EVALUATION OF NON-INVASIVE BLOOD GLUCOSE MEASUREMENT USING THREE TYPES OF NEAR INFRARED SPECTROMETER

  • Baek, Ju-Hyun;Kang, Na-Roo;Woo, Young-Ah;Kim, Hyo-Jin
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.1
    • /
    • pp.289.1-289.1
    • /
    • 2003
  • Three types of near infrared spectrometer, a photo diode array type, a dispersive type and a FT type, were evaluated and compared the systematic difference in blood glucose measurement. The fundamental study was performed by adding glucose to buffer solution and bovine blood as the preceding study of non-invasive blood glucose. Spectra were collected using a 1.0 mm optical pathlength quartz cell by transmittance method. (omitted)

  • PDF

태양전지 실리콘 웨이퍼를 위한 실험계획법 기반 근적외선 광학계의 최적조건 선정 (Optimal Parameter Selection of Near-Infrared Optics Based Design of Experiment for Silicon Wafer in Solar Cell)

  • 서형준;김경범
    • 반도체디스플레이기술학회지
    • /
    • 제12권3호
    • /
    • pp.29-34
    • /
    • 2013
  • Solar cell has been considered as renewable green energy. Its silicon wafer thickness is thinner due to manufacturing cost and accordingly micro cracks is often generated in the process. Micro cracks result in bad quality of solar cell, and so their accurate and reliable detection is required. In this paper, near-infrared optics system is newly designed based on the analysis of near-infrared transmittance characteristics and its important parameters are optimally selected using the design of experiment for micro crack detection in solar cell wafer. The performance of the proposed method is verified using several experiments.

근적외분광분석법을 이용한 인도메타신의 정량분석 (Quantitative Analysis of Indomethacin by the Portable Near-Infrared (NIR) System)

  • 김도형;우영아;김효진
    • 약학회지
    • /
    • 제47권5호
    • /
    • pp.261-265
    • /
    • 2003
  • Near-infrared (NIR) system was used to determine rapidly and simply indomethacin in buffer solution for a dissolution test of tablets and capsules. Indomethacin standards were prepared ranging from 10 to 50 ppm using the mixture of phosphate buffer (pH 7.2) and water (1 : 4). The near-infrared (NIR) transmittance spectra of indomethacin standard solutions were collected by using a quartz cell in 1 mm and 2 mm pathlength. Partial least square regression (PLSR) was explored to develop calibration models over the spectral range 1100∼1700 nm. The model using 1 mm quartz cell was better than that using 2 mm quartz cell. The PLSR models developed gave standard error of prediction (SEP) of 0.858 ppm. In order to validate the developed calibration model, routine analysis was performed using another standard solutions. The NIR routine analysis showed good correlation with actual values. Standard error of prediction (SEP) is 1.414 ppm for 7 indomethacin samples in routine analysis and its error was permeable in the regulation of Korean Pharmacopoeia (VII). These results show the potential use of the real time monitoring for indomethacin during a dissolution test.

Extraordinary Optical Transmission and Enhanced Magneto-optical Faraday Effect in the Cascaded Double-fishnet Structure with Periodic Rectangular Apertures

  • Lei, Chengxin;Man, Zhongsheng;Tang, Shaolong
    • Current Optics and Photonics
    • /
    • 제4권2호
    • /
    • pp.134-140
    • /
    • 2020
  • A significant enhancement of the magneto-optical Faraday rotation and extraordinary optical transmission (EOT) in the cascaded double-fishnet (CDF) structure with periodic rectangular apertures is theoretically predicted by using the extended finite difference time domain (FDTD) method. The results demonstrate that the transmittance spectrum of the CDF structure has two EOT resonant peaks in a broad spectrum spanning visible to near-infrared wavebands, one of them coinciding with the enhanced Faraday rotation and large figure of merit (FOM) at the same wavelength. It is most important that the resonant position and intensity of the transmittance, Faraday rotation and FOM can be simply tailored by adjusting the incident wavelength, the thickness of the magnetic layer, and the offset between two metallic rectangular apertures, etc. Furthermore, the intrinsic physical mechanism of the resonance characteristics of the transmittance and Faraday rotation is thoroughly studied by investigating the electromagnetic field distributions at the location of resonance. It is shown that the transmittance resonance is mainly determined by different hybrid modes of surface plasmons (SPs) and plasmonic electromagnetically induced transparency (EIT) behavior, and the enhancement of Faraday rotation is mostly governed by the plasmonic electromagnetically induced absorption (EIA) behavior and the conversion of the transverse magnetic (TM) mode and transverse electric (TE) mode in the magnetic dielectric layer.

