• Title/Summary/Keyword: Industrial Inspection

Search Result 865, Processing Time 0.022 seconds

A Study on the Real Condition and the Improvement Directions for the Protection of Industrial Technology (산업기술 보호 관리실태 및 발전방안에 관한 연구)

  • Chung, Tae-Hwang;Chang, Hang-Bae
    • Korean Security Journal
    • /
    • no.24
    • /
    • pp.147-170
    • /
    • 2010
  • This study is to present a improvement directions for the protection of industrial key technology. For the purpose of the study, the survey was carried out on the administrative security activity of 68 enterprises including Large companies, small-midium companies and public corporations. survey result on the 10 items of security policy, 10 items of personal management and 7 items of the assets management are as follows; First, stable foundation for the efficient implement of security policy is needed. Carrying a security policy into practice and continuous upgrade should be fulfilled with drawing-up of the policy. Also for the vitalization of security activity, arrangement of security organization and security manager are needed with mutual assistance in the company. Periodic security inspection should be practiced for the improvement of security level and security understanding. Second, the increase of investment for security job is needed for security invigoration. Securing cooperation channel with professional security facility such as National Intelligence Service, Korea internet & security agency, Information security consulting company, security research institute is needed, also security outsourcing could be considered as the method of above investment. Especially small-midium company is very vulnerable compared with Large company and public corporation in security management, so increase of government's budget for security support system is necessary. Third, human resource management is important, because the main cause of leak of confidential information is person. Regular education rate for new employee and staff members is relatively high, but the vitalization of security oath for staff members and the third party who access to key technology is necessary. Also access right to key information should be changed whenever access right changes. Reinforcement of management of resigned person such as security oath, the elimination of access right to key information and the deletion of account. is needed. Forth, the control and management of important asset including patent and design should be tightened. Classification of importance of asset and periodic inspection are necessary with the effects evaluation of leak of asset.

  • PDF

Fundamental Properties of Low Strength Concrete Mixture with Blast Furnace Slag and Sewage Sludge (고로슬래그미분말 및 하수슬러지를 활용한 저강도 콘크리트의 기초적 물성)

  • Kwon, Chil Woo;Lim, Nam Gi
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.3
    • /
    • pp.136-144
    • /
    • 2013
  • In this study, in order to establish a plan that will enable safe use of renewable resources such as diverse industrial by-products and urban recycled materials, we conducted experiments that focused on flow, bleeding, compressive strength and environmental pollution evaluation to evaluate the material properties of low strength concrete using BFS and SS. In the case of low strength concrete using BFS and SS, blending of at least BFS 6000 within a 30% range regardless of the type of sand used was found to be the most effective approach for improving the workability by securing the minimum unit quantity of water, restraining the bleeding ratio and establishing compressive strength by taking account of the applicability at the work site. In particular, in view of the efficient use of SS, the optimal mixing condition was found to be the mixing of BFS 8000 with in the 30% range, not only for improving the workability restraining the bleeding ratio and establishing the compressive strength but also for application to the work site. Further, the results of tests on hazardous substance content and those of elution tests conducted on soil cement using SS indicated that all values satisfied the environmental standards without any harmful effects on the surrounding environment.

The Effects of Self-Healing for Ternary Blended Cement in Tap-water and Sea-water (삼성분계 시멘트의 해수와 담수에서의 자기치유 효과)

  • Kim, Tae-Wan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.6
    • /
    • pp.10-19
    • /
    • 2016
  • The objective of this study is to investigate the self-healing properties of ternary blended cement(TBC) paste made with OPC, GGBFS and FA. The influence of OPC-GGBFS-FA on the self-healing ability of ternary blended cement paste was researched by ultrasonic pulse velocity(UPV) measurement. The TBC paste with GGBFS-FA replacement ratios of 20%, 40% and 60% were prepared having a constant water-cementitious materials ratios os 0.5. The research focuses on behavior after 28days(after loading). Four-point bending tests are used to pre-cracked the prismatic specimens at 28days. For specimens (uncracked and cracked) submerged in tap-water and sea-water until 60days. According to the experimental results, the TBC paste system has self-healing ability increased when the fraction of GGBFS increased. Because GGBFS and FA continues to hydrate after 28days, it is likely that hydrated products from GGBFS and FA may modify microstructures, seal these cracks. From these results, it is clear that the crack in all samples experience self-healing and that this occurs mostly in the first 30days of submerging. Futhermore, most of the healing for both specimens of submerged in sea-water and tap-water occurred during the first 30days. Sea-water submerged specimens healed cracks as fast as those in tap-water. Differences in healing effects of submerged in sea-water and tap-water may be attributed to the presence of specific sea-water ions. Therefore, self-healing effects considered age-effects was more strong effect occurred mostly in the first 30days, and then gradually weaken.

