• Title/Summary/Keyword: Inductor current

Search Result 678, Processing Time 0.038 seconds

Analysis of Generalized n-winding Coupled Inductor in dc-dc Converters

  • Kang, Taewon;Suh, Yongsug
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.88-89
    • /
    • 2017
  • This paper investigates the design of multi-winding coupled inductor for minimum inductor current ripple in rapid traction battery charger systems. Based on the general circuit model of multi-winding coupled inductor together with the operating principles of dc-dc converter, the relationship between the ripple size of inductor current and the coupling factor is derived under the different duty ratio. The optimal coupling factor which corresponds to a minimum inductor ripple current becomes -(1/n-1), i.e. a complete inverse coupling without leakage inductance, as the steady-state duty ratio operating point approaches 1/n, 2/n, … or (n1)/n. In an opposite manner, the optimal coupling factor value of zero, i.e. zero mutual inductance, is required when the steady-state duty ratio operating point approaches either zero or one.

  • PDF

A KY Converter Integrated with a SR Boost Converter and a Coupled Inductor

  • Hwu, Kuo-Ing;Jiang, Wen-Zhuang
    • Journal of Power Electronics
    • /
    • 제17권3호
    • /
    • pp.621-631
    • /
    • 2017
  • A KY converter integrated with a conventional synchronously rectified (SR) boost converter and a coupled inductor is presented in this paper. This improved KY converter has the following advantages: 1) the two converters use common switches; 2) the voltage gain of the KY converter can be improved due to the integration of a boost converter and a coupled inductor; 3) the leakage inductance of the coupled inductor is utilized to achieve zero voltage switching (ZVS); 4) the current stress on the charge pump capacitors and the decreasing rate of the diode current can be limited due to the use of the coupled inductor; and 5) the output current is non-pulsating. Moreover, the active switches are driven by using one half-bridge gate driver. Thus, no isolated driver is needed. Finally, the operating principle and analysis of the proposed converter are given to verify the effectiveness of the proposed converter.

병렬 Interleaved 컨버터에서 일반화된 순환전류 제어 방법 (Analytical Approach of Circulating Current Mitigation Effect using Coupled Inductor in Parallel Interleaved Converters)

  • 임창순;이귀준;김래영;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.470-471
    • /
    • 2010
  • In this paper, the coupled inductor with three branches in two interleaved converter are analyzed to effectively suppress the high frequency circulating current since the circulating current controller cannot mitigate the high frequency circulating current. As a result, the novel averaged model including the coupled inductor with zero sequence components is developed for reducing the low and high frequency circulating current simultaneously.

  • PDF

Load Disturbance Compensation for Stand-alone Inverters Using an Inductor Current Observer

  • Choe, Jung-Muk;Moon, Seungryul;Byen, Byeng-Joo;Lai, Jih-Sheng;Lim, Young-Bae;Choe, Gyu-Ha
    • Journal of Power Electronics
    • /
    • 제17권2호
    • /
    • pp.389-397
    • /
    • 2017
  • A control scheme for stand-alone inverters that utilizes an inductor current observer (ICO) is proposed. The proposed method measures disturbance load currents using a current sensor and it estimates the inductor current using the ICO. The filter parameter mismatch effect is analyzed to confirm the ICO's controllability. The ICO and controllers are designed in a continuous-time domain and transferred to a discrete-time domain with a digital delay. Experimental results demonstrate the effectiveness of the ICO using a 5-kVA single-phase stand-alone inverter prototype. The experimental results demonstrate that the observed current matches the actual current and that the proposed method can archive a less than 2.4% total harmonic distortion (THD) sinusoidal output waveform under nonlinear load conditions.

평균 모델을 이용한 Z-소스 인버터의 제어 (Control of the Z-Source Inverter using Average Model)

  • 이광운
    • 전력전자학회논문지
    • /
    • 제19권3호
    • /
    • pp.290-296
    • /
    • 2014
  • This paper presents a design strategy for the control of the Z-source inverter (ZSI). For the Z-network capacitor voltage control, the average current model is derived to describe the dynamics of the voltage control and the controller outputs the average current command for the capacitor. Z-network inductor current reference is derived from the average current model of the Z-network capacitor. The inner current control loop outputs the average voltage command for the Z-network inductor and the shoot-through duty ratio of the ZSI is calculated from the output using the average voltage model of the Z-network inductor. The gain values of the current and voltage controllers are directly obtained by the Z-network parameters and desired bandwidth of each controller without a gain tuning process.

