• 제목/요약/키워드: Influent water quality

검색결과 187건 처리시간 0.023초

백운산 지역내 중소형 양어장에 의한 계류수의 이화학적 요인의 변화 (Changes on the Physicochemical Factor of Stream Water by Medium and Small type Fish Farm in Mt. Baegun Area)

  • 박재현
    • 한국환경복원기술학회지
    • /
    • 제8권3호
    • /
    • pp.43-52
    • /
    • 2005
  • Evaluations of the fish farm influences on stream water quality may provide basic informations on watershed management to reduce environmental impact due to fish farm development and to conserve stream water quality in forested watershed area. In this research influent, effluent water in the fish farm and stream water qualities around Mt. Baegun area were monitored seasonally for six years and the following results were obtained. Due to the increase of pH in effluent water from the fish farm it was believed that alkalization of stream water can be accelerated by large scale development of fish farms in the forested watershed area. Also, effluent water from the fish farm increase of EC higher than influent and stream water. As a result of regression analyses, pH, EC, DO, water temperature, total amount of cation and anion in influent and effluent water of fish farm show high significance.

대전시 공공하수처리시설 유입수 수질자료의 통계적 특성 및 추계학적 모의 (Statistical Characteristics and Stochastic Modeling of Water Quality Data at the Influent of Daejeon Wastewater Treatment Plant)

  • 박기정;정민재;이한샘;김덕우;윤재영;백경록
    • 한국물환경학회지
    • /
    • 제28권1호
    • /
    • pp.38-49
    • /
    • 2012
  • In this study, we analyze statistical characteristics of influent water quality in Daejeon waste water treatment plant and apply a stochastic model for data generation. In the analysis, the influent water quality data from year 2003 to 2008, except for year 2006, are used. Among water quality variables, we find strong correlations between BOD and T-N; T-N and T-P; BOD and T-P; $COD_{Mn}$ and T-P; and BOD and $COD_{Mn}$. We also find that different water quality variables follow different theoretical probability distribution functions, which also depends on whether the seasonal cycle is removed. Finally, we generate the influent water quality data using the multi-season 1st Markov model (Thomas-Fiering model). With model parameters calibrated for the period 2003~2005, the generated data for 2007~2008 are well compared with observed data showing good agreement in general. BOD and T-N are underestimated by the stochastic model. This is mainly due to the statistical difference in observed data itself between two periods of 2003~2005 and 2007~2008. Therefore, we expect the stochastic model can be applied with more confidence in the case that the data follows stationary pattern.

방류수질 예측을 위한 AI 모델 적용 및 평가 (Application and evaluation for effluent water quality prediction using artificial intelligence model)

  • 김민철;박영호;유광태;김종락
    • 상하수도학회지
    • /
    • 제38권1호
    • /
    • pp.1-15
    • /
    • 2024
  • Occurrence of process environment changes, such as influent load variances and process condition changes, can reduce treatment efficiency, increasing effluent water quality. In order to prevent exceeding effluent standards, it is necessary to manage effluent water quality based on process operation data including influent and process condition before exceeding occur. Accordingly, the development of the effluent water quality prediction system and the application of technology to wastewater treatment processes are getting attention. Therefore, in this study, through the multi-channel measuring instruments in the bio-reactor and smart multi-item water quality sensors (location in bio-reactor influent/effluent) were installed in The Seonam water recycling center #2 treatment plant series 3, it was collected water quality data centering around COD, T-N. Using the collected data, the artificial intelligence-based effluent quality prediction model was developed, and relative errors were compared with effluent TMS measurement data. Through relative error comparison, the applicability of the artificial intelligence-based effluent water quality prediction model in wastewater treatment process was reviewed.

확률밀도함수 기반 유입하수 재현 및 활성슬러지공정 설계기법 개발 (Development of Application Method of Influent Wastewater Generation and Activated Sludge Process Design Based on Probability Density Function)

  • 유광태;김종락;윤주환;박기정
    • 한국물환경학회지
    • /
    • 제33권2호
    • /
    • pp.140-148
    • /
    • 2017
  • An important factor in determining the design and treatment efficiency of wastewater treatment plants (WWTPs) is the quantity and quality of influent. These detailed and accurate information is essential for process control, diagnosis and operation, as well as the basis in designing the plant, selecting the process and determining the optimal capacity of each bioreactor. Probabilistic models are used to predict the wastewater quantity and quality of WWTPs, which are widely used to improve the design and operation of WWTPs. In this study, the optimal probability distribution of time series influent data was derived for predicting water quantity and quality, and wastewater influent data were generated using the Monte Carlo simulation analysis. In addition, we estimated various alternatives for the improvement of bioreactor operations based on present operation condition using the generated influent data and activated sludge model, and suggested the alternative that can operate the most effectively. Thus, the influent quantity and quality are highly correlated with the actual operation data, so that the actual WWTPs influent characteristics were well reproduced. Using this will improve the operating conditions of WWTPs, and a proposed improvement plan for the current TMS (Tele Monitoring System) effluent quality standards can be made.

