• 제목/요약/키워드: Infrared Thermometry

검색결과 9건 처리시간 0.021초

Comparison of Rectal and Infrared Thermometry for Obtaining Body Temperature of Gnotobiotic Piglets in Conventional Portable Germ Free Facility

  • Chung, Tae-Ho;Jung, Woo-Sung;Nam, Eui-Hwa;Kim, Ji-Hyun;Park, Seol-Hee;Hwang, Cheol-Yong
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제23권10호
    • /
    • pp.1364-1368
    • /
    • 2010
  • Gnotobiotic piglets (n = 10) were hand-reared in conventional germ-free facilities. Piglet body temperatures were measured with rectal and non-contact infrared thermometry (NIFT) on the lower eyelid, auricular center and margin, parietal regions, axilla, central abdomen and dorsum, and the perianal region. Body temperature measurements at central abdomen, cranial dorsum, and perianal regions had NIFT values which had a significant linear relationship (p<0.0001) with rectal thermometry. The predicted equations of between-subject formulas were calculated as follows: rectal temperature, 28.07489+0.30372${\times}$central abdominal surface temperature; rectal temperature, 34.02799+0.15197${\times}$central dorsum surface temperature; and rectal temperature, 33.87937+0.15676${\times}$perianal temperature. These results suggested that NIFT could serve as a valid alternative to rectal thermometry in a portable germ-free facility without disturbing experimental animals. The development of a NIFT body temperature evaluation that does not require animal restraint is clinically advantageous, particularly in gnotobiotic piglets, and would be significantly less stressful for experimental procedures in germ-free facilities.

온실작물의 관개계획의 수립을 위한 엽온의 활용 (Using Leaf Temperature for Irrigation Scheduling in Greenhouse)

  • 이남호;이훈선
    • 한국농공학회지
    • /
    • 제43권6호
    • /
    • pp.103-112
    • /
    • 2001
  • The development of infrared thermometry has led many researchers to use plant temperatures, and specifically the temperature of the crop canopy in the field, for estimating the water stress of a crop. The purpose of this study was to evaluate the role of leaf temperature in irrigation scheduling. An experiment was carried out in a greenhouse with chinese cabbage. Leaf temperature was measured with infrared thermometry and evapotranspiration of the crop was measured by lysimeters. Influence of the difference between leaf temperature and air temperature on crop evapotranspiration was evaluated under varying water stress condition. A further objective was to evaluate the effect of other climatic variables on the relationship between evapotranspiration and temperature difference between leaf and air. A statistical model for estimating evapotranspiration using the temperature difference, relative humidity. and radiation was developed and tested. Crop water stress index was calculated using vapour pressure deficit and the temperature difference. Relations between the crop water stress index and crop evapotranspiration was tested. The index was closely related with evapotranspiration.

  • PDF

Development of an Infrared Two-color Probe for Particle Cloud Temperature Measurement

  • Alshaikh Mohammed, Mohammed Ali;Kim, Ki Seong
    • 한국분무공학회지
    • /
    • 제20권4호
    • /
    • pp.230-235
    • /
    • 2015
  • The demands for reliable particle cloud temperature measurement exist in many process industries and scientific researches. Particle cloud temperature measurements depend on radiation thermometry at two or more color bands. In this study, we developed a sensitive, fast response and compact online infrared two-color probe to measure the temperature of a particle cloud in a phase of two field flow (solid-gas). The probe employs a detector contained two InGaAs photodiodes with different spectral responses in the same optical path, which allowed a compact probe design. The probe was designed to suit temperature measurements in harsh environments with the advantage of durability. The developed two-color probe is capable of detecting particle cloud temperature as low as $300^{\circ}C$, under dynamic conditions.

Direct-contact heat transfer of single droplets in dispersed flow film boiling: Experiment and model assessment

  • Park, Junseok;Kim, Hyungdae
    • Nuclear Engineering and Technology
    • /
    • 제53권8호
    • /
    • pp.2464-2476
    • /
    • 2021
  • Direct-contact heat transfer of a single saturated droplet upon colliding with a heated wall in the regime of film boiling was experimentally investigated using high-resolution infrared thermometry technique. This technique provides transient local wall heat flux distributions during the entire collision period. In addition, various physical parameters relevant to the mechanistic modelling of these phenomena can be measured. The obtained results show that when single droplets dynamically collide with a heated surface during film boiling above the Leidenfrost point temperature, typically determined by droplet collision dynamics without considering thermal interactions, small spots of high heat flux due to localized wetting during the collision appear as increasing Wen. A systematic comparison revealed that existing theoretical models do not consider these observed physical phenomena and have lacks in accurately predicting the amount of direct-contact heat transfer. The necessity of developing an improved model to account for the effects of local wetting during the direct-contact heat transfer process is emphasized.

