• Title/Summary/Keyword: Industrial control system

Search Result 4,152, Processing Time 0.031 seconds

The Effects of Pollutants into Sub-basin on the Water Quality and Loading of Receiving Streams (하천 수질 및 부하량에 미치는 유역 내 오염원의 영향)

  • Han, Mideok;Son, Jeeyoung;Ryu, Jichul;Ahn, Kihong;Kim, Yongseok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.9
    • /
    • pp.648-658
    • /
    • 2014
  • We examined the effects of pollutants into sub-basin on the water quality and loading based on data surveyed during January-December 2013 from 13 sites of 5 streams in the Jinwi watershed. We used the contour plot and Kruskal-Wallis rank sum test to analyze seasonal variation of water quality and loading and Pearson correlation analysis to assess the relationships between pollutants and loadings. The significantly higher seasonal variation were SS, TN and TOC as compared to other water quality constituents (P < 0.001). A significant interaction existed between the effects of human population and the effects of discharge of Sewage Treatment Plant (STP) on water quality and loading, especially for the spring and winter seasons. It is necessary to control discharge water of sewage and wastewater from industrial facilities and to make full use of the watershed management system such as TMDLs in operation since 2012 for improvement in stream water quality.

Evaluation of Washing Efficiency of Collective PM by Electrostatic Precipitator in Subway Station Using Nano Bubble (나노버블을 이용한 지하철용 전기집진기 포집먼지에 대한 세척효율 평가)

  • Lee, Hyung-Don;Lee, Seung-Hwan;Park, Chan-gyu
    • Clean Technology
    • /
    • v.26 no.1
    • /
    • pp.13-21
    • /
    • 2020
  • Air pollutants in a subway are complexly caused by outdoor factors such as ventilating opening and indoor factors such as the movement of passengers on the subway. According to recent research results, most of the air pollutants generated in subway tunnels and stations are caused by indoor variables such as train movement. To control air pollutants such as particulate matter (PM), a prevention facility such as the electrostatic precipitator (EP) or bag filter collector was required in a subway station. In particular, the PM removed by the EP must be kept clean continuously to manage PM effectively. Therefore, a nano-bubbling washing system was developed in this study to clean a contaminated collecting plate in an EP at the main subway tunnel in Seoul. Removal efficiency compared with normal water and nano-bubbling water was likewise studied. As a result, the washing efficiency of collective PM increased in accordance with the increasing of injection pressure, with nano bubbling washing being 130.8% higher than tap water. According to increase in washing times, the maximum washing efficiency was 143.1% higher than tap water, but suitable washing times were less than 3 times. According to the results of the washing efficiency by variation of residence time, it was confirmed that the maximum residence time of nano-bubble water was maintained within 5 minutes.

A Case Study of Calculating Flood Inundation Area by HEC-GeoRAS (HEC-GeoRAS 모형에 의한 침수면적산정 사례연구)

  • Kim, Chang-Soo;Lee, Young-Dai;Lee, Hwan-Woo
    • Journal of Korean Society of societal Security
    • /
    • v.2 no.4
    • /
    • pp.43-48
    • /
    • 2009
  • During the past few years, Korea has experienced extraordinary floods, which have caused many damages of lives and properties. Flooding caused by typhoon is the most common disastrous phenomenon of nature among all catastrophes. As the average temperature of the earth has been increasing by global warming, the possibility of typhoon is also increased by abnormal climate changes. Along with the river improvement as a part of flood control, the time of concentration has been decreased, so the pick discharge has been increased. Moreover, with the land development activities, the area of storage has been diminishing, and the damages from inundation have been continuously increasing. There were a lot of damages to farmland in 1960's, industrial and public facilities in 1970's, and a lot of sufferings from the windstorm in 1980's. In 1990's, however, the amount of damages was increased substantially. So, there is need to decrease the number of the victims and loss of properties by applying preventive measures against natural calamities. This study has employed a simulation system to calculate the depth and amounts of inundation areas to forecast and prevent from flood damage by using rainfall-runoff model. In this study, a case study method is adopted to show inundation by using rainfall-runoff model, HEC-GeoRAS and Arcview. It is hoped that, this study would be conducive to professionals and organizations working in the field of disaster management.

