• Title/Summary/Keyword: Information Signal Process

Search Result 1,424, Processing Time 0.03 seconds

R Wave Detection Algorithm Based Adaptive Variable Threshold and Window for PVC Classification (PVC 분류를 위한 적응형 문턱치와 윈도우 기반의 R파 검출 알고리즘)

  • Cho, Ik-Sung;Kwon, Hyeog-Soong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.11B
    • /
    • pp.1289-1295
    • /
    • 2009
  • Premature ventricular contractions are the most common of all arrhythmias and may cause more serious situation like ventricular fibrillation and ventricular tachycardia in some patients. Therefore, the detection of this arrhythmia becomes crucial in the early diagnosis and prevention of possible life threatening cardiac diseases. Particularly, in the healthcare system that must continuously monitor people's situation, it is necessary to process ECG signal in realtime. In other words, design of algorithm that exactly detects R wave using minimal computation and classifies PVC is needed. So, R wave detection algorithm based adaptive threshold and window for the classification of PVC is presented in this paper. For this purpose, ECG signals are first processed by the usual preprocessing method and R wave was detected and adaptive window through R-R interval is used for efficiency of the detection. The performance of R wave detection and PVC classification is evaluated by using MIT-BIH arrhythmia database. The achieved scores indicate 99.33%, 88.86% accuracy respectively for R wave detection and PVC classification.

A Novel CFR Algorithm using Histogram-based Code Domain Compensation Process for WCDMA Basestation (히스토그램 기반 코드 영역 보상 기법을 적용한 W-CDMA 기지국용 CFR 알고리즘)

  • Chang, Hyung-Min;Lee, Won-Cheol
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.12C
    • /
    • pp.1175-1187
    • /
    • 2007
  • This paper proposes a novel crest factor reduction (CFR) algorithm to be deployed on WCDMA basestation. Generally speaking, it is well described that the reduction of peak-to-average ratio (PAR) yields the possibility of using low cost power amplifier such that the basesation becomes economic However, the simple reduction of PAR could degrade the signal quality measured by either peak code domain error (PCDE) or error vector measurement (EVM), and the level of channel interference constrained by adjacent channel leakage ratio (ACLR). Regarding these imperfections, this paper introduces an effective CFR algorithm in which the function of filter-dependent CFR (FDCFR) incorporated with the histogram-based waterfilling code domain compensation (HBWCDC) carries out. To verify the performance of the proposed CFR technique, substantial simulations including comparative works are conducted with obeying W-CDMA basestation verification specification. To exploit the superiority, the performance of the proposed method is tentatively compared with that associated to the simple memoryless clipping method and the memory-required filter-dependent clipping method.

Fuzzy-Neuro Controller for Speed of Slip Energy Recovery and Active Power Filter Compensator

  • Tunyasrirut, S.;Ngamwiwit, J.;Furuya, T.;Yamamoto, Y.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.480-480
    • /
    • 2000
  • In this paper, we proposed a fuzzy-neuro controller to control the speed of wound rotor induction motor with slip energy recovery. The speed is limited at some range of sub-synchronous speed of the rotating magnetic field. Control speed by adjusting resistance value in the rotor circuit that occurs the efficiency of power are reduced, because of the slip energy is lost when it passes through the rotor resistance. The control system is designed to maintain efficiency of motor. Recently, the emergence of artificial neural networks has made it conductive to integrate fuzzy controllers and neural models for the development of fuzzy control systems, Fuzzy-neuro controller has been designed by integrating two neural network models with a basic fuzzy logic controller. Using the back propagation algorithm, the first neural network is trained as a plant emulator and the second neural network is used as a compensator for the basic fuzzy controller to improve its performance on-line. The function of the neural network plant emulator is to provide the correct error signal at the output of the neural fuzzy compensator without the need for any mathematical modeling of the plant. The difficulty of fine-tuning the scale factors and formulating the correct control rules in a basic fuzzy controller may be reduced using the proposed scheme. The scheme is applied to the control speed of a wound rotor induction motor process. The control system is designed to maintain efficiency of motor and compensate power factor of system. That is: the proposed controller gives the controlled system by keeping the speed constant and the good transient response without overshoot can be obtained.

