• Title/Summary/Keyword: Infrared Imaging

Search Result 769, Processing Time 0.023 seconds

The Cut Off Values for Diagnosing Hot flashes by Using Digital Infrared Thermographic Imaging (적외선 체열 촬영을 이용한 안면홍조 진단의 절단값 산정)

  • Jo, Jun-Young;Hwang, Deok-Sang;Lee, Chang-Hoon;Jang, Jun-Bock;Lee, Kyung-Sub;Lee, Jin-Moo
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.26 no.3
    • /
    • pp.85-92
    • /
    • 2013
  • Objectives: The purpose of this study is to find diagnostic points and define the cut off values of hot flashes by using digital infrared thermographic imaging. Methods: Thermographic images of 75 patients with hot flashes (HF, n=35) and non-hot flashes (NHF, n=40) were retrospectively reviewed. We used the temperature difference between Ex-HN3 and CV17, LU4, CV12, CV4 for diagnosing hot flashes. The temperature differences of between two groups were analysed using independent samples t-tests. The cut off values were calculated by received operating characteristic curve analysis. Analyses were undertaken using SPSS version 17.0. and p-value of <0.05 was considered significant. Results: The temperature difference Ex-HN3 and LU4 were the most significantly different between groups (p<0.001). Using receiver operating characteristic curve analysis, the sensitivity, specificity, and area under the curve were 65.7%, 72.5%, 0.729, respectively. The optimum cut off value was defined as $1.00^{\circ}C$. Conclusions: These results suggest that the digital infrared thermographic imaging is a reliable instrument for estimating hot flashes.

A Review of the Domestic Study Trends on Obstetrics & Gynecological Diseases by Using Digital Infrared Thermal Imaging as a Diagnosis Instrument (한방여성의학 영역에서 진단 도구로 적외선 체열 검사(Digital Infrared Thermal Imaging, DITI)를 활용한 국내 연구 동향 분석)

  • Im, Ji-Yeong;Hwang, Deok-Sang;Lee, Jin-Moo;Lee, Chang-Hoon;Jang, Jun-Bock
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.33 no.3
    • /
    • pp.80-94
    • /
    • 2020
  • Objectives: The purpose of this review is to analyze the domestic study trends of clinical use of Digital Infrared Thermal Imaging (DITI) as a diagnosis instrument on obstetrics and gynecological diseases in Korean literature. Methods: We searched for clinical studies using DITI in the journal of Korean obstetrics & gynecology, National Digital Science Library, Research Information Sharing Service, Korean Medical Database up to May 2020. After searching studies, we selected studies and analyzed according to disease. Results: 18 clinical studies were published in two kinds of academic journals. There were 4 studies about dysmenorrhea and menopausal symptoms, 2 studies about postpartum disease and hypercryalgesia, 1 study about amenorrhea, premenstrual syndrome, leukorrhea, infertility, polycystic ovary syndrome and hot flush. Conception vessel was frequently used for DITI measurement, followed by stomach meridian. The temperatures of abdomen (CV4, CV12), face (HN3), upper and lower limb (PC8, LU4, LR3, ST32) were commonly measured. Conclusions: This study shows that DITI could be one of effective diagnosis instrument for obstetrics and gynecological diseases. More well-designed clinical studies using DITI will be needed.

Alteration in Infrared Thermal Imaging by Use of Acupuncture-like Electric Stimulation on Finger Control Gate (체열촬영으로 관찰한 전기수지자극의 효과)

