• 제목/요약/키워드: Injection materials

검색결과 1,666건 처리시간 0.029초

전하생성층 MoOx와 음극 Al의 두께에 따른 양면발광 적층 OLED의 발광 특성 (Emission Characteristics of Dual Emission Tandem OLED with Charge Generation Layer MoOx and Cathode Al Thickness)

  • 김지현;주성후
    • 한국표면공학회지
    • /
    • 제49권3호
    • /
    • pp.316-321
    • /
    • 2016
  • To study emission characteristics for dual-emission tandem organic light emitting display (OLED), we fabricated blue fluorescent OLED according to thickness variation of $MoO_x$ as charge generation layer and Al as cathode. The bottom emission characteristics of OLED with $MoO_x$ 2, 3, 5 nm thickness showed threshold voltage of 9, 7, 9 V, maximum current emission efficiency of 19.32, 23.18, 15.44 cd/A and luminance of $1,000cd/m^2$ at applied voltage of 17.6, 13.2, 16.5 V, respectively. The top emission characteristics of OLED with $MoO_x$ 2, 3, 5 nm thickness indicated threshold voltage of 13, 10, 13 V, maximum current emission efficiency of 0.17, 0.23, 0.16 cd/A and luminance of $50cd/m^2$ at applied voltage of 22.6, 16.5, 20.1 V, respectively. In case of thicker or thinner than $MoO_x$ of 3 nm, the emission characteristics were decreased because of mismatching of electron and hole in emission layer. The bottom emission characteristics of OLED with Al 15, 20, 25 nm thickness showed threshold voltage of 8, 8, 7 V, maximum current emission efficiency of 18.42, 22.98, 23.18 cd/A and luminance of $1000cd/m^2$ at applied voltage of 16.2, 13.9, 13.2 V, respectively. The reduction of threshold voltage and increase of maximum current emission efficiency are caused by the increase of current injection according to increase of Al cathode thickness. The top emission characteristics of OLED with Al 15, 20, 25 nm thickness indicated threshold voltage of 7, 7, 8 V, maximum emission luminance of 371, 211, $170cd/m^2$, respectively. The top emission OLED of Al cathode with 15 nm thickness showed maximum luminance and it decreased at thickness of 20 nm. These phenomena are caused by the decrease of intensity of emitted light by reduction of optical transmittance according to increase of Al cathode thickness.

제형별 오존 free 플라즈마 안정도 검토 (Stability Review of Formulations Produced with Ozone Free Plasma)

  • 천유연;조하현;백문기;박선주;;빈범호
    • 대한화장품학회지
    • /
    • 제50권2호
    • /
    • pp.143-151
    • /
    • 2024
  • 오존은 무색의 독성 가스로, 질소 산화물과 탄화수소가 태양 광선에 의해 광화학 산화 반응이 일어나면서 생성된다. 낮은 농도여도 호흡기 기관에 영향을 주고, 기침 또는 인체에 해롭다. 화장품 원료 중 질소 플라즈마에서 오존이 생성되는 것을 확인하였고, 1 day 후부터 오존의 농도가 낮아짐을 알 수 있었다. 반면 아르곤 가스로 발생된 오존 free 플라즈마는 오존이 검출되지 않았다. 따라서 오존 free 플라즈마를 활용하여 오존 free 화장품의 제조를 목표로 하였다. 효율적인 플라즈마 처리를 위해 non-sinking 법을 활용하여 층분리 미스트, 토너와 앰플에 주입하고, 안정도를 관찰하였다. 층분리 미스트에서 플라즈마의 주입 성공량이 두 제형보다 많았으나, 토너와 앰플에 비해 급격히 감소함을 확인할 수 있었다. 사용된 오존 free 플라즈마는 저온(4 ℃), RT (25 ℃), 고온(37 ℃, 50 ℃) 조건에서 층분리 미스트, 토너와 앰플의 안정도에 영향이 미치지 않는 것을 확인하였다. 따라서, 본 연구는 오존 free 플라즈마의 제형별 화장품 가능성과 안정성의 중요성을 시사하고 있다.

