• Title/Summary/Keyword: Infra Red Thermometer

Search Result 11, Processing Time 0.025 seconds

Flap Monitoring by Infra-red Thermometer (적외선 고막 체온계를 이용한 피판감시)

  • Kirk, Insoo;Hong, Joon-Pio
    • Archives of Reconstructive Microsurgery
    • /
    • v.13 no.1
    • /
    • pp.82-85
    • /
    • 2004
  • Flap monitoring is important for flap salvage. Although there are many methods to observe the flap, practical methods mostly used are subjective methods. Recording flap surface temperature is one of the objective methods of flap monitoring. We used an infra-red thermometer to simplify monitoring of the flap temperature. 60 groin flaps of SD rats are used in the experiment. Artificial arterial or venous insufficiency was made and the surface temperature was checked and compared with body temperature. In the results, the temperature of the arterial clamped flaps was lower than that of body and the mean difference was $0.3^{\circ}C$ after 20 minutes of clamping. In the vein-clamped flaps, the mean decrease was $0.4^{\circ}C$ after 30 minutes of clamping. The all difference of the temperature between the flaps and body was statistically significant. Our results suggest that flap monitoring by infra-red thermometer is simple, useful and helpful to evaluate the flap status.

  • PDF

Comparison of Non-destructive Measuring Methods of Tomato Plant to Detect N, P and Ca Deficient Stresses (토마토 잎의 비파괴 계측에 의한 N, P, Ca 결핍 장해 진단법 비교)

  • 서상룡;류육성;정갑채;성제훈;이성희
    • Journal of Biosystems Engineering
    • /
    • v.25 no.6
    • /
    • pp.517-526
    • /
    • 2000
  • A series of experiments was conducted to evaluate the capability of detecting nutrimental deficient stress of N, P and Ca of a tomato plant using several fast and intact type physiological properties measuring devices - a chlorophyll content meter an infra-red thermometer to measure leaf temperature a chlorophyll fluorescence meter a porometer an optical spectrometer a multi-scan radiometer and a canopy analyzer. to detect N deficient stress a chlorophyll content meter a spectrometer and a multi-scan radiometer were useful and their possibility to detect was estimated as about 50%, 100% and 100% respectively. To detect P deficient stress the infra-red thermometer the porometer and the spectrometer proved their usefulness an their possibility to detect was estimated as about 70%, 70% and 70% respectively. To detect Ca deficient stress an thermometer a porometer a spectrometer and a multi-scan radiometer were useful and their possibility to detect was estimated as about 60%, 70%,80% and 100% respectively. The experiments resulted that use of a spectrometer and a multi-scan radiometer in combination with a chlorophyll content meter an infra-red thermometer and a porometer were desirable to distinguish the nutrimental stress tested in the study.

  • PDF

Research of Developing of Standards for Electronic Thermometers (전자식체온계 기준규격 개발 연구)

  • Kim, E.J.;Lee, M.J.;Lee, B.Y.;Park, K.G.;Kim, D.S.;Lee, I.S.;Park, H.D.;Jeong, H.K.
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.2
    • /
    • pp.123-128
    • /
    • 2010
  • The thermometers is widely used in diagnostic medical devices, and the safety and accurate performance of these devices are important in the diagnosis and monitoring of personal health. Especially, the accuracy of infra-red thermometer is highly emphasized. Here two typical thermometers are utilized for this purpose: the electronic thermometers measure body temperature by contacting to subject while infra-red thermometers measure by no contacting to subject. Therefore, the evaluating items of each thermometer are different, and the standard for each temperature is highly needed. But, there have been no international standards of each thermometer such as IEC. In this paper, we developed the standards of electronic and infra-red thermometer based on national standards such as KS, ASTM, EN, JIS and FDA guidance. The new standards focused on the safety and suitable performance for health care. This standards were applied to enact and revise the electronic medical device standards. So it can be applied to evaluate the safety and performance on technical file review. We predict that this standard will improve the quality of diagnostic medical devices (thermometers) and increase the international competitive power of domestic product.

Method for Measuring Mechanical Behaviors of Thin Films at High Temperature (고온에서 박막의 기계적 거동 측정 방법)

  • Lim, Sang-Chai;Joo, Jae-Hwang;Kang, Ki-Ju
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.1
    • /
    • pp.102-108
    • /
    • 2003
  • Recently, the authors have developed a new material test system fur thin film at the high temperature. It is so compact and precise with sub micron resolution that it seems to be a useful tool fur research of the oxide film growth, its mechanical behavior and failure mechanism. To this end. in this paper three methologies are described for in-situ monitoring of the displacement & strain and the temperature, the oxide thickness. These are the Laser Speckle analysis with digital image correlation technique, the two-color infra-red thermometer and the laser reflection interferometry respectively. The calibration results and some issues which should be addressed for practical application are presented.

