• Title/Summary/Keyword: Infrared Thermal Imaging

Search Result 303, Processing Time 0.028 seconds

THE BASIC PRINCIPLES AND TECHNICAL TRENDS OF THERMAL IMAGING SYSTEMS (적외선 열 영상장비의 기본원리 및 기술동향)

  • Hong, S.M.;Song, I.S.;Kwon, W.K.;Kim, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1255-1259
    • /
    • 1992
  • All matter above absolute zero emits thermal energy. Thermal imaging system converts the infrared radiation of a scene into a live picture of that scene : the thermal image is a pictorial representation of temperature differences. This paper has outlined the principles of thermal imaging and has briefly reviewed the history, and the present day and future technology.

  • PDF

Visible Light and Infrared Thermal Image Registration Method Using Homography Transformation (호모그래피 변환을 이용한 가시광 및 적외선 열화상 영상 정합)

  • Lee, Sang-Hyeop;Park, Jang-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.6_2
    • /
    • pp.707-713
    • /
    • 2021
  • Symptoms of foot-and-mouth disease include fever and drooling a lot around the hoof, blisters in the mouth, poor appetite, blisters around the hoof, and blisters around the hoof. Research is underway on smart barns that remotely manage these symptoms through cameras. Visible light cameras can measure the condition of livestock such as blisters, but cannot measure body temperature. On the other hand, infrared thermal imaging cameras can measure body temperature, but it is difficult to measure the condition of livestock. In this paper, we propose an object detection system using deep learning-based livestock detection using visible and infrared thermal imaging composite camera modules for preemptive response

A Study on the Best Applicationsof Infra-Red(IR) Sensors Mounted on the Unmanned Aerial Vehicles(UAV) in Agricultural Crops Field (무인기 탑재 열화상(IR) 센서의 농작물 대상 최적 활용 방안 연구)

  • Ho-Woong Shon;Tae-Hoon Kim;Hee-Woo Lee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.6_2
    • /
    • pp.1073-1082
    • /
    • 2023
  • Thermal sensors, also called thermal infrared wavelength sensors, measure temperature based on the intensity of infrared signals that reach the sensor. The infrared signals recognized by the sensor include infrared wavelength(0.7~3.0㎛) and radiant infrared wavelength(3.0~100㎛). Infrared(IR) wavelengths are divided into five bands: near infrared(NIR), shortwave infrared(SWIR), midwave infrared(MWIR), longwave infrared(LWIR), and far infrared(FIR). Most thermal sensors use the LWIR to capture images. Thermal sensors measure the temperature of the target in a non-contact manner, and the data can be affected by the sensor's viewing angle between the target and the sensor, the amount of atmospheric water vapor (humidity), air temperature, and ground conditions. In this study, the characteristics of three thermal imaging sensor models that are widely used for observation using unmanned aerial vehicles were evaluated, and the optimal application field was determined.

Automatic Intelligent Asymmetry Detection Using Digital Infrared Imaging with K-Means Clustering

  • Kim, Kwang Baek;Song, Doo Hoen
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.15 no.3
    • /
    • pp.180-185
    • /
    • 2015
  • Digital infrared thermal imaging is a non-invasive adjunctive diagnostic technique that allows an examiner to visualize and quantify changes in skin surface temperature. The asymmetry of temperature differences between the diseased and the contralateral healthy body parts can be automatically analyzed and has been studied in many areas of medical science. In this paper, we propose a method for intelligent automatic asymmetry detection based on a K-means analysis and a YCbCr color model. The implemented software successfully visualizes an asymmetric distribution of colors with respect to the patients’ health status.

The Utilization of Nondestructive Testing and Defects Diagnosis using Infrared Thermography (적외선 열화상을 이용한 비파괴시험 활용 및 결함 진단)

  • Choi, Man-Yong;Kim, Won-Tae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.5
    • /
    • pp.525-531
    • /
    • 2004
  • In this paper, the concept of infrared thermography(IRT), the principle of measurement of IRT and how to set up the IR camera for the nondestructive testing are described in detail. Also, its utilization and non-destructive testing(NDT) diagnosis are reviewed. By performing the periodic non-touched WDT through the estimation of thermal patterns related with the temperature for the surface targeted, IRT can be applied to the early prevention of the device failure. For the diagnosis utilization, thermal imaging patterns obtained from IRT for heated blocks with internal defects were estimated through the lion-destructive method and discussed the way of IRT estimation from the analysis of characteristics between material defects and thermal imaging patterns.

A Study on the Improvement of Image Quality for a Thermal Imaging System with focal Plane Array Typed Sensor (초점면 배열 방식 열상 카메라 시스템의 화질 개선 연구)

  • 박세화
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.1 no.2
    • /
    • pp.27-31
    • /
    • 2000
  • Thermal imaging system is implemented for the measurement and the analysis of the thermal distribution of the target objects. The main Part of the system is thermal camera in which a focal plane array typed sensor is introduced The sensor detects mid-range infrared spectrum or target objects and then it output generic video signal which should be processed to form a thermal image frame. A digital signal processor(DSP) in the system inputs analog to digital converted data. performs algorithms to improve the thermal images and then outputs the corrected frame data to frame buffers for NTSC encoding and for digital outputs.. To enhance the quality of the thermal images, two point correction method is applied. Figures indicate that the corrected thermal images are much improved.

