• Title/Summary/Keyword: Infrared Technology

검색결과 1,997건 처리시간 0.026초

Wide-Tunable Mid Infrared Intra-cavity Optical Parametric Oscillator Based on Multi-period MgO:PPLN

  • Wang, Xiao-Chan;Wang, Yu-Heng;Zheng, Hao;Liu, Hong-Zhi;Yu, Yong-Ji;Wang, Zi-Jian
    • Current Optics and Photonics
    • /
    • 제5권1호
    • /
    • pp.59-65
    • /
    • 2021
  • This paper reports a tunable diode-pumped folded intracavity Q-switched singly resonant optical parametric oscillator based on multi-period MgO:PPLN. A wide tuning mid-infrared parametric light from 2.78 ㎛ to 4.17 ㎛ was obtained in real time by changing the poled periods and temperatures. The maximum output power of 1.89 W at 3.2 ㎛, 1.53 W at 3.5 ㎛, 0.87 W at 3.8 ㎛ and 0.486 W at 4.1 ㎛ were achieved. The highest optical-optical conversion efficiency was 7.89%. During experiments, a range tunable output of 2.78-4.17 ㎛ in the mid-infrared range was achieved.

유도가열 및 근적외선 가열방법에 의한 표면처리 강판 도포층의 가열 및 건조 특성 (Heating & Drying Characteristics of Coating Layer by Induction Heating and Short-wave Infrared Heating)

  • 김태수;양재원
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2004년도 제5회 압연심포지엄 신 시장 개척을 위한 압연기술
    • /
    • pp.249-257
    • /
    • 2004
  • Drying and curing characteristics of PCM resins using the induction heater and short-wave infrared emitter module was studied to develop a compact oven system for the high speed CCL and post-treatment equipment. Drying of the polyester resins using the induction heater and infrared heater showed that the blistering tendency of polyester resin coating increased regardless of additives and colors of resins as the heating rate and/or dry film thickness increased. The blistering of polyester resin coating layer occurred when the heating speed was over than $25^{\circ}C/sec$ for the dry film thickness of $19\~20um$, which is the typical thickness of finish coating in CCL. So did it when the heating speed was over than $40^{\circ}C/sec$ for the dry film thickness over than 10 um. The heating efficiency of paint coated steels by the infrared heating was strongly dependent on the colors of paint coating and generally increased for the dark surface and/or coating. But the faster drying of the PCM resin coatings increased the blistering tendency of coating layer. The blistering limit for the typical finish coating by the infrared heating was estimated as the heating rate slower than $20^{\circ}C/sec$ regardless of colors of PCM resins.

  • PDF

개발한 진단용 다엽조리개 성능평가 및 X선영상과 적외선체열영상의 융합영상 구현 (Performance Evaluation of the Developed Diagnostic Multi-Leaf Collimator and Implementation of Fusion Image of X-ray Image and Infrared Thermography Image)

  • 권순무;심재구;천권수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권5호
    • /
    • pp.365-371
    • /
    • 2019
  • We have developed and applied a diagnostic Multi-Leaf Collimator (MLC) to optimized the X-ray field in medical imaging and the usefulness evaluated through the fusion of infrared image and X-ray image acquired by infrared camera. The hand and skull radiography with multi-leaf collimator(MLC) showed significant area dose reductions of 22.9% and 31.3% compared to ARC and leakage dose was compliant with KS A 4732. Also scattering doses of 50 cm and 100 cm showed a significant decrease to confirm the usefulness of MLC. It was confirmed that the fusion of infrared images with an adjustable degree of transparency was possible in the X-ray images. Therefore, fusion of anatomical information with physiological convergence is expected to contribute and improvement of diagnostic ability. In addition, the feasibility of convergence X-ray imaging and DITI devices and the possibility of driving MLC with infrared images were confirmed.

A Comparison of Standardization Methods in Near-infrared Analysis

  • Ko, Young-Hyun;Park, Kwang-Su;Lee, Hye-Seon;Jun, Chi-Hyuck;Ku, Min-Sik;Chung, Hoe-Il
    • Near Infrared Analysis
    • /
    • 제1권1호
    • /
    • pp.9-17
    • /
    • 2000
  • A variety of standardization methods between two near-infrared (NIR) spectrometers were investigated for the prediction of five constituents in trans-alkylation process. Spectra were collected by two different instruments (one is regarded as mater instrument, other on as slave instrument). Three well-known standardization methods of direct standardization (DS), piecewise direct standardization (PDS) and slope/bias correction of response variable were applied to trans-alkylation samples on the slave instrument. We have examined for a set of reliable standardization samples using smaller number of transfer samples in order to increase efficiency of standardization.

