• 제목/요약/키워드: Influents

검색결과 34건 처리시간 0.036초

산업폐수의 생물독성 발현에 관한 연구 (Evaluation on Environmental Bio-toxicity of Industrial Wastewater)

  • 김상훈;천세억;신기식;정동일
    • 한국물환경학회지
    • /
    • 제21권3호
    • /
    • pp.274-276
    • /
    • 2005
  • To investigate bioassay for toxic level evaluation of wastewater, toxic levels were checked influents and effluents of 6 wastewater discharge facilities with Daphnia magna and Vibrio fischeri. In view of test duration, D. magna is preferred at 48 hours. And it was judged to efficient that one of the two was choosen for toxicity test method (Daphnia test and Vibrio test). Analysis data for wastewater is average toxic level for influent more higher than effluent. And effluent toxic level is sharp decrease than effluents.

산업단지 폐수종말처리장의 특정수질유해물질 유입 및 방류 현황조사 (Sampling Survey of Hazardous Water Pollutants in Industrial Wastewater Treatment Plants)

  • 박수형;정진영;김재훈;이원태
    • 대한환경공학회지
    • /
    • 제37권10호
    • /
    • pp.590-595
    • /
    • 2015
  • 본 연구는 국내 산업단지 폐수종말처리장의 유입수 및 방류수에 존재하는 특정수질유해물질 농도분포 현황을 조사하여 폐수종말처리장으로부터 수계로 배출되는 특정수질유해물질의 효율적인 관리방안을 마련하는 기초자료를 확보하기 위해 수행되었다. 실태조사는 산업단지에 위치하고 실제 처리 및 방류량 기준 $2,000m^3$/일 이상 규모인 27개 폐수종말처리장을 대상으로 진행하였다. 시료채취는 2012년 7~9월에 걸쳐 각 처리장별로 3회(월 1회) 실시하였고, 관리대상 특정수질유해물질 28개 항목 중 22개에 대하여 분석하였다. 산업단지 폐수종말처리장 유입수에서는 수은, 비소, 1,1-디클로로에틸렌, 벤젠 등이 특례지역기준대비 높은 농도로 검출되었고, 방류수에서는 수은, 비소 등이 청정지역기준대비 높은 농도로 검출되었다. 폐수종말처리장의 특정수질유해물질 평균 제거율(상전이 포함)은 셀레늄(30%), 1,4-다이옥산(18%)을 제외하고는 60%이상을 나타냈다.

Toxicity characteristics of sewage treatment effluents and potential contribution of micropollutant residuals

  • Kim, Younghee;Farnazo, Danvir Mark
    • Journal of Ecology and Environment
    • /
    • 제41권11호
    • /
    • pp.318-327
    • /
    • 2017
  • Background: A typical sewage treatment plant is designed for organic and nutrient removal from municipal sewage water and not targeted to eliminate micropollutants such as pesticides, pharmaceuticals, and nano-sized metals which become a big concern for sustainable human and ecological system and are mainly discharged from sewage treatment plant. Therefore, despite contaminant removal by wastewater treatment processes, there are still remaining environmental risks by untreated pollutants in STP (sewage treatment plant) effluents. This study performed aquatic toxicity tests of raw wastewater and treated effluents in two sewage treatment plants to evaluate toxicity reduction by wastewater treatment process and analyze concentration of contaminants to reveal potential toxic factors in STP effluents. Methods: Water samples were collected from each treatment steps of two STPs, and acute and chronic toxicity tests were conducted following USEPA (United States Environmental Protection Agency) and OECD (Organization for Economic Cooperation and Development) guidelines. Endpoints were immobility for mortality and reproduction effect for estrogenicity. Results: Acute $EC_{50}s$ (median effective concentration) of influents for Seungki (SK) and Jungnang (JN) STPs are $54.13{\pm}32.64%$ and $30.38{\pm}24.96%$, respectively, and reduced to $96.49{\pm}7.84%$ and 100%. Acute toxicity reduction was clearly correlated with SS (suspended solids) concentration because of filter feeding characteristics of test organisms. Chronic toxicity tests revealed that lethal effect was reduced and low concentration of influents showed higher number of neonates. However, toxicity reduction was not related to nutrient removal. Fecundity effect positively increased in treated wastewater compared to that in raw wastewater, and no significant differences were observed compared to the control group in JN final effluent implying potential effects of estrogenic compounds in the STP effluents. Conclusions: Conventional wastewater treatment process reduced some organics and nutritional compounds from wastewater, and it results in toxicity reduction in lethal effect and positive reproductive effect but not showing correlation. Unknown estrogenic compounds could be a reason causing the increase of brood size. This study suggests that pharmaceutical residues and nanoparticles in STP effluents are one of the major micropollutants and underline as one of estrogenic effect factors.

