• 제목/요약/키워드: Influent water quality

검색결과 187건 처리시간 0.025초

하수처리수의 재이용을 위한 처리습지 및 도시 상류하천 생태환경복원 - 공주시 제민천 생태적수질정화비오톱을 중심으로 - (An Ecological Restoration of Treatment Wetland and Urban Upper Stream for Reusing Sewage Treatment Water - In the case of Sustainable Structured Wetland Biotop System at Upper Part of Jaemin Stream in Gongju-si, Korea -)

  • 변찬우
    • 한국환경복원기술학회지
    • /
    • 제17권5호
    • /
    • pp.65-77
    • /
    • 2014
  • The ecosystem of Jaemin stream, flowing into the center of Gongju-si, had been damaged by low water quality and lack of water quantity of the steam. However, after applying the SSB (Sustainable Structured wetland Biotop) system to the flood plain and the upstream of Jaemin stream, the efficiency of ecological water purification and ecological restoration are as follows. Through the constant maintenance and monitoring from year 2009 to year 2013 after restorative design and construction the average influent concentration of BOD5 was 4.2 mg/L, and the average effluent concentration was 1.8 mg/L, reaching ecological water purification rate of 57%. As for the T-N, the average influent concentration was 9.983 mg/L, and the average effluent concentration was 6.303 mg/L, showing the rate of 37%. For the T-P, the average influent concentration was 0.198 mg/L, and the average effluent concentration was 0.098 mg/L, being the rate of 51%. The vegetation of Jaemin stream monitored for 2 years after the restoration was composed of 51 species in 28 families which show high ratio of planted native species. As for the animals in the site, 5 species in 3 families of reptiles and amphibians, 34 species of 23 families of birds, and 3 species in 2 families of mammals were monitored, indicating that the bio-diversity of the site has improved, as well.

정수처리공정에서의 입자분석 적용방안 (Application of Particle Counter in Water Treatment Process)

  • 신상희;전현숙;이찬형;배기수
    • 한국물환경학회지
    • /
    • 제29권3호
    • /
    • pp.337-342
    • /
    • 2013
  • The particle counter compared with the turbidimeter provides good precision and sensitivity and can get the characteristics of particulates effectively. The purpose of this study is to provide the application of particle counter in sand and activated carbon filters. The particle count by size could be more easily sense when the water quality is changed by the influent of high turbidity or algae. We could decide the optimal backwashing cycles and detect the efficiencies of filters by monitoring the total particle count of effluent in sand and activated carbon filters.

자유수면습지의 잔재물층에 의한 하천수 질소제거 비교 (Comparison of Nitrogen Removal in Free Water Surface Wetlands Purifying Stream Water with and without Litter Layer on its Bottom)

  • 양홍모
    • 한국환경복원기술학회지
    • /
    • 제11권6호
    • /
    • pp.120-129
    • /
    • 2008
  • Removal rate of $NO_3-N$ and TN in a free water surface wetland system with litter layer on its bottom was compared with that without one. The system was established on floodplain in the down reach of the Gwangju Stream in 2001. Its dimensions were 31 meters in length and 12 meters in width. Water of the stream was funneled into it and its effluent was discharged back into the channel. Average litter layer of 9.6 cm was formed on its bottom in 2007. The layer and above-ground parts of reeds and cattails on the system were eliminated in Spring 2008. Volumes and water quality of inflow and outflow of the system were analyzed from May to November in 2007 and 2008, respectively. Inflow into the system both in 2007 and 2008 averaged approximately $40m^3/day$ and hydraulic residence time both in 2007 and 2008 was about 1.5 days. Average influent $NO_3-N$ concentration in 2007 and 2008 was 2.16 and 2.05 mg/L, respectively and influent TN concentration in 2007 and 2008 averaged 3.98 and 3.89 mg/L, respectively. With a 0.05 significance level, effluent temperatures, influent concentrations of $NO_3-N$ and TN, and stem numbers per square meter and height of the emergent plants showed no difference between the system with litter layer and without one. $NO_3-N$ removal in the system with litter layer and without it averaged 55.59 and 46.06%, respectively and TN retention averaged 57.24 and 48.97%, respectively. Both $NO_3-N$ and TN abatement rates in the system with litter layer were significantly high (p < 0.001) when compared with those without one. The wetland system having litter layer on its bottom was more efficient for $NO_3-N$ and TN retention than that without one.

습지여상시설을 이용한 하천 수질정화 (Purification of Stream Water Quality by Subsurface-flow Wetland Facility)

  • 정용준;임기성
    • 한국물환경학회지
    • /
    • 제22권3호
    • /
    • pp.456-461
    • /
    • 2006
  • The facility of constructed wet land combined with filter media was examined in order to improve the water quality of a polluted stream, which has been performed as a part of national projects. Throughout 2 years of operation for a stream, it can provide the design and operating parameters for the purpose of future construction. The influent flow rate was about 50% against the design capacity. The removal efficiencies of BOD, $COD_{Mn}$, SS, T-N and T-P were 62.9%, 47.1%, 74.8%, 22.4% and 33.5%, respectively. In order to keep this facility stable, the removal of surface filter media and supplement should be periodically conducted. In addition, the proper selection of sites is recommended not to be flooded.

