• Title/Summary/Keyword: Inflow noise

Search Result 67, Processing Time 0.023 seconds

A Case Study on the Characteristics of the Road Traffic Noise in Plant Communities (학교 정온시설 앞 식물군락 조성지역에서 도로교통소음 특성에 대한 사례연구)

  • Cho, Il-Hyoung;Lee, Nae-Hyun;Cho, Jung-Sang;Ko, Jung-Yong;SunWoo, Young;Park, Young-Min
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.12
    • /
    • pp.1293-1303
    • /
    • 2006
  • This paper represents a comparison the difference between existence and nonexistence of soundproof trees for road traffic noise. Also we suggested that the simple equation has been derived using a single regression analysis for predicting levels of $Leq_{th}$ at a given distance from a road in terms of the flow rate, the mean speed of the traffic, and the percentage of the type vehicles in the existence and nonexistence of soundproof trees. We classified a vehicle into four and analyzed contribution rate to traffic volume. As a result, the order showed as followed: light vehicle>medium vehicle>heavy vehicle>motorcycle. However, the results of analyzing contribution rate with between traffic volume and traffic noise by the each type showed as followed; Motorcycle>Light vehicle>Medium vehicle>Heavy vehicle. This study showed that the most a lof of traffic volumes of the three vehicles(light vehicle, medium vehicle and motorcycle) and heavy vehicle were existed in 67 km/h and 61 km/h of car speed, respectively. The total traffic noise to the mean car speed decreased because of the inflow a lot of traffic volumes between 2016 and 2388 in the range of 67 km/h of light vehicle speed, in traffic composition of 4.75% heavy vehicles, and 1.11% motorcycle. the final result for this study showed that statistical paired t-test for between existence and nonexistence of soundproof trees was significant(p<0.05) and the difference between daytime and night in the location of the nonexistence of plant communities with the independent sample T-test was significant(p<0.05). However, the independent sample T-test for analyzing the variance of traffic noise between daytime and night was not significant(p>0.05).

Development of a new free wake model using finite vortex element for a horizontal axis wind turbine

  • Shin, Hyungki;Park, Jiwoong;Lee, Soogab
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.18 no.1
    • /
    • pp.17-27
    • /
    • 2017
  • The treatment of rotor wake has been a critical issue in the field of the rotor aerodynamics. This paper presents a new free wake model for the unsteady analysis for a wind turbine. A blade-wake-tower interaction is major source of unsteady aerodynamic loading and noise on the wind turbine. However, this interaction can not be considered in conventional free wake model. Thus, the free wake model named Finite Vortex Element (FVE hereafter) was devised in order to consider the interaction effects. In this new free wake model, the wake-tower interaction was described by dividing one vortex filament into two vortex filaments, when the vortex filament collided with a tower. Each divided vortex filaments were remodeled to make vortex ring and horseshoe vortex to satisfy Kelvin's circulation theorem and Helmholtz's vortex theorem. This model was then used to predict aerodynamic load and wake geometry for the horizontal axis wind turbine. The results of the FVE model were compared with those of the conventional free wake model and the experimental results of SNU wind tunnel test and NREL wind tunnel test under various inflow velocity and yaw condition. The result of the FVE model showed better correlation with experimental data. It was certain that the tower interaction has a strong effect on the unsteady aerodynamic load of blades. Thus, the tower interaction needs to be taken into account for the unsteady load prediction. As a result, this research shows a potential of the FVE for an efficient and versatile numerical tool for unsteady loading analysis of a wind turbine.

