• Title/Summary/Keyword: Information Intensity

Search Result 2,405, Processing Time 0.038 seconds

Factors Affecting South Korean Disaster Officials' Readiness to Facilitate Public Participation in Disaster Management Using Smart Technologies (재난안전 실무자의 스마트 재난관리 준비도에 영향을 미치는 요인에 관한 실증 연구 - 스마트 기술을 활용한 재난관리 민간참여 중심으로 -)

  • Lyu, Hyeon-Suk;Kim, Hak-Kyong
    • Korean Security Journal
    • /
    • no.62
    • /
    • pp.35-63
    • /
    • 2020
  • As the frequency and intensity of catastrophic disasters increase, there is widespread public sentiment that government capacity for disaster response and recovery is fundamentally limited, and that the involvement of civil society and the private sector is ever more vital. That is, in order to strengthen national disaster response capacity, governments need to build disaster systems that are more participatory and function through the channels of civil society, rather than continuing themselves to bear sole responsibility for these "wicked problems." With the advancement of smart mobile technology and social media, government and society as a whole have been called upon to apply these new information and communication technologies to address the current shortcomings of government-led disaster management. As illustrated in such catastrophic disasters as the 2011 Tohoku earthquake and tsunami in Japan, the 2010 Haitian earthquake, and Hurricane Katrina in the United States in 2005, the realization of participatory potential of smart technologies for better disaster response has enabled citizen participation via new smart technologies during disasters and resulted in positive impact on the management of such disasters. In this context, this study focuses on the South Korean context, and aims to analyze Korean government officials' readiness for public participation using smart technologies. On this basis, it aims to offer policy suggestions aimed at promoting smart technology-enabled citizen participation. For this purpose, it proposes a particular model, termed SMART (System, Motivation, Ability, Response, and Technology).

The Aspect of Natural Regeneration for Major Tree Species in the Natural Deciduous Forest (천연문엽수임내(天然聞葉樹林內) 주요(主要) 구성(構成) 수종(樹種)의 천연경신(天然更新) 양상(樣相))

  • Kim, Ji Hong;Yang, Hee Moon;Jin, Guang Ze;Lee, Won Sup;Kang, Sung Kee
    • Journal of Forest and Environmental Science
    • /
    • v.17 no.1
    • /
    • pp.1-17
    • /
    • 2001
  • Forming a part of "Cooperative Practical Study for the Modernization of the Management of National Forest", this study was conducted to provide overall ecological information for the natural regeneration of major tree species on the basis of community structural attributes in the deciduous forest ecosystem. Followings are summarized characteristics of the natural regeneration for the selected tree species. Betula costata : Although large number of seeds are dispersed by wind, they require mineral soils to germinate. Thick litter layer could be an obstacle to germinate. After germination, the seedling requires large amount of light for successful establishment. Acer mono : Characterized by high shade tolerance and weak drought resistance, the seedling should be overcasted with more than 50% of canopy coverage. High stand density should be maintained to produce good quality of timber. The potential of coppice may be high. Ulmus laciniata : Since this species needs high rate of troll moisture and light, around 60% of canopy coverage should be maintained to retain moisture and incoming light. The competition with other vegetation should be removed for the favor of successful seedling establishment. Fraxinus mandshurica : This species requires moist mineral soils to germinate. After germination, the seedling needs large amount of light and moisture for successful establishment. Site preparation should be applied to reduce competition with weedy vegetation. Fraxinus rhynchophylla : Interval of large seed crops may be highly varied. Thick litter layer could be an obstacle to germinate. Site preparation should be applied to reduce competition with weedy vegetation so as to achieve successful seedling establishment. Quercus mongolica : Including the difficulty of seed supply by the consumption, thick litter layer and mountain bamboo cover could be the obstacle to germinate. More than 50% of relative light intensity is necessary to achieve successful seedling establishment. Kalopanax pictus : Thick litter layer could be an obstacle to germinate. The seedling needs large amount of light and moisture for successful establishment. Abies holophylla : In spite of high shade tolerance, the growth rate in sapling stage may be extremely slow. Cornus controversa : Seeds (drups) are consumed and dispersed by animals, tending to be not sufficient in seed supply. This species requires large amount of light for successful germination and seedling establishment. Tilia amurensis : The difficulty of seed supply might be expected with low seed purity and double dormancy. Since thick litter layer could be an obstacle to germinate, the species requires moist mineral soils for successful germination. The potential of coppice may be extremely high.

