• Title/Summary/Keyword: Inhomogeneous Intensity

Search Result 34, Processing Time 0.019 seconds

MR Imaging Findings of Uterine Cervical Adenocarcinoma (자궁경부 선암종의 자기공명영상 소견)

  • 김종철
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.113-119
    • /
    • 1998
  • Purpose : Because adenocarcinomas of the uterine cervix have lower 5-year survival rate than squamous cell carcinomas due to early lymph node metastasis and local extension, scrutiny of lymph node metastasis and local extension by radiologic examination is necessary in case of clinically diagnosed or suspected adenocarcinomas. The purpose of this study is to evaluate whether there are specific findings of these tumors, compared with squamous cell carcinomas, through the analysis of magnetic resonance (MR) imaging findings. Materials and Methods : Of 21 pathologically proven cervical adenocarcinomas, MR imaging findings of 18 tumors (histologic staging : two Ib, four IIa, two IIb, one IIIa, and one IIIb) were retrospectively analyzed and compared with those of 40 wquamous cell carcinoma in consecutive patients as a control group. T1-wetighted and fast spin echo T2-weighted images were obtained on the axial and sagittal planes, using a 1.5-T MR scanner. The largest diameter, location, signal intensity and degree of contrast enhancement contour, shape and longitudinal extent of the tumor and associated findings on MR image were analyzed. Results : The largest diameters of cervical adenocarcinomas ranged from 0.8 to 4.1 cm(mean, 2.2 cm). Of 18 adenocarcinomas, nine were of endocervical type. All adenocarcinomas were isointense to surrounding cervical stroma on T1-weighted images and hyperintense(homogeneous in ten, inhomogeneous in eight) on fast spin echo T2-weighted images. Adenocarcinomas enhanced on contrast study in all patients (homogeneous in six, inhomogeneous in 12 with hyperintese enhnacing rim in two). Eight adenocarcinomas had smooth contours and ten had irregular ones. The shape of adenocarcinoma was irregular in eight patients, barrel shape in six, papillary/polypod in three, and nodular in one. All adenocarcinomas involved lower half of the uterine cervix and six tumors extended up to the upper half. Pelvic lymph nodes of more than 1.5cm in diameter in two adenocarcinomas pateints and no detectable small pelvic lymph nodes on MR imaging in one patient were pathologically positive. Hydrometra was associated in two adenocarcinomas patients, and hematometra in one patient. Compared with squamous cell carcinomas, more frequent MR findings of endocervical type and barrel shape in cervical adenocarcinomas were statistically significant. Conclusion : Cervical adenocarcinomas had more frequent MR findings of endocervical type and barrel shape, compared with wquamous cell carcinomas. Adenocarcinoma of the uterine cervix may be suspected on MR imaging, when a cervical carcinoma is of barrel shape along the endocervical canal and tends to involve lymth nodes in earlier stages.

  • PDF

Comparison of Intensity Modulated Radiation Therapy Dose Calculations with a PBC and AAA Algorithms in the Lung Cancer (폐암의 세기조절방사선치료에서 PBC 알고리즘과 AAA 알고리즘의 비교연구)

  • Oh, Se-An;Kang, Min-Kyu;Yea, Ji-Woon;Kim, Sung-Hoon;Kim, Ki-Hwan;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.48-53
    • /
    • 2012
  • The pencil beam convolution (PBC) algorithms in radiation treatment planning system have been widely used to calculate the radiation dose. A new photon dose calculation algorithm, referred to as the anisotropic analytical algorithm (AAA), was released for use by the Varian medical system. The aim of this paper was to investigate the difference in dose calculation between the AAA and PBC algorithm using the intensity modulated radiation therapy (IMRT) plan for lung cancer cases that were inhomogeneous in the low density. We quantitatively analyzed the differences in dose using the eclipse planning system (Varian Medical System, Palo Alto, CA) and I'mRT matirxx (IBA, Schwarzenbruck, Germany) equipment to compare the gamma evaluation. 11 patients with lung cancer at various sites were used in this study. We also used the TLD-100 (LiF) to measure the differences in dose between the calculated dose and measured dose in the Alderson Rando phantom. The maximum, mean, minimum dose for the normal tissue did not change significantly. But the volume of the PTV covered by the 95% isodose curve was decreased by 6% in the lung due to the difference in the algorithms. The difference dose between the calculated dose by the PBC algorithms and AAA algorithms and the measured dose with TLD-100 (LiF) in the Alderson Rando phantom was -4.6% and -2.7% respectively. Based on the results of this study, the treatment plan calculated using the AAA algorithms is more accurate in lung sites with a low density when compared to the treatment plan calculated using the PBC algorithms.

