A study of improvement of river water quality(T-P) in pilot-scale operation (파일롯 규모의 운영에 따른 하천수질(T-P) 개선에 관한 연구)

  • Choi, Kyoungsoo;Lee, Chaeyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.5
    • /
    • pp.323-334
    • /
    • 2021
  • Pilot-scale coagulation and sedimentation processes were operated to investigate the T-P (Total phosphorus) removal efficiency. A multiple regression model was also derived to predict the water quality improvement effect with river water characteristics. The inflow rates for the pilot-scale facility were 157-576 m3/day, and the coagulant doses were in the range of 13.7-58.5 mg/L (average 38.9 mg/L) for PAC (Poly alum chloride) and 16.5-62.1 mg/L (average 36.0 mg/L) for alum. The results found that the influent BOD (Biochemical oxygen demand) and T-P concentrations were 4.9 mg/L and 0.115 mg/L, and the removal efficiencies were 52.7% and 59.4%, respectively. T-P removal efficiencies on wet weather days were higher by 10% than dry weather days because influent solids influenced T-P's coagulation process. The pH of river water was 6.9-7.8, and the average pH was 7.3. Although the pH variation was not significant, the trend showed that the treatment efficiency of T-P and PO4-P removal increased. Thus, the pH range considered in this study seems to be appropriate for the coagulation process, which is essential for phosphorous removal. The T-P removal efficiencies were 19.6-93.3% (average 59.2%) for PAC and 16.4-98.5%(average 55.9%) for alum; thus, both coagulants showed similar results. Furthermore, the average coagulant doses were similar at 42.4 mg/L for PAC and 41.3 mg/L for alum. When the T-P concentration of the effluent was compared by the [Al]/[P] ratio, the phosphorus concentration of the treated water decreased with an increasing [Al]/[P] ratio, and the lowest T-P concentration range appeared at the [Al]/[P] ratio of 10-30. A seasonal multiple regression analysis equations were derived from the relationships between 10 independent and dependent variables (T-P concentration of effluent). This study could help lake water quality maintenance, reduce eutrophication, and improve direction settings for urban planning, especially plans related to developing waterfront cities.

Analysis on the Runoff Reduction Efficiency of Non Point Pollutants in Animal Feeding Area Using Artificial Reservoir (인공 저류지를 이용한 축산 지역 비점오염물질 유출 저감 효율 분석)

  • Oa, Seong-Wook
    • Journal of Wetlands Research
    • /
    • v.20 no.4
    • /
    • pp.417-423
    • /
    • 2018
  • It analyzed the efficiency of the runoff reduction of artificial reservoir by analyzing the influent and effluent of reservoir located downstream of the livestock area. Production of non point pollutants in livestock feeding areas, which is located at steep slope land, was mainly due to first flushes. Suspended Solid concentration of influent increased due to amount of rainfall, and T-P also increased over four times and 30 % of total nitrogen increased on average compared to those of dry season. While the concentration of nitrate nitrogen showed little variation, ammonia nitrogen increased over two times. The storage style nonpoint reduction facility showed the highest removal efficiency of 53 % for total phosphorus in dry weather, when the removal efficiency was 37 % for suspended solids, 10% for organic compounds, and 5 % for total nitrogen. Since algal bloom grows due to eutrophication in summer, the minus removal efficiencies of nitrogen concentration through the reservoir occurred with high frequency. Removal efficiency decreased during rainfall, showing 60 % for supended solids, and 22 % for total phosphorus. While having over nine times of capacity than the standard of non-point removal facility from Ministry of Environment, it was impounded with water during rainy season, showing not enough nonpoint removal efficiency, which indicates that maintenance is also an important factor to the nonpoint removal efficiency.

