• 제목/요약/키워드: Injection pipe

검색결과 161건 처리시간 0.024초

Thermo-fluid engineering in deep geothermal energy

  • 김영원
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.84.1-84.1
    • /
    • 2015
  • Recent years in particular in Korea see intensive interests in a deep geothermal engineering and its application in different uses as far as from direct uses to power generation sectors, that are achieved by harnessing hot energy sources from the earth. For instance widespread interest has been generated because the geothermal energy is the source that one extracts it for more than 20 hours per day and for about 30 years of an operation of the plant, which enables to give base load as for heating as well as an electric generation. In retrospect, shallow geothermal energy using heat pumps is commonplace in Korea while the deep geothermal is in the early stage of the development. Geothermal energies in view of the way of extracting heat are mainly categorized into several types such as a single well system, a hydrothermal system, an enhanced geothermal system (EGS) etc. In this talk, this speaker focuses on the thermo-fluid engineering of the single well system by introducing the modeling in order to harness hot fluid that is thermally balanced with the fluid of an injection well, which provides a challenge to assess the life time of the well. To avoid the loss of the temperature in producing the hot fluid, a specialized pipe or a borehole heat exchanger has been designed, and its concept is introduced. On the other hand, a binary system or an organic Rankine cycle, which provides the methodology to convert the heat into an electricity, is briefly introduced. Some experimental results of the binary system which has been constructed in our lab will be presented. Lastly as for the future direction, some comments for the industrialization of the deep geothermal energy in this country will be discussed.

  • PDF

디젤 배기관에 분사된 우레아 수용액의 분무 거동 및 유동 특성에 관한 연구 (Numerical Investigation of the Spray Behavior and Flow Characteristics of Urea-Water Solution Injected into Diesel Exhaust Pipe)

  • 안태현;김만영
    • 대한기계학회논문집B
    • /
    • 제38권1호
    • /
    • pp.41-48
    • /
    • 2014
  • Urea-SCR 시스템은 주로 열해리와 증발시간의 부족으로 인해 발생하는 암모니아 슬립 현상과 관련된 몇 가지 문제점들을 가지고 있으며, 이러한 문제점들은 분사된 요소수용액의 불균일한 분포를 초래한다. 따라서 본 연구에서는, 배기가스와 요소수용액 사이의 증발 및 혼합특성을 강화시키기 위해 인젝터 장착 각도 그리고 믹서의 장착 및 설치 각도와 같은 다양한 매개변수들을 바꾸며 전산해석 연구를 수행하였다. 그 결과, 이와 같은 매개변수들이 배기가스와 요소수용액의 증발 및 혼합특성에 상당한 영향을 미친다는 것을 알 수 있었으며, 이 매개변수들의 최적화가 요구된다. 또한, 본 논문은 Urea-SCR 분사 시스템의 DeNOx 성능을 증가시키고 암모니아 슬립을 감소시키기 위한 최적 설계 시 유용한 기준을 제안할 것이다.

정적연소기를 이용한 합성가스의 가연한계 및 연소특성에 관한 실험적 연구 (An Experimental Study on Flammability Limits and Combustion Characteristics of Synthetic Gas in a Constant Combustion Chamber)

  • 조용석;이성욱;원상연;박영준;김득상
    • 한국자동차공학회논문집
    • /
    • 제16권1호
    • /
    • pp.14-21
    • /
    • 2008
  • Synthetic gas is defined as reformed gas from hydrocarbon-based fuel and the major chemical species of the synthetic gas are $H_2$, CO and $N_2$. Among them, hydrogen from synthetic gas is very useful species in chemical process such as combustion. It is a main reason that many studies have been performed to develop an effective reforming device. Furthermore, other technologies have been studied for synthetic gas application, such as the ESGI(Exhaust Synthetic Gas Injection) technology. ESGI injects and burns synthetic gas in the exhaust pipe so that heat from hydrogen combustion helps fast warmup of the close-coupled catalyst and reduction of harmful emissions. However, it is very hard to understand combustion characteristic of hydrogen under low oxygen environment and complicated variation in chemical species in exhaust gas. This study focuses on the characteristics of hydrogen combustion under ESGI operating conditions using a CVC(Constant Volume Chamber). Measurements of pressure variation and flame speed have been performed for various oxygen and hydrogen concentrations. Results have been analyzed to understand ignition and combustion characteristics of hydrogen under lower oxygen conditions. The CVC experiments showed that under lower oxygen concentration, amount of active chemicals in the combustion chamber was a crucial factor to influence hydrogen combustion as well as hydrogen/oxygen ratio. It is also found that increase in volume fraction of oxygen is effective for the fast and stable burning of hydrogen by virtue of increase in flame speed.