Comparison of temperature measurements methods to investigate the causes of deformation of packaging materials during microwave heating (전자레인지의 가열조리 시 포장재의 열변형 원인 규명을 위한 온도 측정 방법 비교)

  • Yoon, Chan Suk;Lee, Hwa Shin;Pfeiffer, Thomas;Cho, Ah Reum;Moon, Sang Kwon;Lee, Keun Taik
    • Food Science and Preservation
    • /
    • v.23 no.3
    • /
    • pp.422-431
    • /
    • 2016
  • To investigate the causes of the thermal deformations of packaging materials when microwave-heating ready-to-eat sauce products packaged in stand-up pouches, patterns of temperature changes were determined using an infra-red thermal imaging camera, a thermo-sensitive tape, and a fiver-optic thermometer. The temperature distributions of spicy chicken sauce and Indian curry samples in a stand-up pouch were found to be uneven during micrewave heating. A sharp increase in the temperature was detected, especially above the filling layers and in the corners of sealing layers of the package. The temperature measurements using an infra-red thermal imaging camera are restricted to the surface, and therefore might underestimate the actual temperature. Using a thermo-sensitive tape, temperature up to $200^{\circ}C$ were measured in the spicy chicken sauce sample showing package deformation. When the temperature is measured using a fiber-optic thermometer, it is crucial to have precise sensor performance to accurately measure the temperature in a narrow hot-spot area of the package. In this experiment, the fiber-optic thermometer was attached to a GaAs crystal sensor, which obtained more sensitive and accurate temperature measurements than those by a convectional sensor.

The Effect of Paraffin Therapy on Release of pain and Range of motion with Joint Disease Patients (관절 질환의 통증과 가동력에 파라핀 치료가 미치는 효과)

  • Lee, Suk-Min;Kwon, Ki-Ja
    • Journal of Korean Physical Therapy Science
    • /
    • v.10 no.1
    • /
    • pp.130-139
    • /
    • 2003
  • This study was conducted in order to determine the effect of Paraffin Therapy on release of pain, skin temperature and range of motion with joint diseases. This study was performed on 42 patients with general joint diseases and 21 patients with degenerative joint diseases. All the subjects were randomly assigned to three groups with 21 each. The experiment had been done from June, 1. 2002 to September, 30. 2002, in two general hospitals and a social welfare center using Digital Thermometer Kane-May KM330 and VAS(visual analogue scale). Each pint was measured in terms of skin temperature, pain scale and ROM(range of motion). The results of the experiment are as follows : 1. In application of three different heat modalities (Paraffin bath, Infra red, Hydro pack) on the Knee, Ankle, Elbow pints of the subjects for 30 minutes, the elevation of skin temperature and the reduction of pain scale were found to be significantly different. When checked right after the 30 minutes' application, the Infra red resulted in a higher degree elevation of skin temperature than two other modalities, while Paraffin bath resulted in the highest degree of the elevation of skin temperature when it was checked one hour after the application was over. It means that Paraffin bath lasted longer than the other two modalities(F=14.691, p<.000). 2. With Paraffin bath application, pint pain was reduced significantly both in 30 minutes and one hour checks(F=20.675, p<.001). 3. In terms of ROM(range of motion) increase, didn't seem to have any significant differences in 30 minutes and one hour. The results suggest that Paraffin therapy be helpful in maximizing th effects on pint diseases. I strongly suggest that further studies be done on other pints and muscle diseases using Paraffin bath in different methods of applying the therapy.

  • PDF

Development of Diagnosis System for Intelligent High-Speed Micro-Machining and Evaluation of Micro-Machining Characteristics (고속.지능형 마이크로머시닝을 위한 진단시스템 및 특성평가)

  • 김흥배;이우영;최성주
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.993-998
    • /
    • 1997
  • The advanced technology of micro-machining is starting to penetrate our lives. This technology, with which it is possible to make micro-structures by means of processing on the order of nm (micrometer = 1/1,000 mm) or less, is realizing machines that were only part of our wildest imagination. However, the fact is that many issues remain in the quest for a variety of applications. With the advent of computing technologies, information technologies, and telecommunications technologies, we foresee the need for new approaches in design, process, and the use of materials, technologies, and people in a globalized manufacturing enterprise. A new thinking paradigm is needed to focus on quality of service on the products we design and manufacture. Factories in different regions need to be co-ordinated through use of the state-of-the-art information on productivity, diagnostics, and service evaluation of manufacturing systems could be shared among different locations and partners. In this research, We develope the internet based Diagnosis system for micro machining and evaluate its characteristics by using mechatronic sensor like Dynamometer, acoustic emission, Acceleration sensor, micro phone, vision, infra-red thermometer.