수직 벽면에서 과냉 핵비등 시 열유속 분배에 관한 실험적 연구 (Experimental Study on Heat Flux Partitioning in Subcooled Nucleate Boiling on Vertical Wall)

  • 송준규;박준석;정샛별;김형대
    • 대한기계학회논문집B
    • /
    • 제38권6호
    • /
    • pp.465-474
    • /
    • 2014
  • 본 연구에서는 비등 열유속 분배 모델의 예측 정확성을 검증하기 위하여 수직평판 자연대류 과냉 비등에서 기화, 급랭, 및 단상대류 열전달 기구에 대한 열유속 분배 특성을 실험적으로 조사하였다. 비등 열유속의 분배를 위해 적외선 열화상 기법과 전반사 가시화 기법을 동기화하여 비등 표면의 열유속 분포와 액상-기상 분포를 동시에 측정하여 분석하는 실험을 수행하였다. 실험은 대기압 조건에서 과냉도 $10^{\circ}C$를 가지는 물을 이용하여 수행하였으며, 벽면과열도 $12^{\circ}C$ 및 평균 열유속 $283kW/m^2$ 조건에 대한 실험 결과를 분석에 활용하였다. 실험을 통해 획득된 열유속 분배 결과는 상관식을 이용한 예측 결과와 큰 차이를 보였으며, 기포이탈직경과 기포이탈 시 주변의 과열액체층이 함께 뜯겨져 나가는 효과를 고려한 기포영향인자가 차이를 만드는 주요 원인들로 파악되었다.

흑구온도를 이용한 천궁 엽온 예측 모델 개발 (Developing a Model for Estimating Leaf Temperature of Cnidium officinale Makino Based on Black Globe Temperature)

  • 서영진;남효훈;장원철;이부용
    • 한국약용작물학회지
    • /
    • 제26권6호
    • /
    • pp.447-454
    • /
    • 2018
  • Background: The leaf temperature ($T_{LEAF}$) is one of the most important physical parameters governing water and carbon flux, including evapotranspiration, photosynthesis and respiration. Cnidium officinale is one of the important folk medicines for counteracting a variety of diseases, and is particularly used as a traditional medicinal crop in the treatment of female genital inflammatory diseases. In this study, we developed a model to estimate $T_{Leaf}$ of Cnidium officinale Makino based on black globe temperature ($T_{BGT}$). Methods and Results: This study was performed from April to July 2018 in field characterized by a valley and alluvial fan topography. Databases of $T_{LEAF}$ were curated by infrared thermometry, along with meteorological instruments, including a thermometer, a pyranometer, and an anemometer. Linear regression analysis and Student's t-test were performed to evaluate the performance of the model and significance of the parameters. The correlation coefficient between observed $T_{LEAF}$ and calculated $T_{BGT}$ obtained using an equation, developed to predict $T_{LEAF}$ based on $T_{BGT}$ was very high ($r^2=0.9500$, p < 0.0001). There was a positive relationship between $T_{BGT}$ and solar radiation ($r^2=0.8556$, p < 0.0001), but a negative relationship between $T_{BGT}$ and wind speed ($r^2=0.9707$, p < 0.0001). These results imply that heat exchange in leaves seems to be mainly controlled by solar radiation and wind speed. The correlation coefficient between actual and estimated $T_{BGT}$ was 0.9710 (p < 0.0001). Conclusions: The developed model can be used to accurately estimate the $T_{Leaf}$ of Cnidium officinale Makino and has the potential to become a practical alternative to assessing cold and heat stress.

Leidenfrost 지점 온도 이상에서 액적-벽면 충돌 열전달에 대한 충돌 속도의 영향 (The Effect of Impact Velocity on Droplet-wall Collision Heat Transfer Above the Leidenfrost Point Temperature)

  • 박준석;김형대;배성원;김경두
    • 대한기계학회논문집B
    • /
    • 제39권7호
    • /
    • pp.567-578
    • /
    • 2015
  • Leidenfrost 온도 이상으로 가열된 벽면과 충돌하는 액적의 속도가 열전달 특성에 미치는 영향에 관한 실험 연구를 수행하였다. 동기화된 초고속 가시화 카메라와 적외선 카메라를 이용하여 벽면과 충돌하는 액적의 충돌 특성과 충돌면의 온도 분포를 측정하였다. 획득한 표면온도 분포를 충돌면의 경계 조건으로 이용하여 가열 벽면의 3차원 비정상 열전도 수치해석을 통해 표면 열유속 분포를 얻었다. 수직방향 충돌속도가 증가할수록 최대 액막 직경이 증가하고 가열 벽면과 액막 사이에 존재하는 증기막의 두께가 감소하여 열전달 효율이 증가하였다. 액적은 웨버수가 30보다 작은 경우 되튐현상이 발생하였으며, 큰 경우 작은 액적들로 분쇄되어졌다. 충돌속도에 의한 열전달량의 증가 경향이 되튐영역에서 분쇄영역에서 가면서 약화되었으며, 이는 분쇄현상에 의해 유효 열전달 면적의 확대 효과가 저감되었기 때문으로 해석된다.