  • PDF

A survey on the EMF Levels of Study and Electric Appliances in Korea (국내 전철 및 가전제품을 대상으로 한 전자장 수준 실태조사)

  • Jang, Seong Ki;Cho, Yong Sung;Lee, Seok Jo;Yoo, Seong Wha;Jung, Kyung Mi;Lim, Jun Ho
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.1
    • /
    • pp.71-81
    • /
    • 2005
  • The purposes of this study was to collect, analyze, and describe the MF exposure levels from subways in Korea and to measure and evaluate the MF levels generated from electric appliances used at general homes. The target subway lines were Seoul Metropolitan Line 1 to Line 8, Bundang Line, Incheon Line, Daegu Line, Gwangju Line, and Busan Line 1 and Line 2. We measured at each station in those subway lines and, all the train types (pantograph-equipped, motor-equipped, and common), and platform types(facing and isolating) were investigated by the distance(80, 200, 400 cm) from the train on 19 targeted subway lines using 3 magnetic field measuring devices (EMDEXII, Enertech Co.) during the survey from January till October, 2004. On the other hand, the levels of the 60Hz magnetic fields generated from 14 items of home electric appliances such as electric blankets, hair dryers, electric razors, etc. were measured at 10 general homes using 5 EMDEXII meters with a sampling interval of 1.5 second by the distance(surface, 30, 50, 100, 300cm ) from the target electric appliances. The survey results in the whole subway lines examined in this study were as follows; Seoul Metropolitan Line 4 using AC(alternating current) power source showed the highest mean value of $2.85{\mu}T$, followed by Seoul Metropolitan Line 1 running between Seoul and Incheon using AC($2.78{\mu}T$), Seoul Metropolitan Line 1 between Seoul and Uijongbu using AC($2.73{\mu}T$), Bundang Line using AC($1.79{\mu}T$), Seoul Metropolitan Line 1 connected from Yongsan using AC($1.67{\mu}T$), Seoul Metropolitan Line 1 between Seoul and Suwon using AC($0.79{\mu}T$), and so on. In general, the intensity of the magnetic field in the subway systems in Korea was significantly higher when using AC($2.14{\pm}0.91{\mu}T$) than when using DC($0.29{\pm}0.44{\mu}T$) power source. Among the home electric appliances examined, microwave ovens showed the highest mean value of $7.69{\mu}T$, followed by hair dryers($6.47{\mu}T$), vacuum cleaners($5.27{\mu}T$), televisions ($2.26{\mu}T$), electric blankets($1.38{\mu}T$), personal computers ($0.81{\mu}T$), and so on. Two items of electric appliances showed the excess value of $0.2{\mu}T$ at the distance of 30cm in the MF exposure level; electric razors $1.58{\pm}2.13{\mu}T$ and vacuum cleaners $0.48{\pm}0.44{\mu}T$. As a whole, this study showed a tendency that the shift of the MF levels according to the increase of distance from the electric appliances was lower than those of the results surveyed in UK and USA. As a result, this study is expected to suggest meaningful data for the future study in exposure assessment of magnetic fields and for the establishment of guidelines for subways and electric appliances in Korea. More detailed and large scaled exposure assessment studies should be performed continuously to get the various and useful information on health risk assessment of MFs in Korea.

Safety and Reactogenicity of the Inactivated Poliomyelitis Vaccine (PoliorixTM) in Korea (2006-2012) (우리나라 영아에서 주사용 소아마비 백신(PoliorixTM)의 안전성 및 이상반응에 대한 연구)

  • Sin, Jong Beom;Park, Moon Sung;Ma, Sang Hyuk;Choi, Young Youn;Shin, Son Moon;Kim, Won Duck;Kuriyakose, Sherine;Ulianov, Liliana;Hardt, Karin
    • Pediatric Infection and Vaccine
    • /
    • v.20 no.3
    • /
    • pp.139-146
    • /
    • 2013
  • Objective: As per the requirement of Korean Food and Drug Administration, this post-marketing surveillance was conducted in Korea to evaluate the safety and reactogenicity of Poliorix$^{TM}$ following its introduction in 2006. Methods: In this open, multicenter study, the vaccine was administered as per the current practice of Korean doctors and in reference to the guidebook by the Korean Pediatric Society and as indicated in the Korean label which was as follows - for primary vaccination three doses were given to infants at ages 2, 4 and 6 months whereas, for the booster dose a single dose was given to children aged 4-6 years. Safety data during this six year surveillance was collected using diary cards which were distributed to the parents to record adverse events. Results: A total of 639 subjects were enrolled into the study. Of these, 617 subjects and 22 subjects received the vaccine as a primary and booster dose, respectively. At least one unsolicited symptom was reported in 11.4% (73/639) of the subjects during the 7-day follow-up period; upper respiratory tract infection (2.5%;16/639) was the most frequently reported unsolicited symptom. One subject reported at least one unsolicited symptom (gastroenteritis) of grade 3 intensity within the 31-day post-vaccination period. Approximately 1.7% (11/639) of subjects reported 13 serious adverse events (SAEs). All SAEs were resolved by the end of the study. Conclusion: In Korea, primary and booster vaccination with Poliorix$^{TM}$ was well-tolerated in healthy subjects when administered according to the prescribing information as part of routine clinical practice.

