• Title/Summary/Keyword: Injection interval

Search Result 266, Processing Time 0.03 seconds

Ground Speed Control of a Direct Injection Sprayer

  • Koo, T.M.;Sumner, H.R.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.500-510
    • /
    • 1996
  • A Direct injection -mixing total -flow -control sprayer was developed and evaluated . The system provided precise application rates and minimized operator exposure to chemicals as well as providing a possibility for recycling container so f unused chemicals that can causes environmental contamination. Chemicals were metered and injected proportionally to the diluent flow rate to provide constant concentrations. The main diluent flow was varied in response to changes in travel speed. Experimental variables of the sprayer were the control interval, the sensitivity of flow regulating valve, the tolerance of control object and the sensitivity of the injection pump system. The optimal performance of the flow control system was with an average response time of 8.5 sec at an absolute steady state of error of 0.067 L/min (0.8% of flow rate). The average response time of the injection rate was -0.53 sec and the coefficient of variation (CV) of concentration was 3.2%.

  • PDF

Smart Card Reader기 Connector 조립 및 Vision 검사용 자동화기기 개발에 관한 연구

  • 노병옥;성하경
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.543-548
    • /
    • 1994
  • This is the paper on the development of assemnly automation and visual inspection system for smart card reader connector. The automation consists of 3 main process injection, assembly and inspection. During the injection, the main pin of a reel. transferred under uniform tension, is cut with an injection interval and positioned precisely to an injection mold by roll feeder after injection. The main base is stacked to a magazine for main pin's exact positionning to a mold . For last effective production, The turn table and pick & place are driver with gears and came by a single monter. We developed the small parts handling technigue for stable supply of micro ist pin and 2nd pin and could determine the orientation and position of those pins. For reliable inspection, We used the vision system which examins the guality of arranged pins with a CCD camera. The connector models which can be manufactured with this system are 8 pin and 10 pin type. The user can select the connector model for production and adjust the torerable error range during the inspection of arranged pins.

  • PDF

Effect of Recombinant Bovine Somatotropin (${\gamma}$ bST) Administration on bST Levels in Milk of Cows

  • Park, Jeongeun;Park, Myung-Ja;Jaeho Chin;Park, Jongsei;Kim, Jooho
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1995.04a
    • /
    • pp.127-127
    • /
    • 1995
  • The present study was conducted to examine the effect of recombinant bovine somatotropin(${\gamma}$ bST), which was administered to cow to promote milk production, on bST levels in milk. Fourteen cows were divided into two groups: 1) control cows received neither y bST nor vehicle, 2) treated cows were administered twice at two-week interval with 500mg ${\gamma}$ bST each cow by subcutaneous injection. Milk samples were taken on day 0 (prior to injection), day 7 (7 days after 1st injection), day 21 (7 days after 2nd injection) and day 35 (21 days after 2nd injection).

  • PDF

Experimental Studies on the Pulmonary Toxicity of Combined Bleomycin and Cyclophosphamide Administration in Rats (Bleomycin 과 Cyclophosphamide 의 병용투여가 흰쥐의 폐독성에 미치는 영향)