네츠팩 렌즈의 광학적 특성 연구 (An Optical Characteristic Research of a Netspec Lens)

  • 이동희;김대진
    • 한국안광학회지
    • /
    • 제8권1호
    • /
    • pp.85-90
    • /
    • 2003
  • 네츠팩 렌즈는 일반 안경 렌즈에 2차원 그물망 코팅을 한 형태인데, 상을 선명하게 볼 수 있게 하고 눈의 피로를 덜어주며, 자외선과 적외선 영역에서의 투과율이 낮다고 알려져 있다. 이러한 네츠팩 렌즈의 특징을 과학적으로 입증할 필요가 있다. 그래서, 본 연구에서는 그물망 코팅에 대한 파장대별 투과율 계산식을 키르히호프의 스칼라 회절이론을 적용해 유도해보고, 이를 시뮬레이션 할 수 있는 프로그램을 제작하였으며, 시뮬레이션 결과에 대한 해석을 시도하였다. 결과적으로 우리는 그물망 코팅이 파장에 따른 빛의 투과율을 조절하는데 사용할 수 있다는 것을 알 수 있었다.

  • PDF

다성분계 Glass Fiber의 La$_2$O$_3$첨가에 따른 광학적 특성에 관한 연구 (The Study on Optical Properties by Adding La$_2$O$_3$ in Multicomponent Glass Fiber)

  • 김용호;강원호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1985년도 추계학술대회 논문집
    • /
    • pp.21-23
    • /
    • 1985
  • By adding La$_2$O$_3$ to optical multicomponent glass composition, after making mother glass and core fiber that enable to enlarge the infrared transmittance region, then surveyed the optical properties. Through thermal analysis of the glass abstained by melt-quenching after selecting stable basic composition on devitrification and replace SiO$_2$ by 4-12wt% La$_2$O$_3$. As La$_2$O$_3$ increases up to l2wt% transition temperature, refractive index, density, deformation temperature increased, whereas thermal expansion coefficient decreased. As a result of inspectig transmittance in UV/VIS/IR region, visable region indicated the decrease of transmittance by increasing the La$_2$O$_3$ and transmittance region was enlarged by increasing the La$_2$O$_3$ in IR region. Also, fabricate core fiber at 820$^{\circ}C$ and severy the optical loss we could fact that La$_2$O$_3$ composition added 12wt% showed the minimum optical loss.

고 에너지 전자빔 조사된 IGZO 박막의 광 투과도에 대한 연구 (A Study on the Optical Transmittance of High-energy Electron-beam Irradiated IGZO Thin Films)

  • 윤의중
    • 전자공학회논문지
    • /
    • 제51권6호
    • /
    • pp.71-77
    • /
    • 2014
  • 본 연구에서는 radio frequency(rf) 마그네트론 스퍼터링 기술을 이용하여 Corning 유리 기판에 증착된 InGaZnO (IGZO) 박막의 광 투과도 특성에 고 에너지 전자빔 조사(high-energy electron beam irradiation (HEEBI))이 미치는 영향을 연구하였다. 저온에서 증착된 IGZO 박막은 공기 중 과 상온 조건에서 0.8 MeV의 전자빔 에너지와 $1{\times}10^{14}-1{\times}10^{16}electrons/cm^2$ dose를 사용하여 HEEBI 처리 되었다. IGZO 박막의 광 투과도는 utraviolet visible near-infrared spectrophotometer (UVVIS)로 측정되었다. HEEBI 처리 된 IGZO/유리 이중층의 총 광 투과도에서 HEEBI 처리된 IGZO 단일막 만의 광 투과도를 분리하는 방법을 상세히 연구하였다. 실험 결과로부터 $1{\times}10^{14}electrons/cm^2$의 적절한 dose로 처리된 HEEBI가 IGZO 박막의 투명도를 극대화시킴을 알 수 있었다. 또한 이렇게 적절한 dose로 처리된 HEEBI가 광학 밴드갭($E_g$)을 3.38 eV에서 3.31 eV로 감소시킴을 알 수 있었다. 이러한 $E_g$의 감소는 적절한 dose로 공기 중 상온에서 처리된 HEEBI가 진공 중 고온에서 처리된 열적 annealing 효과와 유사함을 제시하고 있다.

