• Title/Summary/Keyword: Initial operation characteristics

Search Result 281, Processing Time 0.024 seconds

Study of Driving and Thermal Stability of Anode-type Ion Beam Source by Charge Repulsion Mechanism

  • Huh, Yunsung;Hwang, Yunseok;Kim, Jeha
    • Applied Science and Convergence Technology
    • /
    • v.27 no.3
    • /
    • pp.47-51
    • /
    • 2018
  • We fabricated an anode-type ion beam source and studied its driving characteristics of the initial extraction of ions using two driving mechanisms: a diffusion phenomenon and a charge repulsion phenomenon. For specimen exposed to the ion beam in two methods, the surface impurity element was investigated by using X-ray photoelectron spectroscopy. Upon Ar gas injection for plasma generation the ion beam source was operated for 48 hours. We found a Fe 2p peak 5.4 at. % in the initial ions by the diffusion mechanism while no indication of Fe in the ions released in the charge repulsion mechanism. As for a long operation of 200 min, the temperature of ion beam sources was measured to increase at the rate of ${\sim}0.1^{\circ}C/min$ and kept at the initial value of $27^{\circ}C$ for driving by diffusion and charge repulsion mechanism, respectively. In this study, we confirmed that the ion beam source driven by the charge repulsion mechanism was very efficient for a long operation as proved by little electrode damage and thermal stability.

A Study on the Removal Characteristics of Indoor Air Pollutants using the Air Cleaning System (실공간에서 공기정화시스템을 이용한 실내 오염 입자 제거 특성에 관한 연구)

  • Koo, Jeong-Hwan;Kim, Seong-Chan;Kim, Jang-Woo;Lee, Ju-Yong;Lee, Jae-Keun;Kang, Tae-Wook;Lee, Kam-Gyu
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.532-537
    • /
    • 2000
  • The purpose of this study is to determine the performance of a commercial air cleaner in removing tobacco smoke indoors. Following injection of tobacco smoke in a room, decay rates for particle concentrations were obtained far mass concentration at each point. The size distribution of the tobacco smoke particles was approximately $1.266{\mu}m$ in mass median diameter with a geometric standard deviation of 1.313. The air cleaner consisted of an electrostatic filtration unit and a fan operated at a flow rate of 5.98 CMM. The collection efficiency for $>1\;{\mu}m$ was more than 99%. Without air cleaner operation, tobacco smoke concentration ratio in room decreased to 30% of initial values within 30 minutes and with air cleaner operation, decreased to 90% of initial values in the test chamber, volume $51.27\;m^3$. Without air cleaner operation, tobacco smoke concentration ratio in room decreased to 10% of initial values within 30 minutes and with air cleaner operation, decreased to 30-70% of initial values in the test chamber, volume $149.2\;m^3$.

  • PDF

Operation Characteristics of a Small Single-phase Written-pole Motor in Home Appliance (가전기기용 소형 단상 Written Pole Motor의 운전특성)

  • Park, Seong-Cheol;Lee, Won-Yong;Yu, Byung-Hun;Kim, Dae-Kyong;Shin, Duck-Shick;Kim, Byung-Taek
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.2
    • /
    • pp.311-317
    • /
    • 2010
  • This paper deals with operation characteristics of a written-pole motor (WPM), having that of a permanent magnet (PM) synchronous motor and induction motor at once. The WPM also has a magnet layer on the surface of the rotor and the exciter pole that is a device to make the magnet layer magnetized during the operation. This study, introducing a fundamental structure and operation characteristics of a single-phase WPM, proposes a initial design method. With those ground, a 130W, single-phase WPM that is designed for a home appliance is presented and verified with a performance through the experiment.

