• Title/Summary/Keyword: Inlay

Search Result 193, Processing Time 0.027 seconds

Acquisition and Processing of 3D Data (3차원 데이터의 획득 및 가공)

  • Kim A.H.;Kim Y.S.;Bae C.;Kang W.C.;Kim Y.D.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.286-290
    • /
    • 2003
  • Accurate acquisition of surface geometries such as machined surfaces, biological surfaces, and deformed parts have been very important technique in scientific study and engineering, expecially for system design, manufacturing and inspection. Two camera method keeps accuracy more than double than mechanical method. In this paper, we describe the processes surface data of teeth for automatic processing, transformation that changes to coping data of possible numeric data form and processed inlay teeth. As the result of the Inlay manufacture, which can process with high resolution, therefore we construct the automatic processing system that depends on manual

  • PDF

A STUDY ON THE STATE OF TREATMENT IN PEDODONTICS (소아치과(小兒齒科) 치료현황(治療現況)에 관(關)한 연구(硏究))

  • Cha, Moon-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.7 no.1
    • /
    • pp.7-11
    • /
    • 1980
  • 6877 children who visited to pedodontic department from 1976 to 1979, were surveyed on the state of dental caries, therapic inclination a year and yearly tendency of treatment. The results were as follows ; 1. The prevalence of dental caries tended to show the increase in general year by year. 2. Girls had higher d.e.f. T. & S. index and D.M.F. T. & S. index than boys generally. 3. Distribution of therapy a year. (1979) Amalgam Filling 4464 Pulpotomy 952 S.P.-Crown 1538 Gold Inlay 250 Space Maintainer 341 Extraction 1313 Orthodontic Appliance 206 4. Tendency of treatment in 1979 (compared with 1976) No. of new patients 87.5% increased Amalgam Filling 50.0% increased Extraction 31.4% increased Orthodontic Appliance 267.9% increased S.P.-Crown 225.8% increased Gold Inlay 27.8% decreased Space Maintainer 2.3% decreased Pulpotomy 20.5% decreased.

  • PDF

3D Processing System of Tooth shape (치형 3차원 가공시스템)

  • Kim, Young-Su;Kim, Nam-Oh;Min, Wan-Ki;Shin, Suck-Doo;Kang, Won-Can;Kim, Young-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.120-123
    • /
    • 2003
  • Accurate acquisition of surface geometries such as machined surfaces, biological surfaces, and deformed parts have been very important technique in scientific study and engineering, expecially for system design, manufacturing and inspection. Two camera method keeps accuracy more than double than mechanical method. In this paper, we describe the processes surface data of teeth for automatic processing, transformation that changes to coping data of possible numeric data form, and processed inlay teeth. As the result of the Inlay manufacture, which can process with high resolution, therefore we construct the automatic processing system that depends on manual.

  • PDF

An Efficient Modeling of Inlay/Onlay Prostheses using Computer Graphics Deformation Techniques (컴퓨터 그래픽스 변형 기법을 이용한 인레이/온레이 보철물의 효율적인 모델링)

  • Yoo, Kwan-Hee
    • Journal of the Korea Computer Graphics Society
    • /
    • v.11 no.2
    • /
    • pp.1-8
    • /
    • 2005
  • 하나의 치아가 일부 파손되어 수복되어야 할 보철물을 인레이/온레이(Inlay/Onlay)라 한다. 본 논문에서는 3차원 메쉬 기반 모델에서 보다 정확한 인레이/온레이를 효과적으로 모델링하기 위한 기법을 제안한다. 인레이/온레이는 지대치와 접하는 내면과 밖으로 들어나는 외면으로 구성된다. 인레이/온레이의 내면 모델링은 2차원 다각선상의 Minkowski Sum 알고리즘을 이용하여 지대치와의 접합력을 확보한다. 그리고 미리 데이터베이스에 저장된 표준 치아 모델, 치과의사에 의해 만들어진 FGP(functionally guided plane) 및 메쉬의 변형 기법인 DMFFD(direct manipulation free-form deformation) 기법[16]과 MWD(multiple wires deformation) 기법[24]을 이용하여 외면을 모델링한다. 데이터베이스에 저장된 표준 치아는 인레이/온레이 외면의 형태를 결정하기 위해 사용되며, FGP는 환자의 인접면과 교합면의 특성을 반영하기 위해 사용되었다. 마지막으로 3차원 메쉬의 두 변형 기법인 DMFFD와 MWD 기법은 환자의 인접면과 교합면을 반영한 치아의 형태를 만들어 내기 위해 사용된다. 본 논문에서 제안한 방법은 인레이/온레이의 내면과 외면을 설계할 때 필요한 정보를 미리 설정하여 처리하므로 기존의 방법에 비해 짧은 시간에 보다 정확한 인레이/온레이를 설계할 수 있었다.