  • Na, Seok-Ju;Gwak, Mun-Seop
    • Journal of Chest Surgery
    • /
    • v.22 no.6
    • /
    • pp.914-920
    • /
    • 1989
  • Bleomycin and cyclophosphamide are widely used and effective anti-cancer agents for treatment of various forms of cancer. Bleomycin has no myelotoxicity, but because of potential risk of pulmonary complications including interstitial pneumonitis and idiopathic interstitial pulmonary fibrosis, it has been limited in use. Some investigator has also suggested that cyclophosphamide can induce pulmonary toxicity like bleomycin. Recently, The combination chemotherapy including bleomycin and cyclophosphamide has been adopted effectively in some types of cancer. But there are no available literatures for synergistic effect of pulmonary toxicity in combination chemotherapy including these two drugs. We tried this study to observe synergism of pulmonary toxicity using these two drugs in rats. The animals were divided into five groups: group 1 received intra-peritoneal injection of saline, group 2-a received only bleomycin 0.1 mg [0.4 mg/kg] by intra-peritoneal injection twice a week, group 2-b received only bleomycin 0.5 mg [2 mg/kg] by intra-peritoneal injection twice a week, group 3-a received bleomycin 0.1 mg [0.4 mg/kg] twice a week +cyclophosphamide 5 mg [20 mg/kg] two weeks interval by intra-peritoneal injection, group 3-b received bleomycin 0.5 mg [2 mg/kg] twice a week + cyclophosphamide 5 mg[20 mg/kg] two weeks interval by intra-peritoneal injection. The animals were sacrificed at 2 and 4 weeks later. Lung tissues were obtained and observed by light microscope. The results are as follows: 1. The pathologic findings of group 1 were normal without change. 2. There was no difference between group 2-a and group 3-a at 2 weeks later, group 3-a, however, revealed more severe change in lung tissue at 4 weeks later compared with group 2-a. 3. In group 3-b there was more severe pulmonary injury compared with group 2-b at 2 and 4 weeks later. We conclude that the combined administration of bleomycin and cyclophosphamide induce more severe pulmonary toxic effect than bleomycin administration alone and the combination chemotherapy including these two drugs will be require special attention to selection of the dose of each drug.

  • PDF

A Comparison of Patient-Controlled Analgesia and Conventional Intramuscular Opioid Regimen in Relation to their Post-Operative Pain Control and Side Effects (수술후 통증 관리의 Patient-Controlled Analgesia와 마약류의 전통적인 근육내 주사와의 비교)

  • Lee, Sang-Hun;Lee, Jin-Kyung;Lee, Kyn-Chang;Woo, Nam-Sik;Lee, Ye-Chul
    • The Korean Journal of Pain
    • /
    • v.6 no.1
    • /
    • pp.55-59
    • /
    • 1993
  • Using a visual analogue scale, we compare the effect of patient-controlled analgesia and conventional intramuscular opioid regimen in 68 patients undergoing lower abdominal or gynecological surgery. We also recorded the incidence of side effects. We checked visual analogue scale 4 hours interval for 30 cases managed by patient-controlled analgesia and 38 cases of conventional intramuscular opioid group managed by obstetrician. We maintained fentanyl $0.33{\mu}g/kg/hr$ and set self administrable bolus dose $5.0{\mu}g$(lockout interval: 15 min) in patient-controlled analgesia group. Conventional intramuscular bolus injection group were administered meperidine 50 mg for 4 hour interval. Mean visual analogue scale scores obtained by patient-controlled analgesia group and intramuscular bolus injection group were $2.49{\pm}0.67$ and $4.53{\pm}1.28$(p<0.05). Side effects such as; no significant incidence of respiratory depression, urinary retention, postural hypotension, nausea, vomiting and pruritus were developed by either group. These results suggest that patient-controlled analgesia was more effective method compared with conventional intraumuscular opioid injection regimen for post-operative pain management.

  • PDF

Studies on the Electrocadiogram in Non-human Primates Reared in Korea (國內 飼育 원숭이의 心電圖에 관한 硏究)

