• 제목/요약/키워드: Inlet Flow Condition

검색결과 457건 처리시간 0.027초

플라즈마 충진 촉매 시스템을 이용한 에틸렌 저감 연구 (Decomposition of Ethylene using a Hybrid Catalyst-packed Bed Plasma Reactor System)

  • 이상백;조진오;장동룡;목영선
    • 한국대기환경학회지
    • /
    • 제30권6호
    • /
    • pp.577-585
    • /
    • 2014
  • A series of experiments using atmospheric-pressure non-thermal plasma coupled with transition metal catalysts were performed to remove ethylene from agricultural storage facilities. The non-thermal plasma was created by dielectric barrier discharge, which was in direct contact with the catalyst pellets. The transition metals such as Ag and $V_2O_5$ were supported on ${\gamma}-Al_2O_3$. The effect of catalyst type, specific input energy (SIE) and oxygen content on the removal of ethylene was examined to understand the behavior of the hybrid plasma-catalytic reactor system. With the other parameters kept constant, the plasma-catalytic activity for the removal of ethylene was in order of $V_2O_5/{\gamma}-Al_2O_3$ > $Ag/{\gamma}-Al_2O_3$ > ${\gamma}-Al_2O_3$ from high to low. Interestingly, the rate of plasma-catalytic ozone generation was in order of $V_2O_5/{\gamma}-Al_2O_3$ > ${\gamma}-Al_2O_3$ > $Ag/{\gamma}-Al_2O_3$, implying that the catalyst activation mechanisms by plasma are different for different catalysts. The results obtained by varying the oxygen content indicated that nitrogen-derived reactive species dominated the removal of ethylene under oxygen-lean condition, while ozone and oxygen atoms were mainly involved in the removal under oxygen-rich condition. When the plasma was coupled with $V_2O_5/{\gamma}-Al_2O_3$, nearly complete removal of ethylene was achieved at oxygen contents higher than 5% by volume (inlet ethylene: 250 ppm; gas flow rate: $1.0Lmin^{-1}$; SIE: ${\sim}355JL^{-1}$).

가변안내깃 설치각이 다단 축류압축기 성능에 미치는 영향 (Effects of Variable Guide Vane Setting Angle on the Performance of Multi-Stage Axial Compressor)

  • 박준영;서정민;임형수;최범석;최태우;최재호
    • 한국추진공학회지
    • /
    • 제20권5호
    • /
    • pp.9-18
    • /
    • 2016
  • 일반적으로 다단 축류압축기는 부분 부하 조건에서 충분한 운전영역을 확보하기 위해 가변안내깃을 이용한다. 본 연구에서의 해석대상인 다단 축류압축기는 입구에서의 안내깃과 함께 1단과 2단 정익을 가변안내깃으로 하여 운전영역을 확보한다. 따라서 본 연구에서는 정격회전수의 70%와 90% 회전수 조건에서의 가변안내깃의 설치각이 다단 축류압축기의 성능에 미치는 영향에 대해 조사하였다. 다단 축류압축기의 성능은 3차원 정상상태 및 비정상상태 수치해석을 이용하여 확보하였다. 각 해석기법을 통해 확보한 결과를 비교하였으며 내부유동장의 특성을 파악하였다.

벤치 연비 모사 조건에서 차량용 에어컨 압축기의 특성에 관한 연구 (Study on Characteristics of Car Air-con Compressor Under Bench System Fuel Economy Simulation Condition)

  • 유성연;김영신
    • 대한기계학회논문집B
    • /
    • 제36권7호
    • /
    • pp.705-710
    • /
    • 2012
  • 본 연구에서는, 차량용 에어컨 시스템으로 구성된 벤치 장비에서의 실험을 통하여 에어컨 관련 북미 실차 연비 평가 모드 중의 하나인 SC03 모드 연비 평가의 벤치 모사 시험 가능성을 검증하였다.본 연구에 사용된 설비는 차량용 에어컨 시스템을 실차 조건처럼 구성할 수 있는 각각의 챔버로 구분되어져 있으며, 외부 환경을 재연할 수 있도록 온도와 습도, 풍속을 제어할 수 있도록 구성하였다. 지금까지 실차 환경 풍동에서 평가 되어지던 SC03 모드 연비 평가에 대하여 시스템 벤치에서 모사가 가능하도록 실차에서 가장 중요한 변수인 차속과 차량 전면 풍속에 대응하는 압축기 회전수와 응축기 전면풍속에 대한 신뢰성을 확보하였다.이를 바탕으로 다양한 토출 용량을 가지는 압축기를 가지고 에어컨 시스템 벤치 장비에서 SC03 연비 모사 실험을 수행하여, 압축기 토출량의 차이에 따른 연비의 차이가 특징 지어지는 것을 확인하였다.

