• 제목/요약/키워드: Initial firing angle

검색결과 7건 처리시간 0.025초

Initial Firing Angle Control of Parallel Multi-Pulse Thyristor Dual Converter for Urban Railway Power Substations

  • Kim, Sung-An;Han, Sung-Wo;Cho, Yun-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.674-682
    • /
    • 2017
  • This paper presents an optimal initial firing angle control based on the energy consumption and regenerative energy of a parallel multi-pulse thyristor dual converter for urban railway power substations. To prevent short circuiting the thyristor dual converter, a hysteresis band for maintaining a zero-current discontinuous section (ZCDS) is essential during mode changes. During conversion from the ZCDS to forward or reverse mode, the DC trolley voltage can be stabilized by selecting the optimal initial firing angle without an overshoot and slow response. However, the optimal initial firing angle is different depending on the line impedance of each converter. Therefore, the control algorithm for tracking the optimal initial firing angle is proposed to eliminate the overshoot and slow response of DC trolley voltage. Simulations and experiments show that the proposed algorithm yields the fastest DC voltage control performance in the transient state by tracking the optimal firing angle.

교류 입력 전압 변동에 따른 사이리스터 듀얼 컨버터의 출력 특성 개선을 위한 알고리즘 개발 (Algorithm Development for Improving Output Characteristics of Thyristor Dual Converter with AC Input Voltage Variation)

  • 김성안;한성우;조윤현
    • 전기학회논문지
    • /
    • 제66권9호
    • /
    • pp.1437-1443
    • /
    • 2017
  • Electric energy is consumed or regenerated according to an operation of electric rail cars in urban railway power substations. A thyristor dual converter system is used to deal with the electric energy. Since the AC input voltage of power substations is $22.9kV{\pm}10%$, the magnitude of the AC voltage fluctuates according to load conditions, so the secondary side voltage of the DDY transformer also fluctuates. In the thyristor dual converter, the response characteristics of the DC output voltage and the DC output current are changed based on an initial firing angle in the cross mode conversion between the forward mode and the reverse mode. Therefore, this paper proposes the initial firing angle tracking algorithm considering fluctuation of the AC input voltage. The effectiveness of the proposed algorithm is verified by a simulation compared with the conventional algorithm.

주퇴력 저감을 위한 연식 주퇴 메커니즘의 매개변수에 관한 연구 (A Study on Parameters of Soft Recoil Mechanism for Reduction of Recoil Force)

  • 양태호;이영신;이규섭;전상배;강국정
    • 대한기계학회논문집A
    • /
    • 제36권7호
    • /
    • pp.823-828
    • /
    • 2012
  • 연식주퇴 메커니즘은 전방 운동량으로 주퇴력을 감소시키는 메커니즘이다. 연식주퇴 메커니즘에 영향을 미치는 매개변수는 사격 각도, 복좌기의 초기 압력, 발사위치등과 같이 다양하게 존재한다. 이런 매개변수들은 연식주퇴 메커니즘에서 전방 운동량을 결정짓는 요소가 된다. 연식주퇴 메커니즘의 설계를 위해 몇 가지 적당한 조건들을 고려하여 전방 운동량에 영향을 미치는 매개변수들에 대해 연구하였다. 여러 가지 매개변수들 중에서 복좌기의 초기 압력과 사격 위치가 전방 운동량에 영향을 미치는 중요한 요소로 확인하였다. 복좌기의 초기 압력이 180 일 때, 주퇴력이 가장 낮은 값을 가진다.

더블 컨버터의 초기 점호각에 따른 출력 특성 대한 연구 (A Study on Output Characteristics According to Initial Firing Angle of Double Converter)

  • 장춘석;한성우;김성안;한갑진;조윤현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.978-979
    • /
    • 2015
  • 본 논문에서는 부하에 따라 직류 가선전압의 제어가 가능하며 회생에너지를 재사용 할 수 있는 사이리스터 더블컨버터를 제안하며, 안정적인 모드 전환을 위하여 모드 전환시 초기 점호각에 따른 직류 전압의 특성을 시뮬레이션을 통하여 증명하였다.

