• 제목/요약/키워드: Influent phosphorus concentration

검색결과 59건 처리시간 0.028초

SBR과 SBBR에서 유입 인 농도 감소에 따른 인과 질소의 제거 특성 변화 (Variation of Phosphorus and Nitrogen Removal Characteristics According to the Decrease of Influent Phosphorus Concentration in SBR and SBBR)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제19권4호
    • /
    • pp.483-490
    • /
    • 2010
  • The purpose of this study is to investigate the effect of influent phosphorus concentration on the nitrogen and phosphorus removal in sequencing batch reactor(SBR) and sequencing batch biofilm reactors(SBBRs) in order to recover the enhanced biological phosphorus removal (EBPR) capacity at the sludge of the deterioration of EBPR capacity. In SBBRs, comparing to SBR, the organic removal was occurred actively at the 1 st non-aeration period because of the active phosphorus release at this period. However, the variation of TOC removal according to the decrease of influent phosphorus concentration was not clearly shown both in SBR and SBBRs. In case of SBR losing EBPR capacity, the EBPR capacity was not recovered by the decrease of the influent phosphorus concentration from 7.5 mg/L to 0.9 mg/L. The nitrogen removal increased by the decrease of influent phosphorus concentration both in SBR and SBBRs.

소규모 오수처리를 위한 $A_{2}O$ SBR과 $A_{2}O$ SBBR에서 유입 유기물 농도변화에 따른 염양염류 제거 특성 비교 (A Comparison of Nutrients Removal Characteristics by the Variation of Organics in $A_{2}O$ SBR and $A_{2}O$ SBBR for the Small Sewerage System)

  • 박영식;정노성;김동석
    • 한국환경보건학회지
    • /
    • 제32권5호
    • /
    • pp.451-461
    • /
    • 2006
  • Laboratory scale experiments were conducted to study the conversion of sludge from conventional activated sludge to nitrogen-phosphorus removal sludge using two types of sequencing batch reactor (SBR) systems, a conventional SBR and sequencing batch biofilm reactor (SBBR). The nitrogen and phosphorus removal characteristics were similar between SBR and SBBR and the removal efficiencies were very low when the influent TOC concentrations were low. The nitrogen and phosphorus removal efficiencies in SBR were 96% and 77.5%, respectively, which were higher than those in SBBR (88% and 42.5%) at the high influent TOC concentration. In SBBR, the simultaneous nitrification-denitrification was occurred because of the biofilm process. The variations of pH, DO concentration and ORP were changed as the variation of influent TOC concentration both in SBR and SBBR and their periodical characteristics were cleary shown at the high influent TOC concentration. Especially, the pH, DO concentration and ORP inflections, were cleary occurred in SBR compared with SBBR.

A/O 및 A2/O공정의 생물학적 인제거 특성비교 (Comparison of Biological Phosphorus Removal Characteristics between A/O and A2/O Process)

  • 김광수;서규태;이경호;김낙주
    • 한국물환경학회지
    • /
    • 제18권2호
    • /
    • pp.123-130
    • /
    • 2002
  • Bench scale experiments were carried out with two biological nutrient removal(BNR) units, A/O and $A^2O$ processes, to investigate the behavior of phosphorus in the system and to compare the characteristics of phosphorus removal in two BNR processes. To achieve this goal, COD/T-P and COD/TKN ratios of the influent was varied in the range of 23~64 and 5~24, respectively. In A/O process, influent COD/T-P ratio should be kept higher than 44mg/L to meet the final effluent T-P concentration lower than 1mg/L and in $A^2/O$ process, influent COD/T-P and COD/TKN ratios higher than 56 and 10, respectively, were required for good phosphorus release and uptake with no influence of nitrate nitrogen in return sludge. At this conditions, the rate of phosphorus release in the anaerobic basin should be kept higher than 0.1 kg S-P/kg MLVSS d In A/O process, the phosphorus content of anaerobic and aerobic sludges was increased as SRT of total system was becoming longer resulting in decreasing the difference of phosphorus content between two sludges while phosphorus release in anaerobic basin and phosphorus uptake in aerobic basin was not incident. In $A^2/O$ process, the phosphorus content of anaerobic and aerobic sludges were not increased with higher SRT of total system due to the relatively high nitrate concentration in return sludge. However, the difference of phosphorus content between anaerobic and aerobic sludges was incident when phosphorus release and uptake was observed.