풍화암 사면에서의 압력분사 그라우팅 네일 보강 효과 연구 (Evaluation of Reinforcing Effects of Pressure-Injected Grouting Nail in Weathered Rock)

  • 황영철;김낙영
    • 한국지반환경공학회 논문집
    • /
    • 제3권1호
    • /
    • pp.47-55
    • /
    • 2002
  • 압력분사 그라우팅 네일을 이용한 사면보강공법은 천공 후 그라우트재에 압력을 가하여 그라우트재의 천공홀 충전뿐만 아니라 지반으로의 침투주입 효과를 일으켜, 전체적인 보강력 증대를 기대하는 공법이다. 이런 특성을 설계에 반영하기 위해서는 구조재료 자체에 의한 지반보강효과 뿐만 아니라 압력분사 그라우팅에 따른 지반강도의 증진효과를 정량적으로 평가하는 것이 선행되어야 하나 아직까지는 이에 대한 연구가 부족한 실정이다. 따라서 절리가 발달한 풍화암 사면을 대상으로 시험시공 및 계측을 실시하고, 얻어진 계측값을 평가하여 절리가 발달한 풍화암 사면에서의 보강특성을 확인하였다. 또한 계측값으로부터 얻은 보강특성을 설계에 적용하기 위한 역해석 기법을 제안하였으며, 제안된 역해석 기법을 통하여 암반사면에서의 압력분사 그라우팅 네일 공법의 효용성을 확인하였다.

  • PDF

초어 및 백련의 인공 번식에 관한 연구 (AN EXPERIMENT TO INDUCE SPAWNING OF CHINESE CARPS BY PITUITARY INJECTION)

  • 김인배
    • 한국수산과학회지
    • /
    • 제3권1호
    • /
    • pp.19-26
    • /
    • 1970
  • 1969년 여름 부산수산대학 양어장에서 1963년 일본으로부터 도입하여 길러온 초어와 백련을 사용 채란과 부화실험을 하였는 바, 그 결과는 좋지 못하였지만, 다음과 같은 점을 지적한다. 1. 부산지방의 못에서 양식한 초어가 백련의 성숙 채란 적기는 6월 말부터 8원 초까지의 사이에 있다고 인정된다. 2. 산란 촉진용 뇌하수체는 동종 또는 근연종의 친어로부터 그들의 산란기이 진에 적출 보관하였다가 사용하는 것이 좋다고 인정된다. 3. 백련은 체장 40cm(전장 48cm) 가량의 작은 개체도 6년생은 모두 채란 가능하였으며, 포란수는 체장 $40\~44.5cm$ 되는 것에서 $23\~26$ 만개로 추산되었다. 4. 부화 시설로서는 원추형 망부화기를 급수 파이프에 병렬하고, 각 부화기에는 수량 조절용 발브를 달아서 수중에 설치하는 것이 좋은 동작을 하였다. 5. 알의 발생 중, 분할된 할구(세포)가 배체 밖으로 방출되는 것이 생기면, 그 알은 예외없이 괴사하였다. 6. 친어의 사전 관리를 보다 철저히 하는 것이 긴요함을 느꼈으며, 좋은 먹이와 적절한 수심 및 수온을 유지시키도록 해야 할 것이다.