  • PDF

The Effects of Salt Levels and Drying Period on Physicochemical and Sensory Parameters of Dry-cured Ham Ripened in Controlled Condition (소금과 건조기간이 발효실에서 제조된 건염햄의 이화학적 및 관능적 특성에 미치는 영향)

  • Seong, Pil-Nam;Cho, Soo-Hyun;Kang, Geun-Ho;Kim, Jin-Hyoung;Park, Beom-Young;Jeong, Da-Woon;Kim, Byeong-Kyeong;Jung, Jae-Hong;Jeong, Seok-Geun;Kim, Dong-Hoon
    • Food Science of Animal Resources
    • /
    • v.31 no.6
    • /
    • pp.914-920
    • /
    • 2011
  • The aim of this study was to analyze the effects of salt and drying period on the physicochemical and sensory parameters of dry-cured ham ripened in a controlled condition. In this study, three treatments were performed: High salt group (HS), salted with 7 g $kg^{-1}salt$ (w/w); Middle salt group (MS), 5 g $kg^{-1}salt$ and; Low salt group (LS), 3 g $kg^{-1}salt$. Three conditions of drying period were applied including 180, 270 and 360 d at $19^{\circ}C$ and 65% relative humidity, and the physicochemical character and sensory properties of M. biceps femoris were investigated. pH and water activity were decreased with increasing drying period, and the pH of LS was higher than that of other treatments (p<0.05). When increasing the drying period, the hardness of HS was steadily raised for 360 d, whereas LS and MS hardened between 180 and 270 d (p<0.05), and there was no significant difference after 270 d. Cohesiveness, glumness and chewiness had a positive relationship with the drying period. Also, springiness, glumness and chewiness showed a positive relationship with salt level. Chroma and hue value were improved by increasing the salt level. As the drying period increased, the rate of hardness and flavor intensity was increased. In general, this research can be used as essential information for the mass production of dry cured ham.

A Method to Calculate a Pass Rate of the ${\gamma}$-index Analysis in Tomotherapy Delivery Quality Assurance (DQA) (단층치료기를 이용한 방사선 치료의 환자별 정도관리 평가를 위한 감마인덱스의 정량화 방법)

  • Park, Dahl;Kim, Yong-Ho;Kim, Won-Taek;Kim, Dong-Won;Kim, Dong-Hyun;Jeon, Ho-Sang;Nam, Ji-Ho;Lim, Sang-Wook
    • Progress in Medical Physics
    • /
    • v.21 no.4
    • /
    • pp.340-347
    • /
    • 2010
  • DQA, a patient specific quality assurance in tomotherapy, is usually performed using an ion chamber and a film. The result of DQA is analysed with the treatment planning system called Tomo Planning Station (TomoPS). The two-dimensional dose distribution of film measurement is compared with the dose distribution calculated by TomoPS using the ${\gamma}$-index analysis. In ${\gamma}$-index analysis, the criteria such as 3%/3 mm is used and we verify that whether the rate of number of points which pass the criteria (pass rate) is within tolerance. TomoPS does not provide any quantitative information regarding the pass rate. In this work, a method to get the pass rate of the ${\gamma}$-index analysis was suggested and a software PassRT which calculates the pass rate was developed. The results of patient specific QA of the intensity modulated radiation therapy measured with I'mRT MatriXX (IBA Dosimetry, Germany) and DQA of tomotherapy measured with film were used to verify the proposed method. The pass rate was calculated using PassRT and compared with the pass rate calculated by OmniPro I'mRT (IBA Dosimetry, Germany). The average difference between the two pass rates was 0.00% for the MatriXX measurement. The standard deviation and the maximum difference were 0.02% and 0.02%, respectively. For the film measurement, average difference, standard deviation and maximum difference were 0.00%, 0.02% and 0.02%, respectively. For regions of interest smaller than $24.3{\times}16.6cm^2$ the proposed method can be used to calculate the pass rate of the gamma index analysis to one decimal place and will be helpful for the more accurate DQA in tomotherapy.

