• Title/Summary/Keyword: Industrial Noise

Search Result 1,261, Processing Time 0.032 seconds

A Basic Study of High Frequency Rattling Noise (고주파 래틀링 소음의 기초 연구)

  • 이금정;박철희;주재만
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.88-93
    • /
    • 1998
  • Since rattling noise, which occur in mechanical linkage with free play or glove boxes in passenger cars, play an important role in the generation of industrial noise and vibration, it is interest to study these dynamics. A difference equations are derived which described the motions of a mass constrained by pre-compressed spring and forced by a high frequency base excitation. Two types of saddle are founded from these difference equations and the stable and unstable manifolds are constructed in these saddle point. For a certain region in a parameter space of exciting displacement and coefficient of restitution, transversal intersections of stable and unstable manifolds exist. Therefore it is founded that there are large families of periodic and irregular non-periodic motions in rattling system i.e. chaos motion is observed.

  • PDF

A Study on the Noise-induced Hearing Loss and Hypertension of Metal Manufacturing Workers (모 금속제품 제조업 근로자들의 소음난청과 고혈압에 관한 연구)

  • Kim, Seong Cheon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.1
    • /
    • pp.56-61
    • /
    • 1991
  • This Study was carried out to measure the noise and to evalulate the prevalence of the noise-induced hearing loss and the hypertension in metal manufacturing workers. To perform this sutdy 116 workers were tested their hearing level and hypertension. 1. In frequency analysis, the $C_5$-dip phenomenon occurred around 4000 Hz. 2. Noise intensity was correlated significantly with hearing loss at 500, 1,000, 8,000 Hz (p<0.01). 3. Average hearing loss value by 4-divided method was $32.91{\pm}5.60dB$. 4. Hearing loss steadily increased to the 10th year and steadily after that at 4000 Hz. 5. The prevalence of noise-induced hearing loss of 6,027 workers was 1.81 %. 6. The prevalence of hypertension of 116 workers was 11.2 %.

  • PDF

Study on Structural-Acoustic Characteristics for Improving Soundproof Qualities to Changeable Wall in Apartment Buildings (공동주택의 건식 가변벽체 접합부 차음성능 향상을 위한 구조음장 특성 해석기법에 관한 연구)

  • Kim, Hwa-Il
    • Journal of Environmental Science International
    • /
    • v.18 no.11
    • /
    • pp.1291-1297
    • /
    • 2009
  • The purpose of this study was to establish structural bone noise analysing method for apartments building floor with Structural-Acoustic coupling analysis. Nowadays, noise through floor is recognized as important problem with the consequence that noise isolation technique is studied in the various fields of industry. From among noise factors, resonance sound is main reason for floor's solid noise. therefore, In this study, evaluation method for composite material slab is established and that a case study is suggested with it.

The Study on Noise Reduction of a Industrial stack (산업용 Stack의 방음대책에 대한 연구)

  • Oh, Jin-Woo;Kwon, Byoung-Ha;Lee, Jang-Hyun;Lee, Hyo-Haeng;Lee, Kyu-Hyung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.462-467
    • /
    • 2008
  • 산업용 Stack은 높은 위치의 지리적 특징과 낮은 주파수의 음향특성으로 인해 발생소음도 자체를 감소시키는 것이 무엇보다 중요하다. 대표적인 방음대책은 소음기가 있으나 규모가 크고 테스트를 위한 경제적인 부담이 크므로 이론적, 해석적인 검토를 통해 Stack 소음기의 형태를 선정하고 실제 적용 현장에서의 소음기 성능을 측정하여 예측결과를 평가하였다. 산업용 Stack 소음기의 경우 소음기의 구조에 대한 문제 및 저주파 성분이 높은 Stack 소음 특성을 고려하여 조건에 적합한 +형 스프리터 소음기를 설계, 적용하였다. 현장측정결과 문제대역인 저주파 대역에서 뚜렷한 소음감소를 나타내는 것을 알 수 있었다.

  • PDF

A Case Study of Dispute Mediations on Construction Noise and Vibration Damages (건설소음진동 피해분쟁조정 사례분석에 관한 연구)

  • 곽광수;김재수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.108-113
    • /
    • 2001
  • Recently people have come to demand more pleasant environments as the quality and right of life have been improved. Along with industrial development, the tendency is causing a growing number of disputes concerning environmental damages. Of many kinds of environmental damages, noise and vibration pollution rising at construction fields are particularly the most common subjects of public grievance. Thus the government launched the Environmental Dispute Mediation Committee in 1991, purposing to utilize fully the promptness and expertise of administrative institutes and to resolve environmental damage disputes promptly and fairly by interfering in them actively. With the prompt and fair dispute mediations of the committee, people came to be able to get fair and prompt remedies for damages in their health and fortune by environmental pollution. Therefore, by analyzing dispute mediation cases on construction noise and vibration damages, we will suggest basic material on which efficient actions can be taken for public grievances happening in the future.

