• 제목/요약/키워드: Infiltration analysis

검색결과 760건 처리시간 0.018초

지형공간정보 기반의 침투위험도 예측 모델을 이용한 최적침투지역 분석 (Analysis of Infiltration Area using Prediction Model of Infiltration Risk based on Geospatial Information)

  • 신내호;오명호;최호림;정동윤;이용웅
    • 한국군사과학기술학회지
    • /
    • 제12권2호
    • /
    • pp.199-205
    • /
    • 2009
  • A simple and effective analysis method is presented for predicting the best infiltration area. Based on geospatial information, numerical estimation barometer for degree of infiltration risk has been derived. The dominant geospatial features influencing infiltration risk have been found to be area altitude, degree of surface gradient, relative direction of surface gradient to the surveillance line, degree of surface gradient repetition, regional forest information. Each feature has been numerically expressed corresponding to the degree of infiltration risk of that area. Four different detection probability maps of infiltration risk for the surveillance area are drawn on the actual map with respect to the numerically expressed five dominant factors of infiltration risks. By combining the four detection probability maps, the complete picture of thr best infiltration area has been drawn. By using the map and the analytic method the effectiveness of surveillance operation can be improved.

Comparison of Infiltration Induced in Veins of Rabbit's Ear and Human's Forearm by Using Bioelectrical Impedance: Pilot Study

  • Kim, Jae-Hyung;Hwang, Young-Jun;Kim, Gun-Ho;Shin, Beum-Joo;Kim, Yong-Jin;Lee, Eun-Joo;Jeon, Gye-Rok
    • 센서학회지
    • /
    • 제26권5호
    • /
    • pp.306-313
    • /
    • 2017
  • An early detection of infiltration in veins is essential to minimize the injuries caused during infusion therapy, which is one of the most important tasks for nurses in clinical settings. We report that bioelectrical impedance analysis is useful in the early detection of infiltration at puncture sites. When infiltration was intentionally induced in the vein of a rabbit's ear, impedance parameters showed significant difference before and after infiltration. In particular, the relative resistance at 20 kHz in the vein of rabbit's ear reduced largely at infiltration, decreased slowly, and then stayed at a constant value. This indicates that the vein in the ear of the rabbit is small, and hence the infiltrated intravenous (IV) solution no longer accumulates after 3 minutes of infiltration. However, when infiltration was induced in the vein of a human's forearm, the relative resistance at 20 kHz decreased gradually over time. In the $R-X_c$ graph, the positions in infiltration induced in the rabbit's ear rapidly shifted before and after infiltration whereas the positions in infiltration induced in the human's forearm changed gradually during infiltration. Our findings suggest that bioelectrical impedance analysis is an effective method to detect the infiltration early in a noninvasive and quantitative manners.

조립식 저류형 침투시설의 설계 및 공간적용 효과분석 (Design and Effectiveness Analysis of prefabricated Storage-type infiltration facility)

  • 이태구
    • KIEAE Journal
    • /
    • 제16권6호
    • /
    • pp.103-108
    • /
    • 2016
  • Purpose: This study has developed economical and environmentally friendly storage type infiltration facilities that securing storage space inside the infiltration facility. It focused on preventing flooding rainfall as well as securing more groundwater through rainwater infiltration that is valuable for the dry season. In addition, this study compares the installation cost of the storage-type infiltration facility to the cost of the conventional rainwater management facilities to demonstrate the economic efficiency of the storage-based infiltration facility. Method: Unit infiltration of this facility is calculated and when it was applied to a certain capacity, the amount of countermeasures are proposed in case study. Result: Unit infiltration of it is $0.2541m^3/hr$ and un it Temporary storage of it is $1.054m^3/m$. As a result, the infiltration effect of this facility is $1.306m^3/hr$. The cost was approximately 30% reduction in time to apply the storage type infiltration facility as compared with the case to apply the existing penetration of the facilities. Since the penetration of the existing facilities is smaller than that and it has much securing volume to process the same the amount of countermeasures. Therefore, it is determined that the cost significantly increases in material cost part. On the other hand, storage type infiltration facility is installed a small quantity because Unit Temporary storage and infiltration are bigger than that. So, it occurred to reduce material and installation costs.

