• 제목/요약/키워드: Infrared Thermal Imaging Camera

검색결과 77건 처리시간 0.028초

적외선 열화상 카메라를 이용한 퍼지추론 기반 열화진단 시스템 개발 (Development of Fuzzy Inference-based Deterioration Diagnosis System Using Infrared Thermal Imaging Camera)

  • 최우용;김종범;오성권;김영일
    • 전기학회논문지
    • /
    • 제64권6호
    • /
    • pp.912-921
    • /
    • 2015
  • In this paper, we introduce fuzzy inference-based real-time deterioration diagnosis system with the aid of infrared thermal imaging camera. In the proposed system, the infrared thermal imaging camera monitors diagnostic field in real time and then checks state of deterioration at the same time. Temperature and variation of temperature obtained from the infrared thermal imaging camera variation are used as input variables. In addition to perform more efficient diagnosis, fuzzy inference algorithm is applied to the proposed system, and fuzzy rule is defined by If-then form and is expressed as lookup-table. While triangular membership function is used to estimate fuzzy set of input variables, that of output variable has singleton membership function. At last, state of deterioration in the present is determined based on output obtained through defuzzification. Experimental data acquired from deterioration generator and electric machinery are used in order to evaluate performance of the proposed system. And simulator is realized in order to confirm real-time state of diagnostic field

TEC-less 비냉각 열영상 검출기용 소형카메라 모듈 개발 (Small Camera Module for TEC-less Uncooled Thermal Image)

  • 김종호
    • 대한임베디드공학회논문지
    • /
    • 제12권2호
    • /
    • pp.97-103
    • /
    • 2017
  • Thermal imaging is mainly used in military equipment required for night observation. In particular, technologies of uncooled thermal imaging detectors are being developed as applied to low-cost night observation system. Many system integrators require different specifications of the uncooled thermal imaging camera but their development time is short. In this approach, EOSYSTEM has developed a small size, TEC-less uncooled thermal imaging camera module with $32{\times}32mm$ size and low power consumption. Both domestic detector and import detector are applied to the EOSYSTEM's thermal imaging camera module. The camera module contains efficient infrared image processing algorithms including : Temperature compensation non-uniformity correction, Bad/Dead pixel replacement, Column noise removal, Contrast/Edge enhancement algorithms providing stable and low residual non-uniformity infrared image.

적외선 열화상 카메라를 이용한 용접부의 온도 측정 방법 (Method for Measuring Weld Temperature Using an Infrared Thermal Imaging Camera)

  • 노찬승;김경석;장호섭
    • 비파괴검사학회지
    • /
    • 제34권4호
    • /
    • pp.299-304
    • /
    • 2014
  • 본 연구에서는 적외선 열화상 카메라와 열원 사이에 유리를 설치하여 측정기기의 보호 및 온도 보정을 통하여 고온의 용접부 온도를 실시간으로 측정하고자 하였다. 먼저 할로겐램프의 열에 대한 온도 차이를 실시간으로 촬영하고 온도를 측정한 결과, 카메라와 열원 사이의 거리별 온도는 거의 동일하게 측정되었음을 확인할 수 있었고, 유리 두께와 측정 거리의 상관관계를 통하여 온도 범위를 예측할 수 있다는 것을 알 수 있었다. 이를 바탕으로 용접열원에 대한 실험을 수행하여 열화상 카메라를 이용한 용접부의 온도 측정의 타당성을 제시하였다.

적외선열화상카메라의 응답 및 노이즈 특성 평가 (Responsivity and Noise Evaluation of Infrared Thermal Imaging Camera)

  • 김동익;김기석;김건희;장기수
    • 비파괴검사학회지
    • /
    • 제33권4호
    • /
    • pp.342-348
    • /
    • 2013
  • 본 논문에서는 비접촉 비파괴검사에 사용되는 적외선열화상카메라의 응답 및 노이즈 특성을 평가할 수 있는 방법을 제시하고 있으며 차동모드흑체의 적외선 표적과 그 주변의 온도차 ${\Delta}$T를 이용하여 상용 적외선열화상카메라의 신호전달함수 및 온도분해능을 구하고 그 결과를 카메라 사양과 비교함으로써 본 평가 방법의 적합성을 검증하였다. 또한 비균일성 보정의 적용 유무로부터 나타나는 온도분해능의 차이 0.01 K을 통하여 적외선열화상카메라의 성능평가에 있어서 비균일성 보정이 필수적인 과정임을 확인하였다.

Inspection of Calandria Reactor Surface of Wolsung Nuclear Power Plant using Thermal Infrared Camera mounted on the Mobile Robot KAEROT/m2

  • Cho, Jai-Wan
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2002년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.578-578
    • /
    • 2002
  • Thermal infrared imaging is a highly promising technology for condition monitoring and predictive maintenance of electronic, electrical and mechanical elements in nuclear power plants. However, conventional low-cost infrared imaging systems suffer from poor spatial resolution compared to commercial CCD cameras. This paper describes an approach to enhance inspection performances for calandria reactor area of Wolsung nuclear power plant through the technique of superimposing thermal infrared image into real CCD image. In the occurrence of thermal abnormalities on observation points and areas of calandria reactor area, unusual hot image taken from thermal infrared camera is mapped upon real CCD image. The performance of the technique has been evaluated in the experiment carried out at Wolsung nuclear power plant in the overhaul period. The results show that localizations of thermal abnormalities on calandria reactor face can be estimated accurately.