The Fundamental Characteristics for Mix Proportion of Multi-Component Cement (배합비에 따른 다성분계 시멘트의 기초특성)

  • Kim, Tae-Wan;Jeon, Jae-Woo;Seo, Min-A;Jo, Hyeon-Hyeong;Bae, Su-Yeon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.3
    • /
    • pp.66-74
    • /
    • 2016
  • The aim of this research work is to investigate the mix proportion of multi-component cement incorporating ground granulated blast furnace(GGBFS), fly ash(FA) and silica fume(SF) as an addition to cement in ternary and quaternary combinations. The water-binder ratio was 0.45. In this study, 50% and 60% replacement ratios of mineral admixture to OPC was used, while series of combination of 20~40% GGBFS, 5~35% FA and 0~15% SF binder were used for fundamental characteristics tests. This study concern the GGBFS/FA ratio and SF contents of multi-component cement including the compressive strength, water absorptions, ultrasonic pulse velocity(UPV), drying shrinkage and X-ray diffraction(XRD) analysises. The results show that the addition of SF can reduce the water absorption and increase the compressive strength, UPV and drying shrinkage. These developments in the compressive strength, UPV and water absorption can be attributed to the fact that increase in the SF content tends basically to consume the calcium hydroxide crystals released from the hydration process leading to the formation of further CSH(calcium silicate hydrate). The strength, water absorption and UPV increases with an increase in GGBFS/FA ratios for a each SF contents. The relationship between GGBFS/FA ratios and compressive strength, water absorption, UPV is close to linear. It was found that the GGBFS/FA ratio and SF contents is the key factor governing the fundamental properties of multi-component cement.

Consideration on Rating Method for Heavy Impact Sound Taking Account of the Characteristics of Floor Vibration and Impact Sources (바닥 진동 거동 및 충격원 특성을 고려한 바닥 중량 충격음 평가방법 고찰)

  • Lee, Min-Jung;Choi, Hyun-Ki
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.4
    • /
    • pp.69-79
    • /
    • 2017
  • The purpose of this study is to reconsider the rating method for the floor impact sound insulation performance in current criterion. Although there are some arguments about proper standard heavy impact source with reproducibility of actual impact source in residence building, bang machine is adopted as the only standard heavy impact source in domestic criterion. To inspect the rating methods of evaluation criteria, this study conducted vibration test for both of standard heavy impact sources and actual impact sources. Using the test results, the floor impact sound insulation performance levels were assessed by each of several criteria. In addition, low frequency noise beyond current criteria was evaluated. Consequently, the floor impact sound levels have different performance levels according to adopted criteria, and measured floor impact sounds are bound to annoy the neighbors in the low frequency range. Current criteria does not consider the spectrum characteristics of floor impact sound according to impact sources and low frequency noise. This may cause the difference between the floor impact sound insulation performance level and human perception. Thus current criterion needs to be complemented to reflect the spectrum characteristics of floor impact sound levels according to impact sources and sound pressure levels in low frequency range.

Properties of Non-Sintered Cement Pastes Immersed in Sea Waters at Different Temperatures for Binders Mixed with Different Ratios (침지된 해수 온도 및 결합재 혼합비에 따른 비소성 시멘트의 강도 특성)

  • Jun, Yubin;Kim, Tae-Wan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.5
    • /
    • pp.75-84
    • /
    • 2016
  • This paper presents an investigation of the mechanical properties on non-sintered cement pastes immersed in sea waters at three different temperatures. The non-sintered cement pastes were synthesized using blended binder(Class F fly ash; FA and ground granulated blast furnace slag; GGBFS) and alkali activator(sodium hydroxide and sodium silicate). Binders were prepared by mixing the FA and GGBFS in different blend weight ratios of 6:4, 7:3 and 8:2. The alkali activators were used 5wt% of blended binder, respectively. Calcium carbonate was used as an chemical additive. The compressive strength, bulk density and absorption of alkali-activated FA-GGBFS blends pastes were measured at 3 and 28 days after immersed in sea waters at three different temperatures($5^{\circ}C$, $15^{\circ}C$ and $25^{\circ}C$). The XRD and SEM tests of the pastes were conducted at 28 days. Water-soluble chloride(free chloride) and acid-soluble chloride(total chloride) contents in the pastes were also measured after 28 days immersion in sea water. The experimental results showed that increasing the content of FA in alkali-activated FA-GGBFS blends pastes immersed in sea water increases the absorption, water-soluble chloride content and acid-soluble chloride content, and reduces the compressive strength and bulk density. And it was found that there was a variation of strength change for the alkali-activated FA-GGBFS blends pastes immersed in sea waters at three different temperatures that depends on the blending ratio of FA and GGBFS.

