• Title/Summary/Keyword: Induction Interference

Search Result 65, Processing Time 0.024 seconds

Study on Optimal Phase Arrangement Considering the Characteristics of Inductive Interference from Overhead Transmission Lines (가공송전선 유도장해 특성을 고려한 최적 상배열 연구)

  • Kang, Kyung-Doo;Kim, Jin-Gyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.1
    • /
    • pp.13-18
    • /
    • 2019
  • The domestic overhead transmission lines use a vertical configuration and reverse phase arrangement, but when there is a limitation in steel tower height because the transmission lines pass a height limit zone or special zone, an application of triangular arrangement is necessary, and a study on the optimal phase arrangement to minimize inductive interference for this is necessary. If conductor arrangement are changed, the action of electrostatic induction and electromagnetic induction becomes different from before changes, so the changed conductor arrangement should be reviewed in terms of inductive interference. So this paper presents an optimal phase arrangement to reduce inductive interference by calculating electrostatic induction and electromagnetic induction according to conductor arrangement.

Phenomenon of Power Interference and Screening Factor (전력유도 현상과 차폐계수)

  • 황종선;김영민;이경욱;김재준
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.621-624
    • /
    • 2001
  • A metal sheath provides a cable with electrostatic screening and a degree of magnetic screening. The presence of a screen on a cable also reduces the induction arising from the high-frequency components of transients caused by power-line switching and also induced transients from lightning strokes; such transient induced voltages are of increasing importance with the increasing use of miniaturized telecommunication equipment with very small thermal capacity. This paper describes electrostatic induction and electromagnetic induction caused by power interference. Also screening factors are proposed.

  • PDF

The Effects of AC Corrosion on Underground Gas Pipeline Running Parallel with High Power Cables (전력케이블과 가스배관의 병행구간에 대한 교류부식 영향)

  • 배정효;김대경;김기준
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.10
    • /
    • pp.577-582
    • /
    • 2000
  • This paper analyze the interference problems, especially Ac corrosion when the gas pipeline is buried with power cable in the same submarine tunnel. This paper present the results of the study about interference mechanism(inductive coupling, conductive coupling, resistive coupling), AC corrosion, limitation of safety voltage, modeling of power cables, gas pipeline and grounding systems, analysis of induction voltage and optimal arrangement of power cables.

  • PDF

Phenomenon of Power Interference and Screening Factor (전력유도 현상과 차폐계수)

  • Hwang, Jong-Sun;Kim, Yeong-Min;Lee, Kyoung-Wook;Kim, Jae-Joon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.621-624
    • /
    • 2001
  • A metal sheath provides a cable with electrostatic screening and a degree of magnetic screening. The presence of a screen on a cable also reduces the induction arising from the high-frequency components of transients caused by power-line switching and also induced transients from lightning strokes; such transient induced voltages are of increasing importance with the increasing use of miniaturized telecommunication equipment with very small thermal capacity. This paper describes electrostatic induction and electromagnetic induction caused by power interference. Also screening factors are proposed.

  • PDF

Adhesion between the Nylon Cylinder and Steel Shaft by Expansion Fit and Induction Heating (나일론 실린더와 강축의 열박음과 유도가열에 의한 접합의 연구)

  • Choi Sin-Jin;Kang Suk-Choon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.2
    • /
    • pp.139-147
    • /
    • 2005
  • The lubricant impregnated MC nylon has good frictional properties, but its mechanical strength is inferior to steel for the mechanical elements. For the tribological application Nylon as gears, sliding bearings, cam and etc, the steel shafts are fitted in pre-heated nylon cylinder by a process of interference expansion fit and bonded by induction heating method. The joint shear strength of the two materials was measured by a universal test machine. From the study, the adhesive shear strength between these two materials was affected by the factors of the interference between nylon and steel, the size of nylon cylinder, knurl of steel shaft and inducting heating conditions. The most effective jointing conditions were analyzed and decided for the practical application in the industry.

A Study on the Output Waveform Improvement of PWM Inverter (PWM 인버터의 출력파형 개선에 관한 연구)

  • Jeon, Hi-Jong;Kim, Kuk-Jin;Choe, Young-Han;Yu, Geon-Su
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.278-282
    • /
    • 1990
  • In this paper, two different plusewidth modulation(PWM) for inverter and voltage control technique are described. Inverter output harmonics are harmful in induction motor drive because it lead to ripple torque and induction interference. In order to reduce or minimize losses, various forms of PWM strategy such as PM(Positive Modulation) and NM(Negative Modulation) are discussed.