  • 서진석;서지민;이버들;송근호;이수진;김덕환;현병화;신남식
    • Journal of Veterinary Clinics
    • /
    • v.19 no.2
    • /
    • pp.132-138
    • /
    • 2002
  • Non-human primates are widely used for experimental animal and raised as companion animal in Korea. To establish the electrocadiogram (ECG) of non-human primates that are domestically raised, the author measured bipolar limb leads and augmented unipolar limb leads, after tiletamine/zolazepam (TZ) injection as sedative agents. The amplitudes of P,Q, R,S and T wave and duration time of P wave, QRS complex, PR and QT interval in each lead of ECG were evaluated in 7 non-human primates at 15 minutes after TZ injection, respectively. The amplitude of P wave in I, II,III, aVR, aVL and aVF leads revealed 0.06$\pm$ 0.05,0.14$\pm$ 0.05, 0.1 $\pm$ 0.05,-0.11 $\pm$ 0.06,-0.04$\pm$ 0.04 and 0.12$\pm$ 0.05 mV respectively. The amplitude of Q wave revealed -0.16$\pm$ 0.15, -0.23$\pm$ 0.18, -0.17$\pm$ 0.13, 0.16$\pm$0.13, 0.04$\pm$ 0.09 and -0.2$\pm$0.13 mV, respectively. The amplitude of R wave revealed 0.56$\pm$0.56, 1.24$\pm$ 0.67, 0.92$\pm$0.33, -0.37$\pm$ 1.14, -0.22$\pm$ 0.47 and 1.12 $\pm$ 0.47 mV, respectively. The amplitude of S wave revealed -0.02$\pm$ 0.08, -0.04$\pm$0.06, -0.06$\pm$0.04, 0.02$\pm$0.04, 0.04$\pm$0.09 and -0.04 $\pm$ 0.06 mV, respectively. The amplitude of T wave revealed -0.01 $\pm$ 0.15,-0.02$\pm$ 0.13, 0.01 $\pm$ 0.08, 0.02$\pm$ 0.12, 0.01 $\pm$ 0.11 and -0.03$\pm$ 0.09 mV, respectively. The duration time of P wave revealed 0.05 $\pm$ 0.01, 0.04$\pm$ 0.01, 0.05$\pm$ 0.02, 0.05 $\pm$ 0.02, 0.04$\pm$ 0.01 and 0.04$\pm$ 0.01 sec, respectively. The duration time of QRS complex revealed 0.05 $\pm$ 0.02,0.05$\pm$ 0.01, 0.05 $\pm$ 0.01, 0.04$\pm$ 0.01, 0.05$\pm$ 0.01 and 0.05 $\pm$ 0.01 sec, respectively. The duration time of PR interval revealed 0.08$\pm$ 0.01, 0.07$\pm$0.01,0.08$\pm$ 0.03, 0.08$\pm$0.01, 0.08$\pm$ 0.01 and 0.08$\pm$0.01 sec, respectively. The duration time of QT interval revealed 0.23$\pm$ 0.06, 0.22$\pm$ 0.05, 0.23 $\pm$ 0.06, 0.23$\pm$ 0.06, 0.24$\pm$ 0.05 and 0.22$\pm$ 0.02 sec, respectively. No significant changes were observed in e amplitude of P and T waves. The amplitude of QRS complex in ketamine group was higher than that of TZ group. However, no significant changes were observed in both intra-group and inter-group. There were no significant changes in the duration time of P wave, QRS complex and PR interval obtained from both groups. Also, the duration time of QT interval in TZ group was significantly longer at 30 min.(P< 0.05) an that of 10 minutes after injection. However, significant difference was not found between two groups. The mean cardiac electric axis in ketamine group tended to decrease until 30 min. after injection and then gradually increase. However, mean cardiac electric axis of TZ group was increased until 30 min. after injection and then decreased. But significant differences were not observed between groups. These results suggest that the ECG pattern after TZ injection to non-human primates reared in korea was established. It was also considered that the injection of ketamine and TZ didn't significantly affect on ECG pattern of the non-human primates.

Rock Permeability Estimation from Hydraulic Injection Tests in a Sealed Borehole Interval

  • Quach, Nghiep Q.;Jo, Yeonguk;Chang, Chandong
    • The Journal of Engineering Geology
    • /
    • v.28 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • We propose a borehole test technique to estimate permeability of rocks in borehole. The borehole tests are hydraulic injection tests such as leak-off test and hydraulic fracturing tests, which are originally conducted for stress or casing integrity assessment and not for permeability measurement. We use one-dimensional radial diffusion equation to interpret fluid injection test results in terms of permeability. We apply this technique to a leak-off test conducted at a depth of 700 m in a wellbore, where rock formation is mudstone. The estimated permeability is at an order of $10^{-16}m^2$, which is somewhat high but within the range reported for mudstones previously. Quantitative rick assessment suggests that an accurate measurement of open hole section length is important to improve reliability of results. More data may be needed to ensure the reliability of this technique. If validated, however, this technique can provide cost-effective estimation of in situ permeability without conducting independent permeability tests in borehole.

