• 제목/요약/키워드: Inlet Humidity Condition

검색결과 47건 처리시간 0.021초

캐소드극 입구 가습 조건이 고분자 전해질 연료전지의 성능에 미치는 영향 (Effect of Inlet Humidity Condition at Cathode Side on Performance of a Polymer Exchange Membrane Fuel Cell)

  • 문철언;이서희;고동수;양장식;최경민;김덕줄
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3423-3428
    • /
    • 2007
  • This paper shows that inlet humidity condition at cathode side is one of dominant parameters affecting the performance of PEMFC. To investigate effects of inlet humidity condition, the performance measurements were conducted for a single PEMFC with two operating variables : cathode relative humidity and dry condition in anode dry. The fuel cell employed for the experiments is a unit PEMFC with a 25$Cm^2$, Nafion$^(R)$112 membrane. As a result of this study, the cell performance is getting higher by increasing inlet humidity condition at cathode side. The cell performance is different from each operating temperature an it has maximum30% higher than dry condition at 60$^{\circ}C$ operating temperature with 80% relative humidity.

  • PDF

전산해석을 통한 고분자 전해질 연료전지 내 입구 가습조건의 영향에 관한 연구 (Numerical Study for the Effect of Inlet Humidity Condition at PEMFC Channel)

  • 이동율;;배중면
    • 대한기계학회논문집B
    • /
    • 제30권12호
    • /
    • pp.1228-1235
    • /
    • 2006
  • PEMFC(Proton Exchange Membrane Fuel Cell) is a low temperature fuel cell and has many probabilities of commercial use. However, water management is one of the serious technical problems for commercialization. It is necessary to understand the relationship between operation conditions and water behavior in PEMFC channel because it affects fuel cell performance. In this paper, the distribution of current density according to inlet humidity condition is mainly observed and discussed. If the anode inlet is well humidified, electro-osmotic drag is very active. For this reason, current density is very high at inlet side and the distribution is non-uniform.

입구 가습량이 고분자 전해질 연료전지의 성능에 미치는 영향에 대한 CFD 해석연구 (Computational fluid dynamics analysis on the effect of inlet humidity for the performance of PEMFC with serpentine flow-fields)

  • 오규환;이규진;남진현;김찬중
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2828-2833
    • /
    • 2008
  • Water management is one of many operating parameters, which influences the performance and stability of a proton exchange membrane fuel cell (PEMFC). Local humidity condition including liquid water saturation has profound impacts on the distributions of overpotentials, current density, and membrane water content. Computational fluid dynamics simulations were conducted to investigate the effect of the inlet humidity variation on the performance of a PEMFC of $9\;cm^2$ active cell area with serpentine flow fields. The results showed that the performance of the simulated PEMFC remained at an almost same level when the cathode inlet humidity was changed from 100% to 60%, while reaching its maximum at air humidity of 80%. However, further decrease in the cathode inlet humidity below 40% started to significantly deteriorate the performance of the PEMFC. The variations of overpotentials, membrane water content, etc. due to the change in the cathode inlet humidity were also discussed.

  • PDF

증발기의 압력강하에 대한 상대습도의 영향 (Effects of Relative Humidity on the Evaporator Pressure Drop)

  • 김창덕;강신형;박일환;이진호
    • 설비공학논문집
    • /
    • 제16권5호
    • /
    • pp.397-407
    • /
    • 2004
  • It is well known that some key parameters, such as evaporating temperature, refrigerant mass flow rate, face velocity and inlet air temperature, have significant influence on the evaporator performance. However performance studies related to a humid environment have been very scarce. It is demonstrated that the refrigerant mass flow rate, heat flux, water condensing rate and air outlet temperature of the evaporator significantly increase with air inlet relative humidity. As the air inlet relative humidity increases, the latent and total heat transfer rates increase, but the sensible heat transfer rate decreases. The purpose of this study is to provide experimental data on the effect of air inlet relative humidity on the air and refrigerant side pressure drop characteristics for a slit fin-tube heat exchanger. Experiments were carried out under the conditions of inlet refrigerant saturation temperature of 7 $^{\circ}C$ and mass flux varied from 150 to 250 kg/$m^2$s. The condition of air was dry bulb temperature of 27$^{\circ}C$, air Velocity Varied from 0.38 to 1.6 m/s. Experiments Showed that air Velocity decreased 8.7% on 50% of relative humidity 40% of that at degree of superheat of 5$^{\circ}C$, which resulted that pressure drop of air and refrigerant was decreased 20.8 and 8.3% for 50% of relative humidity as compared to 40%, respectively.

착상조건하에서 핀-관 열교환기 성능에 관한 실험적 연구 (An Experimental Study on the Performance of Fin-Tube Heat Exchanger under Frosting Condition)

  • 이관수;박희용;이태희;이남교;이수엽;이명렬
    • 설비공학논문집
    • /
    • 제7권2호
    • /
    • pp.319-328
    • /
    • 1995
  • In this study, the experiment with 2rows-2columns fin-tube heat exchanger under forced convection and frosting condition is performed. The influence of each operating condition(the temperature of air, the humidity of air, the velocity of air, the temperature of coolant) on the growth of frost layer, air-side pressure drop, and characteristics of heat transfer is investigated. The experimental results show that the frost thickness increases rapidly in the early stage of frost formation and increases linearly after sometime. The frost thickness increases with the increase of the inlet air humidity and velocity and the decrease of inlet air temperature and coolant temperature. It is also found that the total energy transfer rate increases with the increase of inlet air temperature and velocity and with the decrease of inlet air humidity and coolant temperature.

