• Title/Summary/Keyword: Industrial Application

Search Result 6,415, Processing Time 0.041 seconds

A Study for the Shoes Micro-sized Manufacturing Industry and the Development of the Government Policy: Surveyed on Beomcheon-Dong in Busan (신발소공인 산업의 실태분석 및 정책지원 방향: 부산진구 범천동을 중심으로)

  • Kim, Chul Min;Kim, Nog Hyeon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.22 no.6
    • /
    • pp.47-59
    • /
    • 2017
  • Korean Economy has been developed by the Korean Government's Support for the Large-sized Firms. This Government Policy causes the Polarization between Large-sized and Micro-sized Firms Aggravated. Micro-sized Firms are distributed over the Whole Industry Area, and can also cause the Economic Crisis If They are crashed down. Therefore Government Policy for the Micro-sized Manufacturing Industry is very Important Issue. This Paper Focused on the Analysis of Current Status for the Shoes Micro Manufacturing Industry. For the Effective Analysis, This Paper uses the Statistical Data Open to the Public and also conducts the Survey for the Micro-sized Firms in Busan. Statistical Program is used for Analyzing the Collected Data and the Major Findings are as Follows. First, Shoes Industry is led by the Micro and Small & Medium sized Firms rather than the Large-sized. And the Micro-sized Firms are getting the High Rate among the Whole Shoes Industry. Busan is heavily populated Area as the Origin of Shoes Industry. Second, even though Most of the Owner of the Micro-sized Firms have the High Technology Skill Level, Worker's Aging Phenomenon gets Worse and causes the Technology Handing down to the Next Generation Difficult. Third, Because the Factory Facility of the Micro-sized Firms is Dirt and Unstable, the Modernized Manufacturing Infrastructure such as the Apartment Factory Facility is Necessary. Forth, as the Micro-sized Firms which have the Intangible Asset such as Patent is Few, the Government Policy for Encouraging the Patent Application is strongly Needed. Fifth, Entrepreneurship and Collaboration Mind between Micro-sized Firms are Lacked, so Establishment of the Cooperative Union is required. Finally, the Effort for the Systemic Planning for the Management is lacked, and the Introduction of the Management Innovation is strongly needed. The Limitation and Future Research Direction is also discussed.

A Study on Comparative Analysis of Socio-economic Impact Assessment Methods on Climate Change and Necessity of Application for Water Management (기후변화 대응을 위한 발전소 온배수 활용 양식업 경제성 분석)

  • Lee, Sangsin;Kim, Shang Moon;Um, Gi Jeung
    • Journal of Korean Society of societal Security
    • /
    • v.4 no.2
    • /
    • pp.73-78
    • /
    • 2011
  • In order to resolve the problem of change in global climate which is worsening as days go by and to preemptively cope with strengthened restriction on carbon emission, the government enacted 'Framework Act on Low Carbon Green Growth' in 2010 and selected green technology and green industry as new national growth engines. For this reason, the necessity to use the un-utilized waste heat across the whole industrial system has become an issue, and studies on and applications of recycling in the agricultural and fishery fields such as cultivation of tropical crops and flatfishes by utilizing the waste heat and thermal effluent generated by large industrial complexes including power plants are being actively carried out. In this study, we looked into the domestic and overseas examples of having utilized waste heat abandoned in the form of power plant thermal effluent, and carried out economic efficiency evaluation of sturgeon aquaculture utilizing thermal effluent of Yeongwol LNG Combined Cycle Power Plant in Gangwon-do. In this analysis, we analyzed the economic efficiency of a model business plan divided into three steps, starting from a small scale in order to minimize the investment risk and financial burden, which is then gradually expanded. The business operation period was assumed to be 10 years (2012~2021), and the NVP (Net Present Value) and economic efficiency (B/C) for the operation period (10 years) were estimated for different loan size by dividing the size of external loan by stage into 80% and 40% based on the basic statistics secured through a site survey. Through the result of analysis, we can see that reducing the size of the external loan is an important factor in securing greater economic efficiency as, while the B/C is 1.79 in the case the external loan is 80% of the total investment, it is presumed to be improved to 1.81 when the loan is 40%. As the findings of this study showed that the economic efficiency of sturgeon aquaculture utilizing thermal effluent of power plant can be secured, it is presumed that regional development project items with high added value can be derived though this, and, in addition, this study will greatly contribute to reinforcement of the capability of local governments to cope with climate change.

