• Title/Summary/Keyword: Industrial facility

Search Result 1,122, Processing Time 0.033 seconds

Concentration level of Volitile Organic Compounds about the Air of Source Boundary Site in Seongseo Industrial Complex (대구성서산업단지 발생원부지경계 대기 중 휘발성유기화합물질의 농도수준)

  • An Sang-Young;Choi Sung-Woo
    • Journal of Environmental Science International
    • /
    • v.14 no.1
    • /
    • pp.53-60
    • /
    • 2005
  • The concentrations of volatile organic compounds(VOCs) in the ambient air were measured at various point(Source, source boundary) in Seongseo industrial complex during May to November 2003. Air samples were collected in Silcocan canister $(1{\ell},\;6{\ell})$ and analyzed using a cryogenic preconcentration system and GC/MSD. We identified 37 species by the US EPA(TO-14 method). The result showed a variety distribution of the con­centration, Higher concentrations of BTX, Styrene, 1,3,5-Trimethylbenzene, 1,2,4-Trimethylbenzene were observed at the sampling sites. They seemed to be emitted from the facility of wastewater treatment, reaction tank of chemistry factory and facility of Tenter. The concentrations of VOCs contents in Seongseo industrial complex were generally higher than those in Yeosu complex and Ulsan complex, although those were similar in Sihwa­Banwol complex.

APPROXIMATE ANALYSIS OF M/M/c RETRIAL QUEUE WITH SERVER VACATIONS

  • SHIN, YANG WOO;MOON, DUG HEE
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.19 no.4
    • /
    • pp.443-457
    • /
    • 2015
  • We consider the M/M/c/c queues in which the customers blocked to enter the service facility retry after a random amount of time and some of idle servers can leave the vacation. The vacation time and retrial time are assumed to be of phase type distribution. Approximation formulae for the distribution of the number of customers in service facility and the mean number of customers in orbit are presented. We provide an approximation for M/M/c/c queue with general retrial time and general vacation time by approximating the general distribution with phase type distribution. Some numerical results are presented.

Cost-Benefit Analysis by Resource Recovery Facility for Municipal Waste -Focus on Gangwon Province- (생활폐기물 자원화시설의 편익분석 -강원도 중심으로-)

  • Han, Young-Han;Lee, Hae-Seung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.6
    • /
    • pp.2833-2845
    • /
    • 2012
  • In this study, the amount of waste resource that could be recovered was analyzed. The installation and operation costs of waste resource recovery for both single- and multi-regional facility were calculated, and compared with the costs of landfill to investigate the feasibility of them. RDF(Refuse Derived Fuel) process and resource recovery by incineration process were considered as waste resource recovery facility. And, the multi-regions for cost analysis were established on the basis of the proper generation rate of municipal waste with the consideration of combustible ratio. The study results showed that single region facility for both RDF and incineration process has no economic benefit, compared with the landfill method. For the multi-regional facility, RDF process could save a large cost than the landfill method, but the incineration facility couldn't. Separate from the economic benefits, the waste resource recovery should be importantly considered when considering the depletion of fossil fuel, global warming, environmental toxicity, and the enormous expenses due to social conflict and confuse. When the CDM(Clean Development Mechanism) is vitalized in the near future, the additional economic benefits by CERs(Certified Emission Reductions) could be expected. CERs for RDF facility is corresponding to about 256.5 billion won, and CERs for incineration facility is corresponding to about 54 and 77.4 billion won for single- and multi-regional facility, respectively.

A Study on the Improvement of Industrial Safety Education and Ttaining Regulation (사업장의 안전직무교육제도 개선 방안에 관한 연구)

  • 김병석;송수정;강경식
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.20 no.41
    • /
    • pp.87-93
    • /
    • 1997
  • The purpose of this study is to improve the industrial safety education and training act based on comparing industrial safety and health act with facility safety act, construction safety regulation. The new industrial safety and health act is proposed by deleting inefficient education and training regulation which is double checked act by different organization of the government.

