• 제목/요약/키워드: Infrared thermal imaging

검색결과 303건 처리시간 0.031초

고온 환경에서의 적외선 열화상 측정에 관한 연구 (Research on Measurement of Infrared Thermograpphy under High Temperature Condition)

  • 이준식;전재욱
    • 한국산업융합학회 논문집
    • /
    • 제27권1호
    • /
    • pp.57-62
    • /
    • 2024
  • This study conducted a measurement method of high temeprature conditions using infrared termography. All objects emit infrared light, and this emissivity has a significant impact on the temperature measurements of infrared thermal imaging (IR) cameras. In order to measure the temperature more accurately with the IR camera, correction equations were derived by measuring the emissivity according to the temperature change of combustible metals in a high-temperature environment. Two combustible metals, Mg and Al, were used to measure emissivity with changing temperature. Each metal was heated, the emissivity was measured by comparing the temperature with IR camera and thermocouples so that the correlation between temperature and emissivity could be anslyzed. As a result of the experiment, the emissivity of the metals increases as the temperature increased. This can be interpreted as a result of increased radiation emission as the thermal movement of internal metal molecules increased.

초음파 열화상 검사를 이용한 박판 용접시편의 결함 검출 (A Defect Detection of Thin Welded Plate using an Ultrasonic Infrared Imaging)

  • 조재완;정진만;최영수;정승호;정현규
    • 제어로봇시스템학회논문지
    • /
    • 제13권11호
    • /
    • pp.1060-1066
    • /
    • 2007
  • When a high-energy ultrasound propagates through a solid body that contains a crack or a delamination, the two faces of the defect do not ordinarily vibrate in unison, and dissipative phenomena such as friction, rubbing and clapping between the faces will convert some of the vibrational energy to heat. By combining this heating effect with infrared imaging, one can detect a subsurface defect in material efficiently. In this paper a detection of the welding defect of thin SUS 304 plates using the UIR (ultrasonic infrared imaging) technology is described. A low frequency (20kHz) ultrasonic transducer was used to infuse the welded thin SUS 304 plates with a short pulse of sound for 280ms. The ultrasonic source has a maximum power of 2kW. The surface temperature of the area under inspection is imaged by a thermal infrared camera that is coupled to a fast frame grabber in a computer. The hot spots, which are a small area around the defect tip and heated up highly, are observed. From the sequence of the thermosonic images, the location of defective or inhomogeneous regions in the welded thin SUS 304 plates can be detected easily.

Measurement of temperature profile using the infrared thermal camera in turbulent stratified liquid flow for estimation of condensation heat transfer coefficients

  • Choi, Sung-Won;No, Hee-Cheon
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1999년도 춘계학술발표회요약집
    • /
    • pp.107-107
    • /
    • 1999
  • Direct-contact condensation experiments of atmospheric steam and steam/air mixture on subcooled water flowing co-currently in a rectangular channel are carried out uszng an infrared thermal camera system to develop a temperature measurement method. The inframetrics Model 760 Infrared Thermal Imaging Radiometer is used for the measurement of the temperature field of the water film for various flow conditions. The local heat transfer coefficient is calculated using the bulk temperature gradient along the (low direction. It is also found that the temperature profiles can be used to understand the interfacial condensation heat transfer characteristics according to the flow conditions such as noncondensable gas effects, inclination effect, and flow rates.

  • PDF

위증(療證)으로 진단한 하지마비 환자의 치험 1례 (Clinical Observation on 1 Case of Both Leg Paralysis Patient Diagnosed Wei Symptom)

  • 위통순
    • 동의생리병리학회지
    • /
    • 제20권3호
    • /
    • pp.748-752
    • /
    • 2006
  • Wei symptom(?證) is symptom that reveals muscle relaxation without contraction and muscle relaxation occurs in the lower or upper limb, in severe case, leads to death. This is the clinical report about the Wei symptom(?證)-patient doubt as Transverse Myelitis and Conversion Disorder. The patient was treated by acupuncture, moxibustion, herb medication(十全大補湯), electriccal stimulation theraphy, Bee Venom acupuncture, and had significant improvement in Wei symptom(?證). these results suggest the surface temperature differ remarkably from before being treated. The temperature is measured by using Digital Infrared Thermal Imaging(DITI). The results suggest that oriental medicare is an effective treatment for Wei symptom. We expected that therapeutic value of treatment of both leg Paralysis in the oriental medicine will be higher if more clinical studies and researches are accomplished.

자궁적출술 후 증후군의 한방치료 전후 체온분포 변화에 관한 임상보고 (A clinical report of thermographic change after Korean Medicine Treatment on post-hysterectomy syndrome patients)

  • 김지희;이기승;김준철
    • 대한의료기공학회지
    • /
    • 제14권1호
    • /
    • pp.52-62
    • /
    • 2014
  • Objective : The aim of this study is to analyze the effectiveness of Korean Medicine treatment on post-hysterectomy syndrome patients by thermographic change during treatment. Methods : 5 female patients who had a hysterectomy within a year were treated with Korean Medicine concluding acupuncture, herbal medicine, cupping therapy, herbal bath. We evaluated the thermographic differences by checking Digital Infrared Thermal Imaging(D.I.T.I.) at CV17(膻中), CV4(關元), ST3(巨髎), BL15(心兪), and BL23(腎兪). Results : In consequence of Korean Medicine Treatment for 3 weeks, thermographic differences between CV17(膻中) and CV4(關元), ST3(巨髎) and CV4(關元), BL15(心兪), and BL23(腎兪) tended to decrease. Conclusion : After Korean Medicine treatment, thermographic differences between upper body and lower body tended to decrease cause shangrexiahanzheng(上熱下寒證) made by hysterectomy became moderated.