Cisternography 검사 시 사용되는 방사성의약품의 안정성 확보를 위한 검사도입 및 유용성 평가 (Evaluation of Usefulness and Procedures for Safety of Radiopharmaceuticals in Cisternography)

  • 김다은;유연욱;최호용;김윤철;김영석;원우재;김석기
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.45-49
    • /
    • 2010
  • 뇌조 조영술에 이용되는 방사성의약품들 중 최근에는 Tc-99m DTPA를 이용한 뇌 척수액 영상이 대부분이다. 하지만 Tc-99m DTPA는 사용 시 무균수막염, 근육강직, 경련 등 여러 부작용이 발생할 우려가 있다. 따라서 Tc-99m DTPA의 이러한 부작용의 발생을 사전에 예방하기 위하여 안정성검사를 시행하였으며 그 유용성을 알아보고자 한다. 방사성의약품 Vial검사는 2008년 12월 16일 - 2009년 12월 30일에 뇌조조영술을 시행한 환자(n=12)를 대상으로 시행하였으며, 시술시 사용한 vial내의 DTPA 성분 (Mallinckrodt사의 Techscan-DTPA사용), NaPertechnate radiation dose 및 volume, 생리 식염수량, 환자주사용 용량 및 activity 등을 측정하여 순수 DTPA의 양을 계산하였다. 방사성의약품의 내독소평가(Bacterial endotoxin)는 2008년 12월 16일-2009년 12월 30일에 뇌조 조영술을 시행한 환자(n=12)를 대상으로 하였고, 이 때 사용한 DTPA vial의 Pyrogen test (LAL test)를 시행하였다. 시약이 함유된 Positive/Negative control vial(표준액)에 normal saline 0.2 mL을 주입하고, 동일한 Test control vial(실험액)에 normal saline 0.1mL 와 Tc-99m DTPA 0.1 mL로 주입하였으며 Digital hot plate에서 $37.5^{\circ}C$로 1시간 반응시킨 후 응고여부를 표준액과 대조하여 관찰하였다. 안정적인 제조절차 준수는 보존제(방부제)가 없는 미 개봉한 CaNa3 DTPA kit를 사용하였으며 Tc-99m DTPA는 한 Vial당 한명의 환자선량으로 뽑아 투여한다. 이때 적정 용량을 맞추기 위해 0.9% NaCl 멸균 생리 식염수를 사용하여 희석하였다. 방사성의약품 Vial검사는 측정된 성분값들로 순수 DTPA의 양을 얻어내었으며 이는 2가지의 계산식을 이용하여 선량 대비 DTPA의 용량(평균 0.88 mg), 용량 대비 DTPA의 용량(평균 0.74 mg)을 도출해내었다. 방사성의약품의 내독소 평가에서는 동일한 조건으로 시험(n=12)을 시행한 결과 모두 Bacterial endotoxin이 기준치인 단위 선량 당 14 endotoxin units (EU)미만의 반응인 Negative(-)로 나왔다. 안정적인 제조절차 준수에서는 검사 관련 sheet를 만들어 작성 및 제조절차 준수 여부를 확인하였으며 결과 모두 준수하여 제조과정 내에서 방사성의약품에 의하여 발생할 수 있는 부작용이 없었다. Tc-99m DTPA를 이용한 Cisternography 검사 시 항상 방사성의약품의 안정성문제가 제기되어 왔다. 수막강 내 주입용 방사성의약품으로서 제조 및 사용 시 불안정한 취급으로 부작용이 발생할 우려가 있으며, 이에 따른 사용지침이 확립되어야 한다고 생각되었다. 수막강 내 주입용 방사선의약품으로써 free acid 혹은 sodium을 포함하는 DTPA는 적절하지 않으며, 반면 Calcium이 포함된 DTPA는 적절한 것으로 알려져 있다. 위와 같이 Techscan-DTPA(Mallinckrodt): CaNa3으로 간단하며 편리하게 안정성검사를 시행할 수 있었으며 각 검사결과(n=12) 안정성검사를 모두 통과하여 검사 시 동반될 수 있는 부작용은 나타나지 않았다. 앞으로 위와 같은 SOP (Standard Operating Procedures)를 적용하여 보다 쉽고, 편리하게 안정성검사를 시행할 수 있으리라 사료된다.