  • PDF

DEVELOPMENT OF QUALITY EVALUATION SYSTEM FOR PEANUT WITH POD USING OPTICAL METHODS

  • Morta, Kazuo;Taharazako, Shoji;Zhang, Han;Maekaji, Kenji;Ikeda, Hirohiko
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.1354-1363
    • /
    • 1993
  • Optical methods were developed to examine their feasibility for quality evaluation of peanut with pod. Surface color and internal quality of peanut were measured without contact. The surface color of peanut was measured by light reflectance at a region of visible wavelengths. Its characteristic was high correlated with a visual grading of peanut. A trial machine for the color grading of peanut was developed using an optical sensor and it was considered to compare with the visual grading. The spectral reflectance at a region of near infrared wavelengths from 1,200 to 2,500nm was measured , and the chemical components of peanut were related to spectral reflectance at special wavelengths. The protein, fat and moisture contents of peanut were estimated by the near infrared methods. An infrared imaging method was developed to evaluate the internal quality of peanut with pod. As thermal characteristic of peanut with pod was deeply related to internal quality , the quality of peanut can be evaluated by temperature changes on the surface of peanut. Measurement of surface color, near infrared reflectance and thermal imaging were shown to be very effective in grading of peanut with pod.

  • PDF

A Review of the Domestic Study Trends on Obstetrics & Gynecological Diseases by Using Digital Infrared Thermal Imaging as a Diagnosis Instrument (한방여성의학 영역에서 진단 도구로 적외선 체열 검사(Digital Infrared Thermal Imaging, DITI)를 활용한 국내 연구 동향 분석)

  • Im, Ji-Yeong;Hwang, Deok-Sang;Lee, Jin-Moo;Lee, Chang-Hoon;Jang, Jun-Bock
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.33 no.3
    • /
    • pp.80-94
    • /
    • 2020
  • Objectives: The purpose of this review is to analyze the domestic study trends of clinical use of Digital Infrared Thermal Imaging (DITI) as a diagnosis instrument on obstetrics and gynecological diseases in Korean literature. Methods: We searched for clinical studies using DITI in the journal of Korean obstetrics & gynecology, National Digital Science Library, Research Information Sharing Service, Korean Medical Database up to May 2020. After searching studies, we selected studies and analyzed according to disease. Results: 18 clinical studies were published in two kinds of academic journals. There were 4 studies about dysmenorrhea and menopausal symptoms, 2 studies about postpartum disease and hypercryalgesia, 1 study about amenorrhea, premenstrual syndrome, leukorrhea, infertility, polycystic ovary syndrome and hot flush. Conception vessel was frequently used for DITI measurement, followed by stomach meridian. The temperatures of abdomen (CV4, CV12), face (HN3), upper and lower limb (PC8, LU4, LR3, ST32) were commonly measured. Conclusions: This study shows that DITI could be one of effective diagnosis instrument for obstetrics and gynecological diseases. More well-designed clinical studies using DITI will be needed.

Alteration in Infrared Thermal Imaging by Use of Acupuncture-like Electric Stimulation on Finger Control Gate (체열촬영으로 관찰한 전기수지자극의 효과)

  • Lee, Sang-Hun;Lee, Kyu-Chang;Woo, Nam-Sik;Lee, Ye-Chul;Kim, Sun-Bok;Lee, Hyung-Hoan
    • The Korean Journal of Pain
    • /
    • v.7 no.2
    • /
    • pp.222-230
    • /
    • 1994
  • Acupuncture-like transcutaneous electrical nerve stimulation(ALTENS) on acupuncture site(dorsal and ventral side of finger) were compared with a placebo site(forearm) by infrared thermal imaging. Six disease-free volunteers underwent, on different days, an ALTENS treatment and a placebo treatment in a cross-over sequences of stimulation control and inhibition control in excess of 50 treatments. ALTENS treatments were given at 30Hz at an intensity just below pain threshold delivered to acupuncture points on fingers. Placebo stimulations were administered in similar manner. After every thirty minutes of ALTENS and placebo treatment with stimulation, inhibition control sequence and vice versa, we examined whole body infrared thermal imaging and checked changed skin temperature on frontal, anterior chest, upper and lower abdomen, dorsal and ventral aspect of hand, thoracic and lumbar area, anterior and posterior aspect of lower leg. There were significant skin temperature elevations with ALTENS treatment, especially finger control gate corresponding organ area. Placebo treatment revealed no skin temperature change. We concluded that ALTENS on finger control gate influence physiologic state as opposed to conventional electric stimulation.

  • PDF

Design of Two Zoom Infrared Camels using Noise Uniformity Correction by Shutter Lens (셔터렌즈에 의한 검출기 불균일 보정을 적용한 이중배율 적외선 카메라 설계)

  • Ahn, Gyou-Bong;Kim, Seo-Hyun;Jung, Jae-Chul;Jo, Mun-Shin;Kim, Chang-Woo;Kim, Hyun-Sook
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.2
    • /
    • pp.135-141
    • /
    • 2007
  • This paper describes the design technology for a third generation thermal imaging system, which is more compact than before, using a $320\times240$ mid-IR focal plane detector. The third generation non-scanning thermal imaging system was constructed as a compact thermal imaging module as a reconnaissance, surveillance and navigation sensor for helicopter and infantry vehicles in the $1980's\sim1990's$ and now, we designed a new compact infrared camera and studied a new type of non-uniformity correction lens fer this camera.