Advanced Sewage Treatment by the Modified SBR(Sequencing Batch Reactor) Process (변형 연속회분식 반응기를 이용한 오수의 고도처리)

  • 김병군;서인석;홍성택;정위득
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.3
    • /
    • pp.46-51
    • /
    • 2002
  • This study was performed to treat a sewage at the upper stream of dam using modified sequencing batch reactor, During the operating period, average $COD_{cr}$, removal efficiency was about 85% but average T-N and ${PO_4}^{3-}-P$ removal efficiencies were 43% and 30% respectively. Because the organic matter was very low compared with nitrogen and phosphorous in influent($BOD_{5}/{NH_4}^{+}-N{\;}={\;}2,{\;}BOD_{5}/{PO_4}^{3-}-P{\;}={\;}15.6$), nitrogen and phosphorus removal efficiency was relatively low. Average nitrogen removal efficiency was 50 % at $10^{\circ}C$ or above and it was 36 % at $10^{\circ}C$ or below. As reactor was located in outdoor without any thermostat, temperature decreased at least $2.4^{\circ}C$ in the winter season. Therefore, if we would apply this modified sequencing batch reactor to sewage which concentration of organic matter was very low compared with nitrogen and phosphorous, we have to addition of external carbon and installation of any thermostat.

Treatment Characteristics of Wastewater with Flow Rate Variation in Anaerobic-Aerobic Activated Sludge Process

  • Lee Min-Gyu;Suh Kuen-Hack;Hano Tadashi
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.1 no.1
    • /
    • pp.11-17
    • /
    • 1997
  • The treatment performances of anaerobic-aerobic activated sludge process were investigated under various operation conditions. The treatment system proposed in this study gave a relatively stable performance against hourly change of the flow rate and showed a satisfactory removal efficiency of nitrogen and phosphorus compounds under experimental conditions. The average removal efficiency of total nitrogen gradually decreased as the influent total nitrogen concentration was increased. High C/N ratio of the wastewater was required for the complete removal of nitrogen. Glucose as a carbon source was more efficient than starch and the removal ability for all components become higher with the increase of the fraction of glucose.

  • PDF

Treatment Characteristics of Wastewater with Flow Rate Variation in Anaerobic-Aerobic Activated Sludge Process

  • Min-Gyu Lee;Kue
    • Journal of Environmental Science International
    • /
    • v.1 no.1
    • /
    • pp.11-17
    • /
    • 1992
  • The treatment performances of anaerobic-aerobic activated sludge Process were investigated under various operation conditions. The treatment system proposed in this study gave a relatively stable performance against hourly change of the flow rate and showed a satisfactory removal efficiency of nitrogen and phosphorus compounds under experimental conditions. The average removal efficiency of total nitrogen gradually decreased as the influent total nitrogen concentration was increased. High C/N ratio of the wastewater was required for the complete removal of nitrogen. Glucose as a carbon source was more efficient than starch and the removal ability for all components become hither with the increase of the fraction of glucose.

  • PDF

Change of Nutrients and Behaviour of Total Coliforms in the Natural Treatment of Wastewater by Subsurface Flow Wetland System (인공습지를 이용한 자연정화 오수처리시설에서 영양물질의 변화와 대장균군의 행동)

  • Yoon, Chun-Gyeong;Kwun, Soon-Kuk;Kim, Hyung-Joong
    • Korean Journal of Environmental Agriculture
    • /
    • v.16 no.3
    • /
    • pp.249-254
    • /
    • 1997
  • The constructed wetland system which is applicable to rural wastewater treatment was examined by pilot plant experiment. Removal rates of nutrients including nitrogen and phosphorus and total coliform were evaluated. The $NH_4\;^+$ concentration of the influent was in the range of 91.57 to 275.88mg/l and the effluent concentration was about 40% lower than the influent. The decreasing of the $NH_4\;^+$ concentration might be due to volatilization, plant uptake, adsorption onto soil particles, and mainly nitrification. However, generally concentrations of $NO_2\;^-$ and $NO_3\;^-$ were increased in the effluents compared to the influent concentrations, which implies that nitrogen components in the system were nitrified. Overall, the average removal rate of the nitrogen was about 5% which seems inadequate as a wastewater treatment system, and this system needs improvement on nitrogen removal mechamism. The removal rate of the phosphorus was quite high and effluent concentration was very low. Reason for high removal rate of the phosphorus might be mainly strong adsorption characteristic onto soil particles. The average removal rate of the total coliforms was about 83%, and main removal mechanisms are thought to be adsorption onto soil and inability to compete against the established soil microflora. From the results of the study, the constructed wetland system needs to be improved in nitrogen removal mechanism for field application.

