• 제목/요약/키워드: Infiltration parameters

검색결과 207건 처리시간 0.024초

Horton 침투 모형의 매개변수 결정 사례 (Case Study on the Determination of the Parameters in the Horton's Infiltration Model)

  • 유주환;윤여진
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2009년도 학술발표회 초록집
    • /
    • pp.107-111
    • /
    • 2009
  • The parameters in the Horton's model which has well known as typical infiltration model were determined by the use of the optimization technique. It was assumed the initial infiltration capacity in this model was related to the antecedent precipitation per 10 days with linear combination. And both the parameters of the ultimate infiltration capacity and the decay factor were determined uniquely on a basin. Thus the optimal model's parameters representative to a basin were obtained and the Horton's infiltration equations by rainstorm events were determined. The data of ten rainstorm events for this study were observed at the Jeonjeokbigyo station located at the Selmacheon experimental basin that was $8.5\;km^2$ wide in the Imjin river.

  • PDF

유역을 대표하는 Horton 침투 모형내 매개변수의 최적 결정 (Optimal Determination of the Parameters Representative of a Basin in the Horton's Infiltration Model)

  • 유주환
    • 한국수자원학회논문집
    • /
    • 제39권11호
    • /
    • pp.977-984
    • /
    • 2006
  • 최적화 방법을 이용하여 대표적 침투 모형으로 잘 알려진 Horton모형의 최적 매개변수를 결정하였다. Horton침투 모형내 초기 침투능은 10일 단위 선행 강수량과 선형 조합의 관계를 갖는다고 가정하였다. 그리고 종기 침투능과 감쇄지수 값은 유역내 하나의 대표치로 결정하였다. 이렇게 하여 유역을 대표하는 모형의 매개변수 최적치를 얻었고 호우 사상별로 Horton의 침투식을 결정하였다. 본 연구에서 적용한 10개의 호우 자료는 임진강 내에 있고 배수 면적이 $8.5km^2$되는 설마천 시험 유역내 전적비교 지점에서 관측된 것이다.

공동주택 침기의 불확실성 분석 (Infiltration in Residential Buildings under Uncertainty)

  • 현세훈;박철수;문현준
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.369-374
    • /
    • 2006
  • Quantification of infiltration rate is an important issue in HVAC system design. The infiltration in buildings depends on many uncertain parameters that vary with significant magnitude and hence, the results from standard deterministic simulation approach can be unreliable. The authors utilize uncertainty analysis In predicting the airflow rates. The paper presents relevant uncertain parameters such as meteorological data, building parameters (leakage areas of windows, doors, etc.), etc. Uncertainties of the aforementioned parameters are quantified based on available data from literature. Then, the Latin Hypercube Sampling (LHS) method was used for the uncertainty propagation. The LHS is one of the Monte Carlo simulation techniques that is suited for our needs. The CONTAMW was chosen to simulate infiltration phenomena in a residential apartment that is typical of residential buildings in Korea. It will be shown that the uncertainty propagating through this process is not negligible and may significantly influence the prediction of the airflow rates.

  • PDF

Impedance Parameter Variations at Intravenous (IV) Infiltration Using Bioelectrical Impedance: A Pilot Study

  • Kim, Jaehyung;Lee, Mansup;Baik, Seungwan;Kim, Gunho;Hwang, Youngjun;Jeon, Gyerok
    • 한국멀티미디어학회논문지
    • /
    • 제20권10호
    • /
    • pp.1678-1688
    • /
    • 2017
  • Infiltration is one of detrimental problems occurring in nursing or medical settings. Early detection of infiltration is essential to minimize the risk of injury from infiltration. To perform a preliminary study on the point of care and automated infiltration detection system, bioelectrical impedance was investigated using bioelectrical impedance analyzer. We would like to report experimental results that allow impedance parameters to effectively distinguish infiltration. Electrodes were attached to both sides of the transparent dressing on the fusion site where IV solution was being infused. Then, impedance parameters before and after infiltration were measured as a function of time and frequency. The experimental results are as follows. After infiltration was intentionally induced by puncturing the vein wall with a needle, the resistance gradually decreased with time. That is, when an alternating current having a frequency of 20 kHz was applied to the electrodes, the resistance gradually decreased with time, reflecting the accumulation of IV solution in the extracellular fluid since the current could not pass through the cell membrane. Impedance parameters and equivalent circuit model for human cell were used to examine the mechanism of current flow before and after infiltration, which could be used for early detection of infiltration.