다층 그래핀/유리 구조체의 적외선 열복사 특성 연구 (Thermal Radiative Properties of Multilayer Graphene/Glass Structure)

  • 박경아;임미경;정현준;김재현
    • 한국전기전자재료학회논문지
    • /
    • 제34권1호
    • /
    • pp.27-32
    • /
    • 2021
  • In this study, we fabricated multilayer graphene on a glass substrate by stacking the monolayer graphene synthesized via chemical vapor deposition. The electrical sheet resistance and optical transmittance were evaluated to confirm the quality of the stacked multilayer graphene. Using the fabricated multilayer graphene/glass structure, we characterized its thermal radiative property in terms of the integrated emissivity. The integrated emissivity of the multilayer graphene/glass structure was tuned from 0.91 to 0.72 when the number of graphene layers was changed from 1 to 12. We also demonstrated that the emissivity tunability provided a way to control the apparent temperature of an object that can be used in infrared stealth applications.

PREDICTION OF PHYSICO-CHEMICAL AND TEXTURE CHARACTERISTICS OF BEEF BY NEAR INFRARED TRANSMITTANCE SPECTROSCOPY

  • Olivan, Mamen;Delaroza, Begona;Mocha, Mercedes;Martinez, Maria Jesus
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1256-1256
    • /
    • 2001
  • The physico-chemical and texture characteristics of meat determine the nutritional, technological and sensory quality. However, the analysis of meat quality requires expensive, laborious and time consuming analytical methods. The objective of this study was to evaluate NIR spectroscopy using transmittance for determining the moisture, fat, protein and total pigment content, the water holding capacity (WHC) and the toughness of beef meat. A total of 318 spectra were recorded from ground beef samples by a Feed Analyzer 1265 of Infratec. The samples were obtained from the Longissimus muscle of the 10$^{th}$ rib of yearling bulls, ground with an electrical chopper, vacuum packaged, aged during 7 days and frozen at -24$^{\circ}C$ until the analyses were done. Moisture content was measured by oven drying at 10$0^{\circ}C$, fat content was determined by Soxhlet extraction and protein content was estimated from nitrogen content using the Kjeldahl analysis. The total pigment content was determined by the method of Hornsey and the WHC using the method of filter paper press. The instrumental evaluation of texture (maximum load WB, maximum stress MS and toughness) was conducted in an Instron equipment with a Warner-Bratzler shearing device. This analysis was performed on a chop of 3.5 cm obtained from the longissimus of the 8$^{th}$ rib, aged during 7 days, kept frozen at -24$^{\circ}C$ and cooked before the analysis. Near infrared spectra were recorded as log 1/T (T=transmittance) at 2 nm intervals from 850 to 1050 nm using a Feed Analyzer 1265 of Infratec. Calibrations were performed with the WinISI software (vs. 1.02) using the MPLS method. To examine the effect of scatter correction o. derivation of spectra on the calibration performance, calibrations were calculated with the crude spectra or pretreated with different mathematical treatments (inverse MSC, SNVD) and/or second derivative operation. For chemical composition, the use of the scatter corrections improved the calibration statistics, in terms of lower SECV and higher $r^2$. In most of the variables, the use of the 2$^{nd}$ derivative improved the predictions, mainly when combined with the SNVD treatment. However, for predicting the texture traits, the best estimation was obtained from the crude spectrum. These results showed that the equations obtained for predicting moisture, fat and total pigments were very accurate, with $r^2$ being higher that 0.9. However, the prediction of the texture traits (WB, MS, toughness) from ground meat was poor.

  • PDF

Dissolution Test for Indomethacin by the Portable Near-Infrared(NIR) System

  • Kim, Do-Hyung;Lim, Hun-Rang;Chang, Soo-Hyun;Woo, Young-Ah;Kim, Hyo-Jin
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2002년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2
    • /
    • pp.399.3-399.3
    • /
    • 2002
  • Near-infrared (NIR) system was used to determine rapidly and simply indomethacin in buffer solution for a dissolution test for tablets and capsules. Indomethacin standards were prepared ranging from 10 to 50ppm using mixture of phosphate buffer(pH 7,2) and water(1:4), The near infrared(NIR) transmittance spectra of indomethacin standard solutions were collected by using a quartz cell in 1 mm and 2mm pathlength, Partial least-square regression (PLSR) was explored to develop calibration models over the spectral range 1100-1700nm. (omitted)

  • PDF