• Title/Summary/Keyword: Industrial Technology Leakage

Search Result 187, Processing Time 0.028 seconds

Research Regard to Necessity of Smart Water Management Based on IoT Technology (IoT 기술을 활용한 스마트 물관리 필요성에 관한 연구)

  • Choi, Young Hwan;Kim, Yeong Real
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.22 no.4
    • /
    • pp.11-18
    • /
    • 2017
  • The Objective of this Study is to Prove the Effectiveness of a Smart Water Management(SWM) Technology. The SWM Technology can Reduce the Production Cost using Internet of Thing(IoT) Technology that Utilizes Remote Metering of Consumer's Water usage and Reduce the Leakage of Supply Facilities. The SWM Demonstration Model Installed a Remote Water Leakage Sensor, Smart Metering and Micro Multi Sensor in Water Supply Facility, and Provided Real-Time Monitoring of the Operation Status. Consumers can be Provided the usage of Tap Water and the Water Puality through a Smart Phone Application. At this Time, we Surveyed Whether Consumers save the Tap Water or Drinking Directly using the Tap Water usage Information. Also, this Study is to Verify the Degree of Improvement of Water Supply Rates and Drinking Water Rate, and to Decrease Consumer's Complaints, Operating Costs, and Water Consumption by the SWM Technology. It is also Established a SWM Model Combined with the IoT Sensor at Supply Facilities, operator monitoring system and explored recovery solution detected events. It means the upbringing of the domestic water industry by developing the related technologies and spreading the SWM to advanced levels.

Study on the Establishment of the Act on the Prevention and Protection of Technology Leakage ('기술유출방지 및 보호지원에 관한 법률'제정에 관한 연구)

  • Noh, Jae-Chul;Ko, Zoon-ki
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.7
    • /
    • pp.487-497
    • /
    • 2017
  • South Korea needs reorganization of dispute resolution system due to the frequent occurrence of a case that trade secret or technique are leaked. First, the distributed various laws are established and enforced by enacting and enforcing individual laws. Therefore, the redundancy problems, the collision of individual laws, the decline in diversity, integrity, and connectivity are issues. An independent legal system is needed by Act on the Prevention and Protection of Technology Leakage. Thereby, The support system of technological protection that is sprayed in government departments such as the Small and Medium Business Administration, the Ministry of Trade, Industry and Energy, the Patent Office, the Fair Trade Commission, the Trade Committee, the National Police Agency, and the Spy Agency integrates and unifies institutionally, and it is necessary to advance a policy with functional division. Second, the Patent Tribunal, the Invention Promotion Act, the Industrial Property Right Dispute Mediation Committee by the patent law, the Industrial Technical Dispute Mediation Committee on the Industrial Technology Outflow Prevention and Protection Law and the Medium and Small Firm Dispute Mediation and Arbitration Committee on Small Business Technology Protection Support Law are installed. However, since it established the integrated law on the Act on the Prevention and Protection of Technology Leakage, it is desirable to set the merged operation of establishment on the Technical Dispute Mediation Committee under the Small and Medium Business Administration or the Ministry of Trade, Industry and Energy.

Implementation of Leakage Monitoring System Using ZigBee (ZigBee를 적용한 누전상태 모니터링시스템 구현)

  • Ju, Jae-han;Na, Seung-kwon
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.1
    • /
    • pp.107-112
    • /
    • 2017
  • In recent years, electric shock accidents due to electric leakage currents of household appliances such as computers, TVs, refrigerators, and LED lights are continuously occurring in homes and industrial buildings. And it is not easy to check the leakage current of each household appliances connected in parallel at the rear end of the module. In addition, the leakage current flowing through the path of the normal current other than the existing current leakage circuit breakers are installed in the distribution box, only the function to cut off the power when the leakage. Therefore, there are various disasters such as electric shock and fire caused by short circuit of household appliances, and the risk of such leakage current is seriously presented. In this paper, we propose a method to implement a leakage monitoring system that can be monitored at all times using Zigbee communication based on IEEE 80215.4, which has advantages in low power and low cost among short range wireless communication systems.

The measurement of the half period modulated pulse on earth for detection of a underground electric leakage point (지중선로 누전점 탐지를 위한 반주기 변조된 대지 펄스 측정)

  • Kim, Jae-Hyun;Jeon, Jeong-Chay;Yoo, Jae-Geun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.11
    • /
    • pp.5123-5127
    • /
    • 2011
  • Research and development for the technology, that is about maintenance and accidents prevention of underground power distribution line, are demanding. The precise detection of leakage point of underground power line is very important, because it is difficult to detect the exact location of a fault in underground power line and to repair faults. When earth electric potential is measured to detect underground electric leakage point after transmitting AC electric pulse wave to underground power line, it must be measured in a specific half period of AC pulse wave because the distribution of the electric earth potential varies with the polarity of the transmitted wave. In this paper we proposed the measurement of half period modulated earth potential as a method to detect a underground leakage point. And We compared the proposed method with other methods. Through experiments we verified that the proposed method can be implemented and operated properly.