하수처리장 방류수를 이용한 인공함양 가능성 평가

  • 김병군;서인석;홍성택;김형수
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 추계학술발표회
    • /
    • pp.257-260
    • /
    • 2002
  • The main purpose of this research is to find suitable treatment methods of wastewater effluent for artificial recharge. For this purpose, we search the effluent quality of wastewater treatment plant and possibility of additional filtration process. Particles ranged 2 ~ 5 ${\mu}{\textrm}{m}$ and 15~20 ${\mu}{\textrm}{m}$ in "T" WWTP(Waste Water Treatment Plant) effluent were relatively dominant. In dual-media filtration system operation, head-loss development of column 1 was about two times faster than column 2, and head-loss development within 5 cm from surface was very important factor in operation, Conclusively, for the stable filtration and running time of 1.5~2 day, influent turbidity must keep 5 NTU or below, and filtration system must operated at 280 m/day or below. After filtration of WWTP effluent, water quality reached satisfactory level. This water has potential of agricultural reusing, flushing water in building, recharging water to river or stream at dry season and artificial recharge of ground water.und water.

  • PDF

산화구 하수처리공정의 최적설계에 관한 기초연구 (A Study on Model Based Optimum Design of Oxidation Ditch in Sewage Treatment)

  • 도현승
    • 한국방재안전학회논문집
    • /
    • 제12권2호
    • /
    • pp.25-34
    • /
    • 2019
  • 본 연구에서는 산화구 방법으로 하수처리를 하는 공공 하수처리장을 선정하여 통계적인 방법으로 처리장의 수질 및 운영의 효율을 분석하였다. 얻어진 수질 데이터는 유입수 및 배출수의 pH, 온도, BOD, SS, T-N, ${NH_4}^+-N$ 및 T-P였다. 데이터 분석은 군집분석, 상관분석, ANOVA 분석, 클러스터 분석으로 수행되었다. 통계분석 결과, 하수 처리장의 유입 유량은 여름에 가장 높았으며 평균 유속은 $3.000m^3/s$이었다. Box plot 결과에 따르면, 하수의 COD, 총인 농도는 계절에 변화에 따라 크게 차이가 없었다. Pearson 상관관계 분석결과는 유입수에서 BOD, COD, T-N 및 T-P 간에 강한 양의 상관관계를 보였다. 계절변화에 따른 BOD와 T-N 농도는 겨울철에 가장 높았고, 계절에 따른 온도의 영향은 COD와 T-P가 가장 높았다. BOD는 수온과 음의 상관관계를 보였으나 HRT, SRT, C/N과 같은 공정인자는 양의 상관관계를 나타내었다. 유입수 온도가 높을수록 BOD 농도가 낮아지는 현상을 보였으며, 체류 시간이 단축될수록 BOD의 처리 효율이 저하되었다. T-N은 효율적인 처리를 위해 긴 체류 시간이 필요했으나 T-P는 공정인자의 변화에 따른 상관관계도에서 다소 적게 나타났다.

호기성 침지형 생물막 여과장치를 이용한 오수처리 (Sewage Treatment using Aerated Submerged Biological Filter(ASBF))

  • 박종웅;송주석
    • 한국물환경학회지
    • /
    • 제16권4호
    • /
    • pp.523-532
    • /
    • 2000
  • The purpose of this study was to investigate the effects of the hydraulic retention time (HRT) and organic loading rate (OLR) on microbial characteristics and treatment efficiency in sewage treatment using aerated submerged biological filter (ASBF) reactor. This reactor combines biodegradation of organic substrates by fixed biomass with a physical separation of biomass by filtration in a single reactor. Both simulated wastewater and domestic wastewater were used as feed solutions. The experimental conditions were a temperature of 17 to $27^{\circ}C$, a hydraulic retention time of 1 to 9hr, an organic loading rate of 0.47 to $3.84kg\;BOD/m^3{\cdot}day$ in ASBF reactor. This equipment could obtain a stable effluent quality in spite of high variation of influent loading rate. Total biomass concentration. biofilm thickness and biofilm mass increased an exponential function according to the increasing OLR. The relationships between water content and biofilm density were in inverse proportion. The percentage of backwash water to influent flow was almost 9%. The separation efficiency of biomass was the percentage of 91 to 92 in ASBF reactor. The sludge production rates in feed solutions of simulated wastewater and domestic wastewater were 0.14~0.26 kg VSS/kg BODrem, 0.43~0.48 kg VSS/kg BODrem, respectively.

