• 제목/요약/키워드: Industrial hood

검색결과 61건 처리시간 0.023초

일부 대학 내 연구실험실의 보호구 및 흄후드 관리 실태에 관한 연구 (A Study on the Status of Management for Personal Protective Equipments & Fume Hoods in University Research Laboratories)

  • 박인규;이사우;정종현;피영규
    • 한국산업보건학회지
    • /
    • 제24권2호
    • /
    • pp.229-237
    • /
    • 2014
  • Objectives: This study intends to determine the current status of management of personal protective equipment fume hoods in university laboratories. Methods: A walk-through survey of 402 labs in Gyeongbuk Province and Daegu Metropolitan City were carried out between May 2009 and July 2010. Respectively, 348 and 54 laboratories were examined in Gyeongbuk Province and Daegu. Results: In size, labs serving over 15,000 student made up the majority with 276(66.4%). In terms of major, engineering labs were the highest in number with 100(24.9%). As to personal protective equipment, a gas mask and a dust mask were available in 17.8% and 14.3% of the labs, respectively, but 68.9% of labs were equipped with protective goggles. Meanwhile, only 12.7% of labs had separate protective equipment storage boxes. About 60% of the labs had installed a fume hood, of which the average capture velocity was 0.37 m/sec. Conclusions: For toxic substances, the labs are obliged to provide personal protective equipment in in accordance with the Occupational Safety and Health Act. In addition, the capture velocity of fume hoods must be in strict compliance in order to prevent occupational diseases due to toxic chemicals.

중소기업 도금공정에서의 6가 크롬 폭로에 관한 연구 (A Study on Worker Exposure to Hexavalent Chromium in Plating 0peration)

  • 정희경;백남원
    • 한국산업보건학회지
    • /
    • 제3권2호
    • /
    • pp.152-165
    • /
    • 1993
  • This study was performed at eleven small-sized plating factories located in Seoul, Incheon, Ansan, and Taejeon from July 21 to October 6, 1992. The major objectives of this study were to evaluate worker exposure to hexavalent chromium and local exhaust ventilation (L.E.V.) systems at the chromium plating operations. The most suitable L.E.V. systems for chromium plating tanks were designed as examples for recommendation to the industry. The results are summarized as follows. The range of chromium plating operations investigated included decorative, hard, and black chromium plating on several kinds of parts. Most of plating tanks were not equipped with proper control methods against emission of hexavalent chromium mists and workers were not wearing appropriate personal protectives. The ariborne hexavalent chromium concentrations showed an approximate lognormal distribution. The geometric means of both personal and area samples were within the Korean and ACGIH standards, $50{\mu}g/m^3$. However, in comparison with the NIOSH criterion, $1{\mu}g/m^3$, the geometric means of personal samples at two factories and the geometric means of area samples at two factories exceeded it. The geometric means of personal and area samples of high exposure groups (above the NIOSH criterion) were 7 and 27 times higher than those of low exposure groups (below the NIOSH criterion), respectively. The L.E.V. systems of high exposure groups were improperly designed, and the factory with the highest exposure level had no L.E.V. systems at all on chemical etching process. Whereas at factories of low exposure groups, mist control methods such as mist suppressants, tank cover, and/or auxillary L.E.V. systems were added to L.E.V systems. The evaluation of L.E.V. systems showed that there was no chromium plating operation satisfying the ACGIH criteria for capture velocity, slot velocity, and exhaust rate simultaneously. To increase performance of L.E.V. systems, it must be designed to minimize the impact of boundary layer separation. Push-pull ventilation hood and downward plenum ventilation hood were suggested for the Korean industry.

  • PDF

급성 규폐증이 발생한 규조토 분말 취급 작업장의 결정형 실리카 노출평가: 역학조사 사례 (Exposure Assessment of Crystalline Silica in Diatomite Powder Handling Workplace with Acute Silicosis)

  • 김부욱;김대호;김형렬;최병순
    • 한국산업보건학회지
    • /
    • 제29권3호
    • /
    • pp.271-277
    • /
    • 2019
  • Objectives: A 46-year-old woman who had worked on cleaning stainless steel containers with Initially unknown powders died from acute silicosis. To determine whether the acute silicosis was related to his work environment, we conducted exposure assessment the level of exposure to respirable crystalline silica(RCS) during cleaning stainless steel containers with unknown powders. Methods: The exposure assessment of RCS were undertaken according to the National Institute for Occupational Safety and Health(NIOSH) method 7500. The components of the unknown powder were analyzed using X-ray Diffraction. Results: The unknown powder was found to be natural diatomaceous earth, which contained 12% and 9% quartz and cristobalite, respectively, crystalline silica. In the case of cleaning stainless steel containers with diatomaceous earth powder, the primary measurement resulted in 1.3 times higher occupational exposure limit of MOEL(in sum of quartz and cristobalite concentration) and 3.9 times higher in secondary measurement. The workbench was equipped with a local exhaust system, but because there was no hood at the end of the duct, the wind speed at the opening of the duct was 12 m/sec, whereas the controlled wind speed at the working position was only 0.3 m/sec below the legal standard. Conclusions: There is an urgent need to install the hood, conduct safety and health education for employers and workers, and periodically monitoring and manage the working environment.