Digital Infrared Thermal Imaging에 따른 수족냉증 중증도와 Heart Rate Variability의 상관관계 연구 (Study on the Correlation between Digital Infrared Thermal Imaging-induced Severity of Cold Hypersensitivity of Hands and Feet and Heart Rate Variability)

  • 우혜린;박연경;김준호;박경선;황덕상;이진무;장준복;이창훈
    • 대한한방부인과학회지
    • /
    • 제29권3호
    • /
    • pp.1-9
    • /
    • 2016
  • Objectives: Cold Hypersensitivity of Hands and Feet (CHHF) has been diagnosed objectively by Digital Infrared Thermal Imaging (DITI) and has been known to be associated with autonomic nervous system (ANS), which can be assessed by Heart Rate Variability (HRV). This study evaluated the correlation between severity of CHHF and HRV variables.Methods: We studied 155 non-menopausal women with CHHF who visited Kyung Hee University Hospital at Gangdong from 01 October 2013 to 30 April 2016. We measured DITI and HRV of each patient. We used DITI to calculate the severity of CHHF with thermal difference between upper arm (L4, 俠白穴) and palm (P8, 勞宮穴) of both hands and anterior thigh (ST32, 伏兎穴) and dorsum of foot (LI3, 太衝穴) of both feet. The correlation between severity of CHHF and HRV variables were analyzed.Results: In time domain analysis, there was significantly positive correlation between the severity of CHHF and both SDNN and RMSSD. In frequency domain analysis, there was significantly positive correlation between the severity of CHHF and TP, HF and HF Norm while there was significantly negative correlation between the severity of CHHF and LF Norm as well as between the severity of cold hypersensitivity of both hands and LF/HF ratio.Conclusions: The more severe CHHF is, the more increased the function of parasympathetic nerve system (PNS) and relatively decreased the function of sympathetic nerve system (SNS) is. Also, it has known that cold hypersensitivity could be caused by deficiency syndrome and qi deficiency has the same ANS tendency as CHHF. Therefore, in practical fields, this result can be helpful in planning treatment and deciding prognosis in respect of deficiency syndrome.

320x240 적외선 배열검출기를 이용한 고분해능 열상 신호처리기 구현 (High Resolution Electronic Processor Design for Thermal Imager with 320x240 Staring Array Infrared Detector)

  • 홍석민;유위경;윤은숙
    • 한국군사과학기술학회지
    • /
    • 제9권2호
    • /
    • pp.111-117
    • /
    • 2006
  • This paper describes the design principles and methods of electronic processor for thermal imager with 320$\times$240 staring array infrared detector. For the detector's nonuniformity correction and excellent image quality, we have designed the multi-point correction method using the defocusing technique of the optics. And to enhance the image of low contrast and improve the detection capability, the new technique of histogram processing has been designed. Through these image processing techniques, we have developed the high quality thermal imager and acquired a satisfactory thermal image. The result of MRTD(Minimum Resolvable Temperature Difference) is $0.1^{\circ}C$ at 4cycles/mard.

열변형 보정을 통한 열화상카메라용 초정밀 칼코지나이드 유리렌즈 몰드성형 및 특성 평가 (Molding and Evaluation of Ultra-Precision Chalcogenide-Glass Lens for Thermal Imaging Camera Using Thermal Deformation Compensation)

  • 차두환;김정호;김혜정
    • 한국전기전자재료학회논문지
    • /
    • 제27권2호
    • /
    • pp.91-96
    • /
    • 2014
  • Aspheric lenses used in the thermal imaging are typically fabricated using expensive single-crystal materials (Ge and ZnS, etc.) by the costly single point diamond turning (SPDT) process. As a potential solution to reduce cost, compression molding method using chalcogenide glass has been attracted to fabricate IR optic. Thermal deformation of a molded lens should be compensated to fabricate chalcogenide aspheric lens with form accuracy of the submicron-order. The thermal deformation phenomenon of molded lens was analyzed ant then compensation using mold iteration process is followed to fabricate the high accuracy optic. Consequently, it is obvious that compensation of thermal deformation is critical and useful enough to be adopted to fabricate the lens by molding method.

구강작열감증후군 환자의 적외선체열검사와 정량적 평가 특성 : 단면조사연구 (Characteristics of Digital Infrared Thermal Imaging and Quantitative Evaluations for Patients with Burning Mouth Syndrome: a Cross Sectional Study)

  • 고휘형;남성욱;하나연;황미니;백소영;김동윤;김진성
    • 대한한방내과학회지
    • /
    • 제39권4호
    • /
    • pp.699-707
    • /
    • 2018
  • Objectives: This study was designed to investigate characteristics of digital infrared thermal imaging (DITI) and quantitative evaluations in patients with burning mouth syndrome (BMS). Methods: We reviewed the clinical records of 38 patients with BMS who visited the Oral Diseases Clinic of Kyung Hee University Korean Medicine Hospital from March 1st, 2018 to June 30th, 2018. The subjects were evaluated with digital infrared thermal imaging (DITI) and for heart rate variability (HRV), unstimulated salivary flow rate (USFR), and the proportion of coated tongue. Results: Most patients showed higher temperatures on the central part of the tongue (T2) than on the middle of the forehead (T1). The patients tended to have a high Low frequency/High frequency (LF/HF) ratio. Statistically significant negative correlations were noted between the age of patients and the temperature of T1 and T2. Statistically significant negative correlations were also observed between the LF/HF ratio and 'T1-T2' values. Conclusions: This study suggests that DITI and HRV are useful for the validation of patients with BMS. Correlations between the result values suggest that sympathetic function acceleration is related to temperature distribution and, ultimately, to symptoms.