• Title/Summary/Keyword: Infrared(IR)

Search Result 1,561, Processing Time 0.03 seconds

Analysis of Gas Cooling System for IR Window (적외선 윈도우용 가스식 냉각장치 해석 기법)

  • Hyun, Cheol-Bong;Goo, Nam-Seo;Kim, Jae-Young;Lee, Ho-Sung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.130-137
    • /
    • 2012
  • In this paper, a post-analysis of cooling system for infrared(IR) window was performed based on heating experiment of IR window system. We applied the same experimental conditions to analysis, and then validated the analysis technique by comparing numerical and experimental results. For an analysis software, we used a professional heat/fluid analysis program and the numerical and experimental results were in fairly good agreement. We investigated the effect of thermal transfer between the frame and IR window and also a cooling efficiency between fluid and structure in order to determine the proper parameters for the analysis. In this study, 100 % thermal transfer between the frame and IR window and 30 % cooling efficiency between fluid and structure have been proposed, which can be used in the future conceptual design and analysis of similar IR windows.

Preparation and Characterization of Dinuclear Metal Complexes, $[(PPh_3)_2(CO)M({\mu}-E)M(CO)(PPh_3)_2](SO_3CF_3)_2$ (M = Rh, Ir; E = 1,4-Dicyanobenzene and 1,4-Dicyano-2-butene)

  • Moonsik Kim;JaeKyun Chin;Jaejung Ko
    • Bulletin of the Korean Chemical Society
    • /
    • v.13 no.5
    • /
    • pp.556-559
    • /
    • 1992
  • Hydrocarbon solution of $(PPh_3)_2(CO)MOSO_2CF_3$ (M= Rh, Ir) reacts rapidly with 1,4-dicyanobenzene or 1,4-dicyano-2-butene to yield dinuclear metal complexes $[(PPh_3)_2(CO)M({\mu}-dicyanobenzene)M(CO)(PPh_3)_2](SO_3CF_3)_2$ (I: M = Rh; II: M = Ir) or $[(PPh_3)_2(CO)M({\mu}-dicyano-2-benzene)M(CO)(PPh_3)_2](SO_3CF_3)_2$ (III: M = Rh; IV: M = Ir), respectively. Compounds I, II, III, and IV were characterized by $^1H$-NMR, $^{31}P$-NMR, and infrared spectrum. Dichloromethane solution of II and IV reacts with $H_2\;and\;I_2$ to yield oxidative addition complexes $[(PPh_3)_2(CO)IrX_2({\mu}-E)X_2Ir(CO)(PPh_3)_2](SO_3CF_3)_2$ (V; E = 1,4-dicyanobenzene, $X_2$ = $H_2$; VI : E = 1,4-dicyano-2-butene, $X_2$ = $H_2$; VII; E = 1,4-dicyanobenzene, $X_2$ = $I_2$). All metal complexes are bridged by the cyanide groups. Compounds Ⅴ, Ⅵ, and Ⅶ are characterized by conventional methods.

Statistical Model of 3D Positions in Tracking Fast Objects Using IR Stereo Camera (적외선 스테레오 카메라를 이용한 고속 이동객체의 위치에 대한 확률모델)

  • Oh, Jun Ho;Lee, Sang Hwa;Lee, Boo Hwan;Park, Jong-Il
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.1
    • /
    • pp.89-101
    • /
    • 2015
  • This paper proposes a statistical model of 3-D positions when tracking moving targets using the uncooled infrared (IR) stereo camera system. The proposed model is derived from two errors. One is the position error which is caused by the sampling pixels in the digital image. The other is the timing jitter which results from the irregular capture-timing in the infrared cameras. The capture-timing in the IR camera is measured using the jitter meter designed in this paper, and the observed jitters are statistically modeled as Gaussian distribution. This paper derives an integrated probability distribution by combining jitter error with pixel position error. The combined error is modeled as the convolution of two error distributions. To verify the proposed statistical position error model, this paper has some experiments in tracking moving objects with IR stereo camera. The 3-D positions of object are accurately measured by the trajectory scanner, and 3-D positions are also estimated by stereo matching from IR stereo camera system. According to the experiments, the positions of moving object are estimated within the statistically reliable range which is derived by convolution of two probability models of pixel position error and timing jitter respectively. It is expected that the proposed statistical model can be applied to estimate the uncertain 3-D positions of moving objects in the diverse fields.

