• Title/Summary/Keyword: Inlet/Outlet Location

Search Result 55, Processing Time 0.02 seconds

Optimal Design of a Parallel-Flow Heat Exchanger by Using a Response Surface Method (반응표면법을 이용한 평행류 열교환기의 설계인자 최적화)

  • Oh, Seok-Jin;Lee, Kwan-Soo
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1028-1033
    • /
    • 2004
  • The heat and flow characteristics in a single-phase parallel-flow heat exchanger was examined numerically to obtain its optimal shape. A response surface method was introduced to predict its performance approximately with respect to design parameters over design domain. Design parameters are inflow and outflow angle of the working fluid and horizontal and vertical location of inlet and outlet. The evaluation of the relative priority of the design parameters was performed to choose three important parameters in order to use a response surface method. A JF factor was used as an evaluation characteristic value to consider the heat transfer and the pressure drop simultaneously. The JF factor of the optimum model, compared to that of the base model, was increased by about 5.3%.

  • PDF

Heat Transfer Analysis of EGR Cooler with Different Tube Shape (튜브형상에 따른 배기가스 재순환 냉각 장치 열전달 성능 평가)

  • Sohn, Chang-Hyun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.5
    • /
    • pp.112-117
    • /
    • 2007
  • With the Euro-4 regulation coming into effect, the domestic car industry is forced to look for newer options to reduce NOX in the exhaust. EGR(Exhaust Gas Recirculation) Cooler is an effective method for the reduction of NOX form a diesel engine. High efficiency, low pressure loss and compactness are desirable features of an EGR Cooler. The cooling performance of EGR depends on the shape of tubes and the location of the entrance and exit. This paper reports the computational work conducted to estimate the performance of EGR cooler with three different cross section tubes and a triangular spiral tube. Three dimensional computation results show that the triangular tube is more effective than circular and rectangular tube. The most effective geometry is a triangular spiral tube with offset inlet and outlet locations.

Dynamic and Static Characteristics of Sensor Tube for Mass Flow Controller (질량유량제어기용 센서튜브의 정특성과 동특성에 관한 연구)

  • 김영수;이상경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.3
    • /
    • pp.531-537
    • /
    • 2004
  • In this paper, the static and dynamic characteristics in the sensor tube of a mass flow controller(MFC) were studied by experiments. In the sensor tube of MFC. the difference of temperature between inlet and outlet was necessary for calculating the mass flow rate. Therefore, the relations among flow rate, heat generated by heating wire. and sensor location were investigated to find optimized condition. Finally, the relation between sensor voltage through analog digital conversion(ADC) and flow rate in the sensor tube can be represented. Based on this study, static and dynamic characteristics of sensor tube can be used for design of mass flow controller.

Numerical Prediction of Open Water Performance of Flapped Rudders

  • Pyo, S.W.;Suh, J.C.
    • Journal of Ship and Ocean Technology
    • /
    • v.4 no.1
    • /
    • pp.1-10
    • /
    • 2000
  • A low-order potential based boundary element method is applied for the prediction of the performance of flapped rudders as well as all-movable rudders in steady inflow. In order to obtain a reasonable solution at large angles of attack, the location of the trailing wake sheet is determined by aligning freely with the local flow. The effect of the wake sheet roll-up is also included with use of a high order panel method. The flow in the gap of a flapped rudder is modeled as Couette flow and its effect is introduced into the kinematic boundary conditions for flux at both the inlet and the outlet of the gap. In order to validate the present method, the method is applied for a series of rudders and the computational results on forces and moments are compared with experimental data. The effect of the gap size on the forces and moments is also presented.

  • PDF

Evaluation of Indoor Air Environment by Changing Diffuser Location and Air Temperature with Under Floor Air Conditioning System (바닥취출 및 흡입시스템 공조방식에서 취출조건 변경시 실내공기환경 평가)

  • Kim Se-hwan;Park Jong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.5
    • /
    • pp.397-403
    • /
    • 2005
  • The thermal comfort of occupants is directly related to several environmental factors such as velocity of air flow, turbulence intensity and temperature distribution of indoor air. The purpose of this study is to evaluate the indoor air flow and temperature distribution in office area using under-floor air-conditioning system (UFAC System) based on the results from physical measurements and to perform a Computer Fluid Dynamics (CFD) under the same condition of inlet and outlet as field measurement. The results from the CFD simulation are similar to those from the field measurement. The results show that UFAC system is provide proper indoor condition for occupants.

