• Title/Summary/Keyword: Industrial Complex Watershed

Search Result 12, Processing Time 0.021 seconds

COUNTING OF FLOWERS BASED ON K-MEANS CLUSTERING AND WATERSHED SEGMENTATION

  • PAN ZHAO;BYEONG-CHUN SHIN
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.27 no.2
    • /
    • pp.146-159
    • /
    • 2023
  • This paper proposes a hybrid algorithm combining K-means clustering and watershed algorithms for flower segmentation and counting. We use the K-means clustering algorithm to obtain the main colors in a complex background according to the cluster centers and then take a color space transformation to extract pixel values for the hue, saturation, and value of flower color. Next, we apply the threshold segmentation technique to segment flowers precisely and obtain the binary image of flowers. Based on this, we take the Euclidean distance transformation to obtain the distance map and apply it to find the local maxima of the connected components. Afterward, the proposed algorithm adaptively determines a minimum distance between each peak and apply it to label connected components using the watershed segmentation with eight-connectivity. On a dataset of 30 images, the test results reveal that the proposed method is more efficient and precise for the counting of overlapped flowers ignoring the degree of overlap, number of overlap, and relatively irregular shape.

Analysis of Rainfall-Runoff Characteristics in Shiwha Industrial Watershed Using SWMM (SWMM 모형을 이용한 시화호 유역의 강우 유출 특성 분석에 관한 연구)

  • Lee, Hye Won;Choi, Jung Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.1
    • /
    • pp.14-22
    • /
    • 2015
  • In order to analyze the flow and pollutant runoff characteristics of industrial area, SWMM (Storm Water Management Model) was applied. The model was calibrated based on the measured data in the waterway of Sihwa industrial complex during six events, 2008-2009. The build-up process of pollutants is expressed as Power-linear form and washoff as Power-Exponential form. The validated model was used to analyze the change of the runoff characteristics in the industrial area. In the study area, runoff flow is decreased with an increase in impervious area, but there is no significant change in peak time. The results of this study will be used as basic information of impervious area reduction and watershed management in industrial areas.

Pollutants Unit Loadings of the Stormwater Runoff in Industrial Complex (강우시 산업단지에서의 유출오염부하량 원단위 산정)

  • Lee, Jun-Ho;Bang, Ki-Woong;Choi, Jong-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.2
    • /
    • pp.355-362
    • /
    • 2000
  • The objective of this paper is to estimate the pollutant load based on event mear concentrations(EMC) in industrial complex. Eight sub-basins in the Chongju industrial complex were selected for sampling and study with different characteristics during the period from June 1997 to August 1998. During the storm events, measured EMC ranges of $BOD_5$, COD, SS, TKN, TP, HEM, $NO_3-N$, $PO_4-P$, Cr, Pb, Cu and Fe in the industrial complex watersheds were 11~176mg/L, 40~502mg/L, 23~633mg/L, 104~20.9mg/L, 0.22~7.51mg/L, 12.7~548.7mg/L, 0.06~2.66mg/L, 0.12~3.39mg/L, 0.01~0.50mg/L. 0.02~0.42mg/L, 0.01~0.15mg/L and 1.29~11.51mg/L respectively. And the calculated annual average pollutant unit loadings of $BOD_5$ COD, SS, TKN, $NO_3-N$, $PO_4-P$, TP, HEM, Cr, Pb, Cu and Fe were 374.4kg/ha/yr 924.1kg/ha/yr, 983.6kg/ha/yr, 48.8kg/ha/yr, 8.1kg/ha/yr, 9.7kg/ha/yr, 17.8kg/ha/yr 943.0kg/ha/yr, 0.7kg/ha/yr, 0.9kg/ha/yr, 0.3kg/ha/yr and 28.9kg/ha/yr, respectively.

  • PDF

Characterization of Dissolved Organic Matter in Stream and Industrial Waste Waters of Lake Sihwa Watershed by Fluorescence 3D-EEMs Analysis (형광 3D-EEMs를 이용한 시화호유역 하천 및 공단폐수의 유기물 특성 분석)

  • Lee, Mi-Kyung;Choi, Kwang-Soon;Kim, Sea-Won;Kim, Dong-Sup
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.9
    • /
    • pp.803-810
    • /
    • 2009
  • This study is conducted to examine spatial variations of Dissolved Organic Matter (DOM) in stream and waste waters of the different watershed areas (agricultural, residential, and industrial complex area) by using fluorescence 3D-EEMs (3 Dimensional Excitation Emission Matrix Spectroscopy). Furthermore, the research investigates the changes of DOM characterization by synchronous and 3D-EEMs during a rainfall event. The characterizations of DOM obtained by 3D-EEMs show two noticeable peaks at humic and protein-like regions. Humic-like substances (HLS) are found in rural and urban areas, and humic and protein-like substances (PLS) are shown in industrial area. According to the fluorescence peak $T_1:C_1$ ratios, it is observed that high amount of HLS was discharged from Banweol Industrial Complex (3TG). Additionally, linear relationships (Regression rate, $r^2$=0.65, $r^2$=0.66) have been shown between PLS (peak $T_1,\;B_1$) and biochemical oxygen demand (BOD), which indicates the impact of sewage. For the rainfall event (30 mm), no remarkable difference of DOM was found at rural area except increment of fluorescence intensity comparing dry period. In contrast, HLS at urban area is highly discharged within 30 minutes from the beginning of rainfall. Also, there are high influences of HLS and PLS within 20 minutes at industrial complex (4TG). Fluorescence 3D-EEMs has not only verifies a watershed of DOM origination but also monitors diffuse and point source impacts.