Application of Reliability Centered Maintenance Strategy to Safety Injection System for APR1400

  • Rezk, Osama;Jung, JaeCheon;Lee, YongKwan
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.12 no.1
    • /
    • pp.41-58
    • /
    • 2016
  • Reliability Centered Maintenance (RCM) introduces a systematic method and decision logic tree for utilizing previous operating experience focused on reliability and optimization of maintenance activities. In this paper RCM methodology is applied on safety injection system for APR-1400. Functional Failure Mode Effects and Criticality Analysis (FME&CA) are applied to evaluate the failure modes and the effect on the component, system and plant. Logic Tree Analysis (LTA) is used to determine the optimum maintenance tasks. The results show that increasing the condition based maintenance will reduce component failure and improve reliability and availability of the system. Also the extension of the surveillance test interval of Safety Injection Pumps (SIPs) would lead to an improved pump's availability, eliminate the unnecessary maintenance tasks and this will optimize maintenance activities.

Numerical Analysis of Cooling Channels for Injection Molding Cycle Time Improvement of Plastic Horn Cover for an Automobile (차량용 플라스틱 혼 커버의 사출성형 싸이클 타임 개선을 위한 냉각 채널의 수치해석 연구)

  • Han, Seong-Ryoel
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.5
    • /
    • pp.84-90
    • /
    • 2018
  • When producing a plastic horn cover for an automobile, since the interval between the ribs on the inner surface is narrow, conventional cooling channels cannot be applied and cooling of the mold is difficult. For this reason, the molding operation cannot be completed within a set cycle time. In this study, a conformal cooling channel was applied on the mold to solve the cooling problem. Injection molding simulation was carried out to confirm the effectiveness of the conformal cooling channel. In the analysis results, the mold temperature at the rib section decreased by 33%, and the mold temperature also decreased by 31%. This reduction in temperature allowed for molding within a set cycle time and demonstrated the effectiveness of the conformal cooling channel.

Development and mechanical properties of bagasse fiber reinforced composites

  • Cao, Yong;Goda, Koichi;Shibata, Shinichi
    • Advanced Composite Materials
    • /
    • v.16 no.4
    • /
    • pp.283-298
    • /
    • 2007
  • Environment-friendly composites reinforced with bagasse fiber (BF), a kind of natural fiber as the remains from squeezed sugarcane, were fabricated by injection molding and press molding. As appropriate matrices for injection molding and press molding, polypropylene (PP) and polycaprolactone-cornstarch (PCL-C) were selected, as a typical recyclable resin and biodegradable resin, respectively. The mechanical properties of BF/PP composites were investigated in view of fiber mass fraction and injection molding conditions. And the mechanical properties and the biodegradation of BF/PCL composites were also evaluated. In the case of injection molding, the flexural modulus increased with an increase in fiber mass fraction, and the mechanical properties decreased with an increase in cylinder temperature due to the thermal degradation of BF. The optimum conditions increasing the flexural properties and the impact strength were $90^{\circ}C$ mold temperature, 30 s injection interval, and in the range of 165 to $185^{\circ}C$ cylinder temperature. On the other hand, as to BF/PCL-C fully-green composites, both the flexural properties and the impact strength increased with an increase in fiber mass fraction. It is considered that the BF compressed during preparation could result in the enhancement in mechanical properties. The results of the biodegradability test showed the addition of BF caused the acceleration of weight loss, which increased further with increasing fiber content. This reveals that the addition and the quantities of BF could promote the biodegradation of fully-green composites.