단계 주입 활성슬러지공법에서 질소제거를 위한 반응기 용적비 추정 (Estimation of the Reactor Volume Ratio for Nitrogen Removal in Step-Feed Activated Sludge Process)

  • 이병대
    • 한국응용과학기술학회지
    • /
    • 제23권2호
    • /
    • pp.130-136
    • /
    • 2006
  • Theoretical total nitrogen removal efficiency and reactor volume ratio in oxic-anoxic-oxic system can be found by influent water quality in this study. The influent water quality items for calculation were ammonia, nitrite, nitrate, alkalinity, and COD which can affect nitrification and denitrification reaction. Total nitrogen removal efficiency depends on influent allocation ratio. The total nitrogen removal follows the equation of 1/(1+b). Optimal reactor volume ratio for maximum TN removal efficiency was expressed by those influent water quality and nitrification/denitrification rate constants. It was possible to expect optimal reactor volume ratio by the calculation with the standard deviation of ${\pm}14.2$.

미나리꽝을 이용한 영양물질제거에 관한 연구 (A Studies on Removal of Nutrient Material by Using Dropwort Field)

  • 이영신;김창회
    • 한국환경보건학회지
    • /
    • 제29권3호
    • /
    • pp.16-20
    • /
    • 2003
  • Nitrogen(N) and phosphorus(P) in surface streams mainly lead to euthrophication. It aggravates water quality and consequently increases the purification costs. As a resolution of water contamination caused by household drainage through irrigation route by 70% of the 1,300 community residents in Eum-Am Myun, Seo-San city, was implemented biological self-purification method by growing Oenanthe Javanica along the polluted water tunnel. The contaminated water was efficiently purified after passing the dropwort field; DO conc. of effluent water was increased 8.3∼61.9% after through the drop wort field. HRT of experiment system was changed 0.05∼1.50/day. 50% of BOD was eliminated at the range above 12 mg/l of Influent BOD conc. Also, 50% of COD was eliminated at the range above 30 mg/l of Influent COD conc. Finnally, the influent T-N loading at range below 1.5 g/m$^3$/d reduced 50% of Influent T-N conc., and so did influent T-P loading at the range below 0.03 g/m$^3$/dwas reduced 50% of Influent T-P conc.

백운산 지역에서 계류수의 이화학적 성질에 미치는 양어장의 영향(III) (Influences of Fish Farm on the Physicochemistry of Stream Water Quality in Mt. Baegun Area(III))

  • 박재현
    • 한국환경복원기술학회지
    • /
    • 제4권4호
    • /
    • pp.46-55
    • /
    • 2001
  • Analysis of fish farm influences on stream water quality may provide basic informations on watershed management to reduce environmental impact due to fish farm development and to conserve stream water quality in forested watershed area. In this research stream water qualities around Mt. Baegun area were monitored seasonally for three years. Due to the increase of pH in effluent water from the fish farm it was believed that alkalization of stream water can be accelerated by large scale development of fish farms in the forested watershed area. As a result of regression analyses, the linear equation of pH of influent and effluent water of fish farm was, pH of effluent water of fish farm = $0.6234{\times}pH$ of influent water of fish farm + 2.6263. Also, the linear equation of electrical conductivity of influent and effluent water of fish farm was electrical conductivity of effluent water of fish farm = $1.7275{\times}$electrical conductivity of influent water of fish farm - 14.007. Negative effects on stream water quality were observed by indications of increase in electrical conductivity and water temperature of effluent water from the fish farm. Decreases in physicochemical indices such as the amount of dissolved oxygen, total amount of cation and total amount of anion in effluent water from the fish farm were also negative aspects in downstream ecology. It is recommended that water purification system as well as environmentally-friendly fish farm design should be incorporated to large scale fish farm development plan in forested watershed area.