Study on Soft-Switching Transformers Inductor Boost Converter for Fuel Cell Powered Railway Vehicle

  • Jung, No-Geon;Kim, Jae-Moon
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2553-2560
    • /
    • 2018
  • In Korea, there are no instances where a hydrogen fuel cell power generation system has been used in a railway vehicle. Only the basic topology has been studied. In the previous study, conventional converters using a single switch were applied to the fuel cell power generation system. Therefore, current stress on the switch at converter on-off transitions would be large when controlling a large-capacity railway vehicle. In addition, since the input side ripple is also large, there is a problem with a shortening of the lifetime of both the fuel cell power generation system and the inductor. In this paper, a soft-switching transformer inductor boost converter for fuel cell powered railway vehicles was proposed. A technique to reduce both the switching current stress generated during on-off transitions, and the input ripple current flowing in the inductor were studied. The soft-switching TIB converter uses a transformer-type inductor to configure the entire circuit in an interleaved method, and reduces both input current ripple and the current ripple of the inductor and switch.

불연속 전류모드에서의 다상 교호 강압컨버터의 정상상태 해석 및 모델링 (Modeling and Steady-state Analysis of the Multi-Phase Interleaved Buck converter in Discontinuous Inductor Current Mode)

  • 장성동;장은승;정세교;신휘범;이현우
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.506-510
    • /
    • 2004
  • A multi-phase interleaved buck converter is used to reduce current ripples and filter size of a power supply. This paper addresses the modelling and steady-state analysis of the multi-phase interleaved buck converter operated in discontinuous inductor current mode. The model is derived using an averaging technique in steady state. The do voltage ratio and the range of the discontinuous inductor current mode(DICM) and the continuous output current mode(COCM) are derived from the averaged state-space model. In addition, the efficiency is investigated according to the number of phase.

  • PDF

병렬 삼상 부스트 컨버터에서 일반화된 순환전류 제어 방법 (Generalized Circulating Current Control Method in Parallel Three-Phase Boost Converters)

  • 임창순;이귀준;김래영;현동석
    • 전력전자학회논문지
    • /
    • 제16권3호
    • /
    • pp.250-257
    • /
    • 2011
  • 본 논문은 병렬 삼상 부스트 컨버터에서 Interleaved PWM에 의해 발생하는 고 주파수 순환전류를 효과적으로 저감시키기 위해서, AC 입력단에 연결되는 삼상 결합 인덕터의 특성을 분석하였다. 제시된 삼상 결합 인덕터 분석은 삼상 결합 인덕터의 구조와 전압 방정식의 해석을 통하여 이루어졌다. 그리고 이것을 바탕으로 기존의 저 주파수 평균화 모델에 삼상 결합 인덕터를 추가하여, 고 주파수 순환전류와 저 주파수 순환전류를 동시에 저감시킬 수 있는 새로운 형태의 평균화 모델을 제안하였다. 새로운 평균화 모델의 영상성분을 이용하면, 삼상 결합 인덕터와 라인 인덕터의 순환전류에 대한 총 인덕턴스를 각각 구해 비교 할 수 있다. 시뮬레이션과 실험결과를 토대로 병렬 삼상 부스트 컨버터에서 사용되는 삼상 결합 인덕터의 유용성을 검증하였다.

Analysis and Design of a Single-Phase Tapped-Coupled-Inductor Boost DC-DC Converter

  • Gitau, Michael Njoroge;Mwaniki, Fredrick Mukundi;Hofsajer, Ivan W.
    • Journal of Power Electronics
    • /
    • 제13권4호
    • /
    • pp.636-646
    • /
    • 2013
  • A single-phase tapped-inductor boost converter has been proposed previously. However, detailed characterization and performance analysis were not conducted. This paper presents a detailed characterization, performance analysis, and design expressions of a single-phase tapped-coupled-inductor boost converter. Expressions are derived for average and RMS input current as well as for RMS input and output capacitor current ripple. A systematic approach for sizing the tapped-coupled inductor, active switch, and output diode is presented; such approach has not been reported in related literature. This study reveals that sizing of the inductor has to be based on current ripple requirement, turns ratio, and load. Conditions that produce discontinuous inductor current are also discussed. Analysis of a non-ideal converter operating in continuous conduction mode is also conducted. The expression for the voltage ratio considering the coupling coefficient is derived. The suitability of the converter for high-voltage step-up applications is evaluated. Factors that affect the voltage boost ratio are also identified. The effects of duty ratio and load variation on the performance of the converter are also investigated. The theoretically derived characteristics are validated through simulations. Experimental results obtained at a low power level are included to validate the analytical and simulation results. A good agreement is observed among the analytical, simulation, and experimental results.

밸리-필 정류 회로의 역률 개선 (A New Valley-fill Circuit for Improving Power Factor)

  • 최남열;안찬권;이치환
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 V
    • /
    • pp.2935-2938
    • /
    • 2003
  • A new Valley-fill circuit for improving PF(power factor) is proposed in this paper. The proposed topology combines Valley-fill rectifier and an additional inductor for boosting. In the proposed circuit, a shapc of input current is related to the PWM duty cycle. The boosting inductor makes improve PF by the electric charge transfer action. The operation principle and the shape of input current arc analyzed as applied the boosting inductor. The optimum value of boosting inductor is determined. A 100W single-stage converter has been designed and tested. Experimental results are presented to verify the validity of the proposed converter.

  • PDF