Application of risk analysis and assessment considering tunnel stability and environmental effects in tunnel design (터널 안정성 및 환경성을 고려한 위험도 평가기법의 적용)

  • Kim, Young-Geun;Kim, Do-Hyung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.10 no.1
    • /
    • pp.1-15
    • /
    • 2008
  • Recently, because of the various factors by uncertainty of underground, the risks in tunnelling have been occurred increasingly. Therefore, it is very important to estimate and control the risks considering geotechnical conditions for tunnel stability and environmental problems by tunnel construction. In this study, the risk analysis for tunnel stability was carried out by classifying the risk factors such as ground support capacity, ground settlement, the inflow of groundwater into the tunnel and the damage by the earthquake. Also, the risk assessment for the environmental problems was performed by calculating the vibration and noise by blasting and the drawdown of the groundwater level caused by tunnel construction. Each risk factor was evaluated quantitatively based on the probabilistic and statistic technique, then it was analyzed the distribution characteristic along overall tunnel site. Finally, it was evaluated that how much each risk factor influences on the construction cost with a period for tunnel construction, so it is possible to perform reasonable tunnel design which was capable of minimizing the risks in the tunnel construction.

  • PDF

Study on Dangerous Factors and Damage Pattern Analysis of Leaking Water from Water Purifiers (누수가 발생한 정수기의 위험요소 발굴 및 소손패턴 해석에 관한 연구)

  • Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.3
    • /
    • pp.57-62
    • /
    • 2012
  • The purpose of this paper is to find dangerous factors of a water purifier when water leaks due to inappropriate use and analyze the patterns of damaged parts in order to provide data for the examination of the cause of the problem. If the water purifier is inspected and managed by a non-specialist, when the FLC(Float Level Controller) at the top is inclined, water leakage may occur to the water purifier. The leaked water flows onto the cables and hoses and enters the thermostat terminal, heater, PCB, power supply connection connector, etc., becoming a dangerous factor that may cause a system failure, fire, etc. Due to the water that entered the input terminal, low noise and white smoke were generated at first. However, the flame gradually propagated due to the continuous inflow of moisture. It was found that when moisture reached the PCB, a carbonized conductive path was formed at the varistor terminal, input terminal, semiconductor device terminal, etc., and the flame became larger, which might result in a fire. From the metal microscope analysis of a damaged condenser terminal, it was found that the amorphous structure unique to copper cable disappeared, and voids, boundary surface and disorderly fine particles occurred. Also, in the case of the connector into which moisture penetrated, fusion and deformation occurred at the cable connection clips. The result of analysis of the power supply cable connector using a thermal image camera showed that most of the heat was generated from the cable connection clips and the temperature at the connection center was normal.

Future Inflow Simulation Considering Climate Change in Chungju Dam Basin (기후변화를 고려한 충주댐 유역의 미래 유입량 모의)

  • Park, Ji-Yeon;Shin, Ju-Young;Kim, Tae-Rim;Heo, Jun-Haeng
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.125-125
    • /
    • 2012
  • 최근 심화되고 있는 강우의 시간적 지역적 불균형이 기후변화와 높은 연관성이 있다는 연구결과가 발표되고 있다. 강우에 직접적인 영향을 받는 수자원분야에서는 강우의 변동성을 예측한 결과를 바탕으로 기후변화 영향에 대한 연구가 활발히 진행 하고 있다. 우리나라의 연중 강수량의 대부분이 홍수기에 집중되어 수자원의 총량의 27%만 사용하고 있다. 전체 수자원이용량 중 절반 이상을 댐을 통해 이용하고 있기 때문에 댐 운영방법에 지속적인 연구가 필요하다. 기후변화영향으로 댐 유입량에 대한 불확실성이 커지므로 장기적인 수자원을 관리를 위하여 효율적인 댐 운영을 하기 위한 해결책이 필요하다. 물리적 강우-유출 모형으로 기후변화 영향을 받는 장기간 모의를 하게 되면 입력 자료와 매개변수, 모형구조의 불확실성 갖게 된다. 그에 반해 데이터를 통해 모형의 매개변수 값을 추정하여, 향후의 의사결정에 활용할 수 있는 모형을 구축하는 추계학적 모형과 인공신경망모형은, 물리적인 강우-유출 모형과 비교하여 모의에 드는 시간이 적고 모형 불확실성 파악이 가능하며, 장기간 모의 시 불확실성을 줄이는 효율적인 대안이 될 수 있다. 일반적인 추계학적 모형은 과거의 유입량 자료만 사용하지만 본 연구에서는 기후변화 시나리오 강우량의 영향을 함께 고려한 Transfer Function Noise(TFN)모형을 통하여 장기간 모의를 하였다. 본 연구의 대상 댐으로는 한강유역 중 댐 상류유역면적이 제일 넓은 충주댐으로 선정하였다. 과거의 유입량과 강우량 자료를 사용하여 통계적 방법을 통하여 TFN모형을 구축하고, TFN과 같은 변수를 사용하여 인공신경망모형을 구축하였다. 5개의 시나리오별로 어떠한 차이를 갖는지를 비교하였고, TFN모형과 인공신경망에 따라서 어떠한 양상을 갖는지 비교하였다.

