Toluene 모두 안정적으로 높은 91.1~97.4%의 효율을 나타내었으며, 보조연료량 증가보다는 밸브교대시간을 길게 하였을때 제거 효율이 증가하는 경향을 보여 보조연료량 증가보다 밸브교대시간을 증가시키는 것이 제거 효율을 높이는데 효율적으로 판단된다. 이와 같은 연구결과를 고려할 때 HTO시스템은 저농에서도 VOCs 제거, 특히 MEK과 Toluene 제거에 매우 안정적이며 콤팩트한 시스템으로 판단되며, 적은 설치 부지로 중소기업이 요구하는 새로운 VOCs 제거 시스템으로 적용 가능하리라 판단된다.

전력변환장치 캐비넷에서의 내부발열 개선을 위한 열유동 분석 및 유통안전성 향상을 위한 진동특성 분석 (Theoretical Heat Flow Analysis and Vibration Characteristics During Transportation of PCS(Power Conversion System) for Reliability)

  • 주민정;서상욱;오재영;정현모;박종민
    • 한국포장학회지
    • /
    • 제28권2호
    • /
    • pp.143-149
    • /
    • 2022
  • PCS needs to freely switch AC and DC to connect the battery, external AC loads and renewable energy in both directions for energy efficiency. Whenever converting happens, power loss inevitably occurs. Minimization of the power loss to save electricity and convert it for usage is a very critical function in PCS. PCS plays an important role in the ESS(Energy Storage System) but the importance of stabilizing semiconductors on PCB(Printed Circuit Board) should be empathized with a risk of failure such as a fire explosion. In this study, the temperature variation inside PCS was reviewed by cooling fan on top of PCS, and the vibration characteristics of PCS were analyzed during truck transportation for reliability of the product. In most cases, a cooling fan is mounted to control the inner temperature at the upper part of the PCS and components generating the heat placed on the internal aluminum cooling plate to apply the primary cooling and the secondary cooling system with inlet fans for the external air. Results of CFD showed slightly lack of circulating capacity but simulated temperatures were durable for components. The resonance points of PCS were various due to the complexity of components. Although they were less than 40 Hz which mostly occurs breakage, it was analyzed that the vibration displacement in the resonance frequency band was very insufficient. As a result of random-vibration simulation, the lower part was analyzed as the stress-concentrated point but no breakage was shown. The steel sheet could be stable for now, but for long-term domestic transportation, structural coupling may occur due to accumulation of fatigue strength. After the test completed, output voltage of the product had lost so that extra packaging such as bubble wrap should be considered.

SMART 유동분포시험장치 노심모의기에서의 횡방향 유동 특성 (Cross Flow Characteristics of the Core Simulator in SMART Reactor Flow Distribution Test Facility)

  • 윤정;김영인;정영종;이원재
    • 한국유체기계학회 논문집
    • /
    • 제15권4호
    • /
    • pp.5-11
    • /
    • 2012
  • To identify the flow characteristics of the SMART reactor, a flow distribution model test and a numerical simulation are performed in KAERI. Among several part of the SMART reactor, the fuel assemblies are simulated using simulators because of the complexity. The geometries of the core in the SMART reactor and simulator are different, but some similarities are maintained such as the ratio of pressure drop in the vertical and cross directions. There are cross flow holes in each core simulator to reproduce the cross flow of SMART fuel assemblies. To know the flow characteristics of the cross flow, numerical analysis is performed. As the cross flow area is decreased, the pressure drop between inlet and outlet is decreased. Also, when the flow imbalance between two core simulators is constant, the cross flow area does not significantly affect the cross flow.

익렬 통로 내의 2차유동 및 손실에 관한 실험 연구 (An experimental study on the secondary flow and losses in turbine cascades)

  • 정양범;신영호;김상현
    • 대한기계학회논문집B
    • /
    • 제22권1호
    • /
    • pp.12-24
    • /
    • 1998
  • The paper presents the mechanism of secondary flows and the associated total pressure losses occurring in turbine cascades with turning angle of about 127 and 77 degree. Velocity and pressure measurements are taken in seven traverse planes through the cascade passage using a prism type five hole probe. Oil-film flow visualization is also conducted on blade and endwall surfaces. The characteristics of the limiting streamlines show that the three dimensional separation is an important flow feature of endwall and blade surfaces. The larger turning results in much stronger contribution of the secondary flows to the loss developing mechanism. A large part of the endwall loss region at downstream pressure side is found to be very thin when compared to that of the cascade inlet and suction side endwall. Evolution of overall loss starts quite early within the cascade and the rate of the loss growth is much larger in the blade of large turning angle than in the blade of small turning angle.