Formaldehyde Deodorization Effect and Far-Infrared Emission Characteristics of Ceramics Prepared with Sawdust, Risk Husk, and Charcoal: Effect of Material Mixing Ratio

  • HWANG, Jung-Woo;OH, Seung-Won
    • Journal of the Korean Wood Science and Technology
    • /
    • 제50권2호
    • /
    • pp.104-112
    • /
    • 2022
  • Indoor air quality is a very important environmental factor in modern society. However, air pollutants generated from various interior construction materials significantly affect the human body, including formaldehyde (HCHO) and volatile organic compounds that threaten public health by deteriorating indoor air quality. Effective in removing these harmful substances are porous materials, such as woodceramics. In this study, charcoal, a porous material, was added to rice husk, an agricultural by-product, and sawdust generated during the sawing process to prepare boards and ceramics at different mixing ratios, and the HCHO deodorization performance and far-infrared emission characteristics were measured. As the mixing ratio of charcoal increased, the deodorization rate of the boards and ceramics tended to increase. Overall, the deodorization rate was measured to be 80% to 90%, indicating that the boards and ceramics prepared with charcoal are suitable to be used for the purpose of deodorization. The effect of the material mixing ratio on far-infrared emissivity and emission power was insignificant.

산삼배양근의 원적외선 건조특성 (Far Infrared Rays Drying Characteristics of Tissue Cultured Mountain Ginseng Roots)

  • 리혁;강태환;녕효봉;조성찬;한충수
    • Journal of Biosystems Engineering
    • /
    • 제34권3호
    • /
    • pp.175-182
    • /
    • 2009
  • This study was conducted to investigate the drying characteristics of tissue cultured mountain ginseng roots. The far infrared rays dryer of a double blast system used for this experiment can control the drying parameters such as far infrared heater temperature and air velocity. The far infrared rays drying tests of tissue cultured mountain ginseng roots were performed at air velocity of 0.4, 0.6, 0.8 m/s, under drying air temperature of 50, 60, and $70^{circ}C$, respectively. The results were compared with one obtained by the heated air drying method. The drying characteristics such as drying rate, color, energy consumption, saponin components and antioxidant activities were analyzed. The results showed that the drying rate of far infrared rays drying was faster than that of heated air drying and due to high temperature of drying air and fast air velocity, the far infrared rays drying of double blast type was superior to the heated air drying. The value of the color difference for heated air drying was 10.11${\sim}$12.99 and that of far infrared rays drying was in the range of 7.05${\sim}$7.54, which was in the same drying condition, also energy consumption of far infrared rays drying was in the range of 3575${\sim}$6898 kJ/kg-water. At the same time, the antioxidant activities using far infrared rays drying were higher than those using heated air drying.

히스토그램 분할 펼침과 축소 방법을 이용한 적외선 영상 개선 (Infrared Image Enhancement Using A Histogram Partition Stretching and Shrinking Method)

  • 정민철
    • 반도체디스플레이기술학회지
    • /
    • 제14권4호
    • /
    • pp.50-55
    • /
    • 2015
  • This paper proposes a new histogram partition stretching and shrinking method for infrared image enhancement. The proposed method divides the histogram of an input image into three partitions according to its mean value and standard deviation. The method stretches both the dark partition and the bright partition of the histogram, while it shrinks the medium partition. As the result, both the dark part and the bright part of the image have more brightness levels. The proposed method is implemented using C language in an embedded Linux system for a high-speed real-time image processing. Experiments were conducted by using various infrared images. The results show that the proposed algorithm is successful for the infrared image enhancement.