A Comparative Analysis of Standard Uptake Value Using the Recovery Coefficient Before and After Correcting Partial Volume Effect (부분 체적 효과에서 회복 계수를 이용한 보정 전과 후 SUV의 비교 분석)

  • Ko, Hyun-Soo;Park, Soon-Ki;Choi, Jae-Min;Kim, Jung-Sun;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.10-16
    • /
    • 2011
  • Purpose: The partial volume effect occurs because of limit of the spatial resolution. It makes partial loss of intensity and causes SUV to be lower than it should actually be. So the purpose of this study is to calculate recovery coefficient for correcting PVE from phantom study and to compare before and after SUV correction applying to PET/CT examination. Materials and Methods: The flangeless Esser PET phantom consisting of four hot cylinders was used for this study. All of the hot cylinders were filled with FDG solution of 20.72 MBq per 1000 ml, and the phantom background was filled with FDG solution of different concentrations (33.30, 22.20, 16.65 MBq per 6440 ml) to yield H/B ratios of around 4:1, 6:1 and 8:1. Using the Biograph Truepoint 40(SIEMENS, Germany), we applied recovery coefficient method to 30 patients who were diagnosed with lung cancer after PET/CT exam. And then we analyzed and compared SUV before and after correcting partial volume effect. Results: The smaller the diameter of hot cylinder becomes, the more recovery coefficient decreased. When we applied recovery coefficient to clinical patients and compared SUV before and after correcting PVE, before the correction all lesions gave an average max SUV of 7.83. And after the correction, the average max SUV increases to 10.31. The differences in the max SUV between before and after correction were analyzed by paired t test. As a result, there were statistically significant differences (t=7.21, p=0.000). Conclusion: The SUV for quantification should be measured precisely to give consistent information of tumor uptake. But PVE is one of factors that causes SUV to be lower and to be underestimated. We can correct this PVE and calculate corrected SUV using the recovery coefficient from phantom study. And if we apply this correction method to clinical patients, we can finally assess and provide quantitative analysis more accurately.

  • PDF

Cohort Study for the Effect of Chronic Noise Exposure on Blood Pressure among Male Workers (만성적 소음노출이 혈압에 미치는 영향에 대한 코호트연구)

  • Cha, Tae-Joon;Kim, Jang-Rak;Kang, Wee-Chang;Yaang, Seung-Rim;Lee, Choong-Ryeol;Yoo, Cheol-In;Lee, Ji-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.35 no.3
    • /
    • pp.205-213
    • /
    • 2002
  • Objective : Whether exposure to chronic noise induces an increase in blood pressure, or the development of hypertension, has not been established. A cohort study was performed to identify the effects of chronic noise exposure on blood pressure. Methods : 530 males working at a metal manufacturing factory in Busan, Korea were enrolled for the study. They were monitored for 9 consecutive years, from 1991 to 1999, with an annual health check-up. The subjects were divided into 4 groups, which were determines by noise level categories(NLC) according to noise intensity ; NLC-I: office workers, exposed to noise a level below 60dB(A) ; NLC-II: field technical supporters or supervisors, frequently exposed to workplace noise, wearing no hearing protection device; NLC-III: workers, exposed to workplace noise below 85dB(A), wearing ear plugs or muffs; NLC-IV: workers, exposed to workplace noise over 85 dB(A), wearing both ear plugs and muffs. Results : After controlling possible confoundens, such as baseline age, smoking, alcohol intake, exercise, family history of hypertension, systolic(SBP) of diastolic blood pressure(DBP) and changes in BMI (body mass index), the pooled mean for the systolic blood pressures, over the duration of the study period, were 3.8mmHg, 2.0mmHg and 1.7mmHg higher in NLC-IV, NLC-III NLC-II groups, respectively, than in the NLC-I group. There were no significant differences in the diastolic blood pressures between the groups. Conclusion : This study suggests that chronic noise exposure increases systolic blood pressure independently, among male workers.