  • PDF

Removal Behavior of Biological Nitrogen and Phosphorus and Prediction of Microbial Community Composition with Its Function, in an Anaerobic-Anoxic System form Weak Sewage

  • LEE, JIN WOO;EUI SO CHOI;KYUNG IK GIL;HAN WOONG LEE;SANG HYON LEE;SOO YOOUN LEE;YONG KEUN PARK
    • Journal of Microbiology and Biotechnology
    • /
    • v.11 no.6
    • /
    • pp.994-1001
    • /
    • 2001
  • An easier way of understanding the BNR system was proposed from the study on substrate, nutrient removal tendency, microbial community and its metabolic function by applying the municipal settled sewage. During the anaerobic period, the phosphorus release rate per VFACOD we varied depending on the phosphorus content in the sludge. When the phosphorus content in the sludge was $6\%$ VSS, according to influent VFACOD, the phosphorus release rate and PHA production were $0.35 gPO_4P/gVFACOD$ and 1.0 gPHA/gVFACOD, respectively. The $NO_3N$ requirement for the phosphorus uptake as an electron acceptor was about $0.5 gNO_3N/gPO_4P_{uptake}$ based on the proposed equation with PHA, biomass, production, and the concentration of phosphorus release/uptake. Bacterial-community analysis of the sludge, as determined by FISH and 16SrDNA characterization FISH, revealed that the beta-subclass proteobacteria were the most abundant group ($27.9\%$ of the proteobacteria-specific probe EUB338), and it was likely that representative of the beta-subclass played key roles in activated sludge. The next dominant group found was the gamma-protebacteria ($15.4\%$ of probe EUB338). 16S rDNA clone library analysis showed that the members of${\beta}$- and ${\gamma}$-proteobacteria were also the most abundant groups, and $21.5\%$ (PN2 and PN4) and $15.4\%$ (PN1 and PN5) of total clones were the genera of denitrifying bacteria and PAO, respectively. Prediction of the microbial community composition was made with phosphorus content (Pv, $\%$ P/VSS) in wasted sludge and profiles of COD, PHA, $PO_4P,\;and\;NO_3N$ in an anaerobic-anoxic SBR unit. Generally, the predicted microbial composition based upon metabolic function, i.e., as measured by stoichiometry, is fairly similar to that measure by the unculturable dependent method. In this study, a proposal was made on he microbial community composition that was more easily approached to analyze the reactor behavior.

  • PDF

Enhanced total phosphorus removal using a novel membrane bioreactor by sequentially alternating the inflow and by applying a two-stage coagulation control based on pre-coagulation (유입흐름 변경 및 전응집 기반 이단응집 제어 적용 MBR을 통한 총인처리 개선 연구)