Numerical simulation and experimental study of non-stationary downburst outflow based on wall jet model

  • Yongli Zhong;Yichen Liu;Hua Zhang;Zhitao Yan;Xinpeng Liu;Jun Luo;Kaihong Bai;Feng Li
    • Wind and Structures
    • /
    • 제38권2호
    • /
    • pp.129-146
    • /
    • 2024
  • Aiming at the problem of non-stationary wind field simulation of downbursts, a non-stationary down-burst generation system was designed by adding a nozzle and program control valve to the inlet of the original wall jet model. The computational fluid dynamics (CFD) method was used to simulate the downburst. Firstly, the two-dimensional (2D) model was used to study the outflow situation, and the database of working conditions was formed. Then the combined superposition of working conditions was carried out to simulate the full-scale measured downburst. The three-dimensional (3D) large eddy simulation (LES) was used for further verification based on this superposition condition. Finally, the wind tunnel test is used to further verify. The results show that after the valve is opened, the wind ve-locity at low altitude increases rapidly, then stays stable, and the wind velocity at each point fluctuates. The velocity of the 2D model matches the wind velocity trend of the measured downburst well. The 3D model matches the measured downburst flow in terms of wind velocity and pulsation characteris-tics. The time-varying mean wind velocity of the wind tunnel test is in better agreement with the meas-ured time-varying mean wind velocity of the downburst. The power spectrum of fluctuating wind ve-locity at different vertical heights for the test condition also agrees well with the von Karman spectrum, and conforms to the "-5/3" law. The vertical profile of the maximum time-varying average wind veloci-ty obtained from the test shows the basic characteristics of the typical wind profile of the downburst. The effectiveness of the downburst generation system is verified.

다단 환원형 유동층에서 J-valve의 운전변수에 따른 고체 흐름량 및 기체 우회 (Solid Flow Rate and Gas Bypassing with Operating Variables of J-valve in Multistage Annular Type Fluidized Beds)

  • 흥윤석;강경수;박주식;이동현
    • 청정기술
    • /
    • 제17권1호
    • /
    • pp.62-68
    • /
    • 2011
  • 다단 환원형 유동층 반응기(상승관: $0.01{\times}0.025{\times}2.8m^3$, J-valve: $0.009{\times}0.015m^2$)에서의 수력학적 특성을 연구하였다. 층물질로는 glass beads($d_p=101{\mu}m$, ${\rho}_b=1,590kg/m^3$, $U_{mf}=1.25{\times}10^{-2}m/s$, Galdart B)를 사용하였다. Batch 상태에서 고체흐름량을 측정하기 위하여 전자저울을 사용하여 누적된 무게로 계산하였다. 연속공정에서는 고체순환량를 측정하기 위하여 고체가 순환상태에서 사이클론 하단의 3-way 밸브를 이용하여 일정시간에 누적된 무게로 계산하였다. 또한 정상상태에서 가열된 입자가 열전대를 통과하는 시간을 측정하여 고체순환량을 계산하였다. 고체의 흐름량은 주입 기체의 유속($1.2{\sim}2.6U_{mf}$)과 층높이(z, 0.24~0.68 m)가 증가함에 따라 2.2 에서 23.4 kg/s로 증가하였다. 이때 고체체류시간은 440에서 1,438 s까지 변화하였다. 상승관내의 고체 체류량을 확인하기 위하여 각 구간에서의 압력강하를 측정하여 고체 체류량을 계산하였다. 본 연구에서 얻어진 고체체류량 분포는 end effect를 갖는 exponential decay model 의 형태로 나타났다. 상단 유동층에서 중단 유동층으로의 기체 우회을 확인하기 위하여 상단 유동층으로 주입되는 공기에 일정 조성의 $CO_2$ 추적기체를 주입한 후, 기체분석기를 이용하여 중단 유동층의 배출기체중 $CO_2$가 우회되는 양을 측정하였다. 측정된 기체우회(gas bypassing)양은 2.6% 미만으로 그 영향이 크지 않는 것으로 판단하였다.

