• 제목/요약/키워드: Inlay

검색결과 193건 처리시간 0.021초

일측성 구순열비변형에서 다공성 폴리에틸렌 판을 이용한 상악골이상구증대술 (Augmentation of Pyriform Margin Using Porous High-Density Polyethylene Sheet In Unilateral Cleft Lip Nasal Deformity)

  • 한기환;김진한;최태현;김준형;손대구
    • Archives of Plastic Surgery
    • /
    • 제35권4호
    • /
    • pp.431-438
    • /
    • 2008
  • Purpose: The common deformity after the correction of unilateral cleft lip nasal deformity is nasal asymmetry, and it is caused by the hypoplasia of the pyriform aperture. To correct this, many procedures have been applied, but still many problems are present. Authors performed the inlay and onlay insertion of porous high density polyethylene sheet(1 mm thickness $Medpor{(R)}$ sheet) in the hypoplastic pyriform margin of cleft side and obtained satisfactory results. Methods: 11 cases were performed and the mean follow up period was 15.1 months. Their mean age was 23.6 years. Under general anesthesia, bilateral pyriform margin was exposed. $Medpor{(R)}$ sheets in "match stick" like shaped were inlay inserted, and kidney shaped were onlay inserted fixating with two 6 mm titanium screws. After the surgery, the results was evaluated by photogrammetric analysis. On the basal view, the distance from the subalare and labiale superius' to the transverse baseline connecting the both cheilions was measured from the cleft side and the non-cleft side. Then, the postoperative symmetry was assessed by obtaining the cleft side against the non-cleft side as proportion index, defined as lateral and medial upper lip contour index. Results: There were 2 infections. The cause was because the inserted implant was too long and thus protruded to the base of nasal cavity. The lateral upper lip contour index was from 95.49 to 103.27, and medial upper lip contour index was from 90.92 to 100.49, it was statistically increased, and thus the symmetry was improved. However clinically mild depression remained at nostril floor. Conclusion: Authors performed porous high density polyethylene sheet inlay and onlay insertion for the hypoplasia of the pyriform margin in unilateral cleft lip nasal deformity. It was found that depressed pyriform margin and upper lip were corrected effectively except for the nostril floor, for which an additional soft tissue augmentation would be necessary. The inlay insertion has risk of protrusion, thus the guideline of the use of artificial prosthesis should be observed strictly.

도재인레이 하방에서 광중합형 복합레진과 이중중합형 복합레진시멘트의 미세경도와 중합률에 관한 연구 (THE MICROHARDNESS AND THE DEGREE OF CONVERSION OF LIGHT CURED COMPOSITE RESIN AND DUAL CURED RESIN CEMENTS UNDER PORCELAIN INLAY)

  • 김승수;조성식;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제25권1호
    • /
    • pp.17-40
    • /
    • 2000
  • Resin cements are used for cementing indirect esthetic restorations such as resin or porcelain inlays. Because of its limitations in curing of purely light cured resin cements due to attenuation of the curing light by intervening materials, dual cured resin cements are recommended for cementing restorations. The physical properties of resin cements are greatly influenced by the extent to which a resin cures and the degree of cure is an important factor in the success of the inlay. The purpose of this study was to evaluate the influence of porcelain thickness and exposure time on the polymerization of resin cements by measuring the microhardness and the degree of conversion, to investigate the nature of the correlation between two methods mentioned above, and to determine the exposure time needed to harden resin cements through various thickness of porcelain. The degree of resin cure was evaluated by the measurements of microhardness [Vickers Hardness Number(VHN)] and degree of conversion(DC), as determined by Fourier Transform Infrared Spectroscopy(FTIR) on one light cured composite resin [Z-100(Z)] and three dual cured resin cements [Duo cement(D), 3M Resin cement(R), and Dual cement(DA)] which were cured under porcelain discs thickness of 0mm, 1mm, 2mm, 3mm with light exposure time of 40sec, 80sec, 120sec, and regression analysis was performed to determine the correlation between VHN and DC. In addition, to determine the exposure time needed to harden resin cements under various thickness of porcelain discs, the changes of the intensity of light attenuated by 1mm, 2mm, and 3mm thickness of porcelain discs were measured using the curing radiometer. The results were obtained as follows ; 1. The values of microhardness and the degree of conversion of resin cements without intervening porcelain discs were 31~109VHN and 51~63%, respectively. In the microhardness Z was the highest, followed by R, D, DA. In the degree of conversion, D and DA was significantly greater than Z and R(p<0.05). 2. The microhardness and the degree of conversion of the resin cements decreased with increasing thickness of porcelain discs, and increased with increasing exposure time, D and R showed great variation with inlay thickness and exposure time, whereas, DA showed a little variation. 3. The intensity of light through 1mm, 2mm, and 3mm porcelain inlays decreased by 0.43, 0.25, and 0.14 times compared to direct illumination, and the respective needed exposure times are 53 sec, 70 sec, and 93 sec. In D and R, 40 sec of light irradiation through 2mm porcelain disc and 80 sec of light irradiation through 3mm porcelain disc were not enough to complete curing. 4. The microhardness and the degree of conversion of the resin cements showed a positive correlationship(R=0.791~0.965) in the order of R, D, Z, DA. As the thickness of porcelain discs increased, the decreasing pattern of microhardness was different from that of the degree of conversion, however.

