• 제목/요약/키워드: Inlet/Outlet Location

검색결과 55건 처리시간 0.029초

사각형 단순 확장소음기의 성능향상을 위한 입$\cdot$출구 위치의 최적설계 (Optimum Design for Inlet and Outlet Locations of Rectangular Expansion Chamber for Improving Acoustic Performance)

  • 김봉준;정의봉;황상문
    • 소음진동
    • /
    • 제9권4호
    • /
    • pp.738-746
    • /
    • 1999
  • The performance of muffler can be improved for a frequency range of interest by moving inlet and outlet locations. And optimal location of inlet and outlet can be determined to improve the acoustic performance. The optimum design using FEM, however, may take a very long time and be very hard to take inlet and outlet locations as design variables. In this paper, the acoustic performance of reactive type single expansion chamber muffler is predicted using higher order mode theory. The sensitivity analysis of transmission loss with respect to the location of inlet and outlet is suggested. And the acoustic power transmission coefficient for a frequency of interest is used as cost function. Optimum location of inlet and outlet is determined to minimize cost function by using SUMT algorithm.

  • PDF

원형 단순 확장소음기의 성능향상을 위한 입.출구 위치의 최적설계 (Optimum Design for Inlet and Outlet Locations of Circular Expansion Chamber for Improving Acoustic Performance)

  • 안세진;김봉준;정의봉
    • 대한기계학회논문집A
    • /
    • 제24권10호
    • /
    • pp.2487-2495
    • /
    • 2000
  • The acoustic characteristics of expansion chamber will be changed with the variation of inlet/outlet location due to the higher order acoustic mode in a high frequency in which the plane wave theory is not available. In this paper, the acoustic performance of reactive type expansion chamber with circular cross-section is analyzed by using the modified mode matching theory. The sensitivity analysis of four-pole parameters with respect to the location of inlet and outlet is also suggested to increase the acoustic performance. The acoustic power transmission coefficient is used as cost function, and the location of inlet and outlet is used as design variables. The steepest descent method and SUMT algorithm are used for optimization technique. Several results showed that the expansion chamber with optimally located inlet/outlet had better acoustic performance than concentric expansion chamber.

임의의 입ㆍ출구 위치를 가지는 소음기 해석을 위한 개선된 모드일치법 (Modified Mode Matching Technique for Analyzing Simple Expansion Chamber with Arbitrary Inlet/Outlet Location)

  • 김봉준;정의봉;이정환
    • 대한기계학회논문집A
    • /
    • 제24권5호
    • /
    • pp.1314-1322
    • /
    • 2000
  • The acoustic property of reactive type single expansion chamber can be analyzed by traditional plane wave theory. This theory can be applied in low frequency range and has good performance. But this theory can't include higher order modes, therefore another method is essential to analyze acoustic filter in high frequency range. Many researcher suggested the method that can concern higher order modes, and their methods are using mode matching technique. But there is no method that can be applied to the analysis of single expansion chamber with arbitrary inlet/outlet duct position and numbers of higher order modes of inlet/outlet duct and middle chamber. In this paper, the method which can analyze single expansion chamber with arbitrary inlet/outlet duct position and numbers of higher order modes of inlet/outlet duct and middle chamber using fundamental mode matching technique, was suggested and the predictions by this method was compared with those by the finite element method, and the influence of inlet/outlet location to acoustic performance of single expansion chamber is investigated and explained by higher order mode effects.

원형단순확장관의 입$\cdot$출구 위치와 단면 크기를 고려한 음향해석법 (Acoustic Analysis of Circular Simple Expansion Chamber with Arbitrary Location and Cross-Section Area of Inlet/Outlet)

  • 김봉준;정의봉;황상문
    • 소음진동
    • /
    • 제9권5호
    • /
    • pp.914-921
    • /
    • 1999
  • There are many theoretical investigations to analyze higher order mode of reactive type single expansion chambers with offset inlet/outlet locations. But the conventional method has the restriction that the ratio between the area of inlet(or outlet) pipe and that of chamber must be natural number. In the paper, a new method was suggested to apply the Kim's method to silencer with circular cross-section. Not only the offset location but also the magnitude of cross-section area of inlet/outlet pipe can be considered by the suggested method. The predictions by this new method also compared with those by the finite element method and Munjal's method in order to verify the accuracy of the suggested method presented here.

  • PDF

출.입구 위치에 따른 배플을 갖는 원통내 유동특성에 대한 수치해석 (Numerical Analysis of Flow Phenomena in Cylindrical Shell with Baffle according to the Position of Inlet and Outlet)

  • 신용한;사이드;전영철;정한식;정효민
    • 동력기계공학회지
    • /
    • 제15권6호
    • /
    • pp.22-26
    • /
    • 2011
  • A numerical simulation on the flow field was carried out on the cylindrical shell with baffles. The steady incompressible 3-D Navier-Stokes solution is obtained with the actual operational condition and geometry of the heat exchanger. The effect of the location of inlet and outlet on the cylindrical shell with baffle is investigated by varying flow rate. The angle between the location of In/Outlet and baffle cutting part is $0^{\circ}$, $30^{\circ}$, $60^{\circ}$, $90^{\circ}$, $120^{\circ}$, $150^{\circ}$ and $180^{\circ}$. The present results show that the pressure drop is dependent on Reynolds number in the inlet area and position of inlet and outlet; i.e., the pressure drop increases with increasing Reynolds number and the pressure drop decreases with increasing angle between baffle cutting part and position of inlet and outlet.