토네이도 블록형 선회류 침사제거기의 침사제거효율 평가 (Evaluations of Grit Removal Efficiency of Tornado Block-Type Vortex Grit Separator)

  • 김종제;이범수;염철민;임희재;정석모
    • 상하수도학회지
    • /
    • 제19권3호
    • /
    • pp.288-294
    • /
    • 2005
  • This study was conducted to evaluate the grit removal efficiency of tornado block-type vortex grit separator. Vortex grit separator was manufactured for this study, and it was characterized by the impeller and tornado block installed in separator. Impeller was installed to increase water velocity in the separator and tornado block was installed to increase the grit lifting efficiency. Pilot study was also conducted in A sewage treatment plant (STP) in Gyeonggi province from November 2003 to May 2004 (64 days). Major findings are as follows. 1. Impeller was proven to increase water velocity in the grit separator, especially in low flow rate. This influence will increase separation ratio of organics from grits, preventing those organics from sedimentation. 2. Sand (with 0.2~0.3mm size) removal efficiency was over 98 % and 96 %, at the flow rate of $500m^3/day$ and $750m^3/day$ under the condition that impeller rotation velocity kept at 15 rpm. Originally that grit separator was designed to have the capacity of $500m^3/day$. $750m^3/day$ was tried to investigate the performance of this type of grit separator under overload condition. Stable grit removal was still available to the extent of 150% of designed capacity. 3. It took less than 3 minutes for the grit separator to completely lift out 3 kgs of 0.2-0.3 mm sized, settled sand at the bottom to 2,060 mm high above water surface. But it showed the tendency to spend a little more time on lifting the grit as the grit size and the vertical height of the lift increased. 4. During experimental duration in A STP, it was found that the average amount of inlet grit was about 981 g/day (160~1,685 g/day) under $500m^3/day$ of operation condition, but it varied so severely during the experimental duration. After classification of discharged grit according to its size, grit with 0.3-0.42 mm size was found as largest part of output.

다양한 배플 인자에 따른 셀-튜브 열교환기의 열전달 및 압력강하 특성에 관한 수치해석 (Numerical analysis for heat transfer and pressure drop characteristics of )

  • 후영영;박형선;윤준규;임종한
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권4호
    • /
    • pp.367-375
    • /
    • 2014
  • 셀-튜브 열교환기는 산업분야에서 가장 널리 사용되는 열교환기이다. 열교환기의 열적 성능을 개선하기 위하여 셀-튜브 열교환기에 대해 배플의 배치, 배플의 방향, 배플의 표면의 돌기형상 등의 인자를 변경하였으며, 유동의 박리 및 경계층해석에 적절히 이용되는 SST 난류모델을 적용하여 열전달특성을 고찰하였다. CFD해석시 경계조건는 셀측의 입구온도를 344K로 일정하게 하고, 물의 유량을 6, 12, 18, 24 l/min로 변화시켰다. 그 결과로는 지그재그형 배치가 열전달률 및 압력강하가 향상되는 것으로 나타났으며, 배플의 방향은 기존형보다 수직형 및 각도 $45^{\circ}$형이 열전달이 향상되는 것으로 나타났고, 압력강하는 거의 차이가 없었다. 또한 배플의 돌기형상은 열전달면적을 증가시킴으로써 열전달률 및 압력강하가 향상됨을 알 수 있었다. 해석결과를 통하여 열전달 증가가 유동의 박리, 유체의 체류시간, 튜브와의 접촉면적, 유량, 와류 등에 따라 크게 영향을 받는다는 것을 알 수 있었다.

소화전과 이토변을 이용한 플러싱 적용 시 관 내 세척유량과 유속 모의 방안에 관한 연구 (A study on the simulation method for the flushing flowrate and velocity in the watermain using a hydrant and a drain valve)