  • Lee, Sang-Hun;Lee, Kyu-Chang;Woo, Nam-Sik;Lee, Ye-Chul;Kim, Sun-Bok;Lee, Hyung-Hoan
    • The Korean Journal of Pain
    • /
    • v.7 no.2
    • /
    • pp.222-230
    • /
    • 1994
  • Acupuncture-like transcutaneous electrical nerve stimulation(ALTENS) on acupuncture site(dorsal and ventral side of finger) were compared with a placebo site(forearm) by infrared thermal imaging. Six disease-free volunteers underwent, on different days, an ALTENS treatment and a placebo treatment in a cross-over sequences of stimulation control and inhibition control in excess of 50 treatments. ALTENS treatments were given at 30Hz at an intensity just below pain threshold delivered to acupuncture points on fingers. Placebo stimulations were administered in similar manner. After every thirty minutes of ALTENS and placebo treatment with stimulation, inhibition control sequence and vice versa, we examined whole body infrared thermal imaging and checked changed skin temperature on frontal, anterior chest, upper and lower abdomen, dorsal and ventral aspect of hand, thoracic and lumbar area, anterior and posterior aspect of lower leg. There were significant skin temperature elevations with ALTENS treatment, especially finger control gate corresponding organ area. Placebo treatment revealed no skin temperature change. We concluded that ALTENS on finger control gate influence physiologic state as opposed to conventional electric stimulation.

  • PDF

Transmission Characteristics of Indoor Infrared Diffuse Links Employing Three-Beam Optical Transmitters and Non-Imaging Receivers

  • Wang, Zan;Pan, Jae-Kyung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.12A
    • /
    • pp.1251-1260
    • /
    • 2008
  • Diffuse wireless optical communication offers more robust optical links in terms of coverage and shadowing than line-of-sight links. However, traditional diffuse wireless infrared (IR) transceiver systems are more susceptible to multi-path distortion and great power decrease, which results in limiting high-speed performance. Multi-beam is an effective technique to compensate for multi-path distortion in a wireless infrared environment. The goal of this paper is to analyze the transmission characteristics by replacing traditional diffuse system (TDS) which contains single wide angle transmitter and single element receiver by system consisting of three-beam transmitter and non-imaging receiver (TNS) attached with compound parabolic concentrator (CPC). In the simulation, we use the recursive model developed by Barry and Kahn and build the scenario based on 10 different cases which have been listed in Table 1. Moreover, we also check the reliability of the TNS diffuse link channel by BER test on the basis of different receiver positions and room sizes. The simulation results not only show the basic transmission characteristics of TNS diffuse link, but also are references to design more efficient and reliable indoor infrared transmission systems.

A Simple Design of an Imaging System for Accurate Spatial Mapping of Blood Oxygen Saturation Using a Single Element of Multi-wavelength LED (혈중 산소 포화도의 정확한 공간 매핑을 위한 다중 파장 LED 단일소자를 활용한 이미징 시스템 설계)

  • Jun Hwan Kim;Gi Yeon Yu;Ye Eun Song;Chan Yeong Yu;Yun Chae Jang;Riaz Muhammad;Kay Thwe Htun;Ahmed Ali;Seung Ho Choi
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.6
    • /
    • pp.450-464
    • /
    • 2023
  • Pulse oximetry, a non-invasive technique for evaluating blood oxygen saturation, conventionally depends on isolated measurements, rendering it vulnerable to factors like illumination profile, spatial blood flow fluctuations, and skin pigmentation. Previous efforts to address these issues through imaging systems often employed red and near-infrared illuminations with distinct profiles, leading to inconsistent ratios of transmitted light and the potential for errors in calculating spatial oxygen saturation distributions. While an integrating sphere was recently utilized as an illumination source to achieve uniform red and near-infrared illumination profiles on the sample surface, its bulkiness presented practical challenges. In this work, we have enhanced the pulse oximetry imaging system by transitioning illumination from an integrating sphere to a multi-wavelength LED configuration. This adjustment ensures simultaneous emission of red and near-infrared light from the same position, creating a homogeneous illumination profile on the sample surface. This approach guarantees consistent patterns of red and near-infrared illuminations that are spatially uniform. The sustained ratio between transmitted red and near-infrared light across space enables precise calculation of the spatial distribution of oxygen saturation, making our pulse oximetry imaging system more compact and portable without compromising accuracy. Our work significantly contributes to obtaining spatial information on blood oxygen saturation, providing valuable insights into tissue oxygenation in peripheral regions.