국내 하천수 및 하수처리장 유입.방류수의 합성머스크화합물 오염실태 조사 (Occurrence of Synthetic Musk Compounds in Surface and Waste Waters in Korea)

  • 이인정;이철구;허성남;이재관
    • 대한환경공학회지
    • /
    • 제33권11호
    • /
    • pp.821-826
    • /
    • 2011
  • 합성머스크화합물은 개인이 일상생활에서 광범위하게 사용하는 비누, 화장품, 향수, 세제, 방향제 등에 향료로 사용되며 하 폐수 처리시설에서 완벽하게 제거되지 않고 생활하수에 포함된 상당수의 양이 환경 중으로 배출되고 있다. 외국사례의 경우 하천, 해양, 토양, 저질, 생물상 등 다양한 환경매체에서 검출되고 있으며, 잔류성 생물농축성이 있어 지속적으로 노출 시 생태계 및 인간의 건강에 심각한 영향을 끼칠 우려가 있다. 합성머스크화합물 15종(musk ketone, musk xylene, musk ambrette, musk moskene, musk tibetene, HHCB, AHTN, ADBI, AHDI, DPMI, ATII, ethylenebrasssylate, ambretettolide, cyclopentadecanolide, OTNE)을 액액 추출법으로 전처리 한 후 GC/MS로 분석하였으며, 방법검출한계는 $0.005{\sim}0.398{\mu}g/L$로 나타났다. 낙동강 유역의 하천수 20개 지점 및 하수처리장 6개 지점을 조사한 결과 일부 조사대상 물질이 검출되었다. HHCB와 AHTN은 가장 검출빈도가 높은 항목으로 대부분의 하천수 및 하수처리장 유입 방류수에서 검출되었으며, 검출농도는 외국의 조사결과와 유사한 수준이었다.

우리나라 공공하수처리시설의 방류수 수질현황 분석을 통한 겨울철 방류수수질기준의 적정성 평가 (Evaluation of Korean Water Quality Standards in Winter by Characteristics and Statistical Analyses of the Effluent Water Quality at the Sewage Treatment Plants in Korea)

  • 엄철용;주경훈;윤주환;최익훈;박재영;이한샘;고광백
    • 한국물환경학회지
    • /
    • 제27권4호
    • /
    • pp.523-532
    • /
    • 2011
  • In this study, from 2004 to 2008 influents and discharging effluents from 241 municipal public sewage treatment plants were surveyed. Statistics including average, Coefficient of Variation (CV) and Coefficient of Reliability (COR) for each season, time series analysis for removal efficiency and water quality of effluents, and a comparison of the effluent standards in Korea and other countries were presented. The average concentrations of TN and TP in influents. during winter season were 32.6 and 3.78 mg/L and during other season were 30.8 and 3.61 mg/L in 2008, respectively. The average TN concentration on the basis of the maximum monthly concentrations in the effluents during winter season ranged from 14.2~17.4 mg/L and during other season ranged from 12.2~14.8 mg/L. The TP concentration in the effluents depending on the each season was no big difference. TN removal efficiency decreased from Jan. to Feb. and TP removal efficiency decreased in Jan., Jun and July. Maximum COR during winter season were 0.61 but the COR for TN and TP during other season ranged from 0.96~1.48 and 1.09~1.81, respectively, due to big difference in the standard for TN and TP in effluents depending on the season. TN and TP standards for effluent of sewage treatment during winter season in Korea was much higher than those in other countries. Therefore the lower effluent standards during winter season is essential for the water quality improvement.

태안해안국립공원 연안으로 유입되는 하계-추계 육상오염원의 오염도 평가(2017~2018) (Evaluation of the contamination Level of Inland Pollution Sources Flowing into Taeanhaean National Park in Summer and Fall (2017-2018))