  • PDF

산소 가습이 PEMFC 성능에 미치는 영향 (Influence of the inlet oxygen humidity on PEMFC performance)

  • 이서희;문철언;고동수;최경민;김덕줄;정지환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.35-38
    • /
    • 2007
  • The comparisons between measured performance of lab-scale PEMFC and calculation were conducted to understand the detail phenomena of PEMFC for the various inlet oxygen humidity of cathode side. Experiments were performed at $65^{\circ}C$ operation temperature and different inlet humidity conditions such as 40%, 60% and 80%. We used the MEA manufactured by oneself which include $Nafion^{(R)}$ 112 membrane, Nafion solution 20%, and carbon paper(E-TEK). As a result of this experiment, cell performance was getting higher by increasing inlet humidity condition at cathode side because ion conductivity of electrolyte membrane is increased. A 3D CFD simulation model of PEMFC was developed using commercially available CFD code that is one of the STAR-CD module, es-pemfc under same operating conditions. Model calculations results were compared with experimental ones on the polarization curves and calculation results are in good agreement with the experimental ones. Local water distribution and current density inside PEMFC are discussed in detail.

  • PDF

차량용 에어컨의 성능에 미치는 인자에 관한 연구 (Parametric Study on Performance of an Automobile Air Conditioner)

  • 박윤철;권기린
    • 동력기계공학회지
    • /
    • 제6권4호
    • /
    • pp.16-22
    • /
    • 2002
  • This study was conducted to find performance evaluation method for automobile air conditioner. Experimental facilities were constructed to simulate wide range of operating condition for the automobile air conditioner. Compressor speed was controled by variable speed electric motor and the power was measured through torque transducer and tachometer was used to measure compressor speed. Parametric studies were conducted in this study, to figure out effect of environment variables on the performance of the automobile air conditioner. The environmental variables are inlet air temperature, relative humidity and air flow rate for the evaporator and inlet air temperature and air flow rate for the condenser. Compressor speed is also changed. The results of this study shows that air flow rate of the evaporator is more sensitive to the performance of the automobile air conditioner than the other variables. However relative humidity of the inlet air of the evaporator strongly affects capacity rather that COP.

  • PDF

Methodology to Simultaneously Optimize the Inlet Ozone Concentration to Oxidize NO and Relative Humidity Composition for the $NO_x$ Degradation using Soil Bio-filter

  • Cho, Ki-Chul;Hwang, Kyung-Chul
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제24권E2호
    • /
    • pp.83-91
    • /
    • 2008
  • This work investigated the methodology to simultaneously optimize the ozone and relative humidity composition for the $NO_x$ degradation using soil biofilter. Experiments were made as a function of inlet ozone concentration ($0{\sim}1,770\;ppb$) and relative humidity ($38{\sim}81%$). Factorial design ($2^2+3$) and response surface methodology by central composite designs were used to examine the role of two factors and optimal response condition on $NO_x$ degradation. It was found that a second-order response surface model can properly interpret the experimental data with an $R^2$-value of 0.9730 and F-value of 71.83, based on which the maximum $NO_x$ degradation was predicted up to 92.8% within our experimental conditions.

PEMFC 1차원 시뮬레이션 검증을 위한 실험적 연구 (An Experimental Study of Verification for PEMFC's 1-Dimensional Simulation)

  • 문철언;안성율;양장식;최경민;김덕줄
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.191-195
    • /
    • 2007
  • In this study, we estimated the performance of PEMFC's unit cell as changing operating temperature in different inlet humidity condition at cathode side but anode dry, and tried to match experimental results with 1-dimensional simulation. We used $Nafion^{\circledR}112$ membrane and a self-manufactured PEMFC with active area of $25cm^{2}$ was used in this study. The range of operating temperature was $40{\sim}70^{\circ}C$ and oxygen through bubbled humidity chamber was supplied $0{\sim}80$% humidity condition as changing water temperature in humidity chamber. For figuring out governing equations, represent water contents in electrolyte membrane, the linear forward difference method was applied about time progress and quadratic central difference method was used about space progress. It was assumed that pressure terms were linearly changed due to thin electrolyte membrane. In low operating temperature condition, $40{\sim}60^{\circ}C$, increasing temperature rarely effected cell performance but we can see performance drop at $70^{\circ}C$. By modifying Henrry's constant and/or diffusion coefficient, the modified one-dimensional model was accomplished for calculation.

  • PDF

습도가 엔진성능에 미치는 영향에 대한 실험적 고찰 (Study on the Humidity Effect on Gas turbine Engine Performances)

  • 이보화;이경재;양수석;김춘택
    • 항공우주기술
    • /
    • 제9권2호
    • /
    • pp.98-104
    • /
    • 2010
  • 대기 중의 수증기는 가스터빈엔진의 주요성능에 많은 영향을 끼친다. 습공기의 영향은 기온 및 기압이 높은 여름철 해면 고도, 높은 비행 마하수 그리고 낮은 엔진 회전수에서 이 더욱 두드러진다. 이러한 습공기 유입에 따른 가스터빈 엔진의 성능변화의 정도를 살펴보고자 가스터빈 시뮬레이션 프로그램(GSP)과 200lbf 급 초소형 터보제트 엔진의 고공환경 성능시험을 통해 습도가 엔진성능에 미치는 영향에 대하여 알아보았다. 고공환경 엔진시험을 통해, 건공기 유입에 비해 습공기 유입 시 순추력에서 2.826% 낮게, 비연료소모율에서 1.325% 높게 측정되었다.