The Effect of Exercise Program on Chronic Low Back Pain in Female Teachers of Elementary School (만성요통 여교사에 대한 운동프로그램의 효과 - 근력, 근지구력, 유연성, 통증, 기능장애, 우울 및 생활만족도를 중심으로 -)

  • Choi, Soon-Young
    • Women's Health Nursing
    • /
    • v.7 no.2
    • /
    • pp.169-187
    • /
    • 2001
  • This study was performed to probe the effect of exercise program on muscle strength, endurance, flexibility, pain, disability level and life satisfaction in female teachers of elementary school who complain of low back pain. For this study, 44 female teachers aged 30-50 years with mechanical low back pain of 6 months' duration, who had the structural normalities in the lumbar spine, were recruited from April 1 to July 10 1999. Twenty three out of them were assigned to the experimental group and twenty one to the control group. The exercise program consisted of education on right postures, the etiology and diagnosis of low back pain, and exercise intervention such as muscle relaxation, elongation and strengthening. With 8 weeks program, the subjects received two sessions of education and six sessions of group exercise in the 1st week, while three sessions of group exercise and four sessions of individual exercise weekly and two sessions of education during the later 7 weeks. The muscle strength and endurance were measured by Cybex 770, the flexibility by flexibility measurement machine, the intensity of pain by Visual Analogue Scale (VAS), the level of disability by Oswestry low back pain disability scale, depression by Beck depression inventory (BDI), and life satisfaction by Life satisfaction index-Z. Study measurements were taken before and after 8 weeks exercise program. Data were analyzed using paired t-test, t-test, and ANCOVA. The results were as follows ; 1. The flexors and extensors peak torque and flexors peak torque per body weight of experimental group were significantly increased at test velocities $30^{\circ}$/sec, $60^{\circ}$/sec compared with those of control group. There was no significant difference in extensors peak torque per flexors peak torque at $30^{\circ}/sec$, $60^{\circ}/sec$ between experimental and control group. 2. The flexors and extensors total work and flexors total work per body weight of experimental group were significantly increased at $120^{\circ}/sec$, compared with those of control group. 3.The flexibility of lumbar spine in experimental group was significantly increased compared with that of control group. The pains in anterior, posterior, left lateral and right lateral bending and in rotation of experimental group were significantly increased compared with those of control group. 4. The Oswestry disability scores of experimental and control group were significantly decreased, and there was no difference in the Oswestry disability score change between experimental and control group. 5. The scores of BDI of experimental group were significantly decreased compared with those of control group. Life satisfaction index-Z scores of experimental group were not changed, but those of control group were significantly decreased. There was no difference in the score change of Life satisfaction index-Z between experimental and control group. 6. ANCOVA analysis for the data variables of inhomogeneous baseline represented that there was no significant difference in extensors peak torque and extensors total work at $120^{\circ}/sec$ and extensor total work per body weight at $120^{\circ}/sec$ change between experimental group and control group. These findings indicate that the exercise program could be effective in increasing the muscle strength, endurance, flexibility and decreasing pain, improving depression in female teachers of elementary school with chronic low back pain. It is suggested that the exercise program could be an essential factor for the effective nursing intervention to the patients suffered from chronic low back pain.

  • PDF

Analysis of Respiratory Motional Effect on the Cone-beam CT Image (Cone-beam CT 영상 획득 시 호흡에 의한 영향 분석)

  • Song, Ju-Young;Nah, Byung-Sik;Chung, Woong-Ki;Ahn, Sung-Ja;Nam, Taek-Keun;Yoon, Mi-Sun
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.81-86
    • /
    • 2007
  • The cone-beam CT (CBCT) which is acquired using on-board imager (OBI) attached to a linear accelerator is widely used for the image guided radiation therapy. In this study, the effect of respiratory motion on the quality of CBCT image was evaluated. A phantom system was constructed in order to simulate respiratory motion. One part of the system is composed of a moving plate and a motor driving component which can control the motional cycle and motional range. The other part is solid water phantom containing a small cubic phantom ($2{\times}2{\times}2cm^3$) surrounded by air which simulate a small tumor volume in the lung air cavity CBCT images of the phantom were acquired in 20 different cases and compared with the image in the static status. The 20 different cases are constituted with 4 different motional ranges (0.7 cm, 1.6 cm, 2.4 cm, 3.1 cm) and 5 different motional cycles (2, 3, 4, 5, 6 sec). The difference of CT number in the coronal image was evaluated as a deformation degree of image quality. The relative average pixel intensity values as a compared CT number of static CBCT image were 71.07% at 0.7 cm motional range, 48.88% at 1.6 cm motional range, 30.60% at 2.4 cm motional range, 17.38% at 3.1 cm motional range The tumor phantom sizes which were defined as the length with different CT number compared with air were increased as the increase of motional range (2.1 cm: no motion, 2.66 cm: 0.7 cm motion, 3.06 cm: 1.6 cm motion, 3.62 cm: 2.4 cm motion, 4.04 cm: 3.1 cm motion). This study shows that respiratory motion in the region of inhomogeneous structures can degrade the image quality of CBCT and it must be considered in the process of setup error correction using CBCT images.

  • PDF