  • 황다혜;김진현;장성건;정원옥;정병관
    • 한국환경과학회지
    • /
    • 제31권6호
    • /
    • pp.491-501
    • /
    • 2022
  • This study evaluated the contamination levels of inland pollution sources flowing into Taeanhaean National Park. The nutritional status of influents was assessed by analyzing water quality and trophic status index (TRIX) at 52 stations, and the contamination levels of sediments were evaluated by analyzing eutrophication cleanup index (CIET) and heavy metals at 36 stations. The results of the TRIX analysis showed that 26 of the 52 stations had influents with a TRIX value of 6-10 (poor water quality/very high trophic level), indicating atrocious water quality and high eutrophication levels. The results of the CIET analysis showed that 4 out of the 36 stations were highly contaminated with organic matter. Analysis of heavy metals showed that the copper (Cu) and zinc (Zn) levels exceeded the threshold effects level (TEL) and probable effects levels (PEL) at several stations. In addition, the arsenic (As) level exceeded the threshold effects level at one station, and the levels of the other heavy metals (Cd, Cr6+, Ni, Pb, and Hg) were lower. Most inland pollution sources have been identified as small-scale, but long-term and continuous exposure can negatively affect the marine ecosystem; therefore, it necessary to prepare inland pollution source management standards and measures suitable for the characteristics of the coastal area.

대구지역 금호강 및 주요 지천 퇴적물의 시 . 공간적 독성변화 (Temporal and Spatial Change of Sediment Toxicity in Keumho River and its Major Influents, Taegu, Korea)

  • 정홍배;문성환;정진애;김재현;박정규;배철한;황인영
    • Environmental Analysis Health and Toxicology
    • /
    • 제16권4호
    • /
    • pp.161-170
    • /
    • 2001
  • In aqueous ecosystems, the level of toxicity is highly responsive dependant to multiple variables, including rainfall, sunlight, pH, adhesion, etc. Because Korea has particularly distinct wet and dry seasons, the toxicity of pollutants in rivers or streams is dependant on the sampling season and time. In order to examine the effects of rainfall on toxicity, sediment samples were collected from five sites along the Keumho river. It was found that Microtox toxicity levels were generally higher during the dry season than the wet season. It indicated that river pollutants are carried off more quickly by the water during the wet season. As a result, it was recommended that the point sources of pollutants of the Keumho river would be placed between KH3 (Paldalgyo) and KH4(Keumhogyo), KH4(Keumhogyo) and KH5(Dasa).

  • PDF

실규모 하수처리공정에서 동력학적 동특성에 기반한 인공지능 모델링 및 예측기법 (Artificial Neural Network Modeling and Prediction Based on Hydraulic Characteristics in a Full-scale Wastewater Treatment Plant)

  • 김민한;유창규
    • 제어로봇시스템학회논문지
    • /
    • 제15권5호
    • /
    • pp.555-561
    • /
    • 2009
  • The established mathematical modeling methods have limitation to know the hydraulic characteristics at the wastewater treatment plant which are complex and nonlinear systems. So, an artificial neural network (ANN) model based on hydraulic characteristics is applied for modeling wastewater quality of a full-scale wastewater treatment plant using DNR (Daewoo nutrient removal) process. ANN was trained using data which are influents (TSS, BOD, COD, TN, TP) and effluents (COD, TN, TP) components in a year, and predicted the effluent results based on the training. To raise the efficiency of prediction, inputs of ANN are added the influent and effluent information that are in yesterday and the day before yesterday. The results of training data tend to have high accuracy between real value and predicted value, but test data tend to have lower accuracy. However, the more hydraulic characteristics are considered, the results become more accuracy.

Analysis of the Activated Sludge of a Municipal WWTP by Several Bio-Parameters

  • Cho Sun-Ja;Jung Yong-Ju;Park Tae-Joo;Lee Sang-Joon
    • 한국환경과학회지
    • /
    • 제14권9호
    • /
    • pp.811-815
    • /
    • 2005
  • The activated sludge from the aeration basin of the Su-yeong municipal wastewater treatment plant which has operated by a standard activated sludge process in Busan, Korea was investigated during April 2004 and January 2005 with several bio-indicators. The number of bacteria and fungi per gram of dry weight of MLSS were estimated to be $3.1\times10^6\sim1.5\times10^8\;and\;l.1\times10^3\sim1.1\times10^5$ colony forming units, respectively, by the plate agar method. By cultivation-independent methods, such as 4',6-diamidino-2-phenylindole stain and fluorescence in situ hybridization, the ratio of eubacteria to the entire biomass was evaluated by more than $80\%$ (v/v). The ratio of ammonia-oxidizing bacteria and nitrite-oxidizing bacteria to the total eubacteria was detennined to be $7.0\sim9.8\%\;and\;3.3\sim6.2\%$ without heavy variation in spite of a period of relatively low temperature in the basin. It would be expected that the nitrification would occur or at least co-exist throughout the year in the sludge of many municipal WWTP with influents that contain the sufficient nitrogen sources although the WWTP does not have any specialized processes for the removal of nitrogen.