호기 조건에서 DPAOs (Denitrifying Phosphorus Accumulation Organisms)에 의한 인 제거 (Phosphorus Removal by DPAOs (Denitrifying Phosphorus Accumulating Organisms) in Aerobic Condition)

  • 정노성;박영식;김동석
    • KSBB Journal
    • /
    • 제25권1호
    • /
    • pp.62-66
    • /
    • 2010
  • 호기 상태에서 ${NO_X}^-$-N이 PAOs에 의한 인 흡수속도에 미치는 영향을 각기 세 가지 조건의 회분식 실험을 통하여 관찰하였다. 실험 결과를 요약하면 다음과 같다. 1) 인 과잉흡수가 이루어지는 호기 상태에서 PAOs는 ${NO_X}^-$-N에 의해 인 흡수에 방해를 받는 것으로 나타났다. 2) 인 흡수속도에 있어 ${NO_3}^-$-N보다 같은 농도의 ${NO_2}^-$-N가 PAOs의 인 흡수속도를 저하시키는 결과를 나타내었다. 10 mg/L의 같은 농도로 유입되었음에도 불구하고 ${NO_2}^-$-N에 의한 인 흡수속도는 15.61 mg/gVSS로 10 mg/L의 ${NO_3}^-$-N가 공급된 실험에서의 인 흡수속도 28.30 mg/gVSS보다 낮은 속도를 나타냈다. 3) 반응기내의 ${NO_2}^-$-N 농도가 2 mg/L 이상으로 존재할 시 PAOs의 인 흡수속도는 ${NO_X}^-$-N가 존재하지 않는 조건에서 인 흡수 속도의 24%를 나타냈으며, ${NO_3}^-$-N의 농도가 3 mg/L 이상으로 존재할 경우 ${NO_X}^-$-N가 존재하지 않는 조건에서 인 흡수 속도의 17% 이하로 감소하는 것으로 나타나 ${NO_2}^-$-N가 PAOs의 인 흡수에 심각한 저해를 미치는 것으로 나타났다. 4) 반응기내에 ${NO_2}^-$-N와 ${NO_3}^-$-N가 함께 존재할 시에는 ${NO_X}^-$-N가 존재하지 않는 조건에서 인 흡수 속도의 6% 이하로 감소하는 것으로 나타났다. 5) ${NO_2}^-$-N는 EBPR의 붕괴에 영향을 미치는 중요한 요소로 판명되었다.

분류식 하수관거로의 전환시 유입하수의 성상 변화 및 선회와류식 SBR공법의 처리 특성 (Change in Influent Concentration of Domestic Wastewater from Separated Sewer and Biological Nitrogen and Phosphorus Removal of a Full Scale Air-vent SBR)

  • 이장희;강호
    • 한국물환경학회지
    • /
    • 제28권1호
    • /
    • pp.63-70
    • /
    • 2012
  • This study was carried out to investigate change in influent concentration of domestic wastewater flowed from a newly constructed separate sewer system (SSS) and biological nutrients removal efficiency of a full scale Air-vent sequential batch reactor (SBR, $600m^3/d$). The average concentration of $BOD_5$, SS, T-N and T-P from SSS were 246.5 mg/L, 231.6 mg/L, 42.974 mg/L, 5.360 mg/L, respectively which corresponds to 2.2times, 1.2times, 1.8times and 2.1times higher than those from the conventional combined sewer system (CSS). The removal efficiency of $BOD_5$, SS, T-N, and T-P for the Air-vent SBR operated with influent from SSS averaged 99.1%, 99.0%, 91.2%, and 93.5%, respectively. Especially the respective nitrogen and phosphorus removal was 15% greater than that of the SBR operated with influent from CSS. Simultaneous nitrification and denitrification (SND) was observed in an aerobic reactor(II) as a result of DO concentration gradient developed along the depth by the Air-vent system. In order to achieve T-N removal greater than 90%, the C/N ratio should be over 6.0 and the difference between $BOD_5$ loading and nitrogen loading rate be over 100 kg/day (0.130 kg $T-N/m^3{\cdot}d$). Even with high influent T-P concentration of 5.360 mg/L from SSS (compared with 2.465 mg/L from CSS) T-P removal achieved 93.5% which was 15.5% higher than that of the SBR with influent from CSS. This is probably due to high influent $BOD_5$ concentration from SSS that could provide soluble carbon source to release phosphorus at anaerobic condition. In order to achieve T-P removal greater than 90%, the difference between $BOD_5$ loading and phosphorus loading rate should be over 100 kg /day (0.130 kg $T-N/m^3{\cdot}d$).