  • PDF

반탄화목분 천연재료 혼합응집제의 안정성 및 슬러지 에너지화 가능성 평가에 관한 연구 (A Study on the Stability and Sludge Energy Efficiency Evaluation of Torrefied Wood Flour Natural Material Based Coagulant)

  • PARK, Hae Keum;KANG, Seog Goo
    • Journal of the Korean Wood Science and Technology
    • /
    • 제48권3호
    • /
    • pp.271-282
    • /
    • 2020
  • 하수처리장은 도시를 구성하는 사회기반시설물로 2017년 하수도 통계 기준 국내 하수도 보급률은 94%에 달하고 있다. 국내 하수처리장에서 PAC(Poly Aluminum Chloride)의 사용량이 58%를 차지하고 있으나 PAC의 경우 품질기준상 불순물(중금속) 함량이 높음에도 불구하고, 기준 강화나 기술적 품질개선이 제대로 이루어지지 않아 응집제 과다 주입 시 2차 오염문제가 대두되고 있다. 또한, 약품사용량이 증가함에 따라 2017년 기준 연간 하수슬러지 발생량과 슬러지 재이용의 필요성 또한 증대되고 있다. 이에 본 연구에서는 반탄화목분 천연재료 혼합응집제를 이용한 수처리 시 혼합응집제 주입에 따른 중금속류에 대한 안정성을 평가하고, 하수슬러지의 침강성 및 하수슬러지 발열량 평가를 통해 슬러지 재이용의 가능성을 검증하고자 한다. 반탄화목분 천연재료 혼합응집제와 PAC(10%)의 중금속류(Cr, Fe, Zn, Cu, Cd, As, Pb, Ni) 분석 결과 Cr, Cd, Pb, Ni, Hg의 경우 검출되지 않았으며, Zn의 경우 반탄화목분 천연재료 혼합응집제에서 먹는물 수질기준에서 고시한 Zn의 농도가 3mg/L인 것에 비해 0.007 mg/L로 극소량만 검출되었다. Fe, Cu, As의 경우 PAC(10%)를 주입한 경우가 반탄화목분 천연재료 혼합응집제 보다 최대 2배 이상 검출되는 것으로 나타났다. 또한, 슬러지 침강성 분석 결과 반탄화목분 천연재료 혼합응집제가 기존 응집제인 PAC(10%)에 비해 최대 2배 빠르게 침강하는 것으로 반탄화목분 혼합응집제의 침강성이 PAC(10%)보다 우수한 것으로 나타났다. 반탄화목분 천연재료 혼합응집제를 주입하여 발생된 하수슬러지의 건조기준 저위발열량은 3,378 kcal/kg이며, PAC(10%) 응집제를 주입하여 발생된 하수슬러지의 건조기준 저위발열량은 3,171 kcal/kg으로 두 응집제 모두 화력발전소의 보조연료 구비조건을 만족하였으나, 본 연구에서 개발한 반탄화목분 천연재료 혼합응집제를 사용할 경우 기존의 응집제보다 200 kal/kg 정도 높은 슬러지 발열량을 확보할 수 있음을 확인하였다. 따라서, 반탄화목분 혼합응집제를 이용하여 수처리를 수행할 경우 기존의 응집제인 PAC(10%)보다 중금속류에 대해 안정적이며, 우수한 슬러지 침강성과 높은 발열량을 갖는 슬러지를 생성하여 환경적으로 안정적이며, 효율적인 활용이 가능할 것으로 판단된다.

배양골세포 이식이 치조골재생에 미치는 영향 (Effects Of Cultured Bone Cell On The Regeneration Of Alveolar Bone)