  • PDF

단기 수리학적 충격부하시 침전지 내장형 상분리 산화구공정의 처리 안정성 평가 (Stability Evaluation of Phased Isolation Intra-Clarifier Ditch Process on Short-Term Hydraulic Shock Loading)

  • 홍기호;장덕
    • 상하수도학회지
    • /
    • 제19권6호
    • /
    • pp.791-799
    • /
    • 2005
  • The phased isolation intra-clarifier ditch system used in this study is a simplified novel process enhancing simultaneous removal of biological nitrogen and phosphorus in municipal wastewater in terms of elimination of additional pre-anaerobic reactor, external clarifier, recycle of sludge, and nitrified effluent recirculation by employing intrachannel clarifier. Laboratory-scale phased isolation ditch system was used to assess the treatability on municipal wastewater. When the system was operated at the HRTs of 6~12hours, SRTs of 9~31days, and cycle times of 2~8hours, the system showed removals of BOD, TN, and TP as high as 88~97%, 70~84%, and 65~90%, respectively. The rainfall in Korea is generally concentrated in summer because of site-specific characteristics. Especially, the wet season has set in on June to August. In combined sewers, seasonal variations are primarily a function of the amount of stormwater that enters the system. In order to investigate the effect of hydraulic shock loading on system performance, the laboratory-scale system was operated at an HRT of 6hours (two times of influent flowrate) during two cycles (8hours). The system performance slightly decreased by increasing of influent flowrate and decreasing of system HRT. Nitrification efficiency and TN removal were slightly decreased by increasing of influent flowrate (decreasing of system HRT), whereas, the denitrification was not affected by hydraulic shock loading. However, the higher system performance could be achieved again after four cycles. Thus, the phased isolation technology for enhanced biological nutrient removal in medium- and small-scale wastewater treatment plants suffering fluctuation of influent quality and flowrate.

자연정화방법에 의한 오수처리와 농업적 재이용 타당성 검토 (Feasibility Study of Natural Systems for Sewage Treatment and Agricultural Reuse)

  • 윤춘경;정광욱;함종화;전지홍
    • 한국농공학회지
    • /
    • 제45권6호
    • /
    • pp.194-206
    • /
    • 2003
  • A pilot study was performed to examine the feasibility of the pond system for further polishing of treatment wetland effluent to agricultural reuse of reclaimed water. The constructed wetland and pond system was installed in Konkuk University and the effluent from septic tank of school building was used as an influent to the wetland system. The effluent of the wetland was used as an influent to pond systems. The influent concentrations of total coliform(TC), fecal coliform (FC), and E. coli were about $10^5$MPN/100 ml, and they were reduced to less than 10,000 MPN/100 ml on average after wetland treatments, showing over 95 % removal. And they were further reduced to less than 1,000 MPN/100 ml in average, showing over 85∼93 % removal after pond treatment. Turbidity and SS were improved effectively on average and their pond effluent concentration was about 4.5 NTU and 9.8 mg/L in average, respectively Average $BOD^5$ concentrations were also reduced substantially to 9.3 mg/L with about 83 % removal rate after wetland and pond treatment systems. Nutrients removal was relatively low and removal rate for T-N and T-P was less than 43 and 44%, respectively after wetland and pond treatment. Considering stable performance and effective removal of bacterial indicators as well as other water quality parameters, low maintenance, and cost-effectiveness, pond system was thought to be an effective and feasible alternative for agricultural reuse of reclaimed water. This paper describes a preliminary result Iron pilot study and further investigations are recommended on the optimum design parameters before full scale application.

인공습지를 이용한 하구담수호 유입하천수 수질개선 현장실험결과 분석 (Analysis of Field Experimental Data for Water Quality Improvement of Tributary Stream to Estuarine Reservoir Using Constructed Wetland System)

  • 함종화;윤춘경;구원석;김형철;신현범
    • 한국농공학회논문집
    • /
    • 제46권5호
    • /
    • pp.141-153
    • /
    • 2004
  • Wetland system is widely accepted as one of natural water purification systems around the world for nonpoint sources pollution control. Constructed wetlands have become a popular technology for treating contaminated surface and waste water. In this study, the field experiment to reduce nonpoint source pollution loadings from polluted stream waters using wetland system was performed from June 2002 to March 2004. Four wetlands were used and the size of each one was 0.8ha. Water of Dangjin stream flowing into Seokmun estuarine reservoir was pumped into wetlands. Inflow and hydraulic residence time of the system was 500 $m^3$/day∼1,500 $m^3$/day, 2∼5 days, respectively. After 2 year operation, plant-coverage of the wetlauds was about 70% from bare soil surface at initial stage . Average water quality of the influent was $BOD_5$ 4.17 mg/L, TSS 18.45 mg/L, T-N 4.32 mg/L, and T-P 0.30 mg/L. The average removal rate of $BOD_5$, TSS, T-N and T-P during the study period was 5.6%, 46.6%, 45.7%, and 54.8%, respectively. Organic ($BOD_5$) removal rate was low and the reason might be low influent concentration. Wetland removal rate of T-P was about 10% higher than T-N. Performance of the experimental system was compared with existing data base (NADB), and it was within the range of general system performance. Overall, the wetland system was found to be adequate for treating polluted water stream with stable removal efficiency even during the winter period. Most of the nonpoint source pollutions from watershed are transported by streams or ditches, and they could be controled by constructed wetland system before entering the lake or reservoir.