  • PDF

Black Body Design and Verification for Non-Uniformity Correction of Imaging Sensor and Uncertainty Analysis (영상센서의 비균일 응답특성 보정을 위한 흑체 설계 및 성능검증과 보정오차 분석)

  • Shin, Somin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.3
    • /
    • pp.240-245
    • /
    • 2013
  • Each pixel of InfraRed(IR) sensor differently responds to IR light as time elapses or the sensor on/off operation is repeated. As a result, the quality of IR sensor image is deteriorated, and therefore NUC(Non-uniformity Correction) is periodically needed for IR sensor. In this paper, in order to perform NUC in the Satellite, on-board V-grooved blackbody is designed with a baffle so that the emissivity of black body is to be higher than 0.995 as well as the temperature deviation is less than $1^{\circ}C$ in the range of the infrared wave length from 3.3 to $5.2{\mu}m$. To check its performance, the emissivity and the surface temperature of the blackbody by TRT(Transfer Reference Thermometer) and IR Micrometer scanner are measured, respectively. From the results, black body design is verified and the uncertainty of NUC is estimated through the measurement results.

A Comparative Study of External & Central Temperature Characteristics during the Moxibustion Period (애주 연소 과정에서 발생하는 애주의 표면 및 중심부의 온도변화 특성 연구)

  • Hong, Deok;Kwon, Oh-Sang;Kim, Young-Jin;Kim, Yu-Lee;Kim, Jae-Hyo;Ahn, Seong-Hun;Sohn, In-Chul
    • Korean Journal of Acupuncture
    • /
    • v.27 no.3
    • /
    • pp.47-56
    • /
    • 2010
  • Objectives : The moxibustion is the method using the heat stimulation done by attached and burned a moxa on a healing point or acupuncture point with chemical stimulation of a resin made from burning them. The purpose of this study is to find the physical and thermal characteristics of moxibustion in order to standardize the moxa therapy method. Methods : In this study, the thermal changes were observed by means of a testo 845 device, which is an infra-red thermometer to measure the thermal changes. Results & Conclusions : 1. The thermal changes on the external surface of moxibustion did not depend on the weight of the moxa; the external surface temperature was about $500^{\circ}C$. 2. The central thermal changes depend on the weight of moxa; the central temperatures ranged from $500^{\circ}C$ to $700^{\circ}C$. 3. The burning duration of moxibustion depend on the weight of moxa but that of external surface temperature did not depend on the weight of moxa in high degree : about $400^{\circ}C$. 4. The integral values of central and external temperature curves were proportional to the weight of moxa; that is central temperature curves were higher than that of external.

A Characteristics on Temperature Change of Warm Needle's Body Depended on Moxa-Corn Weights (애주 무게별 온침의 침체간부 온도 변화 특성 연구)

  • Ahn, Seong-Hun;Hong, Deok;Kwon, Oh-Sang;Kim, Yu-Lee;Kim, Jae-Hyo;Sohn, In-Chul
    • Korean Journal of Acupuncture
    • /
    • v.27 no.2
    • /
    • pp.71-78
    • /
    • 2010
  • Objectives : The warm needling technique is a combination of acupuncture and moxibustion. The purpose of this study was to find the physical and thermal characteristics in order to identify the effects and mechanisms of the warm needling technique. Methods : In this study, the thermal changes were observed with a testo 845 device, which is an infra-red thermometer specifically designed for measuring a combustion of corn shaped moxibustion(moxa-corn). The thermal changes at the apex of the moxa-corn placed on the top of the an acupuncture were observed at the level of 1 cm and 2 cm from the apex to understand heat conduction through acupuncture needle for combustion of moxa-corn. Results and Conclusions : The thermal conduction through acupuncture needle from the moxa-corn was relative to the weight of moxa-corn and was inversely relative to the distance of the moxa-corn and acupuncture needle length. And the value of thermal conduction to the apex of the acupuncture needle from the moxa-corn was about $3{\sim}5^{\circ}C$. The above results suggest that the present study may be useful in finding the mechanism and effects of the warming needling technique.