A Study of GIS-based Estimation of Pollutant Loads in Accordance with Spatial Landuse Variation - Focussing on Wangsook Watershed - (토지이용의 공간적 다양성에 따른 GIS 기반 오염부하 산정에 관한 연구 - 왕숙천 유역을 중심으로 -)

  • Kim, Kyoung-Soon;Kim, Kye-Hyun;Kwon, Oh-Jun
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.5
    • /
    • pp.305-315
    • /
    • 2005
  • The scheme to classify pollution sources in Korean TMDL planning has been pointed out too much complex to implement practically because of requiring a wide range of items to be collected from a field. Within a deficient situation to collect field data, the mathematical scheme that focuses only on counting an uniform area ratio of the different land uses to estimate of pollutant loads from individual sub-catchments has been used without taking into account of the spatial characteristics of major land uses as well as the locations of pollution sources in each sub-catchment. It would cause to significant level of errors to estimate the pollution loads. Therefore, this study proposes a renovated scheme that can be adopted more easily to classify pollution sources in the watershed and reduce the estimation errors in the spatial distribution of pollution sources by introducing a spatial analysis based on digital land cover maps. In order to estimate a unit area to calculate the uniform pollution load, the pollution response unit area that is locating spatially at the same place and having same land use is identified through the application of GIS overlay technique. Unlikely existing conventional method to calculate the pollution load based on equal distribution of pollutants for each administrative boundary, it is assumed that the pollution load from household and livestock sources are generated and washed off from only residential areas. While, pollution from business population comes from commercial area and industrial load from wastewater discharge facilities are from industrial areas. From comparison of the calculated results from the existing the method and the proposed one, it is found that although the estimation of pollution load from sub-catchment in the case of the existing conventional method application results in negligible difference in total pollution amounts from the whole area of Wangsook watershed as a study area, significant difference of pollution load among sub-catchment in which pollution response unit areas are diverse, however, appears in the case of the application of the renovated scheme.

COD Pollutants Load Estimation Schemes in Lake Shihwa and Incheon Coastal Zone (시화호 및 인천연안의 COD 오염부하량 추정기법)

  • Cho Hong-Yeon;Cho Bum-Jun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.18 no.3
    • /
    • pp.262-267
    • /
    • 2006
  • For the concentration management in COD parameters, it requires the measurement and estimation of the COD pollutants load (hereinafter PL) in the watershed. The estimation method of the PL, however, is provided only based on the BOD parameters. The development of COD PL estimation schemes is expected to execute total PL management in coastal zone and needs to more observation and much time. This study provides COD PL estimation schemes using statistical information about ratio analysis with COD & BOD concentration of rivers and drainages of an industrial complex in Lake Shiwha and Incheon Coastal Zone watershed. The COD PL is computed with ease by multiplying the conversion factor, which is calculated as the sum of the average and 1 to 3 (safety factors) times standard deviation. The conversion factor of Lake Shihwa and Incheon Coastal Zone is estimated as 1.7, 2.3 and 2.9 with respect to the safety factor 1, 2, and 3, respectively.

Seasonal Variation Estimation of Inflow Pollutant Loads of Yeong-il Bay by using Tank Model (Tank모델에 의한 영일만 유입오염부하량의 계절변동 예측)

  • Lee In-Cheol
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.6 no.3
    • /
    • pp.63-71
    • /
    • 2003
  • This study investigated about the seasonal variation of pollutant loads flowing into the Yeong-il bay from constructing Tank model which is the simulation model to evaluate the daily river discharge and pollutant load in the Hyeong-san river watershed. The estimated annual average river discharge of Hyeong-san river flowing into Yeong-il bay is about 878.34×10/sup 6/㎥/year which is about 73% of annual average of total precipitation in Hyeong-san river watershed. The annual average of pollutant load flowing into Yeong-il bay was estimated each 15.11 ton-COD/year, 23.24 ton-SS/year, 10.65 ton-TN/year, and 0.54 ton-Tp/year. For the seasonal variation of pollutant loads, it was tended as increasing of river discharge as increasing of inflow pollutant loads at June and July of summer and October of autumn. The main source of pollutant loads was found to be the Pohang city and Pohang industrial complex which are located near the mouth of Hyeong-san river. Therefore, for effective water quality management of Yeong-il bay, the counterplan to reduce pollutant loads from the main source of pollutant loads is required.