Magnetic Force-based Immunochip using Superparamagnetic Nanoparticles

  • Park, Je-Kyun;Kim, Kyu-Sung
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2005년도 생물공학의 동향(XVI)
    • /
    • pp.19-19
    • /
    • 2005
  • This paper reports a novel magnetic force-based microfluidic immunoassay using microbeads and magnetic nanoparticles. The magnetic force-based immunoassay was devised first and successfully applied to detect the rabbit IgG as the model analyte of microfluidic sandwich immunoassay. The microchannels were fabricated by poly(dimethysiloxane) (PDMS) molding processes and bonded on a slide glass by plasma treatment. At the part of the inlet, sample solution was hydrodynamically focused. The focused microbeads of sample solution were flowed through the 150 ${\mu}m$ width channel of outlet. However, when the microbeads are conjugated with the superparamagnetic nanoparticles under the applied magnetic fields, they will switch their flow path and flow through the 95 ${\mu}m$ width channel of outlet. The movements of microbeads conjugated with magnetic nanoparticles were demonstrated by magnetic field $gradients.^{1)}$ High magnetic field gradients using micro electromagnets could be applied to this detection method for high sensitivity and lower detection limit. In addition, the multiplexed $immunoassay^{2)}$ using an encoded microbead which is immobilized with a certain antibody could be possible using this detection principle.

  • PDF

팁 간극 영향으로 인한 원심 압축기 성능특성 시험연구 (Experimental Study on the Effect of Tip Clearance of a Centrifugal Compressor)

  • 차봉준;임병준;양수석;이대성
    • 한국유체기계학회 논문집
    • /
    • 제4권1호
    • /
    • pp.30-37
    • /
    • 2001
  • The experimental study on the effect of axial clearance between the tip of impeller blades and stationary shroud has been performed. The investigated compressor, which is a part of a small auxiliary power unit engine, consists of a curved inlet, a centrifugal impeller, a channel diffuser and a plenum chamber. It was designed for a total pressure ratio of 4.3 and an efficiency of $77\%$ at design speed of 60,000 rpm. The experiments are carried out in an open-loop centrifugal compressor test rig driven by a turbine. For the four different clearance ratios Cr(clearance/impeller tip width) of 6.25, 10.93, 15.60 and 20.30 percent, the overall performance data are obtained at $97\%,\;90\%$ and $80\%$ of the design speed. The results show the overall pressure ratio decrease of $7.7\%$ and the efficiency loss of $8.7\%$ across the variation of clearance ratio near the design speed. It also indicates that the influence of tip clearance became weaker as the flow rate is reduced and the stable operating range is not significantly influenced by the change of clearance ratio.

  • PDF

Vane Pump의 유동 특성에 대한 수치 해석 (Numerical Analysis on Flow Characteristics of a Vane Pump)

  • 이상혁;진봉용;허남건
    • 한국유체기계학회 논문집
    • /
    • 제10권1호
    • /
    • pp.34-40
    • /
    • 2007
  • In this study, the characteristic of a vane pump of automotive power steering system is numerically analyzed. The vane pump changes the energy level of operation fluid by converting mechanical input power to hydraulic output. To simulate this mechanism, moving mesh technique is adopted. As a result, the flow rate and pressure are obtained by numerical analysis. The flow rate agrees well with the experimental data. Moreover, the variation and oscillation of the pressure around the rotating vane are observed. As a result of flow characteristics, The difference of pressure between both side of vane tip causes the back flow into the rotor. As the rotational velocity increases, the flow rate at the outlet and the pressure in the vane tip rises with higher amplitude of oscillation. In order to reducing the oscillation, the design of devices for decreasing the cross-area of the outlet part and returning the flow from the outlet to the inlet is required.

차량 및 산업설비 폐열회수용 열전발전시스템의 최적 열교환 시스템에 관한 실험적 연구 (Experimental Study on the Optimal Heat Exchanger of Thermoelectric Generation System for Industrial and Automobile Waste Heat Recovery)

  • 정재훈;김우철;이진호;류태우
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.460-463
    • /
    • 2008
  • A large part of the overall industrial energy is dissipated as waste heat despite of much development in the utilization of thermal energy. A mean efficiency is reported to be only around 30 to 35%. The existing waste heat recovery technology has reached its limit and consequently, the development of a new technology is necessary. Improving efficiency using thermoelectric technology has recently come into the spotlight because of its unique way to recover thermal energy. In fact, thermoelectric generator directly converts thermal energy into electric energy by a solid state without any moving parts. Futhermore remarkable improvement in the thermoelectric energy conversion efficiency has been achieved. In this study, a thermoelectric generator was made using commercialized thermoelectric modules. With thermoelectric modules attached on a duct surface, hot air was blown into the duct using a hot air blower. On the other side of the module, a water jacket was attached to cool the module. With different air inlet temperatures and water flowrates, the electrical power of the thermoelectric generator was measured.

  • PDF