• 제목/요약/키워드: Industrial Technology Leakage

검색결과 192건 처리시간 0.02초

DNA 기반 곰팡이 평가기법을 활용한 주택의 실내 곰팡이 노출수준 평가 (Evaluation of Indoor Mold Exposure Level in dwelling Using DNA-Based Mold Assessment Method)

  • 황은설;서성철;이주영;류정민;권명희;정현미;조용민;이정섭
    • 한국산업보건학회지
    • /
    • 제28권4호
    • /
    • pp.382-392
    • /
    • 2018
  • Objective: Allergic diseases such as asthma due to fungal exposure in houses have increased, and proper management is urgent. Mold can grow in the air, floor, walls, and other areas according to environmental conditions, and there are many limitations to the conventional methodology for examining fungal exposure. For this reason, the degree of fungal contamination is being evaluated by ERMI (Environmental Relative Moldiness Index), a quantitative analysis method proposed by the EPA. In this study, we compared ERMI values between water-damaged dwellings and non-damaged ones to evaluate the effectiveness of Korean ERMI values. We also explored the association of ERMI values with the level of airborne mold and characteristics of dwellings. Methods: Floor dust was collected after installing a Dustream collector on the suction port of a vacuum cleaner. The collected samples were filtered to remove only 5 mg of dust, and DNA was extracted using the FastDNA SPIN KIT protocol. Results: The ERMI values were found to be 19.6 (-6.9-58.8) for flooded houses, 7.5 (-29.2-48.3) for leaks/condensation, and 0.8 (-29.2-37.9) for non-damaged dwellings. The airborne concentration of mold for flooded, leakage or condensed, and non-damaged houses were $684CFU/m^3$, $566CFU/m^3$, and $378CFU/m^3$, respectively. The correlation between ERMI values and the levels of airborne mold was low (R = 0.038), but a weakly significant association of the ERMI values with the concentration of particulate matter ($PM_{10}$) was observed as well(R=0.231,P<0.05). Conclusions: Our findings show that the reference value using ERMI can be used to distinguish water-damaged and non-damaged dwellings. It is believed that ERMI values could be a promising tool for assessing long-term fungal exposure in dwellings.

기능성 막 제조를 위한 DPPC 지질막과 탄수화물 혼합막에 관한 연구 (A Study on DPPC Lipid Membrane and its Carbohydrate Mixture Membrane for Preparation of a Functional Membrane)

  • 정택서;이재성;이기창;홍장후
    • 공업화학
    • /
    • 제7권2호
    • /
    • pp.252-260
    • /
    • 1996
  • 막의 기능설계를 하기 위하여 DPPC(dipalmitoylphosphatidylcholine)인 지질로 제조한 liposome과 DPPC와 DTAB(dodecyltrimethylammonium bromide)를 혼합하여 liposome을 제조하여 그 구조변화를 조사하였다. 막 구조의 변화는 CF(carboxylfluorescein)를 이용하여 DPPC의 상전이 온도($t_c=41^{\circ}C$) 이상과 이하에서 측정하여 평가하였다. DPPC liposome에 함유된 CF의 유출에 의한 형광강도는 $45^{\circ}C$에서 증가되었지만 $20^{\circ}C$에서는 그 변화는 관측되지 않았다. 동등한 조건에서 DPPC/DTAB liposome에서 CF 유출에 의한 형광강도의 변화는 DPPC liposome에 비하여 큰 것이 관측되었다. 이 결과는 DPPC/DTAB liposome이 불규칙한 배열을 하고 있다는 것을 시사한다. 한편 $Ca^{2+}$ 존재하에서 DPPC liposome과 DTAB/DPPC liposome에서 Quin 2의 형광강도는 $45^{\circ}C$에서 현저히 증가되었지만 $20^{\circ}C$에서는 거의 변화하지 않았다. 그리고 형광강도의 변화는 DPPC/DTAB liposome보다 DPPC liposome 쪽이 더 크게 나타났다. 이것은 DPPC/DTAB liposome의 구조가 DPPC liposome보다 더 안정하다는 것을 의미한다. 또한 형광물질인 ANS를 이용하여 막 표면의 양상을 조사한 결과 DPPC liposome과 DPPC/DTAB liposome에서 ANS의 형광강도는 $45^{\circ}C$$20^{\circ}C$에서 다른 양상을 보였다. 이 양상은 상전이 온도의 이상과 이하에서 DPPC liposome과 DPPC/DTAB liposome의 막유동성을 의미하고 그 변화량은 DPPC liposome이 DPPC/DTAB liposome보다 더 컸다. 또한 DSC에 의해 측정된 상전이 온도는 DPPC liposome의 경우 $41^{\circ}C$이었으며 DPPC/DTAB liposome의 경우에는 $32^{\circ}C$이었다. 이상의 결과로 DPPC/DTAB liposome의 분자배열 상태가 불규칙한 것을 의미한다. 그러므로 DPPC/DTAB liposome은 불규칙하게 배열되어 있지만 안정된 구조를 갖고 있다고 생각된다.

  • PDF