A STUDY OF THERMAL ANALYSIS OF KAONICS (적외선 카메라 KAONICS의 열해석)

  • Kang, Ji-Na;Lee, Sung-Ho;Jin, Ho;Park, Soo-Jong;Moon, Bong-Kon;Kim, Sang-Ho;Park, Jang-Hyun
    • Journal of Astronomy and Space Sciences
    • /
    • v.21 no.4
    • /
    • pp.467-480
    • /
    • 2004
  • It is very important to eliminate thermal background radiation for the near infrared camera system such as KAONICS (KAO Near Infrared Camera System). Thermal background radiations which come from window and cryostat wall influence IR detector and decrease IR system performance. Therefore the cold box which contains optics and detector housing must be cooled down to eliminate thermal background radiation. We carried out quantitative analysis to determine internal cooling temperature to reduce thermal noise in the J, H, Ks, and L bandpass. Additionally, we estimated the incoming heat load and then chose the cryocooler adequate to KAONICS's requirements. The cooling time and the final cooling temperature of the cold box were calculated. These results were also implemented to the system design.

Analysis of Dark Data of the PICNIC IR Arrays in the CIBER

  • Lee, D.H.;Kim, M.G.;Tsumura, K.;Zemcov, M.;Nam, U.W.;Bock, J.;Battle, J.;Hristov, V.;Renbarger, T.;Matsumoto, T.;Sullivan, I.;Levenson, L.R.;Mason, P.;Matsuura, S.;Kim, G.H.
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.4
    • /
    • pp.401-406
    • /
    • 2010
  • We have measured and analyzed the dark data of two PICNIC IR arrays (P574 and P560) obtained through the Cosmic Infrared Background ExpeRiment (CIBER). First, we identified three types of bad pixels: the cold, the hot, and the transient, which are figured in total as 0.06% for P574 and 0.19% for P560. Then, after the bad pixels were masked, we determined the dark noise to be 20.5 ${\pm}$ 0.05 $e^-$ and 16.1 ${\pm}$ 0.05 $e^-$, and the dark current to be 0.6 ${\pm}$ 0.05 $e^-$/sec and 0.7 ${\pm}$ 0.05 $e^-$/sec for P574 and P560, respectively. Finally, we discussed glitches and readout modes for a future mission.

Temperature Dependency of Non-dispersive Infrared Carbon Dioxide Gas Sensor by Using White-Cell Structure (White-Cell 구조를 응용한 비분산 적외선 이산화탄소 센서의 온도특성)

  • Yi, SeungHwan;Park, YoungHwan;Lee, JaeKyung
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.5
    • /
    • pp.377-381
    • /
    • 2016
  • NDIR $CO_2$ gas sensor was prototyped with ASIC implemented thermopile sensor which included temperature sensor and White-Cell structure in this paper. The temperature dependency of dual infrared sensors ($CO_2$ and reference IR sensors) has been characterized and their output voltage ratios according to the temperature and gas concentration were presented in this paper for achieving temperature compensation algorithm. The initial output voltages of NDIR $CO_2$ gas and reference IR sensors showed $3^{rd}$ order polynomial and linear output voltages according to the variation of ambient temperatures from 253 K to 333 K, respectively. The output voltages of temperature sensor presented a linear dependency according to the ambient temperature and could be described with V(T) = -3.0069+0.0145T(V). The characteristics of output voltage ratios could be modeled with five parameters which are dependent upon the ambient temperatures and gas concentration. The estimated $CO_2$ concentrations showed relatively high error below 300 ppm (maximum 572 % at 7 ppm $CO_2$ concentration), however, as the concentration increased from 500 ppm to 2,000 ppm, the overall estimated errors of $CO_2$ concentrations were less than ${\pm}10%$ in this research.

IR Camera Technique Application for Evaluation of Gas Turbine Blades Covering Integrity (가스터빈의 코팅층 건정성 평가를 위한 적외선 열화상 카메라 기법 활용)

  • Kim J.Y.;Yang D.J.;Choi C.J.;Park S.G.;Ahn Y.S.;Jeong G.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.192-196
    • /
    • 2005
  • Key part of main equipment in a gas turbine may be likely to be damaged due to operation under high temperature, high pressure, high-speed rotation, etc. Accordingly, the cost for maintenance increases and the damaged parts may cause generation to stop. The number of parts for maintenance also increases, but diagnostics technology fur the maintenance actually does not catch up with the demand. Blades are made of precipitation hardening Ni superalloy IN738 and the like for keeping hot strength. The surface of a blade is thermal-sprayed, using powder with main compositions such as Ni, Cr, Al, etc. in order to inhibit hot oxidation. Conventional regular maintenance of the coating layer of a blade is made by FPI (Fluorescent Penetrant Inspection) and MTP (Magnetic Particle Testing). Such methods, however, are complicated and take long time and also require much cost. In this study, defect diagnostics were tested for the coating layer of an industrial gas turbine blade, using an infraredthermography camera. Since the infrared thermography method can check a temperature distribution on a wide range of area by means of non-contact, it can advantageously save expenses and time as compared to conventional test methods. For the infrared thermography method, however, thermo-load must be applied onto a tested specimen and it is difficult to quantify the measured data. To solve the problems, this essay includes description about producing a specimen of a gas turbine blade (bucket), applying thermo-load onto the produced specimen, photographing thermography images by an infrared thermography camera, analyzing the thermography images, and pre-testing for analyzing defects on the coating layer of the gas turbine blade.