평행류 열교환기 내부의 열유동 해석 (Heat and Flow Analysis Inside a Parallel-Flow Heat Exchanger)

  • 오석진;정길완;이관수
    • 대한기계학회논문집B
    • /
    • 제27권6호
    • /
    • pp.781-788
    • /
    • 2003
  • In the present study, the heat and flow characteristics of a parallel-flow heat exchanger are numerically analyzed by using three-dimensional turbulent modeling. Heat transfer rate and pressure drop are evaluated using the concept of the efficiency index by varying the locations, the shapes and angles of inlet/outlet, and the protrusion height of flat tube. It is found that negative angle of the inlet improves the heat transfer rate and pressure drop. Results show that the locations of the inlet and outlet should be toward the right side and the left side to the reference model, respectively, in order to enhance the heat transfer rate and pressure drop. Increasing the height of the lower header causes pressure drop to decrease and yields the good flow characteristics. The lower protrusion height of flat tube shows the improvement of the heat transfer rate and pressure drop. The heat transfer rate is greatly affected by the parameters of outlet side such as the location and angle of the outlet. However, the pressure drop is influenced by the parameters of inlet side such as the location and angle of inlet and the height of the header.

이론적 열유동 해석을 이용한 농산물 저장 및 유통 스마트 유닛로드 컨테이너의 통기공 최적화 설계 (Ventilation Hole Optimum Design of Smart Unit Load Container for Storage and Distribution Agricultural Products by Theoretical Heat Flow Analysis)

  • 최동수;김용훈;김진세;박천완;정현모;김기석;박종민
    • 한국포장학회지
    • /
    • 제28권3호
    • /
    • pp.211-215
    • /
    • 2022
  • Air distribution occupies an important position in the smart unit load container design process for agricultural products. Inner air may be uncomfortable because of its temperature, speed, direction, and volume flow rate. It doesn't matter how efficient the ventilation equipment is if the air is not distributed well. The main aim of this study was to design the inlet and outlet fan locations of smart unit load container for agricultural products. A numerical study was performed on the effects of the location of inlet air and outlet air in relation to the container cooling sources on air distribution and thermal comfort. A concept of combining inner container cooling sources with the exhaust outlet was employed in this investigation. Also, in this research, the developed CFD (Computational Fluid Dynamics) models were thoroughly validated. This system was adopted for use in container spaces, where the exhaust outlet was located. In this study, the location of the inlet was derived through CFD for a container with a size of 1,100×1,100×1,700 mm, and it was derived that the inlet was located at the center of the lower part of the container for efficient air flow. It was efficient to position the outlet through the air inlet in the center of the lower part of the container at the top of the same side.

개구부와 열원의 위치에 따른 연기이동에 관한 연구 (A Study on the Smoke Movement by the Opening and Heat Generator Position)

  • 조성우;이재윤
    • 한국화재소방학회논문지
    • /
    • 제16권4호
    • /
    • pp.7-14
    • /
    • 2002
  • 열원의 발열이 있는 작은 공간에서 상승기류에 의한 연기 확산의 특징에 대하여 조사하였다. 유입구와 유출구의 위치와 연기의 발생위치의 변화에 대한 3가지의 경우에 대하여 수치시뮬레이션을 이용하여 연기가 어떻게 확산되는가를 알아보았다. 좌측 상부에 유입구와 우측 하부에 유출구가 설치된 경우와 좌측 하부에 유입구, 우측 상부에 유출구가 설치된 경우는 기류속도, 공기온도 및 연기농도는 비슷한 분포를 나타냈다. 또한, 좌측 하부의 유입구와 우측 상부의 유출구인 경우 온도분포는 0∼0.3이고, 연기의 농도분포는 0.06∼0.14로 나타났다. 특히, 열원의 발열의 위치는 작은 실에 있어서 온도분포에는 영향을 미치지 않으나, 농도분포에는 영향을 미치는 것을 나타났다.

식물공장 이중창호의 하절기 열전달 성능 분석 (Performance Analysis of Summertime Heat Transfer Characteristics of the Double Skin Window for Plant Factory)

  • 소재현;김우태
    • 설비공학논문집
    • /
    • 제24권4호
    • /
    • pp.351-357
    • /
    • 2012
  • To reduce the summertime cooling load of a plant factory, a concept design was performed for the double skin window which utilizes the low temperature air from a ground coupled heat exchanger. The design parameters were selected as the number of cavity air inlet, the cavity thickness, the location of cavity air inlet, and the configuration of cavity air outlet. A parametric study was conducted in a systematic way to evaluate the heat transfer characteristics of the double skin window. As the number of cavity air inlet and the cavity thickness increase, the heat flux from outside air to indoor air was decreased. The effect of the location of cavity air inlet was not significant and the larger cavity air outlet area gave us relatively better heat blocking performance from outside hot air. This study demonstrated that it is possible to develop an improved double skin window by utilizing a ground coupled heat exchanger.

환기상태 분석에 따른 급 배기구 위치 평가 (Evaluation of the location of the Outlets according to the Analysis of Ventilation conditions)

  • 문용준;김혁순;곽명근;오명도
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1207-1212
    • /
    • 2008
  • The purpose of this study is to evaluate the location of the outlets in the mechanical ventilation system installed in apartment. We performed the numerical analysis to estimate the ventilation effectiveness and the indoor $CO_2$ concentration considering the occupants and the condition with inlet and outlet in each room. From the numerical results, modified location of the outlets is about 10% high than designed one with respect to the ventilation effectiveness when the occupants are not considered. But designed location of inlet and outlet in living room and kitchen is better than modified one with respect to the reduction of $CO_2$ concentration in the living room and kitchen with occupants. In case of our model, Air change per hour (0.7) is not enough to sustain the acceptable criteria of $CO_2$ concentration (1000ppm) in the room with the occupants

  • PDF