  • 김아린;이은환;이송이;김광현;전환돈
    • 한국수자원학회논문집
    • /
    • 제55권spc1호
    • /
    • pp.1251-1260
    • /
    • 2022
  • 최근 상수관망은 노후화 및 관 내 스케일의 박리로 인해 적수 사고등 수질사고가 지속적으로 발생하고 있다. 관내 퇴적되어있는 스케일은 평상시엔 안정화되어 문제를 야기하지 않지만, 상수관망 시스템의 급격한 유속 및 유향 변화 등에 의해 발생하는 수충격에 의해 박리된 후 수용가로 유입되며 수질사고를 야기한다. 이를 사전에 방지하기 위해서는 주기적인 관세척으로 스케일을 제거할 필요가 있다. 관세척공법 중 가장 보편적으로 사용되는 방법은 플러싱으로 현재 국내·외에서 관세척을 위한 유속 및 세척기준 연구가 활발하게 진행되고 있다. 하지만, 플러싱 공법 적용 시 적정유속 기준에 관한 연구가 주로 진행되어, 세척시 관내 적정유속 확보여부를 사전에 검토하기 위한 구체적인 방안에 관한 연구는 미흡한 실정이다. 관 세척시 용수는 소화전 또는 이토변을 통과하면서 주손실과 미소손실이 발생하며, 이는 관 내 유속에 영향을 미치는 요인으로 세척효과 분석에 직접적인 영향을 준다. 이에 본 연구는 Minorloss Coefficient와 Emitter Coefficient를 적용한 모의를 통해 플러싱 적용 시 관 내 유속을 분석하는 수리해석 방법을 제안하였다. 제안한 방법을 예시관망과 A시 일부구역에 적용하여 적절성을 검토하고, 소화전과 이토변의 세척효과를 비교하였다. 적용 결과 소화전을 통과하는 수리학적 조건을 고려하지 않은 경우, 실제 발생하는 손실을 고려하지 못해 소화전에서 방출 가능한 유량 대비 큰 유량과 유속이 산출되는 결과를 보였고, 이토변의 경우는 긴 세척구간에도 세척유속과 유량의 확보가 용이하여 소화전에 비해 시간적. 효율적으로 큰 세척효과가 있을 것으로 판단하였다. 하지만, 실제 상수관망의 적용 시 이토변은 소화전에 비해 설치 개수가 적어 적용이 제한적이다. 이와같은 특성을 이해하여 실무자의 판단과 대상지역의 특징에 따라서 적절한 세척계획을 수립하는 것이 필요할 것으로 판단된다.

지반내 입자거동 및 흐름을 고려한 수압작용 모델링 (Fluid Injection Simulation Considering Distinct Element Behavior and Fluid Flow into the Ground)

  • 전제성;김기영
    • 한국지반공학회논문집
    • /
    • 제24권2호
    • /
    • pp.67-75
    • /
    • 2008
  • 개별요소방법은 재료의 미시적 거동 및 불연속적 거동과 관련하여 지반공학 분야에서 그 활용이 증가하고 있으나, 기존 개별요소 방법들은 입자형태의 재료들간 상호작용을 위주로 연구되었으며, 이는 지반공학 분야에 개별요소 방법을 제한적으로 적용하는 주요 원인이 되었다. 최근 기존 개별요소 방법에 흙, 암반 및 투수성 매질에서의 물 흐름을 고려한 수리연동 기법의 적용연구(Kawaguchi et al., 2003; Shimizu, 2004)가 진행되고 있다. 본 연구에서는 기존 개별요소방법에 수리연동 기법을 적용하여 수압조건별 지반의 공동생성 및 확장에 대한 수치해석을 실시하였다. 직사각형 해석요소에 입자크기와 초기 간극률 조건에 대한 개별요소 및 경계면 생성 후, 서보 제어방법을 통한 경계면 응력조건을 구현하였다. 수리거동의 고려는 연속방정식과 Navier-Stokes 방정식을 이용하여 압력과 속도를 구한 후, 입자와 유수간의 상호작용을 풀어가는 방식(Tsuji, 1993)으로 수행하였다. 구속압 조건($0.1MP{\alpha},\;0.5MP{\alpha}$)에 대하여 해석모델 중앙지점에 7단계로 증가되는 수평방향 유속을 재하하고, 재하지점 인근의 개별요소 이동 및 지점별 유량, 유속, 압력, 경계면 응력변화 등을 분석하였으며, 해석조건에 따라 개별요소와 수리 영향의 상호거동을 통한 공동생성 및 확장, 한계압력 발생 등을 확인하였다.

작동 조건에 따른 고온 고분자 전해질 연료전지의 성능 변화에 대한 전산해석 연구 (Numerical Study of Effects of Operating Conditions on the Performance of High Temperature PEMFC)

  • 김경연;손영준;김민진;양태현
    • 전기화학회지
    • /
    • 제13권4호
    • /
    • pp.283-289
    • /
    • 2010
  • 2차원 전산 해석 모델을 사용하여 고온 고분자 전해질 연료전지의 전산해석을 수행하였다. 해석 모델은 기존의 실험데이터와의 비교를 통해 검증하였으며, 다양한 작동 조건이 연료전지의 성능에 미치는 영향을 파악하기 위해 일련의 전산해석을 수행하였다. 본 전산해석의 결과를 통해 교환전류밀도, 이온전도도, 공급유량 및 작동압력이 증가할수록 연료전지의 성능이 향상됨을 확인하였다. 또한, 기체 확산층의 기공율이 높을수록 기체의 확산이 향상되어 연료전지의 성능이 향상되었으며, 양극 기체 확산층의 기공율에 의한 효과가 음극에 비해 더 두드러지게 나타났다.