Fire Resistance Behavior and Residual Capacity of Voided Slab Subjected to Fire According to Loading Condition (화재 시 하중 재하 조건에 따른 중공슬래브의 내화거동 및 잔존성능)

  • Choi, Hyun-Ki;Bae, Back-Il;Jung, Hyung-Suk;Choi, Chang-Sik;Choi, Joo-Hong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.99-106
    • /
    • 2018
  • This study presents experimental investigation on the residual capacity of fire-damaged voided slabs according to loading conditions. In this study, two voided slab specimens were fabricated, and heated by ISO standard fire during 120 minutes with different loading conditions of presence of loading. These specimens were cooled down to room temperature, and the residual capacity of fire-damaged voided slabs was investigated. Based on test results, thermal distribution of voided slab through the depth of concrete sections is different by the loading conditions. The temperature of loaded specimen is rapidly elevated through the whole depth of concrete sections compared to the unloaded specimen. The residual strength of fire-damaged voided slab specimens are 60% and 66% of that of voided slab specimen without fire damage, and the residual stiffness of fire-damaged voided slab specimens decreases by 15%~23% of that of voided slab specimen without fire damage. In case of voided slab specimens subjected ISO standard fire, the loaded specimen shows the decrease of 10% in the residual strength and the decrease of 15% in the residual stiffness compared to the unloaded specimen. It seems to result from higher temperature of bottom reinforcements in the loaded specimen due to the cracks, and more extensive damage on concrete cover of reinforcements by spalling process according to load level.

An Investigation on the Ultimate Strength of Duplex Stainless Steel (STS329FLD) Bolted Connections with Two Bolts (2행 1열 듀플렉스계 스테인리스강(STS329FLD) 볼트접합부의 최대내력 조사)

  • An, Sung-Ho;Kim, Geun-Young;Hwang, Bo-Kyung;Kim, Tae-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.5
    • /
    • pp.55-63
    • /
    • 2018
  • Recently, the use of duplex stainless steel which with a two-phase microstructure (equal mixture of ferrite and austenite) has been increased in a variety of industrial fields due to higher strength leading to weight saving, greater corrosion resistance(particularly, stress corrosion cracking) and lower price. However, currently, stainless steels are not included in the structural materials of Korean Building Code and corresponding design standards are not specified. In this paper, experimental studies have been performed to investigate the structural behaviors of duplex stainless steel (STS329FLD) bolted connection with two bolts for providing the design data. Main variables are shear connection type (single shear and double shear) and end distance parallel to the direction of applied force. Fracture modes at the final step of test were classified into typical block shear fracture, tensile fracture and curling. Curling occurrence in single shear connection led to ultimate strength drop by up to 20%. Test strengths were compared with those by current design specifications such as AISC/AISI/KBC, EC3 and AIJ and proposed equations by existing studies. For specimens with no curling, Clement & Teh's equation considering the active shear plane provided a higher strength estimation accurancy and for specimens with curling, Kim & Lim's equation considering strength reduction by curling was also overly unconservative to predict the ultimate strength of curled connections.

A Study Scope of Optimal Heating and Drying Process of Timber Heated by Microwave (초고주파 가열 목재의 최적 가열 및 건조 공정범위 도출에 관한 연구)

  • Shin, Ki-Hoon;Park, Cheul-Woo;Son, Dong-Won;Lim, Nam-Gi
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.4
    • /
    • pp.126-137
    • /
    • 2014
  • Characteristics of heating and drying of Canadian-imported Douglas-fir timber using microwave in order to secure convenience and quality of drying timber and to get basic data for secondary conservation treatment are as follows: As the results of analysis of change curves of internal temperature of the timber after irradiating it, round timber and board timber showed stable heat distribution, heat consumption and surface water-content in heating with 30kW for 30 minutes and 120 minutes and with 40kW for 3 minutes and 9 minutes, respectively. Especially, surface water-content distribution according to heating by microwave showed very even leveling and water-content decrease rate was also more 30% compared to its weight showing excellent dry efficiency. And in case of soaking timbers into liquid chemicals for secondary conservation according to the analysis results of heat consumption, it is expected that large amount of preservative will be permeated. Therefore, timber heated by microwave is remarkably available for using industrial materials and developing secondary utilized products with its fast water-content decrease and dryness and higher heat consumption.

Design of Operation Management Check Items of Efficient Information System for Improvement of Business Continuity based on ISO 22301 (ISO22301 기반 비지니스 연속성 증대를 위한 효율적인 정보시스템 운영감리 점검항목 설계)

  • Joo, Nak Wan;Kim, Dong Soo;Kim, Hee Wan
    • Journal of Service Research and Studies
    • /
    • v.9 no.2
    • /
    • pp.31-40
    • /
    • 2019
  • In this paper, we have studied the improvement of operational control for the enhancement of business continuity of information system becoming more important with the development of information technology such as big data, Iot, and artificial intelligence. The operational management and audit guidance of the current information system, which is coming in the fourth industrial age, where various services, data and industries are converged, is based on the existing general information system pattern and needs to be improved. The provision of services at fixed times is linked to the survival of enterprises and countries and serves as a key element. Therefore, it is necessary to study the application of optimized check items of the operation audits to minimize the service interruption damage of the information system and to provide the stable service in terms of business continuity management. To accomplish this, the check items presented in the operational control of the information system were derived by combining the PDCA step contents and 8 resource requirements provided in ISO 22301. From the point of view of increasing the business continuity according to the derivation criteria of the inspection items, the operational inspection check items were derived by exemplifying the improved check items and review items of the information system operation audit and the products to be checked during the operational audit. The check items were divided into management audit improvement check items for service continuity management, and operational audit improvement check items for performance and availability management. The average score of the IT professionals' survey on the suitability of the proposed checklist was 4.63, which was concluded to be appropriate.