  • PDF

Analysis of Characteristics of NPS Runoff and Pollution Contribution Rate in Songya-stream Watershed (송야천 유역의 비점오염물질 유출 특성 및 오염기여율 분석)

  • Kang Taeseong;Yu Nayeong;Shin Minhwan;Lim Kyoungjae;Park Minji;Park Baekyung;Kim Jonggun
    • Journal of Korean Society on Water Environment
    • /
    • v.39 no.4
    • /
    • pp.316-328
    • /
    • 2023
  • In this study, the characteristics of nonpoint pollutant outflow and contribution rate of pollution in Songya-stream mainstream and tributaries were analyzed. Further, water pollution management and improvement measures for pollution-oriented rivers were proposed. An on-site investigation was conducted to determine the inflow of major pollutants into the basin, and it was found that pollutants generated from agricultural land and livestock facilities flowed into the river, resulting in a high concentration of turbid water. Based on the analysis results of the pollution load data calculated through actual measurement monitoring (flow and water quality) and the occurrence and emission load data calculated using the national pollution source survey data, the S3 and S6 were selected as the concerned pollution tributaries in the Songya-stream basin. Results of cluster analysis using Pearson correlation coefficient evaluation and Density based spatial clustering of applications with noise (DBSCAN) technique showed that the S3 and S6 were most consistent with the C2 cluster (a cluster of Songya-stream mainstream owned area) corresponding to the mainstream of Songya-stream. The analysis results of the major pollutants in the concerned pollution tributaries showed that livestock and land pollutants were the major pollutants. Consequently, optimal management techniques such as fertilizer management, water gate management in paddy, vegetated filter strip and livestock manure public treatment were proposed to reduce livestock and land pollutants.

Development of High-performance Microwave Water Surface Current Meter for General Use to Extend the Applicable Velocity Range of Microwave Water Surface Current Meter on River Discharge Measurements (전자파표면유속계를 이용한 하천유량측정의 적용범위 확장을 위한 고성능 범용 전자파표면유속계의 개발)

  • Kim, Youngsung;Won, Nam-Il;Noh, Joonwoo;Park, Won-Cheol
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.8
    • /
    • pp.613-623
    • /
    • 2015
  • To overcome the difficulties of discharge measurements during flood season, MWSCM(micowave water surface current meter) which measures river surface velocities without contacting water has been applied in field work since its development. The existing version of MWSCM is for floods so that its applicability is low due to the short periods of floods. Therefore the renovative redesign of MWSCM to increase the applicability was conducted so that it can be applied to the discharge measurements during normal flows as well as flood ones by extending the measurable range of velocity. A newly developed high-performance MWSCM for general use can measure the velocity range of 0.03-20.0 m/s from flood flows to normal flows, whereas MWSCM for floods can measure the velocity range of 0.5-10.0 m/s. The improvement of antenna isolation between transmitter and receiver to block the inflow of transmitted singals to receiver and the improvement of phase noise of oscillator are necessary for detecting low velocity with MWSCM technology. Separate type antenna of transmitting and receiving signals is developed for isolation enhancement and phase locked loop synthesizer as an oscillator is applied to high-performance MWSCM for general use. Microwave frequency of 24 GHz is applied to the new MWSCM rather than 10 GHz to make the new MWSCM small and light for convenient use of it at fields. Improvement requests on MWSCM for floods-stable velocity measurement, self test, low power consumtion, and waterproof and dampproof-from the users of it has been reflected on the development of the new version of MWSCM.