Shear strength characteristics of a compacted soil under infiltration conditions

  • Rahardjo, H.;Meilani, I.;Leong, E.C.;Rezaur, R.B.
    • Geomechanics and Engineering
    • /
    • 제1권1호
    • /
    • pp.35-52
    • /
    • 2009
  • A significantly thick zone of steep slopes is commonly encountered above groundwater table and the soils within this zone are unsaturated with negative pore-water pressures (i.e., matric suction). Matric suction contributes significantly to the shear strength of soil and to the factor of safety of unsaturated slopes. However, infiltration during rainfall increases the pore-water pressure in soil resulting in a decrease in the matric suction and the shear strength of the soil. As a result, rainfall infiltration may eventually trigger a slope failure. Therefore, understanding of shear strength characteristics of saturated and unsaturated soils under shearing-infiltration (SI) conditions have direct implications in assessment of slope stability under rainfall conditions. This paper presents results from a series of consolidated drained (CD) and shearing-infiltration (SI) tests. Results show that the failure envelope obtained from the shearing-infiltration tests is independent of the infiltration rate. Failure envelopes obtained from CD and SI tests appear to be similar. For practical purposes the shear strength parameters from the CD tests can be used in stability analyses of slopes under rainfall conditions. The SI tests might be performed to obtain more conservative shear strength parameters and to study the pore-water pressure changes during infiltration.

Early Detection of Infiltration Induced in the Veins of Pig's Ear and Human's Forearm By Using Bioimpedance: Pilot Study

  • Kim, Jaehyung;Hwang, Youngjun;Kim, Gunho;Jeong, Ihn Sook;Jeon, Gyerok
    • 한국멀티미디어학회논문지
    • /
    • 제21권1호
    • /
    • pp.34-44
    • /
    • 2018
  • An early detection of intravenous (IV) infiltration is essential to minimize the injuries during infusion therapy, which is one of the most important tasks for nurses in nursing settings. We report that bioelectrical impedance analysis is useful in the early detection of infiltration at puncture sites. When infiltration was intentionally induced in the vein of a pig's posterior ear, impedance parameters (R, $X_C$, $C_m$) showed significant differences before and after infiltration. In particular, the relative resistance ($R/R_{BI}$) decreased significantly at infiltration and then slowly decreased. This indicates that the vein in pig's ear is thin and the amount of surrounding subcutaneous tissue, and hence the infiltrated solution accumulates slowly after infiltration. However, when infiltration was induced in the vein of human's forearm, the relative resistance at 20 kHz decreased gradually over time. In the $R-X_C$ graph, the positions in the case of infiltration induced in the pig' ear shifted rapidly before and after infiltration, whereas the positions in the case of infiltration induced in the human's forearm moved gradually during infiltration. Our findings suggest that the impedance parameters (R, $R/R_{BI}$, $X_C$, R vs. $X_C$, and $C_m$) are effective indicators to detect the infiltration early in a non-invasive and quantitative manners.