금속기복합재료의 부품 제조공정에 관한 함침제어알고리즘 개발 및 평가 (Algorithm Development for Infiltration Control in Component Fabrication Process of Metal Matrix Composites and Their Evaluation)

  • 강충길;윤광식
    • 한국주조공학회지
    • /
    • 제16권6호
    • /
    • pp.523-536
    • /
    • 1996
  • This paper relates to fabrication processing analysis of metal matrix composites by the injection of liquid metal into a fibrous preforms. One dimensional heat transfer analysis during squeeze infiltration process of aluminum base composites has been studied. An analysis method was investigated for the temperature distribution, infiltration velocity and melt infiltration characteristics with the commercial preform with short fiber array. When molten metal is infiltrated in a fibrous preform with random orientation, phase transformation will be occurred in a region such as molten metal, solidified region, preform region and infiltration composites region. a mathematical modelling for a solidification phenomena in fabrication process of metal matrix composites using a squeeze infiltration technique was investigated by the basic relations for liquid metal into a fibrous preform. The temperature distribution of theoretical results was compared with experimental data.

  • PDF

Early Detection of Infiltration Induced in the Veins of Pig's Ear and Human's Forearm By Using Bioimpedance: Pilot Study

  • Kim, Jaehyung;Hwang, Youngjun;Kim, Gunho;Jeong, Ihn Sook;Jeon, Gyerok
    • 한국멀티미디어학회논문지
    • /
    • 제21권1호
    • /
    • pp.34-44
    • /
    • 2018
  • An early detection of intravenous (IV) infiltration is essential to minimize the injuries during infusion therapy, which is one of the most important tasks for nurses in nursing settings. We report that bioelectrical impedance analysis is useful in the early detection of infiltration at puncture sites. When infiltration was intentionally induced in the vein of a pig's posterior ear, impedance parameters (R, $X_C$, $C_m$) showed significant differences before and after infiltration. In particular, the relative resistance ($R/R_{BI}$) decreased significantly at infiltration and then slowly decreased. This indicates that the vein in pig's ear is thin and the amount of surrounding subcutaneous tissue, and hence the infiltrated solution accumulates slowly after infiltration. However, when infiltration was induced in the vein of human's forearm, the relative resistance at 20 kHz decreased gradually over time. In the $R-X_C$ graph, the positions in the case of infiltration induced in the pig' ear shifted rapidly before and after infiltration, whereas the positions in the case of infiltration induced in the human's forearm moved gradually during infiltration. Our findings suggest that the impedance parameters (R, $R/R_{BI}$, $X_C$, R vs. $X_C$, and $C_m$) are effective indicators to detect the infiltration early in a non-invasive and quantitative manners.

하수관거정비사업의 침입수/유입수 산정 및 활용방법 개선방안에 관한 연구 (A Study on Improvement of Inflow/Infiltration Computation and Application Method in Sewer Rehabilitation Project)

  • 김종오;정동기;안대훈
    • 상하수도학회지
    • /
    • 제28권1호
    • /
    • pp.33-45
    • /
    • 2014
  • In this study, current sewer infiltration/Inflow(I/I) computation and application method was examined about improvement and adequacy relating to the main issues raised by the field for practitioners. The results of review about infiltration calculation method were considered to be in need of improvement at 'standards of minimum sewage calculation'. Furthermore, the results of review about I/I application method were considered to be in need of improvement at 'standards of seasonal infiltration application' and 'the relative decrease in the Annual evaluation standards'. In addition, annual I/I analysis at JC County for the four years(2009~2012) in respect of operation flow and rainfall data was conducted. The result of annual infiltration analysis, compared average daily sewage generated average infiltration rate was found in 21.95 %, infiltration by unit was found in $0.31m^3/day/cm/km$ and $0.12m^3/day/day$, respectively. The result of annual inflow analysis, average rainfall - Inflow equations was found $y=5.499{\times}$($R^2$ 0.793), and the average Inflow quantity by sewer extension was predicted to $0.66m^3/mm-km$.

