• Title/Summary/Keyword: Industrial Waste Water

Search Result 454, Processing Time 0.023 seconds

Curtailment of Water use Through the Integration of Process Waste Waters at the Standard Thermal Power Plant (표준화력발전소의 발전폐수 통합을 이용한 용수 사용량 절감)

  • Mun, Gyeong-Seok;Jang, Heui-Su
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.3
    • /
    • pp.437-443
    • /
    • 2006
  • The Water usage is relationship which is close with the administrative cost from industrial facility. It is not easy to reduce a water usage. This research is the optimization of the waste water quantity which process waste water integration of the standard thermal power plant in system operate time. The turbine rotates by force of the steam and it produces an electricity. Demineralization Water is manufacture purity manufacturing equipment and it is supplied in power plant channel. We knew a possibility of reducing from pure control process. When it is reduced the Back Washing time, Rinsing time of the gravity filter and the activated carbon filter. Also, It is possible even from regeneration phase in Condensate Polishing Demineralization System. In addition, There is also the water which the drain of the sampling water for watching the condition of power plant process will be able to use. Integrates these processes it will be able to reduce an annual 30,000 ton degree. The research is want to use the fundamental data for the water curtailment of the power plant.

Comparison of the unit mass discharge from wastewater treatment facility in the industrial park with the estimation methods (산업단지 폐수발생량 원단위 산정 비교연구)

  • Kim, Joon-Yup;Choi, Kyoung-Sik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.3
    • /
    • pp.339-344
    • /
    • 2014
  • The predictive capacity of wastewater treatment facility in the industrial park was estimated by the traditional method and on-the-spot survey such as certification of wastewater report and the invoices of water supply and ground water supply. The ratios of a converted wastewater to supplied industrial water between traditional method and on-the-spot survey in the estimation methods were different. By using traditional method, the business type of clothes, accessary and fur production had 77.18 % of waste ratio of wastewater and $10.72m^3/day{\cdot}1000m^2$ unit mass of wastewater as the highest among 9 business types. With the respect to the on-the-spot survey, food manufacturing business type had 75 % of waste ratio of wastewater and $8.35m^3/day{\cdot}1000m^2$ unit mass of wastewater as the highest values. The amount of wastewater from on-the-spot survey method was 541 $m^3/day$ less than one from traditional method.

High Voltage Nano-Pulse Generator for Industrial Waste Water Treatment (폐수 처리용 고전압 나노 펄스 발생기)

  • Jang, Sung-Duck;Son, Yoon-Gyu;Oh, Jong-Seok;Kwon, O-Jung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.4 no.3
    • /
    • pp.311-318
    • /
    • 2001
  • The application of a pulsed power system is being extended to a environmental and industrial fields. The non-dissolution waste water pollutants from industrial plants can be processed by applying high voltage pulses with a fast rising time (a few nanoseconds) and short duration (nano to microseconds) in a pulsed corona discharge reactor. The nano-pulse generator with a magnetic switch has been developed. Its corona current in load can be adjusted by pulse width and repetition rate. we investigated the performance of the nano-pulse generator using the dummy load which is composed of resistor and capacitor equivalent to the actual reactor. This paper descibes the electrical characteristics of the nano-pulse generator that produces a 300 ns pulse at maximum repetition rate of 400 pps with a voltage of 40 kV across a $640{\Omega}$ load. In this paper we briefly discuss a configuration of system and test results.

  • PDF

Advanced Biological Treatment of Industrial Wastewater using Food Waste Leachate as an External Carbon Source: Full-Scale Experiment (음식물쓰레기 탈리액을 이용한 산업폐수의 생물학적 고도처리 실증실험)

  • Lee, Byeongcheol;Ahn, Johwan;Lee, Junghun;Bae, Wookeun
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.4
    • /
    • pp.461-466
    • /
    • 2011
  • The feasibility of utilizing food waste leachate as an external carbon source was tested to enhance biological nutrient removal from an industrial wastewater with an average flow rate of $164,800m^3/d$ and a low carbon/nitrogen ratio of 2.8. A considerable improvement in the removal of nitrogen and phosphorus was observed when a certain amount of the leachate, ranging from 70 to $142m^3/d$, was supplemented to the biological industrial wastewater treatment process. The addition of the leachate led to an increase in the BOD/N ratio (4.5) and the removal efficiency of nutritents from 29.7% to 71.7% for nitrogen and from 34.8% to 65.6% for phosphorus. However, an excessive dose of the leachate that significantly exceeded $120m^3/d$ caused serious operational problems, like oil-layer formation in the grit chamber and scum layer in the primary clarifier. Thus, an supplement of food waste leachate at a dose acceptable to an existing facilities can be a practical and effective means to enhance the nutrient removal from industrial wastewater and to dispose of the food waste leachate.