  • PDF

EXPERIMENTAL STUDY ON THE RETENTION FORCE OF INLAY CAVITY (와동의 깊이 및 넓이의 변화가 Inlay 유지력에 미치는 영향에 관한 실험적 연구)

  • Hahn, Taik-Seon;Choi, Zai-Kyung
    • The Journal of the Korean dental association
    • /
    • v.9 no.7
    • /
    • pp.431-437
    • /
    • 1971
  • The authors performed an experimental study on the retention force in cavities with various depth and width. We used the simple model cavities which were cylindrically formed to eliminate the unexpected influence during experiment, and obtained following results. 1. The retention force in the cavities with parallel wall was vigorous even in the small cavity and increased considerably followed by extending the cavity size. 2. The ratention force resulted more vigorously by that the depth became deeper than that the distance between the lateral walls became longer. 3. Compared with the retention force in the cavities which had the same frictional lateral surface, it was more vigorous in the deeper cavity than in the cavity which was longer distance between the lateral surfaces.

  • PDF

A Study on Qualities and Components of Wax Patterns (납형의 성질(性質) 및 성분(成分)에 관(關)한 연구(硏究))

  • Kim, Myeong-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.2 no.1
    • /
    • pp.17-19
    • /
    • 1980
  • This study was aimed at obtaining a desirable wax pattern for inlay. The method used was to analyze, mix, and heat several kinds of waxes, comparing the temperatures of their components. The result was Type C wax. In type C the amount of paraffin was generally contained(60$\sim$70%) was reduced to 45% and there was mixed 10%-15% of carnauba, which was intended for the wax not to soften readily at low temperatures. The type C has some advantages for general use: handy preparation, high safety, and economy. The inlay waxes commonly used contracted if the temperature fell from 38 to 28, but the contraction of type C was observed to be 0.2%$\sim$0.4% in proportion to the 10 fall. This was more characteristic in mixing.

  • PDF

Jangdo(Small Ornamental Knives) manufacturing process and restoration research using Odong Inlay application (오동상감(烏銅象嵌)기법을 활용한 장도(粧刀)의 제작기술 및 복원연구)

  • Yun, Yong Hyun;Cho, Nam Chul;Jeong, Yeong Sang;Jang, Chu Nam
    • Korean Journal of Heritage: History & Science
    • /
    • v.49 no.2
    • /
    • pp.172-189
    • /
    • 2016
  • In this research, literature research on the Odong material, mixture ratio, casting method and casting facility was conducted on contemporary documents, such as Cheongong Geamul. Also, a long sword was produced using the Odong inlay technique. The sword reproduction steps were as follows; Odong alloying, silver soldering alloying, Odong plate and Silver plate production, hilt and sheath production, metal frame and decorative elements, such as a Dugup (metal frame), production, Odong inlay assembly and final assembly. For the Odong alloy production, the mixture ratio of the true Odong, which has copper and gold ratio of 20:1, was used. This is traditional ratio for high quality product according to $17^{th}$ century metallurgy instruction manual. The silver soldering alloy was produced with silver and brass(Cu 7 : Zn 3) ratio of 5:1 for inlay purpose and 5:2 ratio for simple welding purpose. The true Odong alloy laminated with silver plate was used to produce hilt and sheath. The alloy went through annealing and forging steps to make it into 0.6 mm thick plate and its backing layer, which is a silver plate, had the matching thickness. After the two plates were adhered, the laminated plate went through annealing, forging, engraving, silver inlaying, shaping, silver welding, finishing and polishing steps. During the Odong colouring process, its red surface turns black by induced corrosion and different hues can be achieved depending on its quality. To accomplish the silver inlay Odong techniques, a Hanji saturated with thirty day old urine is wrapped around a hilt and sheath material, then it is left at warm room temperature for two to three hours. The Odong's surface will turn black when silver inlay remains unchanged. Various scientific analysis were conducted to study composition of recreated Odong panel, silver soldering, silver plate and the colouring agent on Odong's surface. The recreated Odong had average out at Cu 95.57 wt% Au 4.16wt% and Cu 98.04 wt% Au 1.95wt%, when documented ratio in the old record is Cu 95wt% and Au 5wt%. The recreated Odong was prone to surface breakage during manufacturing process unlike material made with composition ratio written in the old record. On the silver plate of the silver and Odong laminate, 100wt% Ag was detected and between the two layers Cu, Ag and Au were detected. This proves that the adhesion between the two layers was successfully achieved. The silver soldering had varied composition of Ag depending on the location. This shows uneven composition of the silver welding. A large quantities of S, that was not initially present, was detected on the surface of the black Odong. This indicates that presence of S has influence on Odong colour. Additional study on the chromaticity, additional chemical compounds and its restoration are needed for the further understanding of the origin of Odong colour. The result of Odong alloy testing and recreation, Odong silver inlay long sword production, scientific analysis of the Odong black colouring agent will form an important foundation of knowledge for conservation of Odong artifact.