DMF를 사용하는 합성피혁 공장 인쇄공정의 산업환기시스템 평가 및 개선 (A Valuation and Improvement of Industrial Ventilation System of Printing Process in Synthetic Leather Factory using Dimethylformamide)

  • 이선우;김태형;김정만;김종철
    • 한국산업보건학회지
    • /
    • 제19권2호
    • /
    • pp.113-126
    • /
    • 2009
  • In the recent years, health effect of dimethylformamide(DMF) has been one of critical industrial hygiene issues. There might be many factors to increase the exposure level of DMF. Among those factors, industrial ventilation would be one of the main factors. In this study, industrial ventilation systems of printing processes in synthetic leather factories were thoroughly surveyed and the improved ventilation systems were proposed. 7 synthetic leather factories were selected for this study. After the ventilation systems were visually inspected, each component of the system was tested by using the appropriate instruments. Hood face velocities, fan exhaust flow rates, fan static pressures, fan rotation rates, etc were measured. In addition, flow visualization techniques were used to observe flow patten around hoods and inside the factory buildings. After gathering all qualitative and quantitative information, the test results were analysed to see if any improvement might be necessary. For the system to be improved, the re-design plans were made by using computational fluid dynamics softwares. The softwares used in this study were AIRPAK and STAR-CD. The effectiveness of the several improvement options were tested, then the best cost effective option was selected. Finally, the standard ventilation systems were proposed to minimize the exposure levels of DMF.

Ergonomic Evaluation of Some University Laboratories

  • Lee, Yun Keun;Lee, Ik Mo;Park, Jeongim;Yoon, Chung Sik;Rhie, Kwang Won;Park, Hee Sok
    • 대한인간공학회지
    • /
    • 제32권4호
    • /
    • pp.397-403
    • /
    • 2013
  • Objective: This article aims to report the results of ergonomic evaluation of some university laboratories. Background: Laboratory researchers are at risk for musculoskeletal injuries during routine laboratory procedures. However, little attention has paid to the working conditions of laboratory researchers, especially in Korea. Method: A checklist and questionnaire was developed and used to analyze the work conditions of 27 laboratories of chemistry, biology and pharmacy. Results: It was found that glove box, clean bench, and computer workstation are better than microscopy, and fume hood tasks, from ergonomic point of view. Conclusion: No domestic guideline is available for ergonomic intervention of laboratories. Further attention and studies are anticipated to improve the working conditions of laboratories.

아연도금 부스 환기시스템 개선에 관한 수치해석 (Numerical Analysis on the Improvement of Zinc Plating Booth Ventilation System)

  • 진도훈
    • 한국산업융합학회 논문집
    • /
    • 제24권1호
    • /
    • pp.45-51
    • /
    • 2021
  • The purpose of this study is to suggest the optimal shape for a local air ventilation system for fume removal, which is operated in a zinc galvanizing factory, and to propose the improvement plan for a ventilation system used in a zinc galvanizing factory through flow analysis. A part of the air sprayed by an air curtain goes out. It will be necessary to research the position of an air curtain, its spray angles, and its nozzle shape. In addition, additional research needs to be conducted on the shape of the fan installed before a hood in order to make it easy to induce fume. In a local air ventilation system, air is inhaled from the outside. The higher an inlet negative pressure is, the easier fume is removed. It was found that it was necessary to install an appropriate hole in the wall on the back of a push nozzle in order to reduce an inlet negative pressure.

일부 산업보건관련 기관의 분석실험실 안전보건에 관한 실태와 대책 (A Survey and Recommendation on Safety and Health for Occupational Health Laboratories)