  • PDF

A Study on the Fan and Scroll for Ventilation (배기용 Fan Scroll에 대한 연구)

  • Song, S.B.;Park, S.I.;Lee, J.S.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.402-406
    • /
    • 2000
  • In the Over-The-Range, the outlet size is limited by the industrial standards. Therefor to enlarge the volume of cavity, the installation height of ventilation fan is become small, the system resistance is higher than before. For that reason, the important design variables such as the diameter of a fan, the scroll expansion angle, etc. which play the significant role on flow rate and noise, are confined. In this study, we made an experiment of the diameter of fans relation to scroll expansion angle and investigated flow rate of the length of fans in enlarged cavity volume of OTR, and then we designed the new scroll to improve the flow rate and noise level. As a result, flow rate increased to 110% compared to current scroll and the blade passing frequency of a fan is disappeared by inclined cut-off shapes.

  • PDF

Active Noise Cancellation using a Teacher Forced BSS Learning Algorithm

  • Sohn, Jun-Il;Lee, Min-Ho;Lee, Wang-Ha
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.224-229
    • /
    • 2004
  • In this paper, we propose a new Active Noise Control (ANC) system using a teacher forced Blind Source Separation (BSS) algorithm. The Blind Source Separation based on the Independent Component Analysis (ICA) separates the desired sound signal from the unwanted noise signal. In the proposed system, the BSS algorithm is used as a preprocessor of ANC system. Also, we develop a teacher forced BSS learning algorithm to enhance the performance of BSS. The teacher signal is obtained from the output signal of the ANC system. Computer experimental results show that the proposed ANC system in conjunction with the BSS algorithm effectively cancels only the ship engine noise signal from the linear and convolved mixtures with human voice.

Noise Characteristic Analysis of 3-phase SRM for Traction Applications (견인용 3상 SRM의 소음특성 해석)

  • 안진우;이동희;안영주
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.4
    • /
    • pp.224-228
    • /
    • 2004
  • The switched reluctance motor(SRM) drive system provides a good adjustable speed and torque characteristics. SRM has the possibility of maintaining full power over a wide speed range. So, many attempts are being done from home appliances to industrial machinery and tools. Especially, the traction drive of SRM is one of a good application due to it's torque characteristics. However, because of the switching mechanism, it has some disadvantage of noise and vibration. It is difficult to adopt to an appliance demanding silence. A noise simulations and test of 3-phase 6/4, 6/8 and 12/8 SRM were done in other to compare each other. The test results show that 12/8 SRM has good noise characteristics.

Basic Study of Radial Distributions of Electromagnetic Vibration and Noise in Three-Phase Squirrel-Cage Induction Motor under Load Conditions

  • Hirotsuka, Isao;Tsuboi, Kazuo;Takahashi, Yousuke
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.2
    • /
    • pp.154-158
    • /
    • 2013
  • Reduction of electromagnetic vibration and acoustic noise from three-phase squirrel-cage induction motors (IMs) is very important, particularly from the standpoint of environmental considerations. Although the electromagnetic vibration of IMs has been studied for several years, the relationships between the radial distribution of the electromagnetic vibration and noise and the electromagnetic forces responsible for them have not yet been analyzed in sufficient detail. In the present study, we investigated this relationship experimentally for a small IM under different load conditions. Our results clearly show that the radial distributions of the dominant electromagnetic vibration and noise components match the mode shape of the dominant electromagnetic force producing these components.

A Development of COS Fuse Holder to Reduce an Impact Ambient Noise (충격성소음저감용 COS 휴즈 홀더 개발)

  • Cho, Hyun-Seob;Min, Jin-Kyoung
    • Proceedings of the KAIS Fall Conference
    • /
    • 2006.11a
    • /
    • pp.176-179
    • /
    • 2006
  • We are using COS to purpose blocking the excess current and to protect the transformer. But the fuse of COS is melt due to the overload if the excess current flows and it destroy an air severing relations to clear as strong arc happens. Such phenomenon induces an impact ambient noise and it gives the circumstance area resident or pedestrian the fear. Thus, We are the actual circumstances which an ambient noise countermeasure establishment have desired urgently. In this study, we grasp the characteristic of an impact ambient noise which a COS fuse happens the melting and study the method to reduce an impact ambient noise.

  • PDF