  • PDF

복합레진으로 제작한 인레이 보철물 구조에 따른 교합면 부위의 2차원 변연 적합도 및 내면 부위의 3차원 정확성 분석 (Analysis of the 2-dimensional marginal fit of the occlusal surface and the 3-dimensional accuracy of the inner surface of the occlusal surface according to the inlay prosthesis structure made of composite resin)

  • 김동연;이태희;박동인;박진영;정일도;이하나;김지환;김웅철
    • 대한치과기공학회지
    • /
    • 제41권1호
    • /
    • pp.21-27
    • /
    • 2019
  • Purpose: To evaluate 2D and 3D of occulsal, mesial-occlusal and mesial-occlusal-distal cavity of composite resin inlay. Methods: Abutment tooth 16, 36 of FDI system was selected for the study. Inlay prostheses classified as occlusal cavity (OC group), mesial-occlusal (MOC) and mesial-occlusal-distal cavity (MODC) were prepared using composite resin. Composite resin was injected with composite resin in prepared tooth cavity and then photopolymerized with UV light. Additional thermal polymerization was performed. Marginal gap of composite resin inlays were measured by digital microscope(x160) with silicone replica technique. The data was analyzed from statistical software for Kruskal-Wallis test (${\alpha}=0.05$). 3-dimensional analysis was analyzed through superimposition method. Results: The smallest 2D marginal fit measure of the three groups was $47.0{\pm}21.6{\mu}m$ in the MOC group. The largest 2D marginal was $69.1{\pm}33.8{\mu}m$ in the MODC group. In the trueness of the three groups, the most accurate figure was $14.4{\pm}2.3{\mu}m$ for the MODC group. In Precision, the most accurate figure was $14.5{\pm}4.3{\mu}m$ for the MODC group. Conclusion : In this study, 2D marginal fit of OC, MOC, and MODC cavities fabricated with composite resin was applicable to all clinical applications. In the 3D inner surface accuracy evaluation, the MODC group showed the accuracy results.

Resin inlay with molar uprighting

  • Shin, Dong-Ho;Hong, Seong-Tae;Son, Ho-Hyun
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2007년도 Autumn Scientific Meeting(the 128th) of Korean Academy of Comservative Dentistry
    • /
    • pp.629-629
    • /
    • 2007
  • PDF

치아회분과 석고를 혼합하여 제작한 block의 inlay 매식후 치유과정에 관한 실험적 연구 (THE EXPERIMENTAL STUDY ON THE HEALING PROCESS AFTER THE INLAY IMPLANTATION OF TOOTHASH-PLASTER MIXTURE BLOCK)

  • 김영균;여환호;박인순;조재오
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제18권2호
    • /
    • pp.253-260
    • /
    • 1996
  • The purpose of this investigation was to determine the possibility of clinical use of toothash-plaster block implant material with ratio of 2 : 1 by weight. We made 1cm diameter round partial thickness defect at both sides of calvaria. Right side was implanted with block and left side was not implanted as a control site. The following results were obtained : 1. In gross examinations, the implanted site had a hardness on palpation and the margin with host bone was not identified clearly at 12 weeks after operation. But control site contained the fibrous tissue. 2. In the light microscopic examinations, most of the implanted sites were repaired by newly-formed bone at 12 weeks postoperatively. 3. At 8 weeks postoperatively, the implanted particles were divided into small granules and the amount was decreased gradually. Some remained particles were united directly with newly-formed bone. But the implanted particles still remained partly at 24 weeks postoperatively.

  • PDF

Correlation between clinical clerkship achievement and objective structured clinical examination (OSCE) scores of graduating dental students on conservative dentistry

  • Bang, Jae-Beum;Choi, Kyoung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • 제38권2호
    • /
    • pp.79-84
    • /
    • 2013
  • Objectives: This study aimed to investigate the effect of clinical clerkship-associated achievements, such as performance of procedures at the student clinic, observation, and attitude towards a clerkship, on the objective structured clinical examination (OSCE) scores of dental students graduating in restorative dentistry. Materials and Methods: The OSCEs consisted of two stations designed to assess students' clinical skills regarding cavity preparation for a class II gold inlay and a class IV composite restoration. The clerkship achievements, consisting of the number of student clinical procedures performed, observation-related OSCE, and scores of their attitudes towards a conservative dentistry clerkship, were assessed. Correlation and multiple regression analyses were conducted. Results: The correlation coefficient between the OSCE scores for cavity preparation for a class II gold restoration and clerkship attitude scores was 0.241 (p < 0.05). Regarding a class IV composite restoration, OSCE scores showed statistically significant correlations with the observation (r = 0.344, p < 0.01) and attitude (r = 0.303, p < 0.01) scores. In a multiple regression analysis, attitudes towards a clerkship (p = 0.033) was associated with the cavity preparation for a class II gold inlay OSCE scores, while the number of procedure observations (p = 0.002) was associated with the class IV composite restoration OSCE scores. Conclusions: The number of clinical procedures performed by students, which is an important requirement for graduation, showed no correlation with either of the OSCEs scores.

고속 UHF RFID 태그 검사 장비를 위한 전용 리더 (A Specialized Reader for High Speed UHF RFID Tag Inlay Inspection Equipment)

  • 배성우;박준석;성영락;오하령
    • 전기학회논문지
    • /
    • 제63권1호
    • /
    • pp.63-69
    • /
    • 2014
  • RFIDs have not become widespread as expected partly due to the cost, size, read range, and reliability problems of tags. The success rate of reading must be improved in order for RFIDs to be widely adopted. Quality control of tags is crucial to meet this requirement. In this study, we designed and implemented a high-performance reader used in inspection equipment that conducts prior inspection of tags. To improve performance of the developed reader, the baseband modem and command processor (CP) were designed using H/W logic and implemented with FPGA. The inspection of small pitch inlays was made possible through the antenna shielding device and H/W command processor function. This equipment enables accurate evaluation of performance and identification of tags satisfying a given read range. By contributing to sort out defective tags, the results can ultimately lead to more stable RFID services.