  • PDF

Molecular Cloning and Sequence Analysis of Coelomic Cytolytic Factor-like Gene from the Midgut of the Earthworm, Eisenia Andrei (줄지렁이 중장에서 분리한 Coelomic cytolytic factor-유사 유전자의 클로닝 및 염기서열 분석에 관한 연구)

  • Baek, Nam Sook;Lee, Myung-Sik;Park, Sang-Kil;Kim, Dae-hwan;Tak, Eun-Sik;Ahn, Chi-Hyun;Sun, Zhenjun;Park, Soon Cheol
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.16 no.4
    • /
    • pp.64-73
    • /
    • 2008
  • The cDNA of CCF (coelomic cytolytic factor)-like gene (EC 3.2.1.16), a kind of glycosyl hydorlase, was isolated and cloned from the midgut of the earthworm Eisenia anderi. The size of nucleotide sequence appeared to be 1,152 bp and its predicted coding region was composed of 384 amino acid residues including the initiation methionine. The 17 residues at N-terminal end in the deduced amino acid sequence were regarded to be a signal peptide. Based on the amino acid sequence analysis, it appeared that this CCF-like protein could belong to glycosyl hydrolase family 16 (GHF16) and showed a high sequence homology of about 79~99% with CCF and CCF-like proteins from other earthworm species. The CCFs and CCF-like proteins from various earthworm species exhibited a 100% homology in the polysacchride-binding motif and glucanase motif. It has been reported that the CCFs isolated from E. fedita appeared to show a broader pattern recognition specificity than those from other earthworm species because this species resides in decaying organic matter showing very high microbial activity, implying that CCF-like protein isolated in this study from E. andrei might exhibit a broad substrate specificity that is a useful characteristic for industrial application. A phylogenetic analysis using the deduced amino acid sequences of CCF-related proteins through the BLASTX revealed that GHF16 families could be divided into three groups of metazoa, viriplantae and eubacteria subfamily. Subsequently the CCF-related proteins of metazoa subfamily could clearly be subgroup into lophotrochozoan and edysozoan type including a deuterostome origin. Further understanding of the biological properties of E. andrei CCF-like protein should be addressed to regulate the ${\beta}$-D-glucan hydrolysis and production for the industrial uses.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2004 and 2005 - (공기조화, 냉동 분야의 최근 연구 동향 -2004년 및 2005년 학회지 논문에 대한 종합적 고찰-)

  • Choi, Yong-Don;Kang, Yong-Tae;Kim, Nae-Hyun;Kim, Man-Hoe;Park, Kyoung-Kuhn;Park, Byung-Yoon;Park, Jin-Chul;Hong, Hi-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.94-131
    • /
    • 2007
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2004 and 2005 has been done. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD and flow visualization(PIV, PTV and LDV methods) technologies were widely applied for developing facilities and their systems. (2) The research trends of the previous two yews are surveyed as groups of natural convection, forced convection, electronic cooling, heat transfer enhancement, frosting and defrosting, thermal properties, etc. New research topics introduced include natural convection heat transfer enhancement using nanofluid, supercritical cooling performance or oil miscibility of $CO_2$, enthalpy heat exchanger for heat recovery, heat transfer enhancement in a plate heat exchanger using fluid resonance. (3) The literature for the last two years($2004{\sim}2005$) is reviewed in the areas of heat pump, ice and water storage, cycle analysis and reused energy including geothermal, solar and unused energy). The research on cycle analysis and experiments for $CO_2$ was extensively carried out to replace the Ozone depleting and global warming refrigerants such as HFC and HCFC refrigerants. From the year of 2005, the Gas Engine Heat Pump(GHP) has been paid attention from the viewpoint of the gas cooling application. The heat pipe was focused on the performance improvement by the parametric analysis and the heat recovery applications. The storage systems were studied on the performance enhancement of the storage tank and cost analysis for heating and cooling applications. In the area of unused energy, the hybrid systems were extensively introduced and the life cycle cost analysis(LCCA) for the unused energy systems was also intensively carried out. (4) Recent studies of various refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and of alternative refrigerants including carbon dioxide. Efficiency of various compressors and expansion devices are also dealt with for better modeling and, in particular, performance improvement. Thermoelectric module and cooling systems are analyzed theoretically and experimentally. (5) According to the review of recent studies on ventilation systems, an appropriate ventilation systems including machenical and natural are required to satisfied the level of IAQ. Also, an recent studies on air-conditioning and absorption refrigeration systems, it has mainly focused on distribution and dehumidification of indoor air to improve the performance were carried out. (6) Based on a review of recent studies on indoor environment and building service systems, it is noticed that research issues have mainly focused on optimal thermal comfort, improvement of indoor air Quality and many innovative systems such as air-barrier type perimeter-less system with UFAC, radiant floor heating and cooling system and etc. New approaches are highlighted for improving indoor environmental condition as well as minimizing energy consumption, various activities of building control and operation strategy and energy performance analysis for economic evaluation.