  • PDF

A Method for Observation of Benign, Premalignant and Malignant Changes in Clinical Skin Tissue Samples via FT -IR Microspectroscopy

  • Skrebova, Natalja;Aizawa, Katsuo;Ozaki, Yukihiro;Arase, Seiji
    • Journal of Photoscience
    • /
    • v.9 no.2
    • /
    • pp.457-459
    • /
    • 2002
  • Sunlight causes various types of adverse skin changes on the sun-exposed areas of the skin, in which the most hazardous one is the induction of malignant skin tumours. FT -IR spectra were obtained from specimens excised from normal skin, BCCs, SCCs, MMs, nevi, lesions of solar keratosis and Bowen's disease. Tissue samples from freshly frozen specimens were cut into 2 sections in strictly sequential order to be stained with H & E for histopathological analysis, and then to be air-dried on CaF$_2$ slide glasses for further spectral data acquisition from defined area of interest. Intra- and inter-sample variations were estimated within grouped lesion categories according to each skin component. Mean spectra for each type of tissue pathology in the 800-1800 $cm^{-1}$ / region was interpreted using the classical group frequency approach that showed the most visible differences in spectra of benign, premalignant and malignant changes directly related to protein conformation and nucleic acid bases. The relative intensity of the nucleic acid peak was increased with progression to malignancy. In addition, PCA was able to evaluate and maximise the differences in the spectra by reducing the number of variables characterizing each patient and pathology category. This type of approach to non-destructively estimate the complexity of IR-spectra of inhomogeneous samples such as skin demonstrates the advantage of FT -IR microspectroscopy to be able to observe diseased states (benign, premalignant, malignant) and distinguish them from normal against a huge background of inter- and intra-subject variability.

  • PDF

EFFECT OF WATER CONTENT ON THE FLEXURAL STRENGTH DURING REFIRING IN DENIAL PORCELAIN (치과용 도재의 재소성 과정중 수분 함량이 강도에 미치는 영향)

  • Park Hye-Yang;Shim June-Sung;Lee Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.5
    • /
    • pp.656-673
    • /
    • 2003
  • Statement of problem : Long-term exposure of dental porcelain to saliva during temporary cementation of a porcelain-fused to metal (PFM) restoration could affect mechanical strength of dental porcelain if the restoration is refired. Purpose : This work was performed to verify the effect of water on the mechanical strength in aged dental porcelain. Material and method : 63 specimens(Vintage Metalbond opaque and opal powder) were distributed to three experimental groups ; non-water immersed control, immersed and pedried, and immersed and non-predired groups. The changes in flexural strength and fracture toughness after specimen refiring related to Fourier Transform Infrared (FT-IR) spectroscopy. Results : 1. The FT-IR reflectances assigned to molecular bonds of $H_2O$ were noted as significantly different between the first-fired group and three refired groups and between two water-immersed groups and control group after refiring(p<0.05). They were also significantly different between predried group and non-predried group after refiring(p<0.05) 2. For opal specimens, FT-IR absorbances for hydrogen bond of $H_2O$ and silanols were significantly higher in non-predried group than in predreid group(p<0.05). 3 Predried opal group showed the highest mean flexural strength(p<0.05). Non-predried group indicated higher mean flexural strength than control group(p<0.05). 4. The mean fracture toughness for predired group was higher than non-predried group(p<0.05). 5. The difference of leucite crystal size is noted between control group and water-immersed, predried group in scanning electron microscopic study(${\times}10000$).

Analysis of Lacquer and CNSL Using Infrared Spectrometer and Pyrolysis-GC/MS (적외선분광분석과 Py-GC/MS를 이용한 옻칠 및 캐슈칠도막 분석)

  • Choi, Jaewan;Kim, Soo-Chul
    • Journal of the Korean Wood Science and Technology
    • /
    • v.46 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • Nowadays, synthetic resin varnish such as cashew nut shell liquid (CNSL) is being used as well as traditional lacquer. The code of ethics states that material must be identical to the original when preserving cultural heritage. Therefore, lacquer should be used. However, problem is that even experts have difficulties differentiating lacquer and CNSL as they have similar components. Therefore, this study was carried out to identify the difference between lacquer and CNSL using IR and Py-GC/MS. As a result of IR, in lacquer, $720cm^{-1}$ peak was detected and in CNSL, $750cm^{-1}$, $720cm^{-1}$ and $700cm^{-1}$ peaks were detected. The results of Py-GC/MS detect benzene compounds and alkyl chains for both varnishes. However, hexanoic acid was detected from CNSL but not lacquer. Using these analytical methods, the differences between lacquer and CNSL can be identified on the scene. This is expected to be applied to the authentic conservation and restoration of lacquerware.