• Title/Summary/Keyword: Initial Temperature

Search Result 4,256, Processing Time 0.035 seconds

An Experimental Study on the Characteristics of Compressive Strength in Cement Mortar under High Temperature conditions in an Early Age (초기 고온이력이 시멘트 모르터의 강도발현에 미치는 영향에 관한 연구)

  • Kim Young-Joo;Choi Maeng-Ki;Gong Min-Ho;Park Hee-Gon;Kim Kwang-Ki;Jung Sang-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.45-48
    • /
    • 2005
  • This study is basic experiment for estimating influence of strength by curing temperature of concrete's heat of hydration and estimate relationship of compressive strength development by initial curing temperature factor, and then asume temperature factor which influence compressive strength development and for showing basic document of qualify control. According to the result of cement mortar by the curing temperature factor high-curing temperature shows high strength on 3 day compare with low curing-temperature, shows higher strength than the piece of high curing temperature.

  • PDF

Far-Infrared Ray Drying Characteristics of Rough Rice (I) -Thin layer drying equation- (벼의 원적외선 건조특성 (I) -박층건조방정식-)

  • Keum, D. H.;Kim, H.;Hong, S. J.
    • Journal of Biosystems Engineering
    • /
    • v.27 no.1
    • /
    • pp.45-50
    • /
    • 2002
  • This study was performed to develop thin layer drying equations fur short grain rough rice using far-infrared ray. Thin layer drying tests was conducted at four far-infrared ray temperature levels of 30, 40, 50, 60$^{\circ}C$ and two initial moisture content levels of 20.7, 26.2%(w.b.). The measured moisture ratios were fitted to Lewis and Page drying models by stepwise multiple regression analysis. Half response time of drying was affected by both drying temperature and initial moisture content at drying temperature of below 40$^{\circ}C$, but at above 40$^{\circ}C$ was mainly affected by drying temperature. Experimental constant(k) in Lewis model was a function of drying temperature, but K and N in Page model were function of drying temperature and initial moisture content. Moisture ratios predicted by two drying models agreed well with experimental values. But in the actual range of drying temperature above 30$^{\circ}C$ Page model was more suitable for predicting of drying rates.

Nonlinear dynamic response of axially moving GPLRMF plates with initial geometric imperfection in thermal environment under low-velocity impact

  • G.L. She;J.P. Song
    • Structural Engineering and Mechanics
    • /
    • v.90 no.4
    • /
    • pp.357-370
    • /
    • 2024
  • Due to the fact that the mechanism of the effects of temperature and initial geometric imperfection on low-velocity impact problem of axially moving plates is not yet clear, the present paper is to fill the gap. In the present paper, the nonlinear dynamic behavior of axially moving imperfect graphene platelet reinforced metal foams (GPLRMF) plates subjected to lowvelocity impact in thermal environment is analyzed. The equivalent physical parameters of GPLRMF plates are estimated based on the Halpin-Tsai equation and the mixing rule. Combining Kirchhoff plate theory and the modified nonlinear Hertz contact theory, the nonlinear governing equations of GPLRMF plates are derived. Under the condition of simply supported boundary, the nonlinear control equation is discretized with the help of Gallekin method. The correctness of the proposed model is verified by comparison with the existing results. Finally, the time history curves of contact force and transverse center displacement are obtained by using the fourth order Runge-Kutta method. Through detailed parameter research, the effects of graphene platelet (GPL) distribution mode, foam distribution mode, GPL weight fraction, foam coefficient, axial moving speed, prestressing force, temperature changes, damping coefficient, initial geometric defect, radius and initial velocity of the impactor on the nonlinear impact problem are explored. The results indicate that temperature changes and initial geometric imperfections have significant impacts.

Hysteresis on Boiling Heat Transfer at Low Temperature on Enhanced Tubes in a Flooded Evaporator (만액식 증발기의 열전달 촉진관에서 저온 비등열전달의 이력현상 특성)

  • 윤현필;박종익;정진희;강용태
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.4
    • /
    • pp.254-260
    • /
    • 2003
  • The boiling characteristics for R134a are studied to clarify the hysteresis at low temperature on enhanced tubes of a flooded evaporator. Initial boiling conditions, refrigerant temperature, and inlet temperature of the chilled water are considered as the key parameters of the experiments. Unlike previous studies of the boiling heat transfer with uniform heat flux and uniform wall temperature, the wall temperature was varied along the tube. In, this study, it was found that the hysteresis of the temperature overshoot (705) at the onset of nucleate boiling initially at the inlet section of the tube. It is also concluded that the abnormal operation can be avoided during the low temperature boiling if the refrigeration system is started with LMTD larger than $3.4^{\circ}C$ at initial stage and larger than $1.0^{\circ}C$ at normal stage.