  • 정순준;허익;박준봉;이만섭;권영혁
    • Journal of Periodontal and Implant Science
    • /
    • 제26권1호
    • /
    • pp.1-26
    • /
    • 1996
  • This study was performed to estimate the effects of cultured bone cell inoculated on porous type hydroxyaptite for the regeneration of the artificial alveolar bone defect. In this experiment 3 beagle dogs were used, and each of them were divided into right and left mandible. Every surgical intervention were performed under the general anesthesia by using with intravenous injection of Pentobarbital sodium(30mg/Kg). To reduce the gingival bleeding during surgery, operative site was injected with Lidocaine hydrochloride(l:80,000 Epinephrine) as local anesthesia. After surgery experimental animal were feeded with soft dietl Mighty dog, Frisies Co., U.S.A.) for 1 weeks to avoid irritaion to soft tissue by food. 2 months before surgery both side of mandibular 1st premolar were extracted and bone chips from mandibular body were obtained from all animals. Bone cells were cultured from bone chips obtained from mandible with Dulbecco's Modified Essential Medium contained with 10% Fetal Bovine Serum under the conventional conditions. Porous type hydroxyapatite were immerse into the high concentrated cell suspension solution, and put 4 hours for attachin the cells on the surface of hydroxyapatite. Graft material were inserted on the artificial bone defect after 3 days of culture. Before insertion of cellinoculated graft material, scanning electronic microscopic observation were performed to confirm the attachment and spreading of cell on the hydroxyapatite surface. 3 artificial bone defects were made with bone trephine drill on the both side of mandible of the experimental animal. First defect was designed without insertion of graft material as negative control, second was filled with porous replamineform hydroxyapatite inoculated with cultured bone marrow cells as expermiental site, and third was filled with graft materials only as positive control. The size of every artificial bone defect was 3mm in diameter and 3mm in depth. After the every surgical intervention of animals, oral hygiene program were performed with 1.0% chlorhexidine digluconate. All of the animals were sacrificed at 2, 4, 6 weeks after surgery. For obtaining histological section, tissus were fixed in 10% Buffered formalin and decalcified with Planko - Rycho Solution for 72hr. Tissue embeding was performed in paraffin and cut parallel to the surface of mandibular body. Section in 8um thickness of tissue was done and stained with Hematoxylin - Eosin. All the specimens were observed under the light microscopy. The following results were obtained : 1. In the case of control site which has no graft material, less inflammatory cell infiltration and rapid new bone forming tendency were revealed compared with experimental groups. But bone surface were observed depression pattern on defect area because of soft tissue invasion into the artificial bone defect during the experimental period. 2. In the porous hydroxyapatite only group, inflammatory cell infiltration was prominet and dense connective tissue were encapsulated around grafted materials. osteoblastic activity in the early stage after surgery was low to compared with grafted with bone cells. 3. In the case of porous hydroxyapatite inoculated with bone cell, less inflammatory cell infiltration and rapid new bone formation activity was revealed than hydroxyapatite only group. Active new bone formation were observed in the early stage of control group. 4. The origin of new bone forming was revealed not from the center of defected area but from the surface of preexisting bony wall on every specimen. 5. In this experiment, osteoclastic cell was not found around grafted materials, and fibrovascular invasion into regions with no noticeable foreign body reaction. Conclusively, the cultured bone cell inoculated onto the porous hydroxyapatite may have an important role of regeneration of artificial bone defects of alveolar bone.

  • PDF

용존성 유기물질 및 탁도 제거를 위한 반탄화목분 천연재료 혼합응집제의 적용성에 관한 연구 (A Study on the Applicability of Torrefied Wood Flour Natural Material Based Coagulant to Removal of Dissolved Organic Matter and Turbidity)