Process Improvement of Land System Engine for Visualization and Increasing Identification of Engine Oil Leakage (엔진오일 누유 가시화 및 식별력 증대를 위한 기동화력장비 엔진 공정개선)

  • Seo, Suk Ho;Kim, Ji Hoon;Oh, Dae San
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.321-327
    • /
    • 2020
  • Engine oil leaks comprise the largest percentage of the major quality problems that have occurred during the engine production process for military land system equipment over the last two years. To minimize this, it is essential to understand the root cause of the engine oil leakage and perceive the more common leakage area, as well as reduce the quality costs of pre-identification for leaks in the engine assembly process and single items. Therefore, in this study, the mass production quality of engines installed and operated in power equipment was improved by visualizing the engine oil leakage injected with the fluorescent dye and increasing the identification of the engine oil leak phenomenon. For this reason, the possibility of substituting the engine oil was considered and the engine oil was injected with the fluorescent dye. The maintenance was improved by reforming the engine oil injection process and leakage inspection process. Finally, these results suggest that the quality costs between mass production processes can be minimized by ensuring the reliability of military engines by reducing the user's complaints and improving the quality control capabilities of engine manufacturers.

A risk assessment of $CO_2$ geological storage for domestic application (이산화탄소 지중저장의 국내적용을 위한 위해성 평가 방안)

  • Lee, Kang-Ryel;Lee, Dae-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.220.1-220.1
    • /
    • 2011
  • In recent years, the importance of Carbon Capture and Storage (hereafter CCS) is growing bigger and bigger. The development and commercialization of CCS technology are concerned for reducing carbon dioxide($CO_2$) emissions. For the most studies, the technology of $CO_2$ storage is known as the geological storage, ocean sequestration, mineral carbonation, industrial utilization, and so on. The geological storage is adjudged the most reasonable technology from economic and environmental aspects. Generally, the $CO_2$ geological storage is comprised of compression - transportation - drilling/injection - storage/management process. The critical problem is a leakage of $CO_2$ in all process. For resolving a leakage problem, it is necessary to predict and build a monitoring system. Those systems are proved safety of a leakage and received positive social perceptions of $CO_2$ geological storage. For those reasons, a risk assessment of $CO_2$ geological storage is required. A risk assessment is an estimated process of the possible effects when spilling $CO_2$. Although numerous studies of risk assessment have studied, it is incomplete to evaluate a risk and disaster quantitatively. The risk assessment will be developed for domestic application and safe $CO_2$ geological storage considering characteristics of Korea.

  • PDF

An Predictive System for urban gas leakage based on Deep Learning (딥러닝 기반 도시가스 누출량 예측 모니터링 시스템)

  • Ahn, Jeong-mi;Kim, Gyeong-Yeong;Kim, Dong-Ju
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2021.07a
    • /
    • pp.41-44
    • /
    • 2021
  • In this paper, we propose a monitoring system that can monitor gas leakage concentrations in real time and forecast the amount of gas leaked after one minute. When gas leaks happen, they typically lead to accidents such as poisoning, explosion, and fire, so a monitoring system is needed to reduce such occurrences. Previous research has mainly been focused on analyzing explosion characteristics based on gas types, or on warning systems that sound an alarm when a gas leak occurs in industrial areas. However, there are no studies on creating systems that utilize specific gas explosion characteristic analysis or empirical urban gas data. This research establishes a deep learning model that predicts the gas explosion risk level over time, based on the gas data collected in real time. In order to determine the relative risk level of a gas leak, the gas risk level was divided into five levels based on the lower explosion limit. The monitoring platform displays the current risk level, the predicted risk level, and the amount of gas leaked. It is expected that the development of this system will become a starting point for a monitoring system that can be deployed in urban areas.