An Experimental Study on Low-Temperature Behavior of Stratified Fluids in a Square Cavity with Upper Cooling Surface (상부에 냉각면이 있는 정방형내 이종유체의 저온거동에 관한 실험적 연구)

  • Lee, D.S.;Kim, B.C.
    • Solar Energy
    • /
    • v.20 no.1
    • /
    • pp.55-62
    • /
    • 2000
  • An experimental study on the stratified fluids with water and silicon oil of same volume in the cavity with upper cooling surface was carried out to investigate the flow characteristics, heat transfer through the interface of fluids, and the applications of thermal behaviors in a square cavity. The experiments were performed with variation of initial temperature and cooling surface temperature. The temperature drop of oil was faster than that of water and freezing was initiated from the interface of oil and water and propagated downward. For the water above $4^{\circ}C$, the cooling rate was faster than that below $4^{\circ}C$ and showed almost same temperature distribution but for the water that of below $4^{\circ}C$, it showed the stable stratified temperature distribution. The lower the initial temperature and the higher the cooling surface temperature was, the longer the supercooling duration.

  • PDF

The Physical Properties of Filling Batt Using Polyester Yarn (Polyester사를 이용한 충전용 솜사의 물성)

  • Park, Myung-Soo
    • Fashion & Textile Research Journal
    • /
    • v.9 no.3
    • /
    • pp.347-350
    • /
    • 2007
  • To analyse basic properties for making packing batt according to doubling condition, packing batt yarn, of $300^D$, $900^D$, $3600^D$ made from DTY yarn $150^D$/48 were produced from KTDI. The results are as follows: The birefringence of the sample yarn increased with increasing the annealing temperature and denier. The initial modulus of the sample yarn decreased with increasing the annealing temperature and denier. The higher than annealing temperature of $160^{\circ}C$, initial modulus of the sample are equilibrated. The strain recovery ratio of samples decreased with increasing the annealing temperature and denier. The lower than annealing temperature of $140^{\circ}C$, strain recovery ratio of the sample are decreased Where the $900^D$, $3600^D$ yarns are at $100^{\circ}C$ the specific bending rigidity value obtained is 0.65kgf/d but the twisted yarn (3,600) obtained 0.006 ($gfcm^2/tex^2$). However, where the heat temperature is $160^{\circ}C$, specific bending rigidity value obtained 0.003($gfcm^2/tex^2$).

Viscoelastic Properties of Fruit Flesh(I) - Stress Relaxation Behavior - (과실(果實)의 점탄성(粘彈性) 특성(特性)(I) - 응력이완거동(應力弛緩擧動) -)

  • Kim, M.S.;Park, J.M.;Choi, D.S.
    • Journal of Biosystems Engineering
    • /
    • v.17 no.3
    • /
    • pp.260-271
    • /
    • 1992
  • Fruits are generally subjected to mechanical forces during harvesting, handling, and transportation that may cause damage in the form of bruises, punctures, and cracks. In order to prevent damage, and insure better quality fruits for consumers, it is very essential to study physical properties of these materials. The studies were conducted to examine the effect of storage period, storage condition, and other factors, such as loading rate and initial strain, on the stress relaxation behavior of the fruit flesh, and develop nonlinear viscoelastic models to represent its stress relaxation behavior. The following results were obtained from the study : 1. Since the viscoelastic behavior of the fruits flesh was nonlinear, the behavior was satisfactorily modelled as follows ; $${\delta}({\varepsilon},\;t)={\varepsilon}^A[B\;{\exp}(-Ct)+D\;{\exp}(-Ft)+G(-Ht)]$$ But, for the every strain applied, the stress relaxation behavior of the fruit flesh, such as apple and pear, could be well described by the Generalized Maxwell model, respectively. 2. The effect of loading rate on the stress relaxation behavior was remarkable. The higher loading rate resulted in the higher initial stress, and the faster stress relaxation. 3. The higher initial strain resulted in the higher initial stress, and stress relaxed at the large initial strain was also much higher than at the small initial strain. 4. Stress relaxation rate and quantity stored in the fruits at the low temperature storage were much higher than those at the normal temperature storage in the same storage period. Also, in all fruits tested, the longer storage period was the more relaxation rate and quantity were shown. These trends in the normal temperature condition was the more significant than in the low temperature condition.