폐굴껍질에 의한 합성폐수 중의 인 제거 (Phosphorus Removal from Synthetic Wastewater by Waste Oyster Shells)

  • 정경훈;정오진;최형일
    • 한국환경보건학회지
    • /
    • 제26권3호
    • /
    • pp.43-49
    • /
    • 2000
  • A laboratory experiments were performed to investigate the effects of several factors on the phosphorus removal by waste oyster shells. The waste oyster shells used in this experiments were crushed particle, calcined particle and extracted solution. A higher efficiencies of phosphorus removal were observed, when a particle size of crushed and calcined particle were smaller. The effluent concentration of phosphorus was around 1.6mg/ι in continuous column experiment which packed with crushed particle of waste oyster shell at the influent concentration of PO4-P of 10 mg/ι. But the clogging of column occurred with increasing of throughput volume of influent. The efficiency of phosphorus removal increased with increasing of dosage amount of crushed, calcined particle and extracted solution. When the calcined particle which contained only about 1/10~1/100 of crushed particle was used, the efficiency of phosphorus removal was correspondingly equivalent to the removal efficiency obtained from crushed particle. The efficiency of phosphorus removal by calcined particle after 9 runs repeated use was decreased about 21.5% as that of the first run. The removal efficiency of 100% could have been achieved at the HRT of 18 hours during the continuous treatment of phosphorus by the solution extracted from calcined particle.

  • PDF

철전기분해장치(FNR)에서 단위공정에 따른 질소와 인의 제거 (A Study on Phosphorus and Nitrogen Removal with Unit Operation in the Ferrous Nutrient Removal Process)

  • 김수복;김영규
    • 한국환경보건학회지
    • /
    • 제39권1호
    • /
    • pp.83-89
    • /
    • 2013
  • Objectives: The purpose of this experiment was to illuminate the relationship between the phosphorus removal rate of unit operation and the phosphorus removal rate of phosphorus volume loading in the Ferrous Nutrient Removal process, which consists of an anoxic basin, oxic basin, and iron precipitation apparatus. Methods: This study was conducted in order to improve the effect of nitrogen and phosphorus removal in domestic wastewater using the FNR (Ferrous Nutrient Removal) process which features an iron precipitation reactor in anoxic and oxic basins. The average concentration of TN and TP was analyzed in a pilot plant ($50m^3/day$). Results: The removal rate of T-N and T-P were 66.5% and 92.8%, respectively. The $NH_3-N$ concentration of effluent was 2.62 mg/l with nitrification in the oxic basin even though the influent was 17.7 mg/l. The $NO_3$-N concentration of effluent was 5.83 mg/l through nitrification in oxic basin even though the influent and anoxic basin were 0.82 mg/l and 1.00 mg/l, respectively. The specific nitrification of the oxic basin ($mg.NH_3$-Nremoved/gMLVSSd) was 16.5 and specific de-nitrification ($mg.NO_3$-Nremoved/gMLVSSd) was 90.8. The T-P removal rate was higher in the oxic basin as T-P of influent was consumed at a rate of 56.3% in the anoxic basin but at 90.3% in the oxic basin. The TP removal rate (mg.TP/g.MLSS.d) ranged from 2.01 to 4.67 (3.06) as the volume loading of T-P was increased, Conclusions: The test results showed that the electrolysis of iron is an effective method of phosphorus removal. Regardless of the temperature and organic matter content of the influent, the quality of phosphorus in the treated water was both relatively stable and high due to the high removal efficiency. Nitrogen removal efficiency was 66.5% because organic matter from the influent serves as a carbon source in the anoxic basin.

