• Title/Summary/Keyword: Infiltration performance

Search Result 169, Processing Time 0.023 seconds

침투도랑 인접도로 하부구조의 함수비 측정 및 공용성 분석 (Analysis of Performance and Measurement of Water Contents for Road Substructures with an Infiltration Trench)

  • 공석준;정종석;연규민;김인태
    • 한국도로학회논문집
    • /
    • 제19권1호
    • /
    • pp.29-36
    • /
    • 2017
  • PURPOSES : This study mechanically analyzed the performance of road substructures with focus on infiltration trenches of pavement substructures. METHODS : Water contents and response times for precipitation of pavement substructures were investigated via sensors buried near the infiltration trench to measure water contents. RESULTS : The results of the water contents of pavement systems constructed with an infiltration trench yield levels that were slightly increased by approximately 2% compared to those measured from general pavement systems. This water content difference of 2% resulted in a decrease in service life of less than two years. CONCLUSIONS : Service life reduction due to an infiltration trench is minimal, particularly when the trench is installed with proper caution.

Hematuria Screening Test for Urinary Bladder Mucosal Infiltration in Cervical Cancer

  • Chuttiangtum, Ayuth;Udomthavornsuk, Banchong;Chumworathayi, Bandit
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권10호
    • /
    • pp.4931-4933
    • /
    • 2012
  • Objective: To determine the diagnostic performance of hematuria as a screening test for urinary bladder infiltration in cervical cancer patients with a prospective study design. Materials and Methods: Newly diagnosed cervical cancer patients at Srinagarind hospital from 14 June 2011 to 30 April 2012 were enrolled in this study. We collected midstream urine samples for urinalysis from every patient before routine cystoscopic exam for clinical staging. The presence of 3 or more red blood cells (RBCs) per high power field was defined as positive for hematuria. A two-by-two table was used to determine the diagnostic performance of hematuria to detect urinary bladder mucosal infiltration using cystoscopy and biopsy as the gold standard. Result: A total of 130 were patients included, 54 of which (41.5%) had hematuria. Of these, four patients (3.08%) had pathological report from cystoscopic biopsy confirmed metastatic squamous cell carcinoma. The sensitivity, specificity, PPV, NPV, and accuracy of hematuria as a screening test to detect urinary bladder mucosal infiltration of cervical cancer were 100%, 60.3%, 7.4%, 100%, and 61.5%, respectively. There was no single case of urinary bladder mucosal infiltration in patients initially staged less than stage III. Conclusions: Hematuria can be used as a screening test to detect urinary bladder mucosal infiltration of cervical cancer. This can reduce the number of cervical cancer patients who really need to undergo cystoscopy as a staging procedure to less than half and to less than 20% if stage III or more were included without missing a single case of urinary bladder mucosal infiltration.

기존 단독주택의 침기량 산정법에 관한 연구 (A Study on the Calculation Method of Infiltration for Detached Houses)

  • 김길태;유정현;황하진;김경식
    • 설비공학논문집
    • /
    • 제25권9호
    • /
    • pp.493-498
    • /
    • 2013
  • The purpose of this study is to find the infiltration of detached houses, for energy consumption analyses. The pressurization and depressurization method is used to determine infiltration. Blower door tests are expressed in terms of ACH 50, which stands for the hourly air change rate at 50 Pa of fan pressure. The ACH 50 of existing Detached Houses ranges from 5 to 50. Air infiltration is related to construction year and accuracy, maintenance conditions, and so on. When estimating the infiltration of random detached houses, the year used can be the base value of the infiltration rate from 0.25 to 2.0 times/h. The maintenance conditions, construction accuracy and repair affect the air infiltration 0 to 0.5 times/h, 0 to 0.3 times/h, 0 to 1 times/h, respectively.

C/SiC 복합재료의 내열성능 평가 (Performance Evaluation of C/SiC Composites)

  • 김연철
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제28회 춘계학술대회논문집
    • /
    • pp.185-188
    • /
    • 2007
  • 액체 및 고체추진기관의 내열부품으로 사용하기 위하여 Liquid Silicon Infiltration(액체 실리콘 함침) 공정이 적용된 C/SiC 복합재료를 개발하였다. 탄소섬유 및 탄소직물을 사용하여 필리멘트 와인딩, 테이프 롤링 및 인벌루트 적층 공법이 사용된 다양한 탄소 프리폼이 제작되었다. 내열 부품으로써의 열구조 성능을 극대화시키기 위하여 SiC 함유량, 열처리 조건, 수지 및 기상 함침 조건을 변화시키면서 시편을 제작하고 평가하였다. C/SiC 복합재료를 액체 및 고체추진기관의 내열부품으로 사용하기 위하여 연소시험을 수행하였으며 내열 성능 해석을 위한 수학적 삭마 모델이 개발되었다.