  • PDF

Analysis of Soil Thermal Conductivities, Borehole Thermal Resistances and Initial Soil Temperature with In-Situ Testing in South Korea (현지 측정에 의한 남한지역의 지중유효열전도도, 보어홀 전열저항 및 초기온도 분석)

  • Ro, Jeong-Geun;Yon, Kwangseok;Song, Heon
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.5
    • /
    • pp.68-74
    • /
    • 2012
  • Investigation of the effective soil thermal conductivity($k$) is the first step in designing the ground loop heat exchanger(borehole) of a geothermal heat pump system. Another important factor is the borehole thermal resistance($R_b$). Thermal response tests offer a good method to determine the ground thermal properties for the total heat transport in the ground. The first step is measured for initial soil temperature. This is done by supplying a only pump power into a borehole heat exchanger. They need to supply into water unload heat power more than 30 minutes. In this study, the initial soil temperature was found to analysis $14.1{\sim}16.0^{\circ}C$,the ratio was 68.7% represented. In this case of $k$, was 2.1~3.0 $W/m{\cdot}k$, $R_b$ was 0.11~0.20 $m{\cdot}K/W$. In this work, it is also shown that the distribution of a soil thermal conductivity and borehole thermal resistance were on the influence of initial soil temperature. And soil thermal conductivity was related with factors of equation by linear least square method, borehole thermal resistance was on the influence of composite factors.

The Analysis of Temperature on Superconducting Parallel Bifilar Winding (초전도 병렬 무유도권선의 온도 해석)

  • Oh, Yun-Sang;Lee, Sang-Jin;Bae, Joon-Han;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.134-136
    • /
    • 1995
  • A superconducting parallel bifilar winding shows the phenomenon which is known as 'fast quench'. We analyzed the temperature characteristics on the winding by computer simulation, and confirmed theses by experiment. The temperature of the quenched point rose gradually as the source voltage was increased. The temperature changed radically as first, but had a gentle slope after a few milliseconds. As the source voltage was large, the initial quenched length also increased. The points in this quenched length showed almost the same temperature. but the points where initial quench had not occurred showed radical temperature gradient. We could observe that the temperature of the whole wire increased simultaneously as the fast quench occurred on the superconducting parallel bifilar winding, because a number of quenched points in that wire appeared at the same time.

  • PDF

Changes of Myocardial Temperature Following Infusion of Cold Cardioplegic Solution in Open Heart Surgery (개심술에서 냉각 심정지액 주입에 따른 심근온도의 변화)

  • 임승우
    • Journal of Chest Surgery
    • /
    • v.24 no.4
    • /
    • pp.345-351
    • /
    • 1991
  • The myocardial temperature was monitored in 19 patients of open heart surgery using the Shiley myocardial temperature probe in Department of Thoracic and Cardiovascular Surgery, Yeungnam University Hospital. The myocardial temperature were measured time-wise: initial and 15 minutes following the infusion of the cardioplegic solution into the aortic root and upon reinfusion, which is 30 minutes apart from the initial. The measurements were made in the anterior wall of the right ventricle, the posterior wall of the left ventricle and the interventricular septum. Immediately after initial infusion, the temperature of the right ventricle[10.7 $\pm$4.3oC] was the lowest and that of the left ventricle[12.9$\pm$3.9 oC] the highest in the mean values among all 19 patients. However, no significant differences were noted among the different regions. At 15 minutes after infusion, the lowest temperature was in the right ventricle[17.5$\pm$5.1 oC], followed by interventricular septum[17.9$\pm$2.9 oC], and left ventricle[21.4$\pm$2.5 oC]. At 30 minutes after infusion, the lowest temperature was measured in the interventricular septum[13.6$\pm$2.7 oC ], followed by right ventricle[13.8$\pm$4.0 oC] and left ventricle[14.5$\pm$4.5 oC ]. Evaluating changes of myocardial temperature according to postinfusion time, the temperature at 15 minutes after infusion showed significant increase as compared with that immediately after the infusion in all three regions[p<0.05] and the temperature at 30 minutes after infusion showed significant decrease as compared with that at 15 minutes after the infusion in the left ventricle and the interventricular septum[p<0.05]. The left ventricle was rewarmed most rapidly and its temperature the highest in the mean values, Accordingly, the maintenance of optimal hypothermia of the left ventricle indicated a very careful factor in myocardial protection.

  • PDF