  • PDF

The Characteristics on the Change of Cerebral Cortex using Alternating Current Power Application for Transcranial Magnetic Stimulation

  • Kim, Whi-Young
    • Journal of Magnetics
    • /
    • 제19권2호
    • /
    • pp.197-204
    • /
    • 2014
  • A transcranial magnetic stimulation device is a complicated appliance that employs a switching power device designed for discharging and charging a capacitor to more than 1 kV. For a simple transcranial magnetic stimulation device, this study used commercial power and controlled the firing angle using a Triac power device. AC 220V 60 Hz, the power device was used directly on the tanscranial magnetic stimulation device. The power supply device does not require a current limiting resistance in the rectifying device, energy storage capacitor or discharge circuit. To control the output power of the tanscranial magnetic stimulation device, the pulse repetition rate was regulated at 60 Hz. The change trigger of the Triac gate could be varied from $45^{\circ}$ to $135^{\circ}$. The AVR 182 (Zero Cross Detector) Chip and AVR one chip microprocessor could control the gate signal of the Triac precisely. The stimulation frequency of 50 Hz could be implemented when the initial charging voltage Vi was 1,000 V. The amplitude, pulse duration, frequency stimulation, train duration and power consumption was 0.1-2.2T, $250{\sim}300{\mu}s$, 0.1-60 Hz, 1-100 Sec and < 1 kW, respectively. Based on the results of this study, TMS can be an effective method of treating dysfunction and improving function of brain cells in brain damage caused by ischemia.

유도형 코일건의 에너지 및 속도특성 해석 (Energy and Speed Characteristics of Induction Coil-Gun)

  • 장성만;김석환;한송엽;정현교
    • 한국자기학회지
    • /
    • 제2권1호
    • /
    • pp.69-74
    • /
    • 1992
  • 본 논문에서는 커패시터로 구동되는 공진 유도형 코일건의 속도 및 에너지 전달 특성을 해석했다. 유도형 코일건은 설치가 자유롭고, 기계적 마모가 적고, 반복사용이 가능하며, 전달되는 힘이 피투사체의 표면에 고르게 분포한다는 장점을 가지고 있다. 특성해석을 위해 등가회로를 구성 하여 회로방정식과 운동방정식을 유도하고, 이 방정식들을 Runge-Kutta 방법을 사용하여 수치적으 로 풀었다. 그리고 구동회로의 공진주파수 및 커패시터의 충전전압에 대한 에너지 전달율을 구했으 며, 또한 피투사체의 초기위치와 도전율, 구동회로의 점호각, 충전전압 및 구동코일의 저항 각각에 대한 피투사체의 포구속도의 변화를 구하였다.

  • PDF

도시철도의 직류전력 공급을 위한 사이리스터를 사용한 병렬 듀얼 컨버터의 순차적 모드 전환 제어 알고리즘에 대한 연구 (A Studies for Sequential Mode Change Control Algorithm of the Parallel Dual Converter of Using Thyristor for Supplying the Urban Railway DC Power)

  • 한성우;김성안;조윤현;변기식
    • 전기학회논문지
    • /
    • 제65권3호
    • /
    • pp.511-519
    • /
    • 2016
  • This paper is proposed control algorithm for the using thyristor of the parallel dual converter for Urban railway power supply in order to return the regenerative power generated by regenerative braking in urban railway train. Conventional control algorithm of Thyristor dual converter for urban railway power supply has voltage variation within a control range of hysteresis band. The purposed control algorithm of the parallel thyristor dual converter is to maintain a constant voltage without voltage variation in accordance with variable load through the Sequential mode change. And the control algorithm need calculating optimum initial firing angle to consider magnitude of the load current slope. For this purpose, Proposed algorithm for sequential conversion mode of the dual converter was verified by applying for the simulation.