A Study on Characteristics of Flux-offset-type Fault Current limiter according to Initial fault current

  • Jung, Byungik;Hwang, Junwon;Choi, Hyosang
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.7 no.2
    • /
    • pp.117-122
    • /
    • 2015
  • Our research team proposed a flux-offset type fault current limiter as a new limiter. The flux-offset type fault current limiter uses a fault current limit technology based on the flux offset principle of the primary and secondary windings of a transformer. Stable fault current limit characteristics were achieved through a preliminary study. However, it was discovered that the initial fault current was not limited. Therefore, in this paper, a high-speed interrupter and a superconducting element were separately applied to the secondary winding of the flux-offset type fault current limiter and the operating characteristics were comparatively analyzed. In the experiment, when the superconducting element was applied to the secondary winding of the transformer, the initial fault current was limited while the limitation in the operation time was further shortened.

Operation characteristics of a fault current limiter by high speed interrupter and a superconducting element

  • Im, I.G.;Jung, I.S.;Choi, H.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.3
    • /
    • pp.10-14
    • /
    • 2014
  • Due to continuous increase of electric power consumption, couple of resolutions for improving accuracy in power system like line separation are being studied. The increase of the power demand can cause problems such as supply difficulties of the electricity and broadband outages, failure, etc. When a fault occurs in the power system, a fault current also increases. Fault current creates problems like reduction of lifespan and failure on the power system. In order to resolve these problems, the reduction of initial fault current using the characteristics of superconducting element was applied to fault current limiter. We applied the system to high speed fault current limiter. We found that the superconducting element effectively reduced initial fault current and the fault current was limited by changing operation of high speed interrupter.

A Study on the Control System of Permanent Magnet Linear Synchronous Motor Applied to the Z-axis Operation Structure (Z축 운전구조를 갖는 선형 영구자석형 동기 전동기 운전제어에 관한 연구)

  • Choi, Chul;Lee, Jin-Ha;Park, Han-Woong;Kim, Chul-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.142-149
    • /
    • 2004
  • PMLSM(Permanent Magnet linear Synchronous Motor) has widely applied to industrial automations, machine tools and semiconductor equipments due to the merit on the reduction of noise, vibration and the superior dynamic characteristics in comparison to the conventional method, which uses mechanical transfer equipments. Especially, in the case of applying to Z-axis operation structure, control system needs the method of an initial angle setting and the improvement of up/down operation characteristics. This paper proposes an initial angle setting algorithm and a variable gain schedule using real speed and moving direction to improve up/down operation characteristics. The effectiveness of proposed algorithms Is demonstrated by comparing to a conventional gain system via 4-point absolute positions profile with each velocity, acceleration and deceleration.

Estimation of FDS Prediction Performance on the Operation of Water-Mist (미세물분무 작동에 대한 FDS 예측 성능 평가)

  • Ko, Gwon Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.8
    • /
    • pp.4809-4814
    • /
    • 2014
  • The aim of the present study was to estimate the prediction performance of a FDS (Fire Dynamic Simulator) to simulate the fire behaviors and suppression characteristics by operating a water-mist. Rosin-Rammler/log-normal distribution function was used to determine the initial droplet distribution of water-mist and the effects of its model constant were considered. In addition, the simulation models were validated by a comparison of the predicted fire suppression characteristics with water-mist injection pressures to the previous experiments, and the thermal flow behaviors and gaseous concentration variations were analyzed. The results showed that water-mists with the same mean diameter were affected by the characteristics of the droplet size distribution, which have different size and velocity distributions at the downstream location. The fire simulations conducted in this study determine the initial droplet size distribution tuned to the base of the spray characteristics measured by previous experiments. The simulation results showed good agreement with the previous measurements for temperature variations and fire suppression characteristics. In addition, it was confirmed that the FDS simulation with a water-mist operation supplies useful details on estimations of the thermal flow fields and gaseous concentration under water mist operation conditions.