Waste Reduction Always Pays

  • Lee, B.M.
    • Applied Chemistry for Engineering
    • /
    • v.3 no.2
    • /
    • pp.194-200
    • /
    • 1992
  • Dow has made waste reduction a priority at its facilites around the world. In 1986, the company formalized its waste reduction under a program called WRAP-Waste Reduction Alwasy Pays. The objectives of WRAP are to seek out cost effective projects that reduce waste to the environment, measure and track performance, and recognize employee excellence. The successful examples of Dow's WRAP Program are introduced as follows : 1. By-Product Feedstock Optimization. 2. Plastics Reclamation. 3. Glucol II Plant Absorber Water Upgradele. 4. Loss Reduction Project.

  • PDF

APPLICATION OF TUBULAR MEMBRANE FILTRATION TO LNDUSTRIAL WASTE WATER TRATMENT (산업폐수에 관형막 분리응용)

  • 지은상
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1991.10a
    • /
    • pp.58-63
    • /
    • 1991
  • Membrane technology has been effectively used for many years in certain segments of industrial water treatment. Recent advances in combining sophisticated chemical pre-treatment technology with cross-flow membrane filtration technology have successfully demonstrated that highly efficient, low-cost methods for treating a large of industral streams are available.

  • PDF

Progresses in membrane and advanced oxidation processes for water treatment

  • Khulbe, K.C.;Feng, C.Y.;Matsuura, T.;Ismail, A.F.
    • Membrane and Water Treatment
    • /
    • v.3 no.3
    • /
    • pp.181-200
    • /
    • 2012
  • At present water crisis is not an issue of scarcity, but of access. There is a growing recognition of the need for increased access to clean water (drinkable, agricultural, industrial use). An encouraging number of innovative technologies, systems, components, processes are emerging for water-treatment, including new filtration and disinfectant technologies, and removal of organics from water. In the past decade many methods have been developed. The most important membrane-based water technologies include reverse osmosis (RO), ultrafiltration (UF), microfiltration (MF), and nanofiltration. Beside membrane based water-treatment processes, other techniques such as advanced oxidation process (AOP) have also been developed. Some unconventional water treatment technology such as magnetic treatment is also being developed.

A Study on the Adsorption of Heavy Metals in Waste Water using Domestic Clays (검토를 이용한 폐수 중 중금속 흡착에 관한 연구)

  • Bae, Jang-Soon;Park, Chan-Kyo;Sung, Ki-Chun;Lee, Seok-Woo;Hwang, Yong-Hyun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.124-131
    • /
    • 2004
  • The adsorption of heavy metals in the waste water carried out on the various domestic clays and waste pottery. The effect of parameters such as pH, temperature, adsorption time and coexisting cations on the adsorption ability and characteristics were investigated to find out whether the clays could be used as adsorbents. Adsorption equilibrium was reached within 20 minutes on all the clays. The optimum pH was found to be above 5. When other cations such as Cu(II) or Zn(II) coexisted with Pb(II), the adsorption amount of Pb(II) decreased because of competing adsorption.

Preparatory Monitoring of Trace Chemicals Load into Nakdong River (낙동강 상수원에 부하되는 미량유해화학물질의 사전 모니터링)

  • Kang, Mee-A;Jo, Soo-Hyun;Jeong, Gyo-Cheol;Lee, Seung-Hwan;Kim, Sun-Il
    • The Journal of Engineering Geology
    • /
    • v.16 no.4 s.50
    • /
    • pp.351-357
    • /
    • 2006
  • Recently there is increasing the flow of hazardous chemical substances caused by industrial waste waters into a main river. It is needed to make the high treatment in drinking water treatment plants for reducing a health risk. Therefore, the monitoring of trace hazardous chemical substances by the industrial waste water inflow is available increasing economical efficiency of river management as well as reduction of risk. In this study, the most important substance among numerical and quantitative trace hazardous chemicals is Hexachlorobutadiene in an effluent of industrial wastes. However all items of GroupII which was included with semiconductor, electricity/electron and metal assemble was not detected. It means that we must consider the characteristics and behavior of load pollutants to water resources to select monitoring items. That was called 'preparatory monitoring'. We can reduce an economical consumption as well as risks from these pollutants using the preparatory monitoring.

Fluoride Contents of River Water and Industrial Waste Water in Seoul (서울市內 河川水 및 工場排水中의 플루오르 含量)

  • Whang, Kyu-Ja
    • Journal of the Korean Chemical Society
    • /
    • v.12 no.4
    • /
    • pp.163-169
    • /
    • 1968
  • The analysis for the fluoride contents of river water and industrial waste water in Seoul area has been carried out by the spectrophotometric method, from February to July, 1968. The results show that the average fluoride contamination is found to be in the range of $0.07{\pm}0.03{\sim}0.29{\pm}0.05$ mg/l. The reason for this contamination is discussed in detail.

  • PDF