  • Cha, Jaehwan;Shin, Kyung-Suk;Park, Seung-Kook;Shin, Jung-Hun;Kim, Byung-Goon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.1
    • /
    • pp.103-114
    • /
    • 2017
  • A membrane bioreactor by sequentially alternating the inflow and by applying a two-stage coagulation control based on pre-coagulation was evaluated in terms of phosphorus removal efficiency and cost-savings. The MBR consisted of two identical alternative reaction tanks, followed by aerobic, anoxic and membrane tanks, where the wastewater and the internal return sludge alternatively flowed into each alternative reaction tank at every 2 hours. In the batch-operated alternative reaction tank, the initial concentration of nitrate rapidly decreased from 2.3 to 0.4 mg/L for only 20 minutes after stopping the inflow, followed by substantial release of phosphorus up to 4 mg/L under anaerobic condition. Jar test showed that the minimum alum doses to reduce the initial $PO_4$-P below 0.2 mg/L were 2 and 9 mol-Al/mol-P in the wastewater and the activated sludge from the membrane tank, respectively. It implies that a pre-coagulation in influent is more cost-efficient for phosphorus removal than the coagulation in the bioreactor. On the result of NUR test, there were little difference in terms of denitrification rate and contents of readily biodegradable COD between raw wastewater and pre-coagulated wastewater. When adding alum into the aerobic tank, alum doses above 26 mg/L as $Al_2O_3$ caused inhibitory effects on ammonia oxidation. Using the two-stage coagulation control based on pre-coagulation, the P concentration in the MBR effluent was kept below 0.2 mg/L with the alum of 2.7 mg/L as $Al_2O_3$, which was much lower than 5.1~7.4 mg/L as $Al_2O_3$ required for typical wastewater treatment plants. During the long-term operation of MBR, there was no change of the TMP increase rate before and after alum addition.

Removal of Nutrients Using an Upflow Septic Tank(UST) - Aerobic Filter(AF) System (부패조와 호기성 여과공정을 이용한 영양염류 제거)

  • Park, Sang-Min;Jun, Hang-Bae; Bae, Jong-Hun;Park, Woo-Kyun;Park, Noh-Back
    • Korean Journal of Environmental Agriculture
    • /
    • v.29 no.3
    • /
    • pp.232-238
    • /
    • 2010
  • The objective of this study was to investigate a small sewage treatment system. This system was developed to improve a nitrogen and phosphorus removal efficiency and generate less solid using upflow septic tank(UST) - aerobic filter(AF) system. The UST equipped with an aerobic filter, the filter was fed with both raw sewage and recycled effluent from the UST to induce the denitrification and solid reduction simultaneously. Overall removal efficiencies of COD and total nitrogen(TN) were above 96% and 73% at recycle ratio of 200%, respectively. Critical coagulant dose without the biochemical activity was found to be 40 mg/L. Removal efficiency of total phosphorus(TP) in influent was above 90% by chemical and biological reactions. Although the phosphorus concentration was low under the high alkalinity in raw sewage, the pH value was unchanged by the coagulant dose.

Study on Change of Microbial Activity and Removal Efficiency of Phosphorus with Alum Injection in the Biological Process (생물학적 처리공정 내 Alum 주입에 따른 인 처리 효율과 미생물 활성도 변화에 관한 연구)

  • Choi, Jung Su;Joo, Hyun Jong
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.2
    • /
    • pp.188-193
    • /
    • 2011
  • The effects of coagulants on the microorganisms when they are injected directly into the biological treatment facility for T-P removal have been easily observed from the results of past experiments. As such this study is set out to derive the effective plans for the coagulant dosage by analyzing the effects of the injected coagulant on the microbial activity during the chemical treatment for T-P removal. The research methods entailed the assessment of removal efficiency of T-P according to the coagulant dosage while changing the molar ration between Alum and influent phosphorus. At the same time Specific Oxygen Uptake Rate (SOUR) according to the coagulant dosage was measured. SOUR was used as a method for indirect assessment of the microbial activity according to the coagulant dosage. The results from the study showed that with the increase in the alum dosage, the removal efficiency T-P tended to increase. On the other hand, the increase in coagulant dosage resulted in the decrease in SOUR, which indicates the decrease in the microbial activity. Such reduction in the activity could be explained by the increase in the concentration of removal efficiency of $TBOD_5$. Based on experiment results from the study, it is determined that coagulant dosage affects the microbial activity. Moreover, the indirect assessment on the microbial activity using SOUR is considered possible.