  • PDF

A Study on Prediction of Conducted EMI In PWM inverter fed Induction Motor Drive System (PWM 인버터-유도전동기 구동시스템의 전도노이즈 예측에 관한 연구)

  • 이진환;안정준;원충연;김영석;최세완
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.367-372
    • /
    • 1999
  • In this paper, an inverter fed induction motor drive system is analyed in order to predict the conducted interference. High frequency model for inverter, motor and system parasitic components are proposed. High frequency component allows time and frequency domain analysis to be performed with standard PSpice tool. The overall high frequency component and model are verified by comparing simulation and experimental result.

  • PDF

A Case Study on the AC Corrosion Effects of Gas Pipeline by High Voltage Induction in Submarine Tunnel (해저터널내 고전압 유도에 의한 가스배관의 교류전식 영향 사례 연구)

  • Bae, Jeong-Hyo;Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.346-348
    • /
    • 2001
  • This paper analyze the interference problems, especially AC corrosion when the gas pipeline is buried with power cable in the same submarine tunnel. This paper present the results of the study about AC corrosion, limitation of safety voltage, modeling of power cables, gas pipeline and grounding systems, analysis of induction voltage according to various circumstance, soil resistivity, length of tunnel. and so on.

  • PDF

Studies on the Transovarial Transmission of Cytoplasmic Polyhedrosis Virus with Reference to the Phenomena of Induction, Interference and Virulence Enhancement in the Silkworm, Bombyx mori (가잠 세포질다각체 바이러스의 유발, 간섭 및 병원성 증진현상에 의한 경난전달에 관한 연구)

  • 임종성
    • Journal of Sericultural and Entomological Science
    • /
    • v.16 no.2
    • /
    • pp.55-75
    • /
    • 1974
  • Transovarial transmission of cytoplamic polyhedrosis virus in the silkworm was studied by observing the phenomena of induction, interference and virulence enhancement in the larvae from moths inoculated with hexagonal Polyhedra of cytoplasmic polythedrosis virus. The experimental results obtained are as followings. 1. The effect of inoculation with tetragonal polyhedra of cytoplasmic polyhedrosis virus on the rate of infective induction with hexagonal polyhedron virus and with hexagonal plus tetragonal polyhedron viruses in the larvae from moths infected with hexagonal polyhedron virus was studied. Infection rate was higher by 40 to 60 percent in the larvae from infected female group than in tile larvae from noninfected female group. 2. In the studies of the effect of formalin-feeding on the induction of infection with hexagonal polyhedron virus, infection rate was higher by 40 percent in the larvae from infected female group than in the larvae from noninfected female group. However, there was no significant difference in the infection rates between the two formalin-concentration groups. 3. The effect of cold treatment on the induction of infection with hexagonal polyhedron virus was studied. Infection rate was higher by 50 percent in the larvae from infected female group than ill the larvae from noninfected female group. No difference was found in the infection rates of the two treatment groups of 12 and 48 hours. 4. The phenomena of induction and interference were studied by observing rate of infection with hexagonal polyhedron virus induced by the inoculation with tetragonal polyhedron virus. The degree of interference of primary hexagonal polyhedron virus by secondary tetragonal Ployhedron virus was increased as the dosage of secondary virus was increased. At the concentration of 1${\times}$10$\^$8/m1 of the secondary virus, the degree of interference was similar to. that of control group. On the other hand, infection with tetragonal polyhedron virus at low concentration was interfered by the primary virus. At the concentration of 1N10f/m1 of tetragonal polyhedron virus, however, the rate of infection with tetragonal polyhedron virus was increased sharply, which is still lower by 30 percent than that of control group. 5. In the studies of induction and virulence enhancement, based on the 1ate of mixed infection with hexagonal and tetragonal polyhedron viruses, the highest difference of infection rate between experimental group and control group exceeded 40 percent when the concentration of tetragonal polyhedron virus was 1${\times}$10$\^$7/m1. However, the infection rate of control group was not affected by concentrations of tetragonal polyhedron virus.

  • PDF

A Case Study on the AC Corrosion Effects for Bridges of Metallic Structure (철제구조 교량의 전식영향 연구)

  • Ha, Tae-Hyun;Lee, Hyun-Goo;Bae, Jeong-Hyo;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.356-358
    • /
    • 2001
  • In general, when power lines, D/L and T/L are running parallel with bridge of metallic structure or crossing each other, AC corrosion is occur due to AC interference. This paper presents the results of AC interference mechanism, decision criteria of AC interference, and AC corrosion effects by analysis of AC induction voltage on pier and abut of bridge.

  • PDF