  • PDF

쑥뜸과 1064 nm 파장의 근적외선 레이저로 가열된 아가젤 조직 팬텀 심부의 온도분포 가시화 (Visualization of Temperature Distribution Deep Inside the Agar Gel Tissue Phantom Heated Using Moxibustion and 1064 nm Infrared Laser)

  • 조지용;김중경
    • 한국가시화정보학회지
    • /
    • 제8권4호
    • /
    • pp.54-59
    • /
    • 2010
  • A laser moxibustion therapy device having effect similar to that of traditional moxibustion is being developed using 1064 nm infrared laser. The therapy device allows direct interaction of laser light with the tissue rendering temperature distribution both on the skin surface and deep under the skin. We made a device that could measure temperature of deep under the surface of agar gel tissue phantom using thermocouples. A thermal imaging camera was used to verify results from the temperature measurement device. We compared the characteristics of heat transfer inside the tissue phantom during moxibustion and laser irradiation. The temperature distribution measured by thermocouples was found to be similar to that of distribution given by thermal imaging camera.

피어슨 상관계수를 이용한 적외선 열화상 안전 진단 시스템 개발 (The Development of Infrared Thermal Imaging Safety Diagnosis System Using Pearson's Correlation Coefficient)

  • 정종문;박성훈;이용식;김재현
    • 한국태양에너지학회 논문집
    • /
    • 제39권6호
    • /
    • pp.55-65
    • /
    • 2019
  • With the rapid development of the national industry, the importance of electrical safety was recognized because of a lot of new electrical equipment are installing and the electrical accidents have been occurring annually. Today, the electrical equipments is inspect by using the portable Infrared thermal imaging camera. but the most negative element of using the camera is inspected for only state of heating, the reliable diagnosis is depended with inspector's knowledge, and real-time monitoring is impossible. This paper present the infrared thermal imaging safety diagnosis system. This system is able to monitor in real time, predict the state of fault, and diagnose the state with analysis of thermal and power data. The system consists of a main processor, an infrared camera module, the power data acquisition board, and a server. The diagnostic algorithm is based on a mathematical model designed by analyzing the Pearson's Correlation Coefficient between temperature and power data. To test the prediction algorithm, the simulations were performed by damaging the terminals or cables on the switchboard to generate a large amount of heat. Utilizing these simulations, the developed prediction algorithm was verified.

Microphone Array와 열화상 카메라를 이용한 고압설비 고장검출 (Malfunction Detection of High Voltage Equipment Using Microphone Array and Infrared Thermal Imaging Camera)

  • 한순신;최재영;이장명
    • 제어로봇시스템학회논문지
    • /
    • 제16권1호
    • /
    • pp.25-32
    • /
    • 2010
  • The paper proposes a hierarchical fault detection method for the high voltage equipment using a microphone array which detects the location of fault and the thermal imaging and CCD cameras which verifies the fault and stores the image, respectively. There are partial arc discharges on the faulty insulators, which generates a specific pattern of sound. Detecting the signal using the microphone array, the location of the faulty insulator can be estimated. The 6th band-pass filter was applied to remove noise signal from wind or external influence. When the mobile robot carries the thermal and CCD cameras to the possible place of the fault insulator, the fault insulators or power transmission wires can be detected by the thermal images, which are caused by the aging or natural erosion. Finally, the CCD camera captures the image of the fault insulator for the record. The detection scheme of fault location using the microphone array and the thermal images have been proved to be effective through the real experiments. As a result of this research, it becomes possible to use a mobile robot with the integrated sensors to detect the fault insulators instead of a human being.

Characteristics of Infrared Blocking, Stealth and Color Difference of Aluminum Sputtered Fabrics

  • Han, Hye Ree
    • 한국의류학회지
    • /
    • 제43권4호
    • /
    • pp.592-604
    • /
    • 2019
  • This study examines the stealth function of sputtered fabric with an infrared thermal imaging camera in terms of the thermal and infrared (IR) transmittance characteristics. Various base fabrics were selected, infrared imaging was performed, and infrared transmittance was measured. By infrared camera experiment it was found that the sample was concealed because it had a similar color to the surroundings when the aluminum layer was directed toward the outside. In addition, a comparison of the infrared thermographic image of the untreated sample and the sputtered sample in the laboratory showed that the difference in ${\Delta}E$ value ranged from 31 to 90.4 and demonstrated effective concealment. However, concealment was not observed in the case of the 3-layer (Nylon-Al-Nylon) model when a sputtered aluminum layer existed between two nylon layers. The direction of the sputtering layer did not affect the infrared transmittance in the infrared transmittance experiment. Therefore, it seems better to interpret the concealing effect in the infrared thermographic images by using thermal transfer theory rather than infrared transmittance theory. We believe that the results of this study will be applicable to developing high performance smart clothing and military uniforms.

Inspection of Calandria Reactor Area of Wolsung NPP using Thermal Infrared and CCD Images

  • Cho, Jai-Wan;Kim, Chang-Hoi;Seo, Yong-Chil;Park, Young-Soo;Kim, Seung-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.96.4-96
    • /
    • 2002
  • Thermal infrared imaging is a highly promising technology for condition monitoring and predictive maintenance of electronic, electrical and mechanical elements in nuclear power plants. However, conventional low-cost infrared imaging systems suffer from poor spatial resolution compared to commercial CCD cameras. This paper describes an approach to enhance inspection performances for calandria reactor area of Wolsung nuclear power plant through the technique of superimposing thermal infrared image into real CCD image. In the occurrence of thermal abnormalities on observation points and areas of calandria reactor area, unusual hot image taken from thermal infrared camera is mapped upon re...

  • PDF