Availability Assessment of Single Frequency Multi-GNSS Real Time Positioning with the RTCM-State Space Representation Parameters (RTCM-SSR 보정요소 기반 1주파 Multi-GNSS 실시간 측위의 효용성 평가)

  • Lee, Yong-Chang;Oh, Seong-Jong
    • Journal of Cadastre & Land InformatiX
    • /
    • v.50 no.1
    • /
    • pp.107-123
    • /
    • 2020
  • With stabilization of the recent multi-GNSS infrastructure, and as multi-GNSS has been proven to be effective in improving the accuracy of the positioning performance in various industrial sectors. In this study, in view that SF(Single frequency) GNSS receivers are widely used due to the low costs, evaluate effectiveness of SF Real Time Point Positioning(SF-RT-PP) based on four multi-GNSS surveying methods with RTCM-SSR correction streams in static and kinematic modes, and also derive response challenges. Results of applying SSR correction streams, CNES presented good results compared to other SSR streams in 2D coordinate. Looking at the results of the SF-RT-PP surveying using SF signals from multi-GNSS, were able to identify the common cause of large deviations in the altitude components, as well as confirm the importance of signal bias correction according to combinations of different types of satellite signals and ionospheric delay compensation algorithm using undifferenced and uncombined observations. In addition, confirmed that the improvement of the infrastructure of Multi-GNSS allows SF-RT-SPP surveying with only one of the four GNSS satellites. In particular, in the case of code-based SF-RT-SPP measurements using SF signals from GPS satellites only, the difference in the application effect between broadcast ephemeris and SSR correction for satellite orbits/clocks was small, but in the case of ionospheric delay compensation, the use of SBAS correction information provided more than twice the accuracy compared to result of the Klobuchar model. With GPS and GLONASS, both the BDS and GALILEO constellations will be fully deployed in the end of 2020, and the greater benefits from the multi-GNSS integration can be expected. Specially, If RT-ionospheric correction services reflecting regional characteristics and SSR correction information reflecting atmospheric characteristics are carried out in real-time, expected that the utilization of SF-RT-PPP survey technology by multi-GNSS and various demands will be created in various industrial sectors.

The Development of National Competency Standard(NCS) Regarding Casino Operations Management (카지노운영관리 직무에 관한 국가직무능력표준(NCS) 개발)

  • Kim, Dong-Yeon;Oh, Seung-Gyun;Koo, Ja-Gil;Kim, Jinsoo
    • 대한공업교육학회지
    • /
    • v.39 no.1
    • /
    • pp.143-163
    • /
    • 2014
  • This study developed a National Competency Standard(NCS) regarding the casino operations management based on the manual for developing National Competency Standard of 13 years and a revised classification system chart of the National Competency Standard. For the research method, this study developed a national competency standard of relevant jobs after going through review, consultation, modification, supplementation, and reporting procedures 10 times with development experts of the National Competency Standard, the industrial setting professionals, education and training experts, qualification(job analysis) experts, facilitators, and a working group of job verification committee based on the phased range and DACUM procedure of study. The major development results of this study are as follows. First, this study selected and defined duties based on the revised classification system chart of the National Competency Standard, then drew and developed total 8 ability units based on the applicable duties. Secondly, based on the developed ability units, total 27 ability unit factors were deduced and developed. Thirdly, a standard system by ability unit factor was developed based on the level of the national competency standard and revised classification system chart, then this study deduced and developed a supra-domain of the standard system by competency units using the standard tranquility value by these competency unit factors. Based on such development contents and guidelines for the national competency standard ability unit classification number, this study deduced and developed category numbers by relevant competency unit. Fourthly, total 27 relevant performance standard by competency units and knowledge, skill, and attitude were deduced and developed. Fifthly, this study deduced and developed a scope of application, work situation, evaluation guide, core competency, and development history in reference to the total 8 relevant competency units based on the duties.

Experimental Analysis of Nodal Head-outflow Relationship Using a Model Water Supply Network for Pressure Driven Analysis of Water Distribution System (상수관망 압력기반 수리해석을 위한 모의 실험시설 기반 절점의 압력-유량 관계 분석)

  • Chang, Dongeil;Kang, Kihoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.6
    • /
    • pp.421-428
    • /
    • 2014
  • For the analysis of water supply network, demand-driven and pressure-driven analysis methods have been proposed. Of the two methods, demand-driven analysis (DDA) can only be used in a normal operation condition to evaluate hydraulic status of a pipe network. Under abnormal conditions, i.e., unexpected pipe destruction, or abnormal low pressure conditions, pressure-driven analysis (PDA) method should be used to estimate the suppliable flowrate at each node in a network. In order to carry out the pressure-driven analysis, head-outflow relationship (HOR), which estimates flowrate at a certain pressure at each node, should be first determined. Most previous studies empirically suggested that each node possesses its own characteristic head-outflow relationship, which, therefore, requires verification by using actual field data for proper application in PDA modeling. In this study, a model pipe network was constructed, and various operation scenarios of normal and abnormal conditions, which cannot be realized in real pipe networks, were established. Using the model network, data on pressure and flowrate at each node were obtained at each operation condition. Using the data obtained, previously proposed HOR equations were evaluated. In addition, head-outflow relationship at each node was analyzed especially under multiple pipe destruction events. By analyzing the experimental data obtained from the model network, it was found that flowrate reduction corresponding to a certain pressure drop (by pipe destruction at one or multiple points on the network) followed intrinsic head-outflow relationship of each node. By comparing the experimentally obtained head-outflow relationship with various HOR equations proposed by previous studies, the one proposed by Wagner et al. showed the best agreement with the exponential parameter, m of 3.0.