Early Detection of Intravenous Infiltration Using Multi-frequency Bioelectrical Impedance Parameters: Pilot Study

  • Kim, Jae-Hyung;Shin, Beum-Joo;Baik, Seung-Wan;Jeon, Gye-Rok
    • 센서학회지
    • /
    • 제26권1호
    • /
    • pp.15-23
    • /
    • 2017
  • In this study, bioelectrical impedance analysis, which has been used to assess an alteration in intracellular fluid (ICF) of the body, was applied to detect intravenous infiltration. The experimental results are described as follows. Firstly, when infiltration occurred, the resistance gradually decreased with time and frequency i.e., the resistance decreased with increasing time, proportional to the amount of infiltrated intravenous (IV) solution. At each frequency, the resistance gradually decreased with time, indicating the IV solution (also blood) accumulated in the extracellular fluid (ECF) (including interstitial fluid). Secondly, the resistance ratio started to increase at infiltration, showing the highest value after 1.4 min of infiltration, and gradually decreased thereafter. Thirdly, the impedance ($Z_C$) of cell membrane decreased significantly (especially at 50 kHz) during infiltration and gradually decreased thereafter. Fourthly, Cole-Cole plot indicated that the positions of (R, $X_C$) shifted toward left owing to infiltration, reflecting the IV solution accumulated in the ECF. The resistance ($R_0$) at zero frequency decreased continuously over time, indicating that it is a vital impedance parameter capable of detecting early infiltration during IV infusion. Finally, the mechanism of the current flowing through the ECF, cell membrane, and ICF in the subcutaneous tissues was analyzed as a function of time before and after infiltration, using an equivalent circuit model of the human cell. In conclusion, it was confirmed that the infiltration could be detected early using these impedance parameters during the infusion of IV solution.

Effect of Powder Size on Infiltration Height in Producing MgO Reinforced Al Matrix Composite by Vacuum Infiltration Method

  • Calin, Recep;Citak, Ramazan
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.1271-1272
    • /
    • 2006
  • The vacuum infiltration method is one of the composite producing methods. There are several parameters in composite production by vacuum infiltration. One of them is particle size of reinforcement in particulate reinforced composites. In this study, MgO powder and Al were used as reinforcement and matrix respectively. MgO powders with different size and amount to give same height were filled in quartz tubes and liquid metal was vacuum infiltrated into the MgO powder under same vacuum condition and for same time. Infiltration height was measured and microstructure and fracture behavior of composite were investigated. It has been found that infiltration height and fracture strength were increased with particulate reinforcement sizes. It has also been determined that molten metal temperature facilitates infiltration.

  • PDF

화강풍화토의 불포화 침투특성에 관한 연구 (Infiltration Characteristics for Unsaturated Residual Soil)

  • 김영욱;김도형;성상규;이인모
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.147-152
    • /
    • 2001
  • This study investigated one-dimensional vertical infiltration to an unsaturated residual soil by numerical solutions, FDM. In order to estimate the parameters needed for numerical analysis, tire soil-water characteristic curve(SWCC) of Shinnae-dong soil, one of the most typical residual soils in Korea, were experimentally obtained. Then, the statistical analysis for obtaining the SWCC was performed. The numerical solution to the linearized governing equation for unsaturated groundwater flow provides the infiltration characteristics for the unsaturated residual soil represented by transient pressure profiles and water contents profiles.

  • PDF

가압함침공정 중 기공 형성에 대한 제조 변수의 영향 (The Influence of Fabrication Parameters on the Porosity Formation during Squeeze Infiltration Process)

  • 서영호;이형국
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2001년도 춘계학술발표대회 논문집
    • /
    • pp.184-188
    • /
    • 2001
  • The squeeze infiltration process is potentially of considerable industrial importance. The performance enhancements resulting from incorporation of short alumina fiber into aluminum are well documented. These are particularly significant for certain automobile components. But the solidification process gets complicated with manufacturing parameters and factors for porosity formation do not fully understand yet. In this study porosity defects were observed under several infiltrating conditions ; a kind of matrix, an initial temperature of melt, and a volume fraction of reinforcement. The desimetry and the microscopic image analysis were done to measure the amount of porosity. A correlation between manufacturing parameters and defects was investigated through these.

  • PDF