  • PDF

A Study on Evaluation of LED Lighting Environments for Energy Saving and Work Effectiveness (에너지 저감과 업무 효율성을 위한 LED 조명환경 평가에 대한 연구)

  • Kim, Hyung-Sun;Lim, Jae-Hyun;Lee, Kee-Sun;Kim, Kil-Hee;Jung, Hee-Chang;Kim, Jin Ho
    • Science of Emotion and Sensibility
    • /
    • v.18 no.2
    • /
    • pp.45-54
    • /
    • 2015
  • This study carried out an experiment to identify subject's work effectiveness and energy saving effect using LED light. Towards this end, this study configured nine various lighting environments in order to control PWM (Pulse Width Modulation) and illuminance (lux), which are the characteristics of LED light. The PWM ratio of LED light was set as R:G:B=1:1:1, R:G:B=4:1:5, and R:G:B=8:7:7, respectively, and illuminance (lux) was set as 400 lx, 700 lx, and 1000 lx, respectively. In addition, the indoor environment was set temperature $20-24^{\circ}C$, humidity 50%-60%, and the amount of clothing 1. This study analyzed work effectiveness and energy consumption in nine lighting environments, each. Error correction was performed for work effectiveness analysis, and cumulative power consumption was measured in each lighting environment for energy consumption analysis. According to experiment results through the lighting environments suggested in this study, accuracy and spent time effectiveness were good in 700lux and higher than 400lux. For spent time, the best effectiveness was revealed in the suggested PWM ratio, R:G:B=8:7:7. The lowest power consumption on each illuminance (lux) was revealed in the order of R:G:B=8:7:7, RGB=1:1:1, and R:G:B=4:1:5. Therefore, pulse-width modulation effect is proposed in this paper was found to affect the efficiency and energy saving.

Heat Storage Material by Using Phase Change Materials to Control Buildings Thermal Environment Characteristics (건축물 열환경 특성제어를 위한 상변화 축열재)

  • Yun, Huy-Kwan;Han, Seong-Kuk;Shim, Myeong-Jin;Ahn, Dae-Hyun;Lee, Woong-Mok;Park, Jong-Soon;Kim, Jae-Yong
    • Applied Chemistry for Engineering
    • /
    • v.21 no.5
    • /
    • pp.522-526
    • /
    • 2010
  • Heat storage application techniques can be categorized into the sensible heat storage and the latent heat storage according to the method of heat storage. Heat storage is the way of saving remaining heat when heating and cooling loads are light, and then using it when the heating and cooling loads are heavy. Latent heat storage is defined as the method of saving heat by using substances which have high potential heat when phase change is in the range of a certain temperature and when heat storage space is small, compared to those of sensible heat storage and it is possible that absorption and emission of heat at a certain temperature. This study is conducted to save energy when either air-conditioning or heating is operated in a building. We have tried to find out the essential properties of matter and the optimum mixing rate about cement and gypsum for building materials, which have been widely used for proper phase change materials (PCM), when thermal environment property is applied. So we obtained the result of the cooling delay effect about 19% with heat storage mortar containing 3 wt% of PCM.

Physicochemical and Microbial Characteristics of Oiji Prepared with Dry Salting Methods during Low Temperature Storage (저염 건식절임법으로 제조한 오이지의 저온저장 중 이화학적$\cdot$미생물학적 품질특성)