  • PARK, Hae Keum;KANG, Seog Goo
    • Journal of the Korean Wood Science and Technology
    • /
    • 제48권4호
    • /
    • pp.472-487
    • /
    • 2020
  • 급격한 산업화로 인한 이상기후의 발생으로 매년 수질관리 중요성과 관리비용이 증대되고 있는 실정이다. 이에 국내의 경우 수질오염의 주요 원인물질인 총인, 총질소의 관리를 위해 하수처리장에서 응집제를 투입하여 유기물질을 처리하고 있다. 그러나 PAC(Poly Aluminium Chloride)의 경우 응집제 과다 주입 시 2차 오염문제가 발생될 수 있다. 이에 국내에서는 천연재료를 혼합한 응집제를 이용한 응집제의 적용성에 관한 연구가 진행되고 있다. 따라서 본 연구에서는 하수처리장의 1차 침전지 유출수를 대상으로 PAC와 반탄화목분의 최적 혼합비율을 도출하기 위해 수질 오염물질인 T-P, T-N 및 탁도를 분석하여 개발한 혼합응집제의 적용성 평가를 하고자 한다. PAC(10%)와 반탄화목분 함유량이 1%가 되는 조건에서 T-P의 경우 최대 92%의 제거효율이 나타났으며, T-N의 경우 약 22%의 제거효율이 나타났다. 이는 혼합응집제와 동일한 양전하성 유기물질이 다수 포함된 T-N의 제거가 잘 이루어지지 않은 것으로 판단된다. 탁도는 약 91%의 제거효율이 나타났다. 이에 반탄화목분 1%가 최적 첨가량이라고 판단하였으며, PAC 농도를 저감하여 유기물질 제거효율을 분석한 결과, PAC 농도 7%에서 T-P의 경우 최대 91%의 높은 제거효율이 나타났으며, T-N의 경우 32%의 제거효율이 나타났다. 탁도의 경우 최대 90%의 제거효율이 나타났다. 또한, PAC(10%)와 응집성능 비교실험을 수행하여 본 연구에서 제조한 반탄화목분 1% 함유량 기준에서 혼합응집제를 이용하여 응집공정을 수행할 경우 PAC 농도를 30-50%로 저감할 수 있으며, 시판 응집제와 유사한 성능을 확보할 수 있을 뿐만 아니라 PAC 주입량이 저감되어 경제적 효과를 확보하고, 2차 오염 문제를 저감하는 안정적인 수처리를 수행할 수 있을 것이라고 사료된다.

나노급 다이아몬드 파우더에 ALD로 제조된 ZnO 박막 연구 (Microstructure of ZnO Thin Film on Nano-Scale Diamond Powder Using ALD)

  • 박종성;송오성
    • 한국진공학회지
    • /
    • 제17권6호
    • /
    • pp.538-543
    • /
    • 2008
  • 나노급 다이아몬드는 최근 폭발법이나 증착법에 의한 신공정으로 100 nm 이하의 분말형태의 제조가 가능하다. 나노급 다이아몬드의 소결을 이용하면 이상적인 연마기기의 제작이 가능하다. 이러한 나노급 다이아몬드의 소결 공정에서 생기는 비이상적인 나노결정의 결정립성장과 다이아몬드 결합장애를 방지하기 위해서 나노급 무기물을 균일하게 코팅하는 공정개발이 필요하다. 본 연구에서는 나노급 다이아몬드의 소결 특성을 향상시키기 위해서 ALD(atomic layer deposition)을 이용하여 진공에서 $20{\sim}30\;nm$ 두께의 ZnO 박막을 코팅해 보았다. 나노급 다이아몬드 분말 전면에 경제적으로 ZnO ALD를 위해서 기존의 기계적 진동효과 또는 전용 fluidized bed reactor를 대치하여 새로이 20 mm 석영튜브 안에 다이아몬드 분말을 넣고 다공성 유리필터로 막은 후 펄스와 퍼지 공정시의 압력에 의한 다이아몬드의 부유를 이용한 변형된 fluidized bed 공정을 채용하였다. 다공성 유리필터로 양쪽이 막힌 석영튜브 안에 전구체 DEZn (diethylzinc : $C_4H_{10}Zn$)와 반응기체 $H_2O$를 사용하여 ZnO 박막을 캐니스터 온도 $10^{\circ}C$에서 원자층증착하였다. 공정 순서 및 반응물질 주입 시간은 DEZn pulse-0.1초, DEZn purge-20초, $H_2O$ pulse-0.1초, $H_2O$ purge-40초와 같이 설정하였으며, 이 네 단계를 1 cycle로 정의하여 100 cycle 반복 실시하였다. 다이아몬드 분말과 ZnO 박막이 증착된 다이아몬드 분말의 미세구조를 확인하기 위하여 투과전자현미경 (transmission electron microscope)을 이용하였다. TEM 측정결과, ALD 증착 전 나노급 다이아몬드 분말의 직경이 약 $70{\sim}120\;nm$이었고 사면체, 육면체 등의 다양한 형태를 보임을 확인하였다. ZnO 박막이 ALD코팅된 다이아몬드 분말의 직경은 약 $90{\sim}150\;nm$이었고, 다이아몬드 분말과 ZnO의 명암차이에 의해 약 $20{\sim}30\;nm$ 두께의 균일한 ZnO 박막이 다각형 형태의 다이아몬드 파우더 표면에 성공적으로 증착되었음을 확인하였다.

