• Title/Summary/Keyword: Injection level

Search Result 1,594, Processing Time 0.023 seconds

Effects of Mercuric Chloride on the Lipid Peroxidation and Oxygen Free Radical scavenging Enzymes Activities in the Liver of Rats (염화 제2수은이 흰쥐 간장에서의 지질 과산화와 Oxygen Free Radical 제거 효소 활성도에 미치는 영향)

  • 신인철;고현철
    • Biomolecules & Therapeutics
    • /
    • v.2 no.3
    • /
    • pp.298-302
    • /
    • 1994
  • Wistar albino rats were injected subcutaneously with mercuric chloride (5 mg/kg) to define the early biochemical determinants that participate in the pathogenesis of mercuric chloride-induced hepatotoxicity, especially focusing on oxygen free radicals, we studied malondialdehyde(MDA) level and the activities of catalase and superoxide dismutase in the liver of rats at 24, 48 and 72 hr after the injection of mercuric chloride. MDA levels at 24, 48 and 72 hr after the injection of mercuric chloride increased as compared with that of control group. The activities of catalase and superoxide dismutase at 24, 48 and 72hr after the injection of mercuric chloride decreased as compared with that of control group. These results suggest that the depression of the activities of catalase and superoxide dismutase resulting from excessive oxygen free radicals is an important determinant in pathogenesis of mercuric chloride-induced hepatotoxicity.

  • PDF

Intracranial Chronic Subdural Hematoma Presenting with Intractable Headache after Cervical Epidural Steroid Injection

  • Kim, Myungsoo;Park, Ki-Su
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.2
    • /
    • pp.144-146
    • /
    • 2015
  • Postdural punctural headache (PDPH) following spinal anesthesia is due to intracranial hypotension caused by cerebrospinal fluid (CSF) leakage, and it is occasionally accompanied by an intracranial hematoma. To the best of our knowledge, an intracranial chronic subdural hematoma (CSDH) presenting with an intractable headache after a cervical epidural steroid injection (ESI) has not been reported. A 39-year-old woman without any history of trauma underwent a cervical ESI for a herniated nucleus pulposus at the C5-6 level. One month later, she presented with a severe headache that was not relieved by analgesic medication, which changed in character from being positional to non-positional during the preceding month. Brain magnetic resonance imaging revealed a CSDH along the left convexity. Emergency burr-hole drainage was performed and the headache abated. This report indicates that an intracranial CSDH should be considered a possible complication after ESI. In addition, the event of an intractable and changing PDPH after ESI suggests further evaluation for diagnosis of an intracranial hematoma.

Comparativy Characteristics between Microstrip-Line Resonator(HR) and Dielectric Resonator(DR) for Injection-Locked Oscillators (ILOs)

  • Kim, Nam-Young;Kim, Jong-Heon;Hong, Ui-Seok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.239-244
    • /
    • 1997
  • A hair-pin shaped microstrip-line resonator and a dielectric resonator for injection-locked oscillators have been designed and fabricated for the comparative studying of their characteristics. In general, a commonly used dielectric resonator shows lower phase noise value than hair-pin resonator in the free-running mode. In the injection-locked mode, however, a hair-pin resonator is superior to the dielectric resonator; the wider tuning range, the 22% improved locking bandwidth, the lower noise effect, the short term stability, and the higher power level. The planar structure of a hair-pin shaped microstrip-line resonator will be easily applied to monolithic microwave integrated circuits.

  • PDF

Synchronous Carrier-based Pulse Width Modulation Switching Method for Vienna Rectifier

  • Park, Jin-Hyuk;Yang, SongHee;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.604-614
    • /
    • 2018
  • This paper proposes a synchronous switching technique for a Vienna rectifier that uses carrier-based pulse width modulation (CB-PWM). A three-phase Vienna rectifier, similar to a three-level T-type converter with three back-to-back switches, is used as a PWM rectifier. Conventional CB-PWM requires six independent gate signals to operate back-to-back switches. When internal switches are operated synchronously, only three independent gate signals are required, which simplifies the construction of gate driver circuits. However, with this method, total harmonic distortion of the input current is higher than that with conventional CB-PWM switching. A reactive current injection technique is proposed to improve current distortion. The performance of the proposed synchronous switching method and the effectiveness of the reactive current injection technique are verified using simulations and experiments performed with a set of Vienna rectifiers rated at 5 kW.

Tomographic reconstruction of Asymmetric Spray by Direct Sampling Method (직접샘플링에 의한 비대칭 분무의 토모그래피 재구성)

  • Lee, C.H.;Won, J.C.
    • Journal of ILASS-Korea
    • /
    • v.7 no.4
    • /
    • pp.9-15
    • /
    • 2002
  • Convolution Fourier transformation tomographically reconstructs the spatially resolved spray injection rate from direct measuring cells. Asymmetric sprays generated from a twin-hole air shroud injector are tested with 12 equiangular projections of measurements. For each projection angle, line of sight integrated injection rate was measured at 35 positions with equal spacing measuring cells of 3 mm in width, 100 mm in length, 55 mm in depth and 0.5 mm thickness of separating wall. Interpolated data between the projection angles effectively increase the number of projections, which significantly enhances the signal-to-noise level in the reconstructed data. This modified convolution Fourier transformation scheme predicts well the structure of asymmetric sprays. Comparative study has been made between sprays with and without air shrouding. Tomograhpic reconstruction of injection rate from direct measuring cells obtained can be used to estimate the accuracy of volume fraction of spray from the LDPA tomographic reconstruction.