  • Kwon Oh-Yun;Yang Yun-Hyoung;Park Wan Soo;Kim Mee Ree
    • Korean journal of food and cookery science
    • /
    • v.21 no.4 s.88
    • /
    • pp.545-555
    • /
    • 2005
  • The physicochemical and microbial characteristics of Oiji prepared with dry salting method, which has been used industrially for industry, were investigated. Low salting and low storage temperature were employed:extremely low salting extremely low temperature; ESET $(5\%,\;0^{\circ}C)$, very low salting extremely low temperature;VSET $(10\%,\;0^{\circ}C)$, extremely low salting very low temperature; ESVT$(5\%,\;5^{\circ}C)$, low salting very low temperature; VSVT$(10\%,\;5^{\circ}C)$ and high salting low temperature;HSLT$(30\%,\;10^{\circ}C)$ for control. Acidity was lower, and pH was higher in VSET, in of which the fermentation pattern was similar with that of HSLT The time required to reach the optimum acidity ($0.3\%$ lactic acid) was longer delayed for VSET (168 days), than for compared to ESVT (51 days). During storage of Oiji, greenness (-a) as measured with of the Hunter color system wasshowed the highest in VSET, and the lowest while in ESVT, the lowest. Total microbial and lactic acid bacteria counts number were the lowest in HSLT and VSET and were the lowest than in other groups, while the highest in ESVT. Yeast was not detected in HSLT, but was the highest while in VSVT. E coli coliform and listeria were detected in the $5\%$ salting groups, although Salmonella was not detected in any of the all groups. Texture profile analysis demonstrated exhibited that fracturability and hardness were highest in HSLT and VSET, compared to the other groups. Scores of over-all preference for ESVT and HSLT were higher atwith 6.3 and 6.2, respectively, compared to the other products. Based on these results, lower saltiness less than $10\%$ and lower storage temperature (less than $5^{\circ}C$) condition was optimum for maximizing the better for good quality of industrial Oiji preparation in industry.

Effects of Sewage Treatment on Characteristics of Sludge as a Composting Material (하수처리가 퇴비화를 위한 하수 슬러지 특성에 미치는 영향)

  • Kim, Jae-Koo;Kim, Jong-Soo
    • Applied Biological Chemistry
    • /
    • v.41 no.2
    • /
    • pp.181-186
    • /
    • 1998
  • The effects of sewage treatment on characteristics of sludge as a composting material were investigated for a year during the initial operation at the full-scale Chunan sewage treatment plant. Due to the shortage of design capacity of belt press, a sludge dewatering unit, non-volatile solids were recirculating and concentrating in the treatment plant, resulting in an increase of MLSS and a decrease in F/M ratio at the activated sludge system. Special attention is required for long term operations since the increase of non-volatile solids in the plant would deteriorates the treatment efficiency. The sewage sludge of the Chunan sewage treatment plant showed 79.5% of water content, 11.6% of organic content, and C/N ratio of 6.1, and contained As 1.8 mg/kg, Cd 27 mg/kg, Hg <0.1 mg/kg, Pb 54 mg/kg, T-Cr 370 mg/kg, and Cu 1,100mg/kg of heavy metals. In order to be used as raw material for optimum composting, the sewage sludge requires bulking agents for moistrure/porosity control and a carbon source for adjusting C/N ratio. However, the sewage sludge is not adequate as a soil conditioner after composing due to a high content of heavy metals. If the sewage sludge has to he used as a soil conditioner after composting, it as required to identify and remove tire industrial wastewater portions in tire influent of the plant since heavy metals in the influent were mostly concentrated in dewatered sludge.