Studies on the CA Storage of Sweet Persimmon in Polyethylene Film Pack (Polyethylene film포장(包裝)에 의(依)한 단감의 CA저장(貯藏)에 관(關)한 연구(硏究))

  • Min, Byong-Yong;Oh, Sang-Lyong
    • Korean Journal of Food Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.128-134
    • /
    • 1975
  • For development of long-term storage method of sweet-persimmons using polyethylene film bags, basic experiment was conducted with 30 boxes of sweet-persimmons in 1973 and the same experiment was extended for industrial application with 2,500 boxes of the persimmons in the cold storage of Jinyoung Sweet-persimmon Association in 1974. Investigation was made on change of the quality by storage period. At the same time, persimmons put in the cold storage test were shipped to market at different time in order to monitor consumer response and commercial feasibility. The followings are conclusion obtained from the result of this experiment. 1. Storage of sweet-persimmon, Buyu, produced in Jinyoung, Kimhae was possible for 1 month at $2^{\circ}C{\pm}1^{\circ}C$ cold storage. This storage period was extended to 4 months until the end of February in case that the fruits were hermetically sealed in P.E. film bags of 0.08 to 0.1 mm thickness. 2. During the storage period of sweet-persimmons packed in the film bags, the loss of weight due to evaporation was effectively prevented with use of the film of bag thicker than 0.04 mm. 3. The storage ability of 3-5 persimmons per small bag was somewhat superior to that of many persimmons packed in the large box of 15kg capacity. 4. The thicker the film of bags, the more $CO_2$ gas was accumulated inside, however, from 1 month after beginning of the storage the rate of $CO_2$ accumulation became very low maintaining the stabilized level of 5-6% at the plot of 0.06-0.08mm thick bags. 5. While the persimmons were in storage, decreased was the content of total sugars, total acids, and vitamin C, of which the phenomenon was remarkable especially with the fruits of non-packed plot. 6. The sweet-persimmons in the film bags subjected to cold storage when shipped to market in their intact condition were more beneficial than when they were shipped out in unpacked condition. The intact fruits packed in the P.E. film bags were able to keep their commercial value for 10days in the outdoor situation. 7. The sweet-persimmons that were packed in the film bags and put in the cold storage had maintained promissing marketability and the economic feasibility was acknowledged when the experimental practice was applied to industrial scale.

  • PDF

Pain Reduction Effects of Lidocaine Gel for Urethral Catheterization : A Systematic Review and Meta-Analysis (요도 카테터 삽입술에서 리도카인 윤활제의 통증 감소 효과 : 체계적 문헌고찰과 메타분석)

  • Hong, Hyun-Jung;Kim, Ga-Eun;Lee, Ha-Nee;Lee, A-Reum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.438-448
    • /
    • 2017
  • This study was a systematic review and meta-analysis that evaluated the results of research on the pain reduction effects of lidocaine gel for urethral catheterization in adults. A literature search was conducted using seven electronic databases, gray literature and other resources based on the guidelines of Preferred Reporting Items for Systematic review and Meta-Analysis (PRISMA). A Risk of Bias (RoB) tool was applied to assess the quality of selected studies. Data were analyzed using the RevMan 5.3.-program. Sixteen randomized controlled trials involving 1904 adults were included. RoB was not observed in the funnel plot. Overall, lidocaine gel was effective for pain reduction during urethral catheterization (Standard Mean Difference[SMD] -0.96;95% CI: -1.43, -0.49). To explore the cause of heterogeneity (I2=95%, p<.001), subgroup analysis was conducted according to three catheter types (urinary catheter, flexible cystoscopy, and rigid cystoscopy) and the SMDs were -0.88 (95% CI:-1.51, -0.26), -0.31 (95% CI:-0.63, 0.01), and -1.93 (95% CI:-2.88, -0.97), respectively. A significant pain reduction effect was observed regardless of gender in urinary catheterization. However, in rigid cystoscopy, a significant pain reduction effect was observed only in male subjects. Pain reduction effects were observed when 10~11ml lidocaine gel was used during rigid cystoscopy and when lubrication was used during urinary catheterization, irrespective of application time. These findings suggest that lidocaine gel is a useful anesthetic lubricant for urinary catheterization and rigid cystoscopy in male adults.