• Title/Summary/Keyword: Infiltration Area Analysis

Search Result 157, Processing Time 0.023 seconds

Analysis on the Water Circulation and Water Quality Improvement Effect of Low Impact Development Techniques by Test-Bed Monitoring (시범 단지 운영을 통한 LID 기법별 물순환 및 수질개선 효과 분석)

  • Ko, Hyugbae;Choi, Hanna;Lee, Yunkyu;Lee, Chaeyoung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.5
    • /
    • pp.27-36
    • /
    • 2016
  • Low Impact Development (LID) techniques are eco-friendly storm water management process for water circulation restoration and non-point pollutant reduction. In this study, four LID techniques (Small constructed wetland, Infiltration trench box, Infiltration trench, Vegetated swale) were selected and installed as a real size at the real site. All facilities were evaluated as monitoring under the real environmental climate situation and an artificial rain with exceeding design rainfall. In various rainfall, runoff reduction efficiency and non-point pollutant removal efficiency are increased to the bigger Surface Area of LID (SA)/Catchment Area (CA) ratio and the bigger Storage Volume of LID (SV)/Catchment Area (CA) ratio. Runoff did not occur at all rainfall event (max. 17.2 mm) in infiltration trench and vegetated swale. But Small constructed wetland was more efficient at less than 10 mm, a efficiency of infiltration trench box was similar at different rainfall. Although different conditions (such as structural material of LID, rainfall flow rate, antecedent dry periods), LID techniques are good effects not only water circulation improvement but also water quality improvement.

Correlation between Fatty Infiltration of Lumbar Paraspinal Muscle and Slip Percentage on 45 Korean Medicinal Treatment Cases of Spondylolisthesis: A Retrospective Study (척추전방전위증 환자 45예의 요추주변근육의 지방침착도와 전위정도의 상관성에 대한 후향적 연구)

  • Kim, Yu-Gon;Kim, Dae-Ho;Jeong, Hyeon-Gyo;Lim, Jin-Woong;Kim, Yong-Hwa;Kang, Deok;Jeong, Hwe-Joon;Shin, Kyung-Moon;Shin, Dong-Hoon;Yang, Jae-Woo;O, Ji-Hoon;Cho, Jae-Seong
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.32 no.1
    • /
    • pp.51-62
    • /
    • 2022
  • Objectives Objective of this study is to investigate the role of paraspinal muscles by examining the correlation between slip percentage (SP) of spondylolisthesis and fatty infiltration of lumbar paraspinal muscle. Methods Retrospective analysis was performed on 45 patients diagnosed with spondylolisthesis based on medical records. Using T2-weighted axial magnetic resonance imaging, cross-sectional areas (CSAs) of psoas major (PM), multifidus (MU) and erector spinae (ES) were calculated and divided by CSA of lower level vertebral body (VB). SP was measured using sagittal T2-weighted images. Correlation of SP with muscle relative cross-sectional area (RCSA) and muscle fatty infiltration by Goutallier classification was respectively analyzed using Spearman correlation. Statistic assessment conducted by Wilcoxon signed rank test and paired t-test using program GraphPad prism 5 (GraphPad Software, Inc., San Diego, CA, USA). Results Spondylolisthesis forward slip percentage by Taillard's method was negatively associated with both side MU RCSAs. No significant correlation was found between PM RCSA, ES RCSA and SP. Forward slippage was significantly correlated with fatty infiltration of lumbar paraspinal muscle measured by Goutallier classification. Conclusions This study is to understand the role of paraspinal muscle affecting spinal instability by investigating correlation between statistical deviation of lumbar muscle characters (RCSA, fatty infiltration of lumbar muscle) and SP. We found that spondylolisthesis SP is positively related to fatty infiltration of lumbar paraspinal muscle. and is negatively associated with both side MU RCSAs.