6 L급 압축착화 기관에서 천연가스-디젤 반응성 조정 연소 시 부하에 따른 배기 재순환율이 출력 및 열효율에 미치는 영향 분석 (Effects of Exhaust Gas Recirculation on Power and Thermal Efficiency of Reactivity Controlled Compression Ignition in Different Load Conditions with a 6-L Engine)

  • 이선엽;이석환;김창기;이정우
    • 한국가스학회지
    • /
    • 제24권6호
    • /
    • pp.1-10
    • /
    • 2020
  • 반응성 조정 압축착화 (Reactivity Controlled Compression Ignition, RCCI) 연소는 착화원인 디젤 연료를 압축 행정 중 이른 시점에 미리 분사하여, 공기와 미리 섞여 들어온 천연가스 연료뿐만 아니라 디젤 연료 자체도 미리 연소 전에 공기와 혼합하여 착화를 이루는 전체 예혼합 혼소(Dual-fuel combustion) 방식의 일종이다. 따라서 기존의 혼소 방식 중에서도 RCCI 연소는 질소산화물(Nitrogen Oxides, NOx) 및 매연(Smoke)을 획기적으로 줄일 수 있고, 또한 높은 열효율을 유지할 수 있는 장점을 지니고 있다. 특히 연소 중 NOx의 발생은 연소 온도와 국부적인 당량비에 관계된 상황에서 당량비를 낮추기 위해 예혼합율을 높이는 시도뿐만 아니라, 연소 온도 감소를 위한 배기재순환(Exhuast Gas Recirculation, EGR)을 적용하는 것이 효과적이다. 그러나 배기재순환은 대개의 경우 터보차저의 압축기 전단에서 추출하는 HP-EGR(High Pressure-EGR) 방식을 적용하는 경우가 많으므로, EGR율을 높일 경우 터빈으로 공급되는 배기의 양이 줄어 배기 엔탈피 감소로 인해 과급이 줄어드는 악영향을 초래할 수 있다. 따라서 본 연구에서는 서로 다른 두 운전조건에서 천연가스-디젤 RCCI 연소를 시행할 때, EGR율 변화에 따른 엔진 시스템의 제동 출력 및 열효율의 변화에 대하여 실험적으로 분석하였다. 실험 조건은 1,200 rpm/29 kW 수준의 조건과 1,800 rpm/90 kW 이하 조건에서 수행하였으며 NOx와 smoke의 배출조건은 Tier-4 final 배기규제를 기준으로 삼았으며 엔진의 내구성을 고려하여 최고 연소압력은 160 bar를 넘지 않게 제어하였다. 그 결과 1,200 rpm/29 kW 조건에서는 EGR율을 4에서 30 %로 높이더라도 출력 및 열효율의 변화는 미미하였으나, 1,800 rpm 조건에서는 EGR율을 4에서 28 %로 증가할 경우 최대 과급 압력이 2.3에서 1.8 bar로, 최고 출력은 90에서 65 kW로, 열효율은 37에서 33 %로 감소함을 알 수 있었다. 따라서 효과적인 EGR공급을 위해서는 현재 압축기 전단에서 추출하는 EGR을 후단에서 추출하는 LP-EGR (Low Pressure EGR) 시스템이 효과적일 수 있음을 시사한다.