  • PDF

Occupational Dermatoses by Type of Work in Greece

  • Zorba, Eleni;Karpouzis, Antony;Zorbas, Alexandros;Bazas, Theodore;Zorbas, Sam;Alexopoulos, Elias;Zorbas, Ilias;Kouskoukis, Konstantinos;Konstandinidis, Theodoros
    • Safety and Health at Work
    • /
    • v.4 no.3
    • /
    • pp.142-148
    • /
    • 2013
  • Background: To elucidate the relationship between seven occupational dermatoses (ODs) and 20 types of work in Greece. Methods: This was a prevalence epidemiologic study of certain ODs among 4,000 workers employed in 20 types of enterprise, in 104 companies, in 2006-2012, using data from company medical records, questionnaires, occupational medical, and special examinations. The ${\chi}^2$ test was applied to reveal statistically significant relationships between types of enterprises and occurrence of ODs. Results: A high percentage (39.9%) of employees included in the study population suffered from ODs. The highest prevalence rates were noted among hairdressers (of contact dermatitis: 30%), cooks (of contact dermatitis: 29.5%), bitumen workers (of acne: 23.5%), car industry workers (of mechanical injury: 15%), construction workers (of contact urticaria: 29.5%), industrial cleaning workers (of chemical burns: 13%), and farmers (of malignant tumors: 5.5%).We observed several statistical significant correlations between ODs (acute and chronic contact dermatitis, urticaria, mechanical injury, acne, burns, skin cancer) and certain types of enterprises. There was no statistically significant correlation between gender and prevalence of ODs, except for dermatoses caused by mechanical injuries afflicting mainly men [${\chi}^2(1)=13.40$, p < 0.001] and for chronic contact dermatitis [${\chi}^2(1)=5.53$, p=0.019] afflicting mainly women. Conclusion: Prevalence of ODs is high in Greece, contrary to all official reports by the Greek National Institute of Health. There is a need to introduce a nationwide voluntary surveillance system for reporting ODs and to enhance skin protection measures at work.

(A) Study on the Structure Change of Financial Industrial for strengthening Global Financial Control (글로벌 금융 규제 강화에 따른 금융산업의 구조변화에 대한 연구)

  • Ham, Hyung-Bum;Choi, Chang-Youl
    • International Commerce and Information Review
    • /
    • v.16 no.2
    • /
    • pp.47-67
    • /
    • 2014
  • Since the global financial crisis, criticism against the integrity of financial institutions proposed new financial regulations such as Basel III. These systems are expected to have impacts multilaterally on management and structure of mid- and long-term financial industry. It is also believed that financial institutions will inevitably review business model to respond to these enhanced regulations. The ongoing global financial regulation pursues regulation scope extension, introduction of global regulatory capital system, introduction of global liquidity, etc. As for quantitative index, Basel Committee on Banking Supervision is promoting QIS which is discussed mainly on implementation time from the juridical point of view. This study aims to present domestic banking industry's structural changes depending on regulation enhancement of foreign countries after global financial crisis, and suggest strategy that improves competitiveness of products. Looking at the research result, global financial regulation requires compliance with the regulations through treaties but it shows negative time center around banks. Furthermore, it is also pointed out financially advanced countries' passive attitude on regulation enhancement is problem. Therefore, regulations differentiated between developing and developed countries, dualistic regulations on financial industry, participation of advanced nations, etc are the postulation to change the structure of financial industry.

  • PDF

Field Scale Study for Energy Efficiency Improvement of Crematory System by the Shape Optimization of Combustion Chamber (화장로 형상 최적화를 통한 에너지효율개선을 위한 실증연구)

  • Won, Yong-Tae;Lee, Seung-Mok
    • Applied Chemistry for Engineering
    • /
    • v.30 no.5
    • /
    • pp.546-555
    • /
    • 2019
  • The purpose of this study was to improve the performance of the bogie-type crematory, which is the mainstream of domestic crematory equipment. A field scale technology was investigated via increasing the volume by changing the shape of the furnace and reducing the cremation time and saving the energy usage through the optimization of burner combustion control. First, the optimized structural design through thermal flow analysis increases the volume of the main combustion chamber by about 70%, which increases the residence time of the combustion flue gas. A designed pilot crematory was then installed and the combustion behavior was tested under various operating conditions and the optimum operating plan was derived from for each furnace shape. Based on the results, the practically applicable crematory was designed and installed at Y crematorium in the P City. Optimal combustion conditions could be derived through operating the demonstration crematory furnace. The crematory time and fuel consumption could be minimized by increasing the energy efficiency by increasing the residence time of high temperature combustion flue gas. In other words, the crematory time and fuel consumption were 38 min and $21.8Nm^3$, respectively which were shortened by 44.1 and 54.4% lower than that of the existing crematory, respectively.