A Study of Optimal-CSOs by Continuous Rainfall/Runoff Simulation Techniques (연속 강우-유출 모의기법을 이용한 최적 CSOs 산정에 관한 연구)

  • Jo, Deok Jun;Kim, Myoung Su;Lee, Jung Ho;Kim, Joong Hoon
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.1068-1074
    • /
    • 2006
  • For receiving water quality protection a control systems of urban drainage for CSOs reduction is needed. Examples in combined sewer systems include downstream storage facilities that detain runoff during periods of high flow and allow the detained water to be conveyed by an interceptor sewer to a centralized treatment plant during periods of low flow. The design of such facilities as storm-water detention storage is highly dependant on the temporal variability of storage capacity available as well as the infiltration capacity of soil and recovery of depression storage. For the continuous long-term analysis of urban drainage system this study used analytical probabilistic model based on derived probability distribution theory. As an alternative to the modeling of urban drainage system for planning or screening level analysis of runoff control alternatives, this model has evolved that offers much ease and flexibility in terms of computation while considering long-term meteorology. This study presented rainfall and runoff characteristics of the subject area using analytical probabilistic model. Runoff characteristics manifested the unique characteristics of the subject area with the infiltration capacity of soil and recovery of depression storage and was examined appropriately by sensitivity analysis. This study presented the average annual CSOs, number of CSOs and event mean CSOs for the decision of storage volume.

Characteristics and Combined Sewer Overflows (합류식 하수관거의 유출 특성 분석 조사)

  • An, Ki-Sun;Jang, Sung-Ryong;Kwon, Young-Ho
    • Journal of Environmental Science International
    • /
    • v.19 no.6
    • /
    • pp.747-753
    • /
    • 2010
  • It follows in quality and sewage exclusion method of the investigation objective sector and the Combined Sewer Overflows which is suitable in regional characteristics and the confluence area against the rainfall initially a flow and the medulla and measurement - it analyzes the initial rainfall outflow possibility control plan which is suitable in the domestic actual condition and it proposes the monitor ring plan for the long-term flow and pollution load data accumulation. From the research which it sees the Infiltration water/Influent water and CSOs investigation it passes by the phase of hazard chain and Namwon right time 4 it does not hold reverse under selecting, Measurement it used the hazard automatic flow joint seal Sigma 910 machine and in case 15 minute interval of the I/I, it measured a flow at case 5, 15 minute standing of the CSOs. The water quality investigation for the water leakage investigation of the I/I and the sewage from the point which is identical with flow measurement during on-the-spot inspection duration against 6 items which include the BOD sampling and an analysis, when the rainfall analysis for CSOs fundamental investigation analyzed against 18 items which include the BOD sampling. Consequently, for the optimum interpretation invasion water / inflow water of the this investigation area day average the lowest flow - water quality assessment veterinarian optimum interpretation hazard average per day - lowest flow - it averages a medulla evaluation law department one lowest flow evaluation technique and it selects, it presentation collectively from here it gets, position result with base flow analysis of invasion water / inflow water.

Return flow analysis of paddy field by water balance method (물수지분석 기법에 의한 논에서의 회귀율 조사분석)

  • 정상옥;손성호
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.43 no.2
    • /
    • pp.59-68
    • /
    • 2001
  • A water balance analysis was performed for a paddy field neighboring the Dongchang stream, downstream of the Unmun reservoir, which is constructed for the urban water supply. Daily rainfall data were collected and irrigation water flow rate, drainage flow rate, evaportranspiration, infiltration, and piezometeric head were measured in the field. The flow rates were continuously observed by water level logger during the growing season. The evaportranspiration and the infiltration were measured by N-type depletion meter and cylindrical infiltrometer, respectively. PVC pipes with 12mm diameter were used for piezometric head measurement. Total Irrigation and drainage flows were 3,608mm and 1,170mm in 1999, and 3,971mm and 1,548mm in 2000, respectively. The mean and range of the daily infiltration rate were 4.4mm/d and 3.4mm/d to 5.5mm/d in 1999 and 5.1mm/d and 4.1mm/d to 6.5mm/d in 2000, respectively. The net ground water flow including the change of soil water storage was 2,855mm in 1999 and 2,540mm in 2000. The evapotranspiration was 458.3mm in 1999 and 553.5mm in 2000. The range of daily evapotranspiration rate was from 1.6 to 8.7mm/d. The return flow ratio was about 32% in 1999 and 39% in 2000 and three year average was 35% including previous study in 1997. The amount of irrigation water was much higher than design standards or references in this study, This was caused by the inadequate water management practice in the area where water was oversupplied on farmers’ request rather than following sound water management principles.