  • PDF

기초침하에 의해 손상된 송전철탑 구조물의 구조성능개선 (Structural Restoration for the Electric Power Transmission Tower Damaged by Foundation Settlements)

  • 이호범;박종권;김일수;장일영;송재호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권2호
    • /
    • pp.83-93
    • /
    • 2013
  • 일반적으로 송전철탑 부재들의 보강은 적절한 그라우팅재를 활용한 인젝션과 구조 보강재 부착을 이용한 단면 확장에 따른 강성보강 방식을 주로 사용한다. 이와 같은 그라우팅 인젝션 및 단면보완은 주로 축력능력을 확장시키는 데에 의미를 갖는다. 그렇지만 보다 안정적 상태를 유지케 할 수 있는 보강방안이 적극 요구되는데 그 방법은 좌굴에 의해 손상을 받은 부재를 원상태의 길이로 환원시키고, 또한 내부적 보강효과를 동시에 갖는 새로운 부재로 교체하는 것이다. 본 연구에서는 기초침하로 구조적 손상을 받은 송전철탑의 손상회복을 위한 실증적 과정으로 우선 현장에서의 손상도 확인점검과 손상상태 및 회복상태에 대한 수치 해석적 결과를 도출하였고, 새롭게 고안한 잭킹시스템을 이용하여 보강된 부재를 교체하는 과업을 수행하였다. 이 결과는 송전철탑 유지관리의 차원상승 효과를 갖게 한다.

SOEC에 과열기의 고온 스팀을 공급하는 Interface의 열전달에 관한 전산해석 (A CFD Analysis on Heat Transfer of High Temperature Steam through Interface with Superheater and SOEC for Hydrogen Production)

  • 변현승;한단비;박성룡;조종표;백영순
    • 한국수소및신에너지학회논문집
    • /
    • 제31권2호
    • /
    • pp.169-176
    • /
    • 2020
  • There is a growing interest in hydrogen energy utilization since an alternative energy development has been demanded due to the depletion of fossil fuels. Hydrogen is produced by the reforming reaction of natural gas and biogas, and the electrolysis of water. An solid oxide electrolyte cell (SOEC) is reversible system that generates hydrogen by electrolyzing the superheated steam or producing the electricity from a fuel cell by hydrogen. If the water can be converted into steam by waste heat from other processes it is more efficient for high-temperature electrolysis to convert steam directly. The reasons are based upon the more favorable thermodynamic and electrochemical kinetic conditions for the reaction. In the present study, steam at over 180℃ and 3.4 bars generated from a boiler were converted into superheated steam at over 700℃ and 3 bars using a cylindrical steam superheater as well as the waste heat of the exhaust gas at 900℃ from a solid refuse fuel combustor. Superheated steam at over 700℃ was then supplied to a high-temperature SOEC to increase the hydrogen production efficiency of water electrolysis. Computational fluid dynamics (CFD) analysis was conducted on the effects of the number of 90° elbow connector for piping, insulation types and insulation layers of pipe on the exit temperature using a commercial Fluent simulator. For two pre-heater injection method of steam inlet and ceramic wool insulation of 100 mm thickness, the highest inlet temperature of SOEC was 744℃ at 5.9 bar.

Behavior Analysis of Discharged DIC Concentrated Seawater through Towed Pipe Injection from Ship

  • Kwon, Seong-Min;Kim, Kang-Min;Song, Hyeon-Woo;Lee, Joong-Woo
    • 한국항해항만학회지
    • /
    • 제43권2호
    • /
    • pp.79-85
    • /
    • 2019
  • Climate change is a very vital issue that can be no longer avoided. Korea has been a top-level country Iin dealing with carbon dioxide emissions since 1960. Many studies have been conducted to suppress or eliminate carbon dioxide emissions, which account for a large portion of greenhouse gases. Carbon Capture and Storage (CCS), the most practical method of them, plays a significant role. However, these methods have the disadvantage of the limits of geographical distribution and high possibility of re-emission into the atmosphere. Recently, ocean storage has been studied using Accelerated Weathering of Limestone (AWL), a technique for storing carbon dioxide in the ocean as an alternative to CCS, an underground storage. AWL is a method of converting carbon dioxide into concentrated water in the form of bicarbonate ion and discharging it to the ocean to dilute and store it. It does not cause re-emission to the atmosphere, and the discharged concentrated water increases the alkalinity of the ocean to prevent marine acidification. The objective of this study was to understand the behavior of DIC (Dissolved Inorganic Carbon) including carbon dioxide during the ocean discharge of bicarbonate ion concentrated water in AWL method. This study area was set near Ulleung-do where sufficient water depth and operational efficiency were secured. CORMIX model was used to calculate the material diffusion by submerged discharge using ship.