  • PDF

강우 및 유입 하천수가 팔당호 수질에 미치는 영향분석 (A Study on the Water Quality Affected by the Rainfall and Influent Rivers in Paldang Reservoir, Korea)

  • 김종민;노혜란;허성남;양희정;박준대
    • 한국물환경학회지
    • /
    • 제21권3호
    • /
    • pp.277-283
    • /
    • 2005
  • This paper aimed to compare the daily water quality as well as the hydrological data gathered for the past two years (2000 to 2001) between the two influent rivers of Paldang reservoir. The analysis also has been carried out to draw out the factors that affect the water quality at the dam site, where the main drinking water drawing point is located. The relationship between total amount of monthly rainfall and monthly inflow showed $r^2=0.74$ (p<0.05). The highest peak of inflow of influent rivers recorded in August and September (in the year of 2000) and July and August (2001). Average inflows of influent rivers in 2000 and 2001 are calculated at 209.0, 161.5 CMS (Bughangang), 268.6, 148.2 CMS(Namhangang), and 7.8, 5.0 CMS (Gyeongancheon). The formula which was driven from the relationship between inflow and COD load of influent rivers, explained that COD concentration in general increased with the inflow. But during the rainy seasons (July, August, and September), COD concentration decreased according to the increase of inflow. The daily rainfall and COD concentration(or load) during the rainy season (August and September in the year of 2000, July and August in 2001) indicated that the peak of COD load correspond with the rainfall, which decreased sharply after 3 or 4 days. The reason was thought that the high COD load was diluted rapidly by the rain flow. Water temperature, pH and conductivity measured at dam site decreased obviously when the inflow sharply increased. Peak period of total phosphorus concentration coincided with that of inflow. In rainy season, chlorophyll-a concentration decreased obviously as the inflow increased. The reason can be ascribed to the flushing effect caused by the operation of floodgate.

연안해수와 지하해수를 사용하는 제주 넙치 양식장의 수질과 미생물 변동 (Investigation of water qualities and microbials on the flow-through olive flounder, Paralichthys olivaceus farms using coastal seawater and underground seawater in Jeju)

  • 김유희
    • 수산해양기술연구
    • /
    • 제58권1호
    • /
    • pp.59-67
    • /
    • 2022
  • This study assessed the levels of water qualities and microbials contamination of inland olive flounder farms in Jeju in the summers from 2015 to 2017. Three farms (A-C) located in a concentrated area using mixing coastal seawater and underground seawater and one farm (D) located in an independent area using only coastal seawater were selected. Total ammonia nitrogen (TAN) reached a maximum of 0.898 ± 1.024 mg/L as N in the coastal seawater of A-C, which was close to the limit of the water quality management goal of the fish farm. TAN in the influent from A-C was up to three times higher than that of D, so that the discharged water did not spread to a wide range area along the coast and continued to affect the influent. TAN of the effluent in A-C increased by 2.7-4.6 times compared to the influent, resulting in serious self-pollution in the flounder farm. Heterotrophic marine bacteria in the influent of A-C was about 600 times higher than D, and the discharge of A-C was increased by about 30 times compared to the influent.

공동주택 지하저수조의 수질변화 및 부식성 특성 (Water Quality Variation and Corrosion Index Characteristics of Underground Reservoir in Apartment)

  • 장준영;김주원;황유훈;김기팔;신현상;임병란
    • 한국물환경학회지
    • /
    • 제38권6호
    • /
    • pp.275-281
    • /
    • 2022
  • To maintain water quality after water treatment, monitoring whether the quality of treated tap water quality changes is essential. However, current investigations are insufficient to prevent secondary contamination in drinking water supply systems. This study investigated Gyeonggi's e apartment where a red water problem occurred and monitored the water quality and corrosiveness of the overall water supply system to the apartment from June 2021 to April 2022. In a comparison of drinking water quality after water treatment and the influent of the reservoir, turbidity and heavy metal concentrations were increased and residual chlorine was decreased due to increases in temperature. Correlation analysis and principal component analysis (PCA) indicated that a low level of residual chlorine may cause the abscission of Mn2+ and Fe2+ through microorganism activation, which also causes a high level of turbidity. The corrosion index (LI) in the influent of the reservoir tank was increased due to Ca2+ and temperature. These results indicate that the corrosiveness of drinking water and the deterioration of drinking water quality were mainly increased between the drinking water treatment plant and the reservoir tank's influent. The findings provide clear evidence that it is essential to manage water supply systems and reservoir tanks to prevent the secondary contamination of drinking water.