  • PDF

A Comparative Analysis of Stormwater Runoff with Regard to Urban Green Infrastructure - A Case Study for Bundang Newtown, SungNam - (도시 녹지기반 특성에 따른 강우 유출수 비교 분석 - 성남시 분당신도시를 사례로 -)

  • Park, Eun-Jin;Kang, Kyu-Yi;Lee, Hyun-Jung
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.11 no.6
    • /
    • pp.1-10
    • /
    • 2008
  • The study was aimed at analyzing the relationship between the characteristics of urban green infrastructure and stormwater runoff in a small urban watershed composed of 22 drainage basins. The green areas of which soils are not sealed and allow water infiltrate, were examined for different types of green spaces. In a comparative study for drainage basins of which green spaces are 15.5% and 34.4%, respectively, runoffs were not different with the size of green space. It was attributed to that the increase of runoff by greater road area offset the advantage of greater green area. Another comparative measurement of runoff for drainage basins with similar green area size showed that runoff decreased with greater permeable area (school ground area) and smaller road area. The runoff measurements could address that runoff rates are affected not only by green area size but also by the type of green area and other land covers related to permeability and flow into drainage. It implicated that the improvement of urban green infrastructure as a functional unit for water infiltration and interception is important for stormwater runoff management.

Water Balance in a Paddy Field with Pumping Irrigation System (양수장 용수공급 논 지대의 물수지)

  • 정운태;이근후;이인영
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.1-7
    • /
    • 1998
  • To investigate the water balance in a paddy rice field with the pumping station for irrigation water supply, flow measurements and analysis on various components of water balance were carried out. The investigated area is 103.7 ha, and the irrigation water was supplied for 102 days during the total irrigation period starting from June 1. It was found that the consumption rate was increased as the growing stage was progressed. The variation of evapotranspiration rate was shown same tendency as the consumption rate, while no apparent tendency was found in infiltration rate upon different growing stages. And the ground water input to the area was predominant during the early stage of growing period, while ground water output from the study area was predominant at the end of the growing stage. The range of return flow rate, the ratio of total outflow to total inflow in every decad, was 57.6 to 85.7%. These values are slightly higher than reported values from the other investigation projects.

  • PDF

Analysis for Rainfall Infiltration Using Electrical Resistivity Monitoring Survey (강우 침투 특성 분석을 위한 전기비저항 모니터링 탐사)

  • Kim, Sung-Wook;Choi, Eun-Kyeong;Park, Dug-Keun;Yoon, Yeo-Jin;Lee, Kyu-Hwan
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.7
    • /
    • pp.41-53
    • /
    • 2012
  • During rainfall period, to identify the characteristics of the infiltration of moisture, electrical resistivity monitering survey was carried out to weathered zone. Four regions of geophysical exploration areas with different rock types, four regions were selected. An area consists of mafic granite and three areas are composed of sedimentary rocks (Sandstone, Shale, Unconsolidated Mudstone). Survey was conducted from June (rainy season) to November (dry season), and during the period the change in resistivity was observed. According to the result of monitoring exploration on Geumjeong and Jinju areas, for the estimation of the standard rainfall, it is necessary to estimate the effects of the antecedent rainfall during the rainy season based on the overall rainfall from June till October and also necessary to consider this for the estimation of the half period. Also, the vertical distribution of the low resistivity anomaly zone does not show that the infiltration of moisture does not occur uniformly from the surface of the ground to the lower ground but shows that it occurs along the relaxed gap of the crack or soil stratum of the weathering zone. In Pohang area, the type of moisture infiltration is different from that of the granite or sedimentary rock. Since, after the rainfall, the rate of infiltration to the lower ground is high and the period of cultivation to the lower bedrock aquifer is short, it has similar effect to that of the antecedent rainfall applied for the estimation of the standard rainfall being presently used. In Danyang, due to the degree of water content of the ground, the duration period of the low resistivity anomaly zone observed in the lower ground of the place where clastic sedimentary rock is distributed is similar to that in Pohang area. The degree of lateral water diffusion at the time of localized heavy rain is the same as that of the sedimentary rock in Jinju. According to the above analysis results, in Danyang area, the period when the antecedent rainfall has its influence is estimated as three weeks or so.