  • PDF

The Effect of Dual Clutch Transmissions on the Stability Emissions Characteristic in a Gasoline Direct Injection Engine (GDI 엔진에 DCT 적용에 따른 배기 배출물 특성에 미치는 영향)

  • Kim, Kwang Lae;Roh, Hyun Gu
    • Journal of ILASS-Korea
    • /
    • v.20 no.3
    • /
    • pp.156-161
    • /
    • 2015
  • This paper described the effect of dual clutch transmissions on the stability emissions characteristic in a GDI engine at vehicle Inspection and Maintenance(I/M) program. In order to investigate the influence of direct injection gasoline engine with DCT, the experimental apparatus consisted of GDI engine with 4 cylinder, dynamometer and exhaust emissions analyzer. Analyzed emission gas include CO, HC and NOx results that DCT vehicle in the case of NOx, HC in automatic transmission vehicles less than 1/2 level was confirmed to be exhausted. However vehicle specific power increases CO also has increased.

Comparative Performances between Hair-pin Shaped Microstrip-line Resonator and Dielectric Resonator for Injection Locked Oscillators at 11GHz

  • Lee, Du-Han;Kim, Kye-Hun;Kim, Nam-Youn;Kim, Jong-Heon;Hong, Ui-Seok
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.6
    • /
    • pp.171-176
    • /
    • 1997
  • A hair-pin shaped microstrip-line resonator and dielectric resonator for injection-locked oscillators have been designed and fabricated for the comparative studying of their performances. In general, a commonly used dielectric resonator shows lower phase noise value than hair-pin resonator in the free-running mode. In the injection-locked mode, however, a hair-pin resonator is superior to the dielectric resonator, the wider tuning range, the 22% improved locking bandwidth, the lower noise effect, the short term stability, and the higher power level. The planar structure of a hair-pin shaped microstrip-line resonator will be easily applied to monolithic microwave integrated circuits.

  • PDF

A Study on the Emission Characteristics of NOx in Medium Speed Diesel Engine (중속 디젤기관의 질소산화물 배출특성에 관한 연구)

  • 우석근;윤건식;윤영환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.4
    • /
    • pp.526-534
    • /
    • 2000
  • In this study, the characteristics of exhaust emissions in medium speed diesel engine under various operating conditions were investigated through experiments to derive the optimum conditions for minimizing the exhaust emissions, especially, nitrogen oxides. The 355 KW$\times$1200 rpm medium speed diesel engine was intensively examined to investigate the trend of exhaust emissions in case that the parameters affecting combustion conditions such as fuel injection timing, intake air temperature and pressure, engine speed and load were changed. The exhaust emissions for 9 sets of medium speed diesel engine were analyzed in addition. From this study, NOx level could be reduced by 30~50% through the adjustment of retarded fuel injection timing, lowered intake air temperature and increased charging air pressure.

  • PDF

A Study on Determination of Economic Filling Weight in the Powder Injection Process of the Pharmaceutical Industry (제약산업의 분말 주사제 공정에서의 경제적 충진량 결정에 관한 연구)

  • 신일환;이영해
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.22 no.52
    • /
    • pp.9-20
    • /
    • 1999
  • The standard deviation is constant in the progress of Powder Injection Filling, The setting value of the filling amount can modify the numerical rate. Since high level of the numerical rate can get the effect of reducing the material cost, it improves the productivity by permitting the possibility of the economical production. Consequently, this thesis analyzed and suggests the numerical model which consider the economical factors of the Powder Injection Shaping progress, and I try to reinforce the competitive powder of the domestic medicine manufacture industry which face the wave of globalism and evolutionism.

  • PDF

Does subepineural injection damage the nerve integrity? A technical report from four amputated limbs

  • Diwan, Sandeep;Nair, Abhijit;Sancheti, Parag;Van Zundert, Andre
    • The Korean Journal of Pain
    • /
    • v.34 no.1
    • /
    • pp.132-136
    • /
    • 2021
  • Local anesthetic (LA) injection outside the sheath in epineural or paraneural connective tissue is considered safe practice among regional anesthesiologists. There is limited evidence as to whether neurological complications occur if LA is injected inside the sheath (subepineural - intraneural). We performed ultrasound guided injections at the level of undivided sciatic nerve in four amputated lower limbs. In two specimens, LA was injected in epineural connective tissue (paraneural tissue) and in another two specimens by penetrating the outer nerve sheath (hyperechoic epineurium). Ultrasonography demonstrated an increase in the size of nerve and macroscopic findings revealed fascicular tracings with sub-epineural injections. Limbs were sent for histological analysis in formalin containers. Pathologist performed the analysis which demonstrated an intact perineurium and a breach in the epineurium. We conclude that sub-epineural injections are unsafe and injection should be done in paraneural tissue to ensure safety and avoid unwanted neurological sequelae after the block.