  • PDF

A Study on the Consultation for Technology Leakage Victim Using NLP

  • KANG, In-Seok;LIM, Heon-Wook
    • The Journal of Industrial Distribution & Business
    • /
    • v.11 no.2
    • /
    • pp.33-39
    • /
    • 2020
  • Purpose: The purpose of this study is that victims of technology leaks and people concerned about leaks complain of stress over security concerns. However, there are no psychological treatments among the government's comprehensive plans to prevent technology leaks. Therefore, the government intends to present education methods using the NLP (Neuro Linguistic Program), a collective counseling technique, to heal the psychological injury of the victims. Psychological counseling methods include cognitive behavioral therapy, psychoanalytic behavioral therapy, humanism therapy, art therapy, and other psychological therapies. Among them, NLP (Neuro Linguistic Programming) method was used. NLP has three concepts: neuron, language, and programming, and is used as a general method for group counseling. Research design, data and methodology: In relation to composition, Chapter 1 explained the purpose and necessity of the study, Chapter 2 explained the types of psychological counseling and NLPs to help understand the study, introduced the prior study related to the development of collective counseling programs through NLP, and Chapter 3 developed a security psychological counseling education program. In addition, FGI(Focus Group Interview) was conducted for professionals. Results: Corporate counseling considered most in this study should satisfy client, counselor and manager differently from individual counseling. For this purpose, the result was composed of 11 times. In order to derive personal problems for clients, they consisted of finding, loving, expressing, and emancipating self. And, It solved the leakage anxiety to suggest a professional solution for the counselor. In addition, this course helps them become familiar with counseling techniques for becoming a good security administrator. Lastly, it was configured to leave the result for the manager to suggest the organizational development method through this training. The implication of this study is to derive psychological counseling methods for security officers. Most companies in the field of security counseling complain about technology leakage stress. There is currently no psychotherapy support project under the policy. And It was developed because it can expect sales improvement from security consultation. Conclusions: In conclusion, the results were organized to be left to the manager so that he could suggest how to develop the organization through this time.

A Study on Characteristics of a Compensator System for Swash Plate Type Axial Piston Pump (사판식 액시얼 피스톤 펌프의 가변용량 시스템의 특성에 관한 연구)

  • Kim, Shin;Oh, Suk-Hyung;Jung, Jae-Youn
    • Tribology and Lubricants
    • /
    • v.14 no.4
    • /
    • pp.15-22
    • /
    • 1998
  • Recently, the importance of variable displacement piston pump is increasing in industrial world. Especially, most consumers require various range of pressures and flow rates. Pressure compensator is a system controlling flow rate in piston pump at low cost and, therefore, satisfies the need of consumers. However, the system has serious problems, such as response and leakage. The response and leakage are affected by clearance between actuator piston and cylinder, roughness of surface, and spool overlap. In this paper, these effects are investigated experimentally, and optimal clearance and chamfer is obtained. While diameter of cylinder is fixed and diameter of actuator piston is changed in this experiment, response and leakage are measured. Also parameters such as roughness and processing accuracy are changed for piston of fixed clearance. Experimental setup modelled into several parts of actuator piston, cylinder, spool, and swash plate. Input pressure is changed by function generator and proportional valve. The result of this experiment shows that leakage increases very much in proportion to the increase of clearance, and especially leakage occurs enormously when clearance is more than 0.002. The response is not good because as clearance increases leakage increases and as clearance decreases viscous damping effect increases. Accordingly, it is found out that optimal clearance range exists for tile response, within about 0.0012∼0.0014, at this time. Futhermore, the better roughness and geometrical accuracy of actuator piston are, the smaller are leakage and friction. The paper informs that response and leakage are influenced by and geometrical accuracy of actuator piston, roughness of surface, and the clearance between actuator piston and cylinder, and that optimal design of actuator piston in the pressure compensator is possible.

Rigorous Design of 22-nm Node 4-Terminal SOI FinFETs for Reliable Low Standby Power Operation with Semi-empirical Parameters

  • Cho, Seong-Jae;O'uchi, Shinichi;Endo, Kazuhiko;Kim, Sang-Wan;Son, Young-Hwan;Kang, In-Man;Masahara, Meishoku;Harris, James S.Jr;Park, Byung-Gook
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.10 no.4
    • /
    • pp.265-275
    • /
    • 2010
  • In this work, reliable methodology for device design is presented. Based on this method, the underlap length has been optimized for minimizing the gateinduced drain leakage (GIDL) in a 22-nm node 4-terminal (4-T) silicon-on-insulator (SOI) fin-shaped field effect transistor (FinFET) by TCAD simulation. In order to examine the effects of underlap length on GIDL more realistically, doping profile of the source and drain (S/D) junctions, carrier lifetimes, and the parameters for a band-to-band tunneling (BTBT) model have been experimentally extracted from the devices of 90-nm channel length as well as pnjunction test element groups (TEGs). It was confirmed that the underlap length should be near 15 nm to suppress GIDL effectively for reliable low standby power (LSTP) operation.