Analysis of Runoff Reduction Effect of Infiltration Facility Installation Position and Kinds of Infiltration in Urban Basin (도시유역의 침투시설 설치위치와 종류에 따른 유출저감효과 분석)

  • Lee, Jae-Joon;Kwak, Chang-Jae;Seol, Ji-Su
    • 한국방재학회:학술대회논문집
    • /
    • 2010.02a
    • /
    • pp.54.2-54.2
    • /
    • 2010
  • 본 연구는 침투시설의 설치위치와 종류에 따른 유출저감효과를 WinSLAMM 모형을 이용하여 분석한 것이다. 본 연구의 대상유역은 Driveway 38%, Residential Area 8%, Parking Storage 8%, Sidewalk 8%, Playground 8%, 투수유역(Landscaped Area) 30%와 같이 토지이용별로 구획된 총면적 $0.25km^2$의 전형적으로 도시화된 가상유역으로 설정하였다. 침투시설 설치에서 중요한 요소 중 하나인 시설의 포화를 고려하기 위하여 10mm/hr~30mm/hr범위의 강우를 적용하였으며, 설치위치와 종류별 침투시설의 정량적인 유출저감효과를 비교하기 위하여 Residential Area, Parking Storage, Playground와 같은 유역내 불투수유역과 유출구에 해당하는 Outfall에 일정한 규모의 침투트렌치와 침투통을 설치하였다. 침투시설은 강우의 크기에 따라 시설의 포화가 진행되며 일정 규모 이상의 강우 발생시 침투기능을 상실하므로 강우의 크기에 맞는 포화시점을 찾아 적절한 규모로 설치해야하고, 경호우에서 유역내의 침투시설의 가용면적을 증가시키면 유출저감효과도 증가하였으나, 강우가 커질수록 상대적으로 가용면적이 큰 유출구와 차이가 없거나 오히려 더 낮은 유출저감효과가 나타나기도 하였다. 또한 설치위치에 침투시설을 비교한 결과, 경호우의 경우 동일한 유출저감효과가 나타났으나, 침투트렌치가 포화에 이루어지기 전까지는 유출저감효과가 더 높았으며, 유출구에서는 침투트렌치가 침투통보다 더 높은 유출저감효과가 나타났다. 침투시설의 병행설치시 경호우에서는 병행설치의 효과가 없었으나 강우강도가 증가할수록 효과가 뚜렷하게 나타났고, 유역내 침투시설의 병행설치시 가용면적을 증가시킬수록 유출저감효과도 증가하여 경호우 이상의 강우에서 병행설치를 고려되어야한다는 결론을 얻었다.

  • PDF

The Study of Fat Infiltration Ratio in Lumbar Paraspinal Muscle of Patient with Herniated Intervertebral Lumbar Disc (요추간판 수핵 탈출증 환자의 요부 척추 주위근 내 지방침윤 비율에 관한 연구)

  • Kong, Bong-Jun;Lee, Jung-Ho;Yong, Min-Sik;Kim, Jin-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5254-5260
    • /
    • 2012
  • The purpose of this study is to find the relationship between lumber Herniated Nuclesus Pulposus of specific part and fat infiltration in paraspinal muscle. Also we intended to find the relationship between Body Mass Index(BMI) and fat infiltration ratio in the lumber paraspinal muscle based on the sexes of patients. We conducted this study of patients who visited our hospital from May, 2010 to May, 2012. The subjects are composed of 40 patients(20 females and 20 males), who are 30 to 50 years old suffering from severe lumber herniated nuclesus pulposus, who had or were going to have operation treatment. BMI is measured through anthropometry of each patient and fat infiltration inside the muscle is estimated by measuring the cross section area of lumbar paraspinal muscle from mid-cross section of disc(L2-S1) and fat infiltration ratio. The data of this study are analyzed by independent t-test to figure out the difference of fat infiltration between male and female, and by paired sample T-test after getting mean and standard deviation to find the changes of fat infiltration of lumbar on each level. Also correlation analysis is done by setting age as a control variable to find the correlation between BMI and fat infiltration of the whole lumbar. As a result, we could get only the meaningful difference between the sexes on upper lumber part(L2-L3) while we couldn't find any significant difference in the rest of lumbar(L3-S1). Besides, the changes of fat infiltration ratio on each lumbar level increased rapidly from lumbar 3,4 to lumbar 4,5. We also found that there is no correlation between fat infiltration ratio of lumbar paraspinal muscle(L2-S1) and BMI.