A Numerical Analysis for the Performance Improvement of a Channel Heat Exchanger (채널형 열교환기의 성능향상에 관한 수치해석)

  • Jang, Byung-Hyun;Kim, Si-Peom;Lee, Kwon-Hee
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.2
    • /
    • pp.159-164
    • /
    • 2012
  • The shell & tube heat exchanger is used throughout various industries because of its inexpensive cost and handiness when it comes to maintenance. However, it has many design elements such as the location and the shape of inlet and outlet, the numbers of tubes and baffles, etc. Also, the flow within the shell and the heat transfer are complex. This paper is performed numerical analysis to evaluate capabilities of difference in temperature and pressure drop, which are the performance of channel heat exchanger, one of different types of shell & tube exchanger. Also, factors that affect the performance of channel heat exchanger were selected through design of experiment along with key factors.

A Study of Heat Transfer Phenomena in a Sensor Tube of a Mass Flow Controller (질량흐름 제어기의 센서 튜브에서 열전달현상에 관한 연구)

  • Lee, S.K.;Kim, Y.S.
    • Journal of Power System Engineering
    • /
    • v.7 no.3
    • /
    • pp.35-39
    • /
    • 2003
  • In this paper, the heat transfer phenomena in the sensor tube of a mass flow controller(MFC) were studied by experiments. In the sensor tube of MFC, the difference of temperature between inlet and outlet was necessary for calculating the mass flow rate. Therefore, the relations of flow rate, generated heat by heating wire, sensor location and tube thickness were investigated to find the optimized condition. Based on this study, static and dynamic characteristics of sensor can be used for mass flow controller.

  • PDF

The Developmental Stages of the Circumstances and Characteristics in Wentland - In the Gyunggi Do Mountains -

  • Moon, Hyun-Sook
    • Journal of the Speleological Society of Korea
    • /
    • no.69
    • /
    • pp.49-60
    • /
    • 2005
  • This Study is about the wetlands in the GyunggiDo Mountains. It is written in the point of the hydrogeomorphology, geology, and soil. And it has accessed to ecological environment. Wetlands are divided into mountain wetlands and river wetlands by location, relief, processes, hydrology, and the type of inlet and outlet of water in wetlands. Mostly mountain wetlands are formed by the process of destruction of mountain slope. So they are to be located in the knickpoint. Therefore the underground surface is visible and underground water is rising or leaking. At this process, the environment forming wetlands are made by soil that was influenced by geology and composed by fine and very fine granules.

Hydrogen Absorption Behavior of Zr-2.5Nb Pressure Tubes in Wolsong Unit 1

  • Choo, Kee-Nam;Kwon, Sang-Chul;Kim, Young-Suk
    • Nuclear Engineering and Technology
    • /
    • v.30 no.4
    • /
    • pp.318-327
    • /
    • 1998
  • The deuterium uptake behavior of Zr-2.5Nb pressure tubes in Wolsong Unit 1 was analyzed in terms of longitudinal location, operation time, and coolant temperature. The results were compared with those obtained from Canadian CANDU reactors. The amount of deuterium uptake was higher at the outlet part than at the inlet part and was also higher when subjected to a longer operation time and a higher coolant temperature. The hydrogen uptake of Zr-2.5Nb in a hydrogen gas atmosphere was dependent on the microstructure of the alloy. The aged Zr-2.5Nb consisting of $\alpha$-Zr and $\beta$-Nb phases showed higher hydrogen uptake than that consisting of $\alpha$-Zr and $\beta$-Zr phases. The hydrogen in the alloy decreased the rate of oxidation. This could be explained in terms of the cathodic controlled reaction of Zr-2.5Nb oxidation.

  • PDF

Prediction of Transmission Loss of Elliptic Expansion Chamber with Mean Flow by 3-Dimensional Finite Element Method (3차원 유한요소법을 이용한 타원 단면 소음기의 투과 손실 계산)

  • 윤성기;이응식
    • Journal of KSNVE
    • /
    • v.3 no.3
    • /
    • pp.271-278
    • /
    • 1993
  • Acoustic characteristics of silencer system are affected by various geometric parameters such as cross sectional geometry, size of chamber, and location of inlet-outlet port. It is impossible to obtain exact solutions of the equations of acoustic wave propagation except few simple cases. So, we resort to numerical techniques to analyze performance of acoustic system. In this work, finite element formulation has been obtained to predict transmission loss of an arbitrary 3-dimensional muffler in the presence of mean flow of low mach number. The effect of the degree of the ellipticity of expansion chambers on the transmission loss has been studied using the resulting finite element equation.

  • PDF