Effects of blade configuration and solidity on starting torque of Darrieus wind turbine

  • Roh, Sung-Cheoul;Kang, Seung-Hee
    • Wind and Structures
    • /
    • v.32 no.2
    • /
    • pp.169-177
    • /
    • 2021
  • This study investigates the effects of blade configuration and solidity of Darrieus wind turbine on the starting torque characteristics. Generally, the configuration of Darrieus wind turbine is divided into Troposkien, parabola, Catenary, Sandia, modified-parabola and straight types. A numerical analysis has been carried out using Multiple Stream Tube (MST) method to investigate the effect of blade configuration and solidity of Darrieus wind turbine on the starting torque under the initial low range of rotational speed. The simulation results show that the starting torque of Darrieus wind turbine varies considerably depending on the blade configuration. The initial starting torque was larger with Troposkien, Parabola, Catenary, and Sandia configurations than with modified parabola or straight types. The increase in solidity with increasing number of blades raised the starting torque and improved the dynamic stability during the initial operational speed of Darrieus wind turbine. Additionally, these torque results represent basic data for fluid-structure interaction (FSI) simulation of the steady-dynamic operation of the turbine.

Characteristics of Lactose Hydrolysis by Immobilized β-Galactosidase on Chitosan Bead (Chitosan 담체에 고정화된 β-galactosidase에 의한 유당 분해 특성)

  • Kang, Byung-Chul
    • Journal of Life Science
    • /
    • v.21 no.1
    • /
    • pp.127-133
    • /
    • 2011
  • ${\beta}$-Galactosidase was immobilized on chitosan bead by covalent bonding using glutaraldehyde. The characteristics of the immobilized enzyme were investigated. Maximum immobilization yield of 75% was obtained on chitosan bead. Optimum pH and temperature for the immobilized enzyme was 7.0 and $50^{\circ}C$, respectively. The immobilized enzyme showed a broader range of pH and temperature compared to a free one. A mathematical model for the operation of the immobilized enzyme in a packed-bed reactor was established and solved numerically. Under different inlet lactose concentrations and feed flow rate conditions, lactose conversion was measured in a packed-bed reactor. The experimental results of continuous operation in a packed-bed reactor were compared to theoretic results using Michaelis-Menten kinetics with competitive product inhibition and external mass transfer resistance. The model predicted the experimental data with errors less than 5%. Process optimization of continuous operation in a packed-bed reactor was also conducted. In a recirculation packed-bed operation, conversion of lactose was 97% in 3 hours. In a continuous packed-bed operation, the effect of flow rate and initial lactose concentration was investigated. Increasing flow rates and initial lactose concentration decreased the conversion of substrate.

The Effects of a Trauma Team Approach on the Management of Open Extremity Fractures in Polytrauma Patients: A Retrospective Comparative Study

  • Sakong, Seungyeob;Lim, Eic Ju;Cho, Jun-Min;Choi, Nak-Jun;Cho, Jae-Woo;Oh, Jong-Keon
    • Journal of Trauma and Injury
    • /
    • v.34 no.2
    • /
    • pp.105-111
    • /
    • 2021
  • Purpose: Open extremity fractures require prompt antibiotic medication and initial debridement surgery to reduce the infection rate and restore functional stabilization. We aimed to report the effects and positive outcomes of a trauma team approach on the management of open extremity fractures in polytrauma patients. Methods: This retrospective review included all polytrauma patients with open extremity fractures admitted between March 2009 and December 2019. Patients were divided into two groups according to whether they were treated before or after the implementation of the trauma team approach (March 2014). We analyzed the outcomes in each group with respect to the time interval until the doctor's arrival, total length of stay in the emergency department, the time interval until initial antibiotic treatment and operation, whether the initial operation was performed within 24 hours, and the rate of deep infections. Results: A total of 123 patients met the inclusion criteria. There were no statistically significant differences in demographic characteristics. The time interval until the doctor's arrival (64.12±49.2 minutes vs. 19.82±15.23 minutes; p=0.035) and initial antibiotic treatment (115.47±72.12 minutes vs. 48.78±30.12 minutes; p=0.023) significantly improved after implementing the trauma team approach. The union rate was not significantly different. However, the time interval until initial debridement, opportunity for initial debridement within 24 hours, and the rate of deep infections demonstrated better results. Conclusions: The reduced time interval until initial antibiotic treatment and debridement could be attributed to the positive effect of the trauma team approach on the management of open extremity fractures in polytrauma patients.