하수처리수 재이용을 위한 실규모 입상황 생물막여과 시설의 효율증대 방안에 관한 연구 (A Study by Proposal of Efficiency Increase for a Full-scale Wastewater Reclamation Facility using a Biofilter Packed with Granular Sulfur)

  • 문진영;황용우;백승륜
    • 상하수도학회지
    • /
    • 제24권1호
    • /
    • pp.73-83
    • /
    • 2010
  • This study was performed to increase the removal efficiency of the biofilter packed with granular sulfur in municipal wastewater reclamation facility. Constituent units were influent water tank, denitrification tank, BOD reduction tank and outlet. And, the major operation factor is a biofilter packed with submerged granular sulfur. Actual wastewater and synthetic wastewater were used as influent wastewater. Experimental condition was divided into two phases according to the amount of a phosphorus coagulant. Total phosphorus removal efficiency was insignificant at mode I that phosphorus coagulant was not injected. The average influent and effluent total phosphorus concentrations at mode II were 0.5 ~ 1.0 mg/L and 0.27 mg/L, respectively. As for COD and BOD effluent concentrations, COD was 3.0 mg/L and BOD was 1.0 mg/L. Additionally, nitrogen removal rates were high at low influent DO concentration. In conclusion, a new process, biofilter packed with granular sulfur is expected to treat high-rate nitrogen wastewater and expected to be utilized as an alternative of technological innovation for the nitrogen treatment.

활성오니를 이용한 인 및 질소의 생물학적 제거 (Biological Phosphorus and Nitrogen Removal in Anaerobic-Aerobic Activated Sludge Process)

  • 최승태;박미연;장동석
    • 한국수산과학회지
    • /
    • 제27권6호
    • /
    • pp.690-695
    • /
    • 1994
  • 혐기-호기 체계의 활성오니를 이용하여 폐수로부터 인과 질소를 동시에 제거하는 연구를 행하였다. 혐기적인 조건에서 nitrate 혹은 nitrite의 농도가 거의 0일 때, 제거된 glucose의 양은 orthophosphate의 방출과 직선적인 관계를 나타내었으며, 유입수에서 인과 glucose의 비율이 0.04 이하일 때, 폐수 중의 인은 호기적인 단계에서 거의 제거되었다. 이는 혐기적 단계에서 받은 stress로 인해 호기적 단계에서 받은 stress로 인해 호기적 단계에서 훨씬 많은 양의 인을 흡수한 것으로 생각된다. 혐기적 단계에서의 인의 방출양과 호기적 단계에서의 인의 흡수양은 $NO_x-N$의 농도와는 비례적인 관계가 아니었으며, 더우기, glucose에 대한 $NO_2-N$의 비가 0.37보다 낮을 때, 유입수 중의 무기질소는 완전히 제거되었다.

  • PDF

컴퓨터 시뮬레이션을 이용한 신 생물학적 고도처리 (병렬 고도처리) 공법 개발 (Developing a New BNR (Parallel BNR) Process by Computer Simulation)

  • 이병희;이용운
    • 상하수도학회지
    • /
    • 제16권6호
    • /
    • pp.670-678
    • /
    • 2002
  • Since Korean government imposed a stricter regulation on effluent T-N and T-P concentrations from wastewater treatment plant, a new process has to be developed to meet these rules and this process should remove T-N and T-P, economically, from weak wastewater that is typical for Korea's combined sewer system sewage. In this study, a computer simulator, BioWin from EnviroSim, Inc. was used. Three processes - A2/O, Modified Johannesburg, UCT- had been simulated under same operational conditions and a new process - Parallel BNR Process - had been developed based on these simulation results. The Parallel BNR process consists of two rows of reactors: One row has anaerobic and aerobic reactors in series, and the other row has RAS anoxic1 and RAS anoxic2 reactors in series. In order to ensure anaerobic state in anaerobic tank, a part of influent is fed to RAS anoxic1 tank in second row. This process had been simulated under same conditions of other three processes and the simulation results were compared. The results showed that three existing processes could not perform biological phosphorus removal when the average influent was fed at any operation temperatures. However, the Parallel BNR process was found that biological phosphorus removal could be performed when both design and average influent were fed at any operation temperatures. This process showed the T-N concentration in effluent had a maximum value of 15mg/L when design influent was fed at $13^{\circ}C$ and a minimum value of 14mg/L when average influent was fed at $20^{\circ}C$. Also, T-P concentrations had a maximum value of 1.3mg/L when average influent was fed at $20^{\circ}C$ and a minimum value of 1.1mg/L when design influent was fed at $13^{\circ}C$. Based on these results, we found that this process can remove nitrogen and phosphorus biologically under any operational conditions.