제주도에 계획된 침투저류지의 수문학적 분석 사례 (A Hydrologic Analysis for the Infiltration Storages Planned on Jeju-do)

  • 이상호;이정민;강태욱;강신욱
    • 한국물환경학회지
    • /
    • 제26권6호
    • /
    • pp.1040-1048
    • /
    • 2010
  • An infiltration storage can be installed as a method of reducing runoff from catchment and increasing stream flow during the dry period by recharging groundwater. However, there is no proper model and method that can be used to design storage capacity of an infiltration storage in Korea. The purpose of the study is to evaluate capacities of infiltration storages planned on Jeju-do in Korea by modifying Storm Water Management Model (SWMM). The basic equations for the infiltration storage are same as those of the infiltration trench used in MIDUSS. Infiltration rates of the infiltration storages were first measured by double ring infiltrometers, and then the modified model was applied to evaluate adequacy for the capacities of three infiltration storages planned on Jeju-do in Korea. The application results show that the two infiltration storages with higher infiltration rates have adequate capacities to infiltrate the total water inflow to the storages. However, the other infiltration storage with lower infiltration rates has not sufficient capacity to infiltrate the total water inflow to the storage and release occurs to the downstream region. The simulation model and method applied can be used for capacity evaluation of future infiltration storages on highly pervious areas in Jeju-do.

강우침투에 대한 불포화 토사사면의 확률론적 안정해석 (Probabilistic Stability Analysis of Unsaturated Soil Slope under Rainfall Infiltration)

  • 조성은
    • 한국지반공학회논문집
    • /
    • 제34권5호
    • /
    • pp.37-51
    • /
    • 2018
  • 우리나라의 산지사면은 풍화잔류토 층의 깊이가 얕아 강우의 침투로 인한 사면파괴가 많이 발생한다. 이때 파괴면의 깊이는 얕고 토사층과 기반암의 경계면 근처를 통과하는 특징을 가지고 있다. 강우의 침투로 인한 불포화 토사사면의 불안정성에 중요한 영향을 미치는 지반 정수들은 큰 불확실성을 포함한다. 따라서 본 연구에서는 강우로 인한 사면파괴를 예측하기 위하여 지반의 수리학적 특성과 강도특성을 랜덤변수로 고려하는 몬테카를로 시뮬레이션에 의한 확률론적 해석 절차를 제안하였다. 일정한 강우강도에 대한 기반암이 얕게 존재하는 불포화 토사사면의 안정성 예측을 위하여 강우강도에 따른 사면 표면에서의 경계조건을 반영하여 Green-Ampt 모델을 수정하고 얕은 기반암의 경계조건을 도입하였다. 침투해석의 결과를 무한사면 해석에 적용하여 안전율을 계산하였다. 제안된 확률론적 해석법은 강우의 침투에 따른 사면의 시간 의존적 파괴확률을 계산할 수 있다.

화강풍화토의 불포화 침투특성에 관한 연구 (Infiltration Characteristics for Unsaturated Residual Soil)

  • 김영욱;김도형;성상규;이인모
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.147-152
    • /
    • 2001
  • This study investigated one-dimensional vertical infiltration to an unsaturated residual soil by numerical solutions, FDM. In order to estimate the parameters needed for numerical analysis, tire soil-water characteristic curve(SWCC) of Shinnae-dong soil, one of the most typical residual soils in Korea, were experimentally obtained. Then, the statistical analysis for obtaining the SWCC was performed. The numerical solution to the linearized governing equation for unsaturated groundwater flow provides the infiltration characteristics for the unsaturated residual soil represented by transient pressure profiles and water contents profiles.

  • PDF

Numerical Study of Unsaturated Infinite Slope Stability regarding Suction Stress under Rainfall-induced Infiltration Conditions

  • Song, Young-Suk;Hwang, Woong-Ki
    • 지질공학
    • /
    • 제24권1호
    • /
    • pp.1-8
    • /
    • 2014
  • Numerical stability analysis of an unsaturated infinite slope under rainfall-induced infiltration conditions was performed using generalized effective stress to unify both saturated and unsaturated conditions The soil-water characteristic curve (SWCC) of sand with a relative density of 75% was initially measured for both drying and wetting processes. The hydraulic conductivity function (HCF) and suction stress characteristic curve (SSCC) were subsequently estimated. Under the rainfall-induced infiltration conditions, transient seepage analysis of an unsaturated infinite slope was performed using the finite element analysis program, SEEP/W. Based on these results, the stability of an unsaturated infinite slope under rainfall-induced infiltration conditions was examined in relation to suction stress. According to the results, the negative pore-water pressure and water content within the slope soil changed over time due to the infiltration. In addition, the variation of the negative pore-water pressure and water content led to a variation in suction stress and a subsequent change in the slope's factor of safety during the rainfall period.