가변 파장형 적외선 가스 센서에 의한 생체표지자 분석 (Analysis of biomarkers with tunable infrared gas sensors)

  • 이승환
    • 센서학회지
    • /
    • 제30권5호
    • /
    • pp.314-319
    • /
    • 2021
  • In this study, biomarkers were analyzed and segmented using tunable infrared gas sensors after performing the principal component analysis. The free spectral range of the device under test (DUT) was around 30 nm and DUT-5580 yielded the highest output voltage property among the others. The biomarkers (isoprophyl alcohol, ethanol, methanol, and acetone solutions) were sequentially mixed with deionized water and their mists were carried into the gas chamber using high-purity nitrogen gas. A total of 17 different mixed gases were tested with three tunable infrared gas sensors, namely DUT-3144, DUT-5580, and DUT-8010. DUT-8010 resolved the infrared absorption spectra of whole mixed gases. Based on the principal component analysis with each DUT and their combinations, each mixed gas and the trends in increasing gas concentration could be well analyzed when the contributions of the eigenvalues of the first and second were higher than 70% and 10%, respectively, and their sum was greater than 90%.

적외선 열화상 이미지 컨트라스트 파라미터를 이용한 결함 크기의 비파괴 평가 (Nondestructive Evaluation of Defect Size by Using a Contrast Parameter of Infrared Image)

  • 최정영;최수용;김재연;유기태;박재원;현창용;변재원
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제18권1호
    • /
    • pp.87-94
    • /
    • 2018
  • Purpose: In this study, the defect quantification of thin metal plate was evaluated by using lock-in infrared thermography. Methods: A STS304 standard specimens, which had the artificial-defects of different size, were used. The focal distance between the infrared camera and the specimen was set to 500mm, and the distance between the lump and the specimen was set to 200mm. One halogen lamp with a maximum capacity of 1kW was used, and phase-lock infrared thermal images with a frequency of 1Hz were captured and analyzed. Result: Objectively quantified data values were obtained by analyzing the contrast ratio and signal-to-noise ratio. Conclusion: The possibility of defect diagnosis for thin metal plate was confirmed by using the lock-in infrared thermography technique.

Characteristics of InGaAs/GaAs/AlGaAs Double Barrier Quantum Well Infrared Photodetectors

  • 박민수;김호성;양현덕;송진동;김상혁;윤예슬;최원준
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.324-325
    • /
    • 2014
  • Quantum wells infrared photodetectors (QWIPs) have been used to detect infrared radiations through the principle based on the localized stated in quantum wells (QWs) [1]. The mature III-V compound semiconductor technology used to fabricate these devices results in much lower costs, larger array sizes, higher pixel operability, and better uniformity than those achievable with competing technologies such as HgCdTe. Especially, GaAs/AlGaAs QWIPs have been extensively used for large focal plane arrays (FPAs) of infrared imaging system. However, the research efforts for increasing sensitivity and operating temperature of the QWIPs still have pursued. The modification of heterostructures [2] and the various fabrications for preventing polarization selection rule [3] were suggested. In order to enhance optical performances of the QWIPs, double barrier quantum well (DBQW) structures will be introduced as the absorption layers for the suggested QWIPs. The DBWQ structure is an adequate solution for photodetectors working in the mid-wavelength infrared (MWIR) region and broadens the responsivity spectrum [4]. In this study, InGaAs/GaAs/AlGaAs double barrier quantum well infrared photodetectors (DB-QWIPs) are successfully fabricated and characterized. The heterostructures of the InGaAs/GaAs/AlGaAs DB-QWIPs are grown by molecular beam epitaxy (MBE) system. Photoluminescence (PL) spectroscopy is used to examine the heterostructures of the InGaAs/GaAs/AlGaAs DB-QWIP. The mesa-type DB-QWIPs (Area : $2mm{\times}2mm$) are fabricated by conventional optical lithography and wet etching process and Ni/Ge/Au ohmic contacts were evaporated onto the top and bottom layers. The dark current are measured at different temperatures and the temperature and applied bias dependence of the intersubband photocurrents are studied by using Fourier transform infrared spectrometer (FTIR) system equipped with cryostat. The photovoltaic behavior of the DB-QWIPs can be observed up to 120 K due to the generated built-in electric field caused from the asymmetric heterostructures of the DB-QWIPs. The fabricated DB-QWIPs exhibit spectral photoresponses at wavelengths range from 3 to $7{\mu}m$. Grating structure formed on the window surface of the DB-QWIP will induce the enhancement of optical responses.

  • PDF