  • 유계묵;노영만;한진구;원정일
    • 한국산업보건학회지
    • /
    • 제10권2호
    • /
    • pp.150-164
    • /
    • 2000
  • This study was conducted at occupational health laboratories in Seoul and Gyunggi district area from December, 1999 to January, 2000. The main purpose of this study was to survey the actual condition of safety and health by questionnaire and checklist and to assess the performance of fume hoods and the airborne exposures to chemicals in the laboratories. The chemicals in the cabinet were not classified by hazardous properties and the compressed gases were not stored safely. The prevalences of laboratories having first aid kits, fire extinguishers, and safety showers were found to be 18%, 55%, and 9%, respectively. Most laboratory workers were not educated for safety and health. Also, there was no performance evaluation for hazards and risks. The fume hoods in laboratories had not been annually inspected by checklist and the face velocity had been checked more than one time in the previous year for only 18% of them. Five percent of fume hoods had the face velocity more than 4.0 m/sec and 17% had no capture performance. Detected organic solvents were methylenechloride, acetone, ethylbenzene, isopropanol, xylene, methylisobutylketone, trichloroethylene, and toluene. The concentrations of organic solvents were much less than the occupational exposure limits proposed by the Ministry of Labor in Korea. This study showed that the actual condition of safety and health was not appropriate for laboratory workers. It is recommended that laboratory workers should be educated for the treatment and storage of hazardous chemicals and compressed gases to improve the working environment of the occupational safety and health laboratories.

  • PDF

주물 공단 용해공정의 송풍기 및 백필터 관리 실태 (The Status of Maintenance of Exhaust Fans and Bag filters in Melting Processes in a foundry industrial complex)

  • 김태형;하현철;정춘화;서정윤;박승욱;양준호;이효우
    • 한국산업보건학회지
    • /
    • 제17권3호
    • /
    • pp.212-223
    • /
    • 2007
  • 18 Local exhaust ventilation systems in 10 melting companies located in an industrial complex were tested to know the status of maintenance. Test items were fan flowrates, fan static pressures, rotational speeds and differential pressures of bag filters. Only 22% of the tested fans has more than 80% flowrate efficiency. 44% of the fans has lower than 60% efficiency. The performance of the fans are not in a good status. For the fans with lower than 60% efficiency, the analysis shows that the lower flowrate might be caused by the degradation of fan performance. On the other hand, for the fan s with higher than 60% efficiency, the main cause of flowrate reduction might be too much pressure losses due to clogging of filter bags. The degradation of fans usually lead the reduction of hood capture efficiency, resulting in the increase of contaminant concentrations in workplace. To keep fans in good status, self inspections should be periodically conducted. This inspection should include the measurements of flowrate and pressures. The most important thing to be performed is the initial test of local exhaust ventilation system because the initial test data should be used to know the level of system degradation.

일부 탈지세척 및 도금공정 국소배기장치의 성능점검과 개선방안 (Performance of Local Exhaust Ventilation Systems of Degreasing and Plating Workplaces)

  • 한돈희
    • 한국산업보건학회지
    • /
    • 제8권2호
    • /
    • pp.178-185
    • /
    • 1998
  • In order to evaluate and improve the performance of local exhaust ventilation systems for two TCE degreasing (A, B) and two electroplating (C, E) and one acid dipping & plating (D) operations located in Kimhae, the performance test was conducted with trace gases and a thermal anemometer (Kanomax 24-6111, Japan). For the inadequately designed systems, the improvement and redesigns in compliance with recommendation by ACGIH was suggested. The results of performance test for each system are as follows; 1. System of Workplace A was generally well-designed. Actual exhaust air flow rate was in excess of 68% above the recommended standard exhaust air flow rate. 2. System of Workplace B was very well-designed and completely enclosed. 3. All systems of Workplace C including hoods were poorly-designed and actual exhaust air flow rates were insufficient for open tanks. All systems should be upgraded according to ACGIH recommendations. 4. Supply and exhaust air flow rate of push-pull exhaust systems in Workplace D should be greatly increased. The width of flange of dipping tank hood should be increased with the value suggested. 5. System of Workplace E was well-designed. Actual exhaust air flow rate was in excess of 54% above the required.

  • PDF

임펠러-볼류트 유동간섭이 원심형 터보기계의 성능에 미치는 영향에 관한 수치해석적 연구 (Numerical simulation of impeller-volute interaction on a centrifugal turbomachinery)

  • 이재두;주원구
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.170-178
    • /
    • 1999
  • In general, an impeller of centrifugal turbomachinery is designed at isolated condition without considering the presence of a volute, but when the impeller is operating with its volute, the performance of impeller can be different. This is largely caused by the interaction between the impeller and volute flow fields. The magnitude of distortion is increased as the operating point is away from the design point and, as a result, the interaction between the impeller and volute is stronger. In the present calculation, the flow through the impeller is simulated using coarse grids. The flow within the impeller and the volute is naturally unsteady, but the flow is assumed to be steady across the interface between the volute and impeller flow fields. Under the assumption of steady three-dimensional incompressible turbulent flow, the time averaged N-S equations involving standard k-$\epsilon$ turbulent model was solved by the F.V.M. The calculation results are compared with the experimental results obtained for an industrial fan by Sakai etc. and the Hood agreement is demonstrated. And the effects of the impeller-volute interaction are studied.

  • PDF