• Title/Summary/Keyword: Initiating event

Search Result 59, Processing Time 0.027 seconds

Determination of Performance Indicator Thresholds Based on Typical PSA Results

  • Kang, Dae-Il;Kim, Kil-Yoo;Hwang, Mee-Jung;Sung, Key-Yong
    • Nuclear Engineering and Technology
    • /
    • v.36 no.6
    • /
    • pp.485-496
    • /
    • 2004
  • Typical probabilistic safety assessment (PSA) results were used to estimate the performance indicator (PI) thresholds of unplanned reactor scram (URS) and safety system unavailability (SSU) for Korean nuclear power plants (NPPs). The changes in core damage frequency (${\Delta}$CDFs) of $10^{-6}/yr$, $10^{-5}/yr$, and $10^{-4}/yr$ were adopted as the risk criteria in setting up the PI thresholds. The PI thresholds for the URS were estimated using information pertaining to the initiating event frequencies, the CDF, and the CDF contribution of each initiating event. The PI thresholds of the SSU were estimated using information on the unavailability, the Fussell-Vesely importance, and the CDF.

Safety Assessments for the IS(Iodine Sulfur) Process in a Hydrogen Production Facility (수소생산시설에서의 요오드-황 공정에 대한 안전성 평가연구)

  • Lee, Hyon-Woo;Jae, Moo-Sung;Cho, Nam-Chul;Yang, Jon-Eon;Lee, Won-Jae
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.3
    • /
    • pp.54-58
    • /
    • 2009
  • A substitute energy development has been required due to the exhaust of the fossil fuel and an environmental problem. Consequently, possible technologies producing hydrogen from water that does not release carbon is a very promising technology. Also, Iodine-Sulfur(IS) thermochemical water decomposition is one of the promising processes that are used to produce hydrogen efficiently using the high temperature gas-cooled reactor(HTGR) as an energy source that is possible to supply heat over 900$^{\circ}C$. In this study, to make a initiating events identification for the IS process, Master Logic Diagram(MLD) is used and 9 initiating events that cause a leakage of the chemical material are identified. Also, 6 events are identified among 9 initiating events above and are quantified using event tree.

A New Approach to Selection of Inspection Items using Risk Insight of Probabilistic Safety Assessment for Nuclear Power Plants

  • Park, Younwon;Kim, Hyungjin;Lim, Jihan;Choi, Seongsoo
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.14 no.2
    • /
    • pp.49-58
    • /
    • 2018
  • The regulatory periodic inspection program (PSI) conducted at every overhaul period is the most important process for confirming the safety of nuclear power plants. The PSI for operating nuclear power plants in Korea mainly consist of component level performance check that had been developed based on deterministic approach putting the same degree of importance to all the inspection items. This inspection methodology is likely to be effective for preoperational inspection. However, once the plant is put into service, the PSI must be focused on whether to minimize the risk of accident using defense-in-depth concept and risk insight. The incorporation of defense-in-depth concept and risk insight into the deterministic based safety inspection has not been well studied so far. In this study, two track approaches are proposed to make sure that core damage be avoided: one is to secure success path and the other to block the failure path in a specific event tree of PSA. The investigation shows how to select safety important components and how to set up inspection group to ensure that core damage would not occur for a given initiating event, which results in strengthening defense-in-depth level 3.

인간신뢰도분석에서의 인간행위 의존성 평가: 암모니아 저장시설의 누출사고 평가 예

  • 강대일;이윤환;진영호
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1998.11a
    • /
    • pp.219-224
    • /
    • 1998
  • 확률론적 안전성 평가(Probabilistic Safety Assessment PSA)나 정량적인 위험도 평가(Quantitative Risk Assessment: QRA)에서 인간신뢰도분석(human reliability analysis)은 인간행위를 기기처럼 생각하여 전체 시스템의 안전성에 중요한 초기사건(initiating event) 이전이나 초기사건 이후 또는 초기사건을 유발하는 인간행위를 파악하고 정량화하여, 확률론적 평가의 논리구조인 사건 및 고장수목(event tree 및 fault tree)이나 사고경위 단절집합 (accident sequence outsets)에 포함시키는 것이다. (중략)

  • PDF

Internal Event Level 1 Probabilistic Safety Assessment for Korea Research Reactor (국내 연구용원자로 전출력 내부사건 1단계 확률론적안전성평가)

  • Lee, Yoon-Hwan;Jang, Seung-Cheol
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.3
    • /
    • pp.66-73
    • /
    • 2021
  • This report documents the results of an at-power internal events Level 1 Probabilistic Safety Assessment (PSA) for a Korea research reactor (KRR). The aim of the study is to determine the accident sequences, construct an internal level 1 PSA model, and estimate the core damage frequency (CDF). The accident quantification is performed using the AIMS-PSA software version 1.2c along with a fault tree reliability evaluation expert (FTREX) quantification engine. The KRR PSA model is quantified using a cut-off value of 1.0E-15/yr to eliminate the non-effective minimal cut sets (MCSs). The final result indicates a point estimate of 4.55E-06/yr for the overall CDF attributable to internal initiating events in the core damage state for the KRR. Loss of Electric Power (LOEP) is the predominant contributor to the total CDF via a single initiating event (3.68E-6/yr), providing 80.9% of the CDF. The second largest contributor is the beam tube loss of coolant accident (LOCA), which accounts for 9.9% (4.49E-07/yr) of the CDF.

A Loss-of-RHR Event under the Various Plant Configurations in Low Power or Shutdown Conditions

  • Seul, Kwang-Won;Bang, Young-Seok;Lee, Sukho;Kim, Hho-Jung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.551-556
    • /
    • 1997
  • A present study addresses a loss-of-RHR event as an initiating event under specific low power or shutdown conditions. Two typical plant configurations, cold leg opening case with water-filled steam generators and pressurizer opening case with emptied steam generators, were evaluated using the RELAP5/ MOD3.2 code. The calculation was compared with the experiment conducted at ROSA-IV/LSTF in Japan. As a result, the code was capable of simulating the system transient behavior following the event. Especially, thermal hydraulic transport processes including non-condensable gas behavior were reasonably predicted with an appropriate time step and CPU time. However, there were some code deficiencies such as too large system mass errors and severe flow oscillations in core region.

  • PDF

Risk Analysis of Electrical Fire for Electric Power Installations by Event Tree Analysis (사건수목분석을 통한 수배전설비의 전기화재위험성 분석)

  • Park, Young Ho;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.16-21
    • /
    • 2016
  • The purpose of this paper is to conduct ETA on 15 components of power installations: the DS/LBS, LA, MOF, CT, PT, A/V meter, VCB, OCR, COS, PF, Transformer, Condenser(C), Grounding, Cable and Connector. To achieve that, power installations work flow and its components are categorized. Based on performance, human, environmental, management, and safety, this paper drew Initiation events (IE) and End states (ES). ETA is applied to the main functions of each component, and the end states that may occur in one initiation event are suggested. In addition, detailed classification was performed to induce various end states on the basis of the suggested initiation events. If the suggested IEs and ESs are applied on the basis of power installations event cases, it is expected to prevent the same kinds of accident and operate power installations safely.