기체크로마토그래프법을 이용한 [F-18]FDG의 잔류용매 분석 (Analysis of Residual Solvents of [F-18]FDG Using Gas Chromatography)

  • 김동일;이일중;김시활;지용기;석재동
    • 핵의학기술
    • /
    • 제15권2호
    • /
    • pp.26-29
    • /
    • 2011
  • [F-18]FDG 제조 후 품질관리를 수행하는데 있어서 품질관리 항목 중 잔류용매 시험은 최종 [F-18]FDG 바이알에 잔류하는 유기용매를 측정하기 위한 것이다. 본 연구는 자동합성장치에 따른 최종 [F-18]FDG 바이알에 잔류하는 유기용매의 종류를 파악하고, 잔류량을 측정하고자 하였다. 불꽃이온화 검출기(Flame Ionization Detector)가 장착된 기체크로마토그래프(Agilent Technologies 7890A)를 이용하여 제조 후 일주일 이내의 밀봉 바이알에 보관한 [F-18]FDG를 기체크로마토그래프에 $1.0{\mu}L$ 씩 주입한 후 각 피크영역을 구하였다. FASTlab은 평균이 에탄올 72 ppm, 아세토니트릴 54 ppm, 초산 1030 ppm으로 나타났으며, TRACERlab MX는 평균이 에탄올 439 ppm 및 아세토니트릴 79 ppm이 검출되어 모두 의약품 잔류용매기준의 허용량 이내에 있었다. [F-18]FDG 주사액에 있는 잔류용매는 모두 허용량 이내로 환자검사에 사용하는데 적합하였다. 또한 최종 [F-18]FDG 바이알에 있을 수 있는 초산의 최대 이론량은 1167 ppm으로 따로 검량을 하지 않아도 되는 것으로 나타났다. 이 결과에서는 자동합성장치에 따라 방사성의약품의 잔류용매의 종류 및 양이 다를 수 있음을 보였다.

  • PDF

동적 타액선 신티그라피에서 기능적 매개변수 지표를 활용한 정량 분석의 유용성 (Usefulness of the quantitative analysis by using the functional parameter index from dynamic salivary glands scintigraphy)

  • 신채호;김봉수;조용귀;조진우;진성은;표성재
    • 핵의학기술
    • /
    • 제19권2호
    • /
    • pp.81-86
    • /
    • 2015
  • 동적 타액선 신티그라피는 비침습적인 방법으로 타액선의 기능을 평가하는데 널리 사용되어 왔다. 본 연구에서는 타액선 신티그라피의 시간-방사능 곡선에서 다양한 기능적 매개변수지표를 측정하고 구강건조증 환자 그룹과 건강한 Control 그룹과 비교를 통해 유용성을 알아보고자 한다. 2014년 12월부터 2015년 2월까지 구강 건조증으로 내원하여 동적 타액선 신티그라피를 시행한 환자 그룹 30명과 건강한 Control 그룹 10명을 대상으로 하였다. 검사방법은 370 MBq의 $^{99m}Tc$-과산화테크네슘을 정맥으로 순간 주사 후 약 30분간 동적 타액선 신티그라피를 연속 촬영하였으며, 주사 후 20분째에 최타 자극제로 비타민C 파우더를 이용하였다. 정량분석은 이하선과 악하선의 시간-방사능 곡선을 통해 기능적 매개변수 지표를 획득하고, 통계 프로그램을 이용하여 구강 건조증 환자와 건강한 Control 그룹과 비교하였다. 동적 타액선 신티그라피에서 이하선과 악하선의 기능적 매개변수 지표인 섭취율(Uptake Ratio, UR), 최대 방사능 시간(Time at Maximum counts, Tmax), 최소 방사능 시간(Time at Minimum counts, Tmin), 최대 축적율(Maximum Accumulation, MA), 축적속도(Accumulation Velocity), 최대 배출율(Maximum Secretion, MS), 최대 자극 배출율(Maximum Stimulation Secretion, MSS), 배출속도(Secretion Velocity, SV)를 각각 측정하였다. 구강 건조증 환자와 건강한 Control 그룹간의 이하선과 악하선의 기능적 매개변수 지표 비교에서는 최소 방사능 시간을 제외한 모든 지표에서 건강한 Control 그룹이 환자 그룹에 비하여 유의성 있게 높게 측정되었으며, 시간에 따른 변화량도 Control 그룹이 환자 그룹에 비하여 유의성 있게 변화량이 크게 측정 되었다. 동적 타액선 신티그라피에서 다양한 기능적 매개변수 지표를 이용한 정량분석은 구강 건조증 환자의 타액선 기능을 평가하는데 객관적이고 표준화된 정보를 제공해 줄 것으로 사료된다.

  • PDF