  • PDF

냉동냉장창고 침기방지장치의 성능평가에 관한 연구 (A Study on the Performance Evaluation of Infiltration Prevent Devices in refrigerated Warehouse)

  • 곽현철;석호태;송승영;황혜주;안홍섭
    • 설비공학논문집
    • /
    • 제14권1호
    • /
    • pp.55-62
    • /
    • 2002
  • In this paper, several types of infiltration prevention devices that are currently in use have been studied through experimental investigation. Firstly, the types of infiltration prevention devices were defined through investigating actual conditions of refrigerated warehouse in operates. Based on this investigation results, measured change of temperature and figured out air change rates of the type of infiltration prevention devices by using scale down model. After that, found the amount of air change rate in order to estimate the load of air change easily in facility plan.

하수관거정비 임대형민자사업에 있어 침입수 성과지표의 개선에 관한 연구 - 제주특별자치도를 중심으로 - (Improvement of Infiltration Performance Measurement in BTL (Build-Transfer-Lease) Sewer Rehabilitation Projects - Focusing on Jeju Special Self-Governing Province -)

  • 고영남;이동욱
    • 대한토목학회논문집
    • /
    • 제36권6호
    • /
    • pp.1133-1143
    • /
    • 2016
  • 본 연구는 하수관거정비 임대형민자사업에 있어 사업효과 분석지표의 개선에 대한 연구이다. 하수관거정비 임대형민자사업의 평가지표 중 침입수에 대한 평가지표는 단일평가항목으로 17.5점의 높은 점수가 부여되고 있다. 침입수에 대한 평가지표는 침입수의 발생량에 초점을 맞추어 평가되고 있으며, 현재 '야간 생활하수 평가법'에 따라 계산되고 있다. 그러나, 본 평가지표가 제주지역의 지질적 특성을 반영하지 못하고 있다는 것이 운영단계에서 문제점으로 대두되고 있다. 따라서 본 연구에서는 제주지역을 중심으로 평가지표에 따른 계산 결과와 실제 침입수의 발생량을 비교 분석하고자 하였다. 이를 위해서 제주도내 5개 지역에 대하여 '야간 생활하수 평가법'에 따른 침입수 발생량을 분석하였다. 또한 실제적으로 침입수가 발생하는 조건에 대하여 전수조사를 실시하였다. 분석 결과, 지하수위가 하수관거보다 밑에 분포되고 있으며, 하수관거의 기능에 대한 검증 결과 하수관거의 결함 등에 의한 침입수 발생은 없는 것으로 분석되었다. 따라서 현재 평가지표로 활용되고 있는 '야간 생활하수 평가법'은 제주지역에 적용하기에 적합하지 않다는 결론에 도달하게 되었으며, 제주지역만의 침입수 관련 기준 마련이 필요할 것으로 사료된다.

침투트렌치 시설의 유출저감 효과 분석 (Analysis of Infiltration Trench Facility for Runoff Reduction Effect)

  • 연종상;장영수;신현석;김응석
    • 한국산학기술학회논문지
    • /
    • 제15권9호
    • /
    • pp.5813-5819
    • /
    • 2014
  • 도시화로 인한 도시유역의 불투수면적 증가에 따른 우수유출수 증가를 저감하기 위해 저영향개발의 계획 및 적용이 활발하게 진행되고 있다. 본 연구에서는 LID 요소기술 중 침투트렌치의 국내 적용성 및 성능검증을 위해 침투트렌치 실험조건을 바탕으로 SWMM을 구축하여 유출량 및 비점오염원 저감효과를 분석하였다. SWMM의 침투트렌치 적용면적은 전체 유역면적의 5~15%의 면적에 적용하며 모의를 수행하였다. SWMM 모의결과 첨두유출량은 45.7~61.9%, 총유출량은 47.2~62.3%, BOD 부하량은 52.3~55.3%의 저감효율로 분석되었다. 실험결과와 비교하면 유출량의 경우 12~24% 크며, BOD 부하량의 경우 37~38% 작게 산정되었다. 추후 침투트렌치의 적용성 및 성능검증에 도움을 줄 수 있을 것으로 판단된다.