Effect of MRI Media Contrast on PET/MRI (PET/MRI에 있어 MRI 조영제가 PET에 미치는 영향)

  • Kim, Jae Il;Kim, In Soo;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.19-25
    • /
    • 2014
  • Purpose: Integrated PET/MRI has been developed recently has become a lot of help to the point oncologic, neological, cardiological nuclear medicine. By using this PET/MRI, a ${\mu}-map$ is created some special MRI sequence which may be divided parts of the body for attenuation correction. However, because an MRI contrast agent is necessary in order to obtain an more MRI information, we will evaluate to see an effect of SUV on PET image that corrected attenuation by MRI with contrast agent. Materials and Methods: As PET/MRI machine, Biograph mMR (Siemens, Germany) was used. For phantom test, 1mCi $^{18}F-FDG$ was injected in cylinderical uniformity phantom, and then acquire PET data about 10 minutes with VIBE-DIXON, UTE MRI sequence image for attenuation correction. T1 weighted contrast media, 4 cc DOTAREM (GUERBET, FRANCE) was injected in a same phatnom, and then PET data, MRI data were acquired by same methodes. Using this PET, non-contrast MRI and contrast MRI, it was reconstructed attenuation correction PET image, in which we evanuated the difference of SUVs. Additionally, for let a high desity of contrast media, 500 cc 2 plastic bottles were used. We injected $^{18}F-FDG$ with 5 cc DOTAREM in first bottle. At second bottle, only $^{18}F-FDG$ was injected. and then we evaluated a SUVs reconstructed by same methods. For clinical patient study, rectal caner-pancreas cancer patients were selected. we evaluated SUVs of PET image corrected attenuastion by contrast weighted MRI and non-contrast MRI. Results: For a phantom study, although VIBE DIXON MRI signal with contrast media is 433% higher than non-contrast media MRI, the signals intensity of ${\mu}-map$, attenuation corrected PET are same together. In case of high contrast media density, image distortion is appeared on ${\mu}-map$ and PET images. For clinical a patient study, VIBE DIXON MRI signal on lesion portion is increased in 495% by using DOTAREM. But there are no significant differences at ${\mu}-map$, non AC PET, AC-PET image whether using contrast media or not. In case of whole body PET/MRI study, %diff between contras and non contrast MRAC at lung, liver, renal cortex, femoral head, myocardium, bladder, muscle are -4.32%, -2.48%, -8.05%, -3.14%, 2.30%, 1.53%, 6.49% at each other. Conclusion: In integrated PET/MRI, a segmentation ${\mu}-map$ method is used for correcting attenuation of PET signal. although MRI signal for attenuation correciton change by using contrast media, ${\mu}-map$ will not change, and then MRAC PET signal will not change too. Therefore, MRI contrast media dose not affect for attenuation correction PET. As well, not only When we make a flow of PET/MRI protocol, order of PET and MRI sequence dose not matter, but It's possible to compare PET images before and after contrast agent injection.

  • PDF

Changes in Contents of Chlorophyll and Free Proline as Affected by NaCl in Rice Seedling (NaCl처리에 따른 벼 유묘기의 엽록소 및 유리 Proline의 함량 변화)

  • 이강수;이종신;최선영
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.37 no.2
    • /
    • pp.178-184
    • /
    • 1992
  • The changes in contents of chlorophyll and free proline in the seedling leaves of ten rice cultivars as affected by salt stress were checked in order to obtain the basic information on the judgement of the degrees of salt injury. The difference in salt injury among the cultivars was clearly observed about 25 days after 6% salt treatment. Chlorophyll content was decreased in both Gayabyeo and Taebaegbyeo for 14 days after different salt treatment as salt concentration was increased and the decreased tendency was much higher in Taebaegbyeo than in Gayabyeo over 0.4% salt concentration. Chlorophyll content in Gayabyeo after 0.6% salt treatment was decreased slowly, while in Taebaegbyeo, deminished very rapidly as time progressed, therefore it decreased by about 16% in Gayabyeo and 67% in Taebaebyeo compared to the control at 20 days, respectively. The relationship between chlorophyll content and the degrees of salt injury in ten rice cultivars showed significant negative correlation at 10 day after 0.6% salt treatment. Free proline content in Gayabyeo was increased gradually for 14 days after different salt treatment as salt became higher, while in Taebaebyeo, it was increased rapidly under 0.6% but rather decreased under 0.8% salt concentration. Particularly, it was much higher Taebaegbyeo than in Gayabyeo under salt concentration from 0.4 to 0.6%. Free proline content in Gayabyeo after 0.6% salt treatment was increased from 15 days, on the other hand in Taebaegbyeo, it was increased from 5 days, but rather decreased from 20 days, and it was 6 times higher in Taebaegbyeo than in Gayabyeo at 10 days. There was significant positive correlation between free proline content and the degrees of salt injury in ten rice cultivars at 10 days after 0.6% salt treatment. From the above results, chlorophyll and free proline content may be used as an indicative character of intensity of salt stress as well as varietal difference in resistance to salt stress in the seedling stage.

  • PDF