  • PDF

Investigation on Economical Feasibility for Energy Business of Waste Water Sludge Discharged in 'A' Industrial Complex (A-산업단지 발생 슬러지의 에너지화를 위한 경제성 검토)

  • Byun, Jung-Joo;Lee, Kang-Soo;Phae, Chae-Gun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.20 no.4
    • /
    • pp.61-74
    • /
    • 2012
  • Industrial complexes in Korea have been vigorously established by economic development plan and development policy of industry in 1960s. Recently, Korean government has promoted Eco Industrial Park (EIP) project to recycle by-products and wastes in industrial park In this study, we analyzed the physical and chemical properties for the sludges discharged from A industrial complex. And we investigated the economic feasibility and environmental impact of sludge to energy facilities. The analysis results indicated that the petrochemical industry were 92% in sludge production, the highest treatment amount was landfill, followed by incineration and recycling and then ocean disposal. Wastewater sludge and process sludge samples are collected and analyzed to use as basic data on economic feasibility and environmental impact. Weighted average heating value of sludge samples was 3,891kcal/kg. Based on this data, installation and operation costs, operation returns of operating the drying facility are estimated, compared with cogeneration facility. And this study examines how the payback period of each simulation(total 8 case) with the important parameter changes. As a result, it was found that what needs the shortest payback period is 3years with connection of drying facility and cogeneration facility based on the government's financial subsidy system.

A Study on the Water Pollutant Discharge Inventories for the Improvement of Industrial Wastewater Management System: Primary Steel Manufacturing Facility and Petroleum Refining Products Manufacturing Facility (산업폐수 관리체계 개선을 위한 수질오염물질 배출목록 구축에 대한 연구: 1차 철강 제조업과 석유정제품 제조업)

  • Ahn, Taeung;Kim, Dongmin;Son, Daehee;Kim, Jaehoon
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.5
    • /
    • pp.453-467
    • /
    • 2020
  • This study aimed to inventory the water pollutant discharge of wastewater from two facilities, one primary steel manufacturing facility and one petroleum refinery, both of which are located in Korea, and to identify ways to improve the wastewater treatment process through field investigation. Probability evaluation was used to inventory the substances in polluted water. The samples collected in this study included original wastewater, on processing wastewater, and treated water. The general description of wastewater occurrence, major sources, and treatment facilities were also investigated to obtain an integrated database of the pollutants created by different industrial categories. Based on our analysis of raw wastewater and final effluent, the detected pollutants were confirmed by analyzing their presence in the raw or supplemental materials, the potential of formation as byproducts, and the possibility of inclusion as impurities. The compounds detected for each category were screened via investigation of their possible sources and confirmed as the final water pollutant inventories. Thirty kinds of water pollutants were emitted by the primary steel manufacturing facility (reference in case A), including 14 specified hazardous water pollutants. The petroleum refinery (reference in case B) emitted 36 water pollutants, including 16 specified hazardous water pollutants.

Study of Reliability Analysis Based Power Generation Facilities Maintenance System - Focused on Continuous Ship Unloader - (신뢰성 분석 기반 발전설비 점검계획 수립 시스템 연구- 석탄 하역기를 중심으로 -)

  • Hwang Seong Hwan;Kim Yu Rim;Kang Sung Woo
    • Journal of Korean Society for Quality Management
    • /
    • v.51 no.2
    • /
    • pp.315-327
    • /
    • 2023
  • Purpose: Recently, research has continued to predict the time of failure of the facility through measurement data obtained by attaching a sensor to the facility. However, depending on the facility, it may be difficult to attach a sensor. The purpose of this study is to propose a power generation maintenance plan system based on failure record data obtained from Continuous Ship Unloader, one of the facilities that is difficult to attach sensors. Methods: This study uses data collected from 2012 to 2022 from the 'CSU-1B' model among Continuous Ship Unloader operated by Korea Midland Power Co., LTD. By fitting fault record data to the Weibull distribution, appropriate maintenance cycles and ranges for each target facility subsystem are derived. In addition, maintenance group between subsystems is selected through Euclidean distance, a metric often used for time series data similarity. Through this, a system for establishing an maintenance plan for power generation facilities is proposed. Results: The results of this study are as follows. For the 17 subsystems of the Continuous Ship Unloader, proper maintenance cycles and ranges were determined, and a total of four maintenance groups were chosen. This resulted in the creation of an power generation maintenance plan system and the establishment of an maintenance plan. Conclusion: This study is a case study of power generation facilities. We proposed a maintenance plan system for Continuous Ship Unloader among power generation facilities.