Infiltration법을 이용한 LaySr1-yFexTi1-xO3계 나노복합 연료극 제조 (Fabrication of LaySr1-yFexTi1-xO3-based Nanocomposite Solid Oxide Fuel Cell Anodes by Infiltration)

  • 윤종설;최영주;황해진
    • 한국세라믹학회지
    • /
    • 제51권3호
    • /
    • pp.224-230
    • /
    • 2014
  • Nano-sized gadolinium-doped ceria (GDC)/nickel particle-dispersed $La_ySr_{1-y}Ti_{1-x}Fe_xO_3$ (LSFTO)-based composite solid oxide fuel cell anodes were fabricated by an infiltration method and the effects of the GDC/Ni nanoparticles on the anode polarization resistance and cell performance were investigated in terms of the infiltration time and nickel content. The anodic polarization resistance of the LSFTO anode was significantly enhanced by GDC and/or Ni infiltration and it decreased with increasing infiltration time and Ni content, respectively. It is believed that the observed phenomena are associated with enhancement of the ionic conductivity and catalytic activity in the nanocomposite anodes by the addition of GDC and Ni. Power densities of cells with the LSFTO and LSFTO-GDC/Ni nanocomposite anodes were 150 and $300mW/cm^2$ at $800^{\circ}C$, respectively.

공동주택의 기밀성능 평가 및 에너지 절감효과 분석 (An Evaluation of Airtightness Performance and Analysis of Energy Savings Potential in Apartment Housing)

  • 이승복
    • 태양에너지
    • /
    • 제15권3호
    • /
    • pp.119-125
    • /
    • 1995
  • 지금까지 우리는 건물분야에서의 합리적인 에너지 사용을 위하여 건물외피의 단열성능을 향상시킴으로써 열손실을 줄이려는 데에 주력하여 왔으며, 침기로 인한 열손실을 줄이려는 노력은 상대적으로 미흡하였다. 그러나, 침기로 인한 난방에너지의 소비가 상당량에 이르는 것으로 조사됨으로써 재실형태에 따라 최소환기기준을 만족시키면서 침기에 의한 불필요한 에너지의 손실을 줄이려는 노력이 매우 유효한 것으로 평가되고 있다. 실제로 침기에 의한 불필요한 에너지의 낭비가 얼마나 되는가를 평가하기 위해서는, 건물에서의 침기율을 정확하게 측정할 수 있는 방법이 전제되어야 한다. 본 연구에서는 감압/가압법의 일종인 Blower Door System을 사용하여 공동주택에서의 기밀성능을 측정, 평가함은 물론 측정결과를 토대로 합리적인 수준까지 기밀화할 경우 난방에너지의 절약가능성에 대하여 추정하였다.

  • PDF

화단형 침투시설의 단위설계침투량 산정 및 효과분석 (Estimation of Appropriate Infiltration Rate and the Effects of the Flowerbed Type Infiltration System)

  • 한영해;이태구
    • 한국조경학회지
    • /
    • 제40권5호
    • /
    • pp.140-147
    • /
    • 2012
  • 본 연구에서는 우수 유출량을 일정수준 이하로 제어할 수 있는 화단형 침투시설을 개발하여 이의 적정 설계침투량을 산정하고 적용효과를 분석하였다. 침투시설의 설계침투량을 산정하고 성능을 분석하는 것은 지구단위계획과 같은 공간계획에 구체적으로 빗물침투시설을 계획할 경우에 적용 후 효과를 예측하는데 있어 반드시 검토되어야 할 사항이다. 이에 본 연구에서는 한국건설기술연구원 실험동 옆 주차장을 대상으로 본 시설의 단위설계침투량에 변화를 주어 물수지 분석 프로그램을 이용, 유출량 감소효과를 분석하였다. 침투시설의 설계침투량을 $0.1{\sim}3m^3/m^2.day$로 각각 변화를 주어 유출율 변화를 분석한 결과, $1.0m^3/m^2.day$에서 유출량 80%를 침투시키는 것으로 분석되었으며, 이때의 단위설계침투량이 0.0416($m^3/m^2.hr$)이었다. 또한 개발한 시스템을 현장침투실험한 결과, 단위설계침투량이 약 $0.045m^3/m^2.hr$으로 나타났다. 이 값은 시뮬레이션한 단위설계침투량과 유사한 것으로 분석되었다. 본 연구결과를 토대로 경제적인 규모와 환경적 효과를 최대한 고려한 침투량 산정이 가능하였으며, 또한 도시에서의 녹색인프라로서 빗물침투시설을 공간계획에 적용할 때 고려할 수 있는 근거를 마련했다는 데 의의를 갖는다.