  • PDF

Patient Adaptive Pattern Matching Method for Premature Ventricular Contraction(PVC) Classification (조기심실수축(PVC) 분류를 위한 환자 적응형 패턴 매칭 기법)

  • Cho, Ik-Sung;Kwon, Hyeog-Soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.9
    • /
    • pp.2021-2030
    • /
    • 2012
  • Premature ventricular contraction(PVC) is the most common disease among arrhythmia and it may cause serious situations such as ventricular fibrillation and ventricular tachycardia. Particularly, in the healthcare system that must continuously monitor patient's situation, it is necessary to process ECG (Electrocardiography) signal in realtime. In other words, the design of algorithm that exactly detects R wave using minimal computation and classifies PVC by analyzing the persons's physical condition and/or environment is needed. Thus, the patient adaptive pattern matching algorithm for the classification of PVC is presented in this paper. For this purpose, we detected R wave through the preprocessing method, adaptive threshold and window. Also, we applied pattern matching method to classify each patient's normal cardiac behavior through the Hash function. The performance of R wave detection and abnormal beat classification is evaluated by using MIT-BIH arrhythmia database. The achieved scores indicate the average of 99.33% in R wave detection and the rate of 0.32% in abnormal beat classification error.

Design of a 32-Bit eFuse OTP Memory for PMICs (PMIC용 32bit eFuse OTP 설계)

  • Kim, Min-Sung;Yoon, Keon-Soo;Jang, Ji-Hye;Jin, Liyan;Ha, Pan-Bong;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.10
    • /
    • pp.2209-2216
    • /
    • 2011
  • In this paper, we design a 32-bit eFuse OTP memory for PMICs using MagnaChip's $0.18{\mu}m$ process. We solve a problem of an electrical shortage between an eFuse link and the VSS of a p-substrate in programming by placing an n-well under the eFuse link. Also, we propose a WL driver circuit which activates the RWL (read word-line) or WWL (write word-line) of a dual-port eFuse OTP memory cell selectively when a decoded WERP (WL enable for read or program) signal is inputted to the eFuse OTP memory directly. Furthermore, we reduce the layout area of the control circuit by removing a delay chain in the BL precharging circuit. We'can obtain an yield of 100% at a program voltage of 5.5V on 94 manufactured sample dies when measured with memory tester equipment.

Analysis on the Characteristics and Product Trend of Wearable Smart Actuator (웨어러블 스마트 액추에이터의 특성과 제품동향 분석)

  • Lee, Hyewon;Suh, Sungeun;Roh, Jung-Sim
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.41 no.6
    • /
    • pp.1022-1038
    • /
    • 2017
  • Wearable smart products contributed to expand the concept of modern clothing in terms of closer communication between wearers and the surrounding environment. This study investigated the concept of wearable smart actuators and characteristics of actuating feedback. The representative product development trends over the past 10 years are examined based on the method of actuating feedback. A first keyword search from Naver and Google reused to select the final 58 products based on the second key keyword actuating feedback. The wearable smart actuator system works in a similar way to a human body system such as those of the information processing process. Actuating feedback is delivered directly to the user as the last signal of the system, which has visual, auditory and tactile feedback. It works in complex at the device to be delivered to the user. Actuator feedback is divided into three types of active and passive, depending on the user situation, the overall purpose of the product, the collected information, and the device dependency. Active actuating feedback determines and actuates the situation on behalf of the user when the user is in an emergency or a disability situation. Passive actuating feedback plays a role in environmental monitoring to help in a healthy daily life.