  • PDF

Analysis of Specific Contaminated Status and Pollutant Loads Contribution Rate of the Tributaries in Gumho and Nam River Basin (금호강, 남강 중권역 지류·지천의 상세오염 현황 및 오염기여율 조사)

  • Na, Seungmin;Kwon, Heongak;Kim, Gyeong Hoon;Shin, Dongseok;Im, Tae Hyo
    • Journal of Wetlands Research
    • /
    • v.18 no.4
    • /
    • pp.363-377
    • /
    • 2016
  • This study was investigated the pollutant load, contamination properties, pollution condition of the fine parts of tributary, the influence of Nakdong river watershed and etc. in the tributaries. The contaminated tributaries were that among the Kumho and Nam river or were too far from site of water quality monitoring stations, regularly. As a result, the water quality level was almost similar between Nam and Kumho River, except for certain parameter including TN(Total Nitrogen), Chl-a(Chlorophyll-a) and SS(Suspended Solid) in which Kumho river were 20~120%. The point discharge load(kg/day) and load density ($kg/day/km^2$) of tributaries were different the pollution level according to the flow-rate ($m^3/sec$) and stream influence area($km^2$), and the difference of these was observed highly at Nam river. Specific contamination investigation of tributaries in Nam and Kumho river watershed was conducted from two to nine points of the fine parts of tributaries depending on the confluence sites and shapes. This result observed high at the Dalseocheon and Uriyeongcheon, respectively. Beside, the pollutant load contribution rate of Nakdong watershed was high about 10% at the Dalseocheon and Uiryeongcheon. This was due to the differences of the environments about the industrial complex, metropolis residence property, agricultural cultivation, livestock pen and the downstream of non-point source.

Securing Water Resources Sites within Seok-mun Industrial Complex Watershed (석문 국가산업단지의 자체유역 수원 확보 연구)

  • Noh, Jae-Kyoung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.327-331
    • /
    • 2010
  • 충남 당진에 위치한 1,200만$m^2$의 석문 국가산업단지의 개발에 따라 용수수요는 $5m^3/m^2$/년를 적용하면 6,000만$m^3$/년 정도 예상된다. 충남 서북부의 다른 산업단지에서 요구되는 용수수요로 물 확보가 크게 대두되고 있으며, 석문 담수호가 조성돼 있지만 수질관리와 용수를 위해 자체유역에 추가로 수원을 확보할 필요가 있다. 석문 담수호는 유효저수량 910만 $m^3$, 총저수량 1,461만 $m^3$, 만수위 EL.-1.70 m, 사수위 EL.-3.00 m, 수혜면적 1,546 ha, 유역면적 $252.2km^2$이며, 당진읍의 인구 4만 6천명의 생활용수 회귀수와 유역의 농업용수 회귀수를 고려하여 유입량을 모의하고 담수호의 일별 저수량 변화를 분석한 결과 공업용수를 연간 3,500만 $m^3$ 공급할 수 있으며 2,500만 $m^3$이 부족한 것으로 분석되었다. 또한 상류에 유효저수량 937만 $m^3$, 총저수량 972만 $m^3$, 만수위 EL.86.90 m, 사수위 EL.64.60 m, 수혜면적 1,293.8 ha, 유역면적 $25.9km^2$인 고풍 저수지가 위치하고 있으며, 증고에 의해 총저수량을 1,946만 $m^3$로 증가시켜도 석문 담수호의 용수공급능력은 거의 증가되지 않는 것으로 분석되었다. 고풍저수지의 유역배율이 2배 정도가 돼, 증고에 의한 하류 하천 유량은 거의 증가되지 않는 것으로 분석되었으며, 고풍저수지를 이용한 석문 자체유역의 수원확보는 타당하지 않은 것으로 밝혀졌다. 따라서 다른 수원확보를 위한 면밀한 검토가 절실히 요구된다.

  • PDF

Estimation of Dissolved Oxygen in Streams using Reaeration, 1st Production and Respiration Rates (재포기 계수, 1차 생산율 및 호흡률을 이용한 하천의 용존산소 추정)

  • Kim, Kyung-Sub;Hwang, Sung-Gyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.6
    • /
    • pp.428-433
    • /
    • 2009
  • Dissolved oxygen is considered as one of the important water-quality constituents in streams from one century ago and fishes perish in low dissolved oxygen concentration. Environmental scientists and engineers have introduced the deterministic model to estimate dissolved oxygen concentration of streams and recommended the use of the Delta Method (DM), Approximate Delta Method (ADM), Extreme Value Method (EVM) and Optimization Method (OPT) which can be applied in no spatial variation of dissolved oxygen. The diurnal or annual variation of dissolved oxygen is mainly determined from the parameters such as reaeration rate, 1st production rate and respiration rate which are related to dissolved oxygen. Each method was briefly introduced and applied to two sampling sites of Anseong Stream watershed in this paper. The limitation, advantages and disadvantages of each method were reviewed and analyzed after running the each method. From these analyses, the benefit-cost approach to estimate dissolved oxygen effectively in streams was recommended.