균일류에서 프로펠러 앞날 근처 관통구가 모형 프로펠러 캐비테이션에 미치는 영향 (Influence of Thru Holes Near Leading Edge of a Model Propeller on Cavitation Behavior)

  • 안종우;박일룡;박영하;김제인;설한신;김기섭
    • 대한조선학회논문집
    • /
    • 제56권3호
    • /
    • pp.281-289
    • /
    • 2019
  • In order to investigate the influence of thru holes near leading edge of model propeller on cavitation behavior, a model propeller with thru holes was manufactured and tested at Large Cavitation Tunnel (LCT). The pressure distribution around the thru hole on propeller blade was numerically calculated to help understand the local flow characteristics related to cavitation behavior. The model propeller is a five bladed propeller which has 2 blades with thru holes and 3 blades with smooth surface. The cavitation observation tests were conducted at angles of $0^{\circ}$ & $6^{\circ}$ using an inclined-shaft dynamometer in LCT. There are big difference on the suction side cavitation behavior each other due to the existence of thru hole. While the blades with thou holes start generation of the sheet cavitation from the leading edge on the suction side, the blades with smooth surface generate the cloud cavitation from the mid-chord. Cavitation on the blades with thru holes shows more similar behavior to those of the full-scale propeller of which the pipe line for air injection is closed. The numerical analysis result shows that the sharp pressure drop occurs around thru holes on the blade. Consequently, the thru hole around leading edge stimulates the cavitation occurrence and stabilizes the cavitation behavior. Based on these results, the effect of thru holes on propeller cavitation behavior behind a model ship should be studied in the future.

열응답 실험 및 열저항 해석을 통한 장심도 수직밀폐형 지중열교환기의 성능 분석 (Performance Analysis of a Deep Vertical Closed-Loop Heat Exchanger through Thermal Response Test and Thermal Resistance Analysis)

  • 심병완;박찬희;조희남;이병대;남유진
    • 자원환경지질
    • /
    • 제49권6호
    • /
    • pp.459-467
    • /
    • 2016
  • 300 m 이상의 장심도 지중열교환기는 도심지나 넓은 부지를 확보가기 어려운 지역에 지열냉난방 시스템을 경제적으로 설치하는데 유리하다. 그러나 실제 시공에서는 여러 가지 문제들로 인하여 보편적으로 시도되지 않았고, 일반적으로 100 ~ 200m 심도로 설치되어 왔다. 본 연구에서는 일반적인 시추공 직경 150 mm에 U 파이프는 50A 규격으로 외경 50 mm의 300 m 심도로 지중열교환기를 설치하였다. 고밀도 PE관은 단위 길이당 비중이 $0.94{\sim}0.96g/cm^3$으로 지열공 내부에 채워진 지하수 영향으로 부력이 존재하여, 이를 개선하기 위해 4.6 kg 무게의 금속으로 제작된 하중밴드 10개조를 설치하여 부력의 영향을 감소시켰다. 지중열교환기의 길이 산정 및 성능평가를 위한 기초조사로서 지반조사 및 열응답실험이 실시되었다. 지반내 온도구배는 100 m 심도까지는 주변 지하수 이용에 의한 영향 등으로 $15^{\circ}C$ 정도의 분포를 보이며 그 하부는 $1.9^{\circ}C/100m$의 지온증온율을 나타내고 있다. 열응답실험은 기존에 설정된 표준 방식으로 48 시간 진행되었으며 평균 주입전력은 17.5 kW이며 평균 순환수 유량은 28.5 l/min, 그리고 평균 입출구 온도차는 $8.9^{\circ}C$로 나타났다. 측정된 지중열전도도는 3.0 W/mk이며, 공내열저항은 0.104 mk/W로 나타났다. Stepwise 평가에서 지중열전도도 변화는 초기 13시간을 제외한 이후에는 표준편차가 0.16으로 매우 안정된 값으로 수렴한 것으로 나타났다. 그리고 공내열저항의 민감도를 분석한 결과 파이프의 구경과 그라우팅 물질의 열전도도가 증가함에 따라 그 값이 미미하게 감소하는 경향을 나타내었다.