Two-Phase Genetic Algorithm for Solving the Paired Single Row Facility Layout Problem

  • Parwananta, Hutama;Maghfiroh, Meilinda F.N.;Yu, Vincent F.
    • Industrial Engineering and Management Systems
    • /
    • v.12 no.3
    • /
    • pp.181-189
    • /
    • 2013
  • This paper proposes a two-phase genetic algorithm (GA) to solve the problem of obtaining an optimum configuration of a paired single row assembly line. We pair two single-row assembly lines due to the shared usage of several workstations, thus obtaining an optimum configuration by considering the material flow of the two rows simultaneously. The problem deals with assigning workstations to a sequence and selecting the best arrangement by looking at the length and width for each workstation. This can be considered as an enhancement of the single row facility layout problem (SRFLP), or the so-called paired SRFLP (PSRFLP). The objective of this PSRFLP is to find an optimal configuration that seeks to minimize the distance traveled by the material handler and even the use of the material handler itself if this is possible. Real-world applications of such a problem can be found for apparel, shoe, and other manual assembly lines. This research produces the schematic representation solution using the heuristic approach. The crossover and mutation will be utilized using the schematic representation solution to obtain the neighborhood solutions. The first phase of the GA result is recorded to get the best pair. Based on these best matched pairs, the second-phase GA can commence.

The Ivestigation and Estimate of Influence on Air Quality by the Exhaust of Air Pollutant from Facility of the District Heating Located in Small City (중소도시에 위치한 집단 열 공급시설에서 배출되는 대기오염물에 의한 주변 대기질의 영향 조사 및 예측)

  • Yeon, Ik-Jun;Kim, Kwang-Yul
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.3 s.49
    • /
    • pp.1-10
    • /
    • 2003
  • This study was aimed to investigate the influence on the vicinity by air pollutant generated from facility of the district heating located in local small town. We selected the seven areas arround the surroundings of facility of the district heating, compared the air quality evaluated before and after operations of the facility, and estimated the diffusion of air pollutant exhausted from the facility using a ISC model. The result was that the concentration of TSP before and after operations of the facility was 89${\sim}$94${\mu}$g/m$^3$,and 72${\sim}$81${\mu}$g/m$^3$, respectively and the latter showed a decline in concentration. Also, there was no relationship between straight distance from the facility of the district heating and the concentration of TSP. This result was applicable to cases of PM-10 and SO$_2$. We also investigated the influence on the air around the neighbored area by air pollutant produced from facility of the district heating using ISCLT3 model. The adding-concentrations of TSP, SO$_2$,NO$_2$, and CO were 0.0019${\sim}$0.00183${\mu}$g/m$^3$, 0.0029${\sim}$0.5648ppb, 0.2924${\sim}$l.9837ppb,and 0.0087${\sim}$0.0590ppb, respectively. It is predicted that each concentration is added to pollutant exhausted from facility of the district heating and is about 1/100${\sim}$1/180,000 of present air quality. This has a tiny influence on general air quality. According to this analysis, the concentration of air pollutant is less effected to pollutants expected by the facility of the district heating than other pollutants emitted from mobil source or industrial complex, and etc.

A Study on Management Body Consciousness for Managing Facility Safety Inspection and Diagnosis (시설물 안전 점검 및 진단 실시에 대한 관리주체 의식에 관한 연구)

  • Kim, Hak-Eung;Jung, Soo-Il
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.3
    • /
    • pp.19-27
    • /
    • 2008
  • Since 1995, the facility of class 1 and 2, classified by law had been subject to system of post maintenance management where periodic safety inspection and diagnosis to identify any problems and to take appropriate measures as a matter of urgency. Although the standards and systems had been revised many times for continuous improvement due to surrounding environmental factors, the technical factors and other factors for improvements, continuous researches and efforts are needed to ensure even higher effectiveness. Furthermore, the consciousness of the management body that executes and implements such improvements for facility management is most important. Therefore in this study, through such analysis, more realistic management consciousness review was performed. Also the direction for improvements is proposed, to carry out more effective facility safety management systems implementation.