Inlay graft of acellular dermal matrix to prevent incisional dehiscence after radiotherapy in prosthetic breast reconstruction

  • Kim, Mi Jung;Ahn, Sung Jae;Fan, Kenneth L.;Song, Seung Yong;Lew, Dae Hyun;Lee, Dong Won
    • Archives of Plastic Surgery
    • /
    • v.46 no.6
    • /
    • pp.544-549
    • /
    • 2019
  • Background As the indications for postmastectomy radiotherapy expand, innovative solutions are required to reduce operative complications and reconstructive failure after prosthetic breast reconstruction. In this study, we investigated the effectiveness of acellular dermal matrix (ADM) inlay grafts in preventing postoperative wound dehiscence of irradiated breasts in the context of prosthetic breast reconstruction. Methods A retrospective analysis was conducted of 45 patients who received two-stage prosthetic reconstruction and radiotherapy following mastectomy. An ADM graft was placed beneath the incisional site during the second-stage operation in 19 patients using marionette sutures, whereas the control group did not receive the ADM reinforcement. Patient demographics and complications such as wound dehiscence, capsular contracture, peri-prosthetic infection, cellulitis, and seroma were compared between the two groups. Results During an average follow-up period of 37.1 months, wound dehiscence occurred significantly less often in the ADM-reinforced closure group (0%) than in the non-ADM group (23.1%) (P=0.032). There was no significant difference between the two groups in relation to other complications, such as capsular contracture, postoperative infection, or seroma. Conclusions The ADM inlay graft is a simple and easily reproducible technique for preventing incisional dehiscence in the setting of radiotherapy after prosthetic breast reconstruction. The ADM graft serves as a buttress to offload tension during healing and provides a mechanical barrier against pathogens. Application of this technique may serve to reduce complications in prosthetic breast reconstruction after radiotherapy.

A COMPARATIVE STUDY ON THE MECHANICAL PROPERTIES OF CEROMER, CERAMIC AND INDIRECT COMPOSITE RESIN (세로머, 세라믹 및 복합레진의 기계적 성질의 비교에 관한 연구)

  • Baek, Jeong-Hwa;Park, Yil-Yoon;Hwang, Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.1
    • /
    • pp.233-239
    • /
    • 1999
  • Recently, a second generation composite resin system(ceromer) was introduced with significantly improved mechanical properties. The purpose of this study was to compare a ceromer with the other restorative materials and to assess its clinical usefulness. In this study, we used four restorative materials : amalgam (BESTALOY$^{(R)}$), indirect composite resin (Clearfil CR Inlay$^{(R)}$), ceromer (Targis$^{(R)}$) and ceramic (Vintage$^{(R)}$). And then we devided into four groups. The materials of each group were as follows : Amalgam group : BESTALOY$^{(R)}$ (Dong Myung Dental Industrial Co.) Composite Resin group : Clearfil CR Inlay$^{(R)}$ (Kuraray) Ceromer group : Targis$^{(R)}$ Dentin (Ivoclar-Vivadent) Ceramic group : Vintage$^{(R)}$ (Shofu Inc.) According to the above classification, we made samples through the polymerization of BESTALOY$^{(R)}$, Clearfil CR Inlay$^{(R)}$ and Targis$^{(R)}$ with separable cylindrical metal mold and firing of Vintage$^{(R)}$ in a investment mold. And then, we measured and compared the value of compressive strength, diametral tensile strength and Vicker's microhardness of each sample. The results were as follows : 1. Amalgam showed the highest value of compressive strength (390.37${\pm}$42.22MPa) and the value of ceromer was somewhere between ceramic and indirect composite resin. There were significant differences among the experimental groups(p<0.001). 2. Indirect composite resin showed the highest value of diametral tensile strength (74.21${\pm}$15.33MPa) and there was no significant difference with ceromer. Ceromer was higher diametral tensile strength than amalgam and ceramic (p<0.001). 3. Ceramic showed the highest value of microhardness (538.44${\pm}$37.38Hv) and the value of ceromer was somewhere between ceramic and indirect composite resin. There were significant differences among the experimental groups (p<0.001).

  • PDF