Analysis of Inflow and Susceptibility Effects in fMRI Obtained by CGE and TRFGE Techniques (CGE와 TRFGE 기법으로 얻은 뇌기능 영상에서 혈류효과와 자화율 효과의 해석)

  • No, Yong-Man;Jeong, Sun-Cheol;Jo, Jang-Hui
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.4
    • /
    • pp.431-438
    • /
    • 1995
  • Functional imaging based on the susceptibility only is achieved by separation of the susceptibility effect from the mixture of flow effect by use of a tailored RF pulse in conjunction with gradient echo sequence. Using the tailored RF pulse the susceptibility enhanced functional imaging appears to be explicitly related to the deoxygenation processes, while in the conventional gradient echo technique functional contrast on $T2^{*}$ effect images appear to be mixed with a significant fraction of blood flow (in- flow) signals of both arterial as well as venous bloods due to the nature of the fast sequence employed with the gradient echo technique. In this paper, using the tailored RF pulses, one can unambiguously separate the susceptibility and flow effects in functional imaging. Since the signal obtained can be made sufficiently high and represents oxygenation process more accurately, it seems possible to study quantitative oxygen metabolisms in brain function hitherto difficult to do with other gradient echo techniques.

  • PDF

3D Object Modeling for Laser Radar Simulation (레이저레이더 시뮬레이션을 위한 3차원 객체 모델링)

  • Kim, Geun-Han;Jun, Chul-Min
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.16 no.2
    • /
    • pp.57-65
    • /
    • 2008
  • The improvement of the performance in laser radar simulation requires fast retrievals of the spatial locations and attributes of objects in response to the laser signals of the simulators. Since the data used in simulation are complex 3D objects such as terrain, buildings and vehicles, and are of large sizes, commonly used 3D modeling tools are not suitable for this use. We proposed a method to store such 3D objects in a database, perform required queries and integrate with visualization tools. We showed the processes for the data modeling based on 3D topological concepts and then building a spatial DBMS. Also, we illustrated the process for accessing and visualizing the stored data using VRML and performed test computations using some laser signal data. With further enhancement on data modeling and LOD problems in visualization, the proposed method will be practically applied in different situations including laser simulation.

  • PDF

Simulation of Ladar Range Images based on Linear FM Signal Analysis (Linear FM 신호분석을 통한 Ladar Range 영상의 시뮬레이션)

  • Min, Seong-Hong;Kim, Seong-Joon;Lee, Im-Pyeong
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.16 no.2
    • /
    • pp.87-95
    • /
    • 2008
  • Ladar (Laser Detection And Ranging, Lidar) is a sensor to acquire precise distances to the surfaces of target region using laser signals, which can be suitably applied to ATD (Automatic Target Detection) for guided missiles or aerial vehicles recently. It provides a range image in which each measured distance is expressed as the brightness of the corresponding pixel. Since the precise 3D models can be generated from the Ladar range image, more robust identification and recognition of the targets can be possible. If we simulate the data of Ladar sensor, we can efficiently use this simulator to design and develop Ladar sensors and systems and to develop the data processing algorithm. The purposes of this study are thus to simulate the signals of a Ladar sensor based on linear frequency modulation and to create range images from the simulated Ladar signals. We first simulated the laser signals of a Ladar using FM chirp modulator and then computed the distances from the sensor to a target using the FFT process of the simulated signals. Finally, we created the range image using the distances set.

  • PDF

Joint Estimation Schemes of Carrier and Sampling Frequency Offsets for MB-OFDM UWB Systems (MB-OFDM UWB 시스템을 위한 반송파 및 샘플링 주파수 오프셋 결합 추정 기법)

  • Cho, Chang-Hoon;Yang, Suck-Chel;Shin, Yo-An
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.10C
    • /
    • pp.965-975
    • /
    • 2005
  • In this paper, we propose and evaluate joint carrier and sampling frequency offset estimation schemes based on the channel estimation sequences in PLCP (Physical Layer Convergence Procedure) preamble for the proper and effcient synchronization of the MB-OFDM WB (Multi-Band Orthogonal Frequency Division Multiplexing Ultra Wide Band) systems which have recently drawn explosive attention for future W-PAN (Wireless Personal Area Network) applications. In the joint estimation schemes, we first estimate the sampling frequency offset, and then estimate the carrier frequency offset using the estimated sampling frequency offset. Moreover, to improve the reliability of the estimated offset values, each process uses a combination scheme based on weighting factors. Simulation results using IEEE 802.15 Task Group 3a UWB channel models reveal that the estimation scheme using the simple weighting factors based on easily-measurable received signal power of each sub-channel shows favorably comparable performance to the ideal scheme using the weighting factors based on the perfectly-estimated frequency response of the channel.