Temperature Measurement of Photovoltaic Modules Using Non-Contact Infrared System

  • Jovanovic, Ugljesa;Mancic, Dragan;Jovanovic, Igor;Petrusic, Zoran
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.904-910
    • /
    • 2017
  • This paper presents temperature measurement of solar photovoltaic modules using the custom-made system composed of an infrared temperature sensor and a microcontroller. The obtained measurement results are processed, displayed and stored on a PC using the custom-made virtual instrument. The proposed system overcomes some of the problems related to the contact sensor application, and at the same time offers accurate readings and better flexibility. The proposed system is especially suitable for applications where the cost is a limiting factor in the choice of measuring system. The conducted analysis and the obtained results have shown an excellent accuracy of the proposed system in comparison to a high quality thermal imaging camera used as the reference instrument.

FACTORS INVOLVED IN DEVELOPMENT OF ELECTRONIC SYSTEMS FOR GRADING GRAINS AND SEEDS

  • Williams, Phil
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.3121-3121
    • /
    • 2001
  • The factors involved in development of electronic grading systems for commodities such as grains and seeds include determination of the factors that influence the end-product utilization of the commodities, and the degree to which these can be predicted by electronic methods. The possibility of exchanging existing methods of grading by electronic methods has to be considered. The respective merits of techniques such as Digital Imaging and Near-infrared (NIR) spectroscopy have to be considered. Digital Imaging is a computerized version of visual inspection and grading, whereas NIR spectroscopy has the potential for grading on the basis of composition and functionality, Selection and evaluation of NIR instruments is an important factor, as are sampling and sample presentation to electronic instruments, and particularly the engineering involved in sample presentation. Sample assembly, and software for calibration development are described in the presentation. Finally the impact and implications of introduction of electronic grading are discussed with particular attention to marketing of the commodities.

  • PDF

A Study on the Effectiveness of Heat Infrared Imaging Method for Monitoring the Physical Condition of the Mortar Walls

  • Yoshioka Ryouhei;Tachiiri Kaoru;Asari Kimihiro;Gotoh Keinosuke
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.545-548
    • /
    • 2004
  • In Japan for protecting the slides of steep sloped areas covering the face of slopes by sprayed mortar became popular since 1970s. But, these mortar walls are getting older now. In this background, this study aims to find ways to develop a diagnostic technique of these faces of slope without physically contacting or destroying them. In doing so, we have used heat infrared imaging processing method and developed a simulation model to predict the weak portion of the wall. The results revealed that, by following the model vacuum of mortar wall can be detected having thickness up to 15cm.

  • PDF

Airborne Infrared Scanning Imaging System with Rotating Drum for Fire Detection

  • Song, c;Chang, Jun;Cao, Jiao;Zhang, Lifei;Wen, Yao;Wei, Aman;Li, Jiang
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.340-344
    • /
    • 2011
  • Airborne infrared techniques have been used in wild land fire management for decades. This paper describes a kind of infrared scanning system based on a rotating drum with a tilted porthole underside the plane nose. This design increases the stability of the mechanism system, reduces air resistance and protects inner parts. Aberration characteristics of a tilted ellipsoid porthole are analyzed and an effective solution is invented which makes the system achieve $30^{\circ}$ field of regard. The system's ultimate value of modulation transfer function is near the diffraction limit, which indicates that the performance of the rotating optical system meets the imaging requirements.

An Vision System for Automatic Detection of Vehicle Passenger (차량 승객 자동탐지를 위한 비젼시스템)

  • Lee Young-Sik;Bae Cheol-Soo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.3
    • /
    • pp.622-626
    • /
    • 2005
  • This paper presents an active vision system for ITS(intelligent transportation system : ITS). We have described a novel method to provide high quality imaging signals to a system that will perform passenger detection and counting in the roadway. The method calls for two co-registered near-infrared cameras with spectral sensitivity above (upper-band) and below (lower-band) the quality of the signal remains. We propose a novel